• 제목/요약/키워드: suggested temperature

검색결과 2,714건 처리시간 0.026초

빙축열 시스템의 지능형 냉방부하예측에 관한 연구 (The Study on Intelligent Cooling Load Forecast of Ice-storage System)

  • 고택범
    • 전기학회논문지
    • /
    • 제57권11호
    • /
    • pp.2061-2065
    • /
    • 2008
  • In the conventional operation of ice-storage system based on operator's experience and judgement, the failure in forecast of cooling load occurs frequently due to operator's misjudgement and unskilled operation. This study presents the method of constructing self-organizing fuzzy models which forecast tomorrow temperature, humidity and cooling load periodically for economic and efficient operation of ice-storage system. To check the effectiveness and feasibility of the suggested algorithm, the actual example for forecasting temperature, humidity and cooling load of ice- storage system in KEPCO training institute, Sokcho, is examined. The computer simulation results show that the accuracy of temperature, humidity, cooling load forecast of the suggested algorithm is higher than that of the conventional methods.

동결건조 제어변수가 마늘의 승화건조시간에 미치는 영향 (Effects of Freeze Dry Control Parameters on the Sublimation Drying Time of Garlic paste)

  • 박노현;배신철
    • Journal of Biosystems Engineering
    • /
    • 제18권2호
    • /
    • pp.122-132
    • /
    • 1993
  • Effects of physical properties of garlic paste and freeze dry control parameters on the sublimation drying time were investigated to verify optimal operating method in freeze drying. A mathematical model of freeze drying by sublimation was suggested and used to estimate the drying time of garlic paste. Under various conditions, the drying time of garlic paste was calculated using the computer program for the suggested model. Among the physical properties of garlic paste, melting temperature was evaluated the most important factor in affecting the drying time. In supplying methods of the required heat energy for sublimation, it would be the best way to control the upper plate temperature and the lower plate temperature independently.

  • PDF

신경회로망을 이용한 일일 냉방부하 예측에 관한 실험적 연구 (Experimental Study on Cooling Load Forecast Using Neural Networks)

  • 신관우;이윤섭;김용태;최병윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.61-64
    • /
    • 2001
  • The electric power load during the peak time in summer is strongly affected by cooling load. which decreases the preparation ratio of electricity and brings about the failure in the supply of electricity in the electric power system. The ice-storage system and heat pump system etc are used to settle this problem. In this study, the method of estimating temperature and humidity to forecast the cooling load of ice-storage system is suggested. And also the method of forecasting the cooling load using neural network is suggested. For the simulation, the cooling load is calculated using actual temperature and humidity. The forecast of the temperature, humidity and cooling load are simulated. As a result of the simulation, the forecasted data approached to the actual data.

  • PDF

급식소에서 제공되는 돼지고기 장조림과 햄ㆍ오이샐러드의 조리 후 보관방법 및 시간이 살모넬라(Salmonella typhimurium) 식중독균의 생존에 미치는 영향 (Influence of Holding Methods and Times on Recovery of Salmonella Typhimurium in Simmered Pork and Ham at Cucumber Salad Served at Foodservice Institutions)

  • 고성희;김지영
    • 한국식품조리과학회지
    • /
    • 제20권4호
    • /
    • pp.352-357
    • /
    • 2004
  • This study was performed to predict the multiplication growth patterns of Salmonella typhimurium according to the holding methods and times in cooked foods served at foodservice institutions. When simmered pork in soy sauce and ham and cucumber salad were inoculated with S. typhimurium (7.00 logCFU/g) and tested according to holding methods and times, room temperature holding showed a continuous increase in S. typhimurium count as time passed, whereas 80$^{\circ}C$ heating table sharply reduced the count to 4.00 (logCFU/g) after 2hrs of holding and to zero after 6hrs, which suggested that all S. typhimurium were destroyed. However, 5$^{\circ}C$ refrigerator holding showed a count increase, although it wasis still lower than that at room temperature and at 10$^{\circ}C$ cold table holding, which suggested that S. typhimurium is comparatively resistive to low temperature.

전기 점화 방식에 있어서 초기 점화핵(Spark kernel) 성장의 정압특성 (The behavior of the early stage of the spark kernel growth at constant pressure surroundings)

  • 김현우;정인석;조경국
    • 오토저널
    • /
    • 제12권4호
    • /
    • pp.75-82
    • /
    • 1990
  • To study on the behavior of the early stage of the spark kernel at constant pressure condition, the expressions of the thermal properties such as compressibility factor, thermal conductivity, and electrical conductivity of the high temperature air were newly suggested. The newly suggested simple expressions of the thermal properties of the high temperature air showed good results. Under the assumption of constant pressure, one dimensional numerical analysis was executed by varying surrounding conditions and discharging current of electrical spark. Numerical results show tat high surrounding pressure suppresses the growth of the spark kernel but supplies much electrical energy into the air, on the other hand high surrounding temperature increases the growth of the spark kernel but supplies less electrical energy. Also the result shows that , in case of direct current discharge, deposited electrical energy is able to be expressed in linear function of time approximately.

  • PDF

신경회로망을 이용한 냉방부하예측에 관한 연구 (The Study on Cooling Load Forecast using Neural Networks)

  • 신관우;이윤섭
    • 설비공학논문집
    • /
    • 제14권8호
    • /
    • pp.626-633
    • /
    • 2002
  • The electric power load during the peak time in summer is strongly affected by cooling load, which decreases the preparation ratio of electricity and brings about the failure in the supply of electricity in the electric power system. The ice-storage system and heat pump system etc. are used to settle this problem. In this study, the method of estimating temperature and humidity to forecast the cooling load of ice storage system is suggested. And also the method of forecasting the cooling load using neural network is suggested. For the simulation, the cooling load is calculated using actual temperature and humidity, The forecast of the temperature, humidity and cooling load are simulated. As a result of the simulation, the forecasted data is approached to the actual data.

퍼지 논리를 이용한 일일 냉방부하 예측에 관한 연구 (A Study on Daily Cooling Load Forecast Using Fuzzy Logic)

  • 신관우;이윤섭
    • 제어로봇시스템학회논문지
    • /
    • 제8권11호
    • /
    • pp.948-953
    • /
    • 2002
  • The electric power load during the peak time in summer is strongly affected by cooling load, which decreases the preparation ratio of electricity and brings about the failure in the supply of electricity in the electric power system. The ice-storage system and heat pump system are possible solutions to settle this problem. In this study. the method of estimating temperature and humidity to forecast the cooling load of ice-storage system is suggