감극결선용 자속구속형 전류제한기의 사고주기별 전압전류 특성 (Voltage-Current Characteristics According to Fault Period of Flux-Lock SFCL with subtractive polarity winding)

  • 한태희;황종선;조용선;박형민;남긍현;이나영;최효상;임성훈;정동철;최명호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 광주전남지부
    • /
    • pp.101-102
    • /
    • 2006
  • We investigated the characteristics of flux-lock type superconducting fault current limiter (SFCL) by the fault cycles. Since the recovery characteristics of a superconducting element in the flux-lock type SFCL were dependent on the winding' direction between two coils, the analysis for the recovery characteristics of this type SFCL together with the current limiting characteristic is necessary to apply it to power system. As the fault cycles was increased from 1 cycle to 5 cycles, the initial limiting current ($I_{ini}$) and quench characteristic were mostly same. As the fault period increases, the recovery time of the superconducting element increases. The consumed energy and recovery characteristics in a superconducting element show the same tendency.

  • PDF

코일형 한류소자의 교류손실 특성 (AC Loss Characteristic in the Fault Current Limiting Elements of a Coil Type)

  • 류경우;마용호
    • 한국전기전자재료학회논문지
    • /
    • 제18권4호
    • /
    • pp.370-374
    • /
    • 2005
  • AC loss of a superconducting conductor has a strong influence on the economic viability of a superconducting fault current limiter, which offers an attractive means to limit short circuit current in power systems. Therefore, the AC loss characteristics in several fault current limiting elements of a coil type have been investigated experimentally. The test result shows that AC losses measured in the fault current limiting elements depend on arrangement of a voltage lead. The AC loss of a bifilar coil is smallest among the fault current limiting elements of the coil type. The measured AC loss of the bifilar coil is much smaller than that calculated from Norris's elliptical model. However, the loss measured in a meander, which is frequently used in a resistive fault current limiter, agrees well to the theoretical one.

전력계통에 초전도한류기 적용시 차단용량 확보를 위한 초전도한류기 적용방안 연구 (Analysis on the Application Capacity of the Superconducting Fault Current Limiter considering Reclosing and Fault Current)

  • 김진석;임성훈;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.592-593
    • /
    • 2015
  • Recently, the fault current has increased to exceed the rated breaking capacity of protective device due to the growth of the power demand on the power system where is changed into the loop-, mesh-, network grid. To limit fault current, the superconducting fault current limiter (SFCL) is announced with various methods. In many researches, the current limiting effect with the SFCL has been analyzed considering the rated breaking capacity of the CB with one fault condition. However, the power system has various short circuit and operation conditions. In order to select the capacity of the SFCL with reclosing operation and burden of the fault current on the protective device, the characteristics of the power system were investigated. Through the analysis, the evaluation method of the current rate was improved.

  • PDF

도체의 배열 및 전류방향이 코일형 한류소자의 교류손실 특성에 미치는 영향 (Effect of Conductor's Arrangement and Current Direction on AC Loss Characteristics of a Fault Current Limiting Coil)

  • 마용호;류경우;박권배;오일성
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권3호
    • /
    • pp.17-20
    • /
    • 2005
  • AC loss of a high $T_c$ superconducting conductor has a strong influence on the economic viability of a superconducting fault current limiter, which offers an attractive means to limit short circuit current in the power systems. Therefore, several samples of the fault current limiting coils have been fabricated and the effect of conductor's arrangement and current direction on AC loss characteristics investigated experimentally The test result shows that the AC losses measured in the fault current limiting coils depend significantly on the conductor's arrangement. Futhermore, they are also considerably influenced by the conductor's current direction. The AC loss measured in the face-to-face arrangement is smallest among the fault current limiting coil samples.

저항형 초전도한류기의 신뢰도 모델을 적용한 배전계통 신뢰도 평가에 관한 연구 (A Study on the Evaluation of Distribution Reliability Considering Reliability Model for a Resistive-Type of Superconducting Fault Current Limiter)

  • 김성열;김욱원;김진오
    • 전기학회논문지
    • /
    • 제60권3호
    • /
    • pp.465-470
    • /
    • 2011
  • Recently fault currents are increasing in a network. It is caused by increase in electric demand and high penetration of distributed generation with renewable energy sources. Moreover, distribution network has become more and more complex as mesh network to improve the distribution system reliability and increase the flexibility and agility of network operation. Accordingly, the fault current will exceed capacity of circuit breakers soon and all the various rational solutions to solve this problem are taken into account. Under these circumstances, superconducting fault current limiter(SFCL) is a new alternative in the viewpoint of technical and economic aspects. This study presents operation processes for a resistive-type of SFCL, and it proposes reliability model for the SFCL. When a SFCL is installed into a network, the contribution of decreased fault currents to failure for distribution equipments can be quantified. As a result, it is expected that a SFCL makes the reliability of adjacent equipments on existing network improve and these changes are analyzed. We propose a methodology to evaluate the reliability in the distribution network where a SFCL is installed considering a reliability model for resistive-type of SFCL and reliability changes for adjacent equipments which are proposed in this paper.

초전도 한류기의 실계통 적용 시의 한류 특성 해석 (Performance of Superconducting Fault Current Limiter for Real Substation)

  • 김홍규;이병윤;박경엽
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.201-204
    • /
    • 2003
  • This paper presents the analysis of current limiting performance of superconducting fault current limiter(SCFCL) for real substation. The resistive and inductive type SCFCLs are investigated for 154㎸ substation. The current limiting performance of SCFCL is evaluated with respect to the time constant of SCFCL and impedance of SCFCL.

  • PDF

초전도 한류기 적용을 통한 모의 송전계통의 고장 전류 저감 분석 (Analysis of Transmission Power System with Superconducting Fault Current Limiter for Reducing a Fault Current)

  • 김명현;김진석;임성훈;김재철;추동욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.718-719
    • /
    • 2011
  • Lately, the demand for electrical power has been significantly increased. As a result a power transmission system has been improved. On the other hand fault current increased more than past. Superconducting fault current limiter (SFCL) is one of the solutions to limit fault current. However, SFCL's research has not advanced in a power transmission system fully. Therefore, we studied effect of SFCL in a power transmission system. The power distribution system is open-loop circuit, but a power transmission system is closed-loop system. Consequently, Fault current in a power transmission system is larger than fault current in a power distribution system. we exerimented a simple closed-loop power transmission system circuit.

  • PDF

이중퀜치를 이용한 삼상변압기형 한류기의 고장전류제한 동작 분석 (Analysis on Fault Current Limiting Operation of Three-Phase Transformer Type SFCL Using Double Quench)

  • 한태희;고석철;임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제35권2호
    • /
    • pp.184-189
    • /
    • 2022
  • In this paper, the fault current limiting operations of three-phase transformer type superconducting fault current limiter (SFCL) using double quench, which consisted of E-I iron core with three legs wound by primary and secondary windings and two superconducting modules (SCMs), were analyzed according to three-phase ground fault types. To verify the effective operation of the three-phase transformer type SFCL using double quench, the test circuit for three-phase ground faults was constructed, and the fault current tests were carried out. Through analysis on the fault current test results, the different fault current limiting characteristics of three-phase transformer type SFCL using double quench from three-phase transformer type SFCL using three SCMs were discussed.

단락사고에 대한 저항형 초전도 한류기의 실계통 시뮬레이션 (Simulation of a Resistive Superconducting Fault Current Limiter for Line Faults in the Power Grid)

  • 최효상;황시돌;현옥배
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제1권1호
    • /
    • pp.28-32
    • /
    • 1999
  • We have performed an EMTDC simulation for the current limiting effects of a superconducting fault current limiter (SFCL). The fault currents in the 154 kV transmission line between the arbitrary S1 and S2 substations increased up to 54 KA and 60 KA during the line-to-line and three phase faults, respectively. The SFCL with 100$\omega$ of resistance after quench limited the currents to less than 17 KA within a half cycle. This limited current is well below the upper limit of a circuit breaker, suggesting that the resistance of the SFCL in the transmission line is sufficient.

  • PDF

자속구속형 고온초전도 전류제한기 사고전류제한 특성 (Fault Current Limiting Characteristic of Flux-Lock Type HTSC Fault Current Limiter)

  • 임성훈;최명호;박복기;송재주;박대희;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.105-108
    • /
    • 2002
  • In this paper, we investigated the fault current limiting characteristic of flux-lock type High-Tc superconducting fault current limiter(HTSC-FCL), which is comprised of a flux-lock reactor and an external magnetic field coil covering the HTSC element In this HTSC-FCL, the initial limiting current level can be controlled by adjusting the inductance of the each coil. Furthermore, the fault current limiting characteristics of HTSC-FCL can be improved by applying 'the external magnetic field into the HTSC element We performed the computer simulation by numerical analysis about the flux-lock type HTSC-FCL and compared the results of experiment with simulation ones. We can obtain the same results from both the computer simulation and the experiment except for the time immediately after fault occurs.

  • PDF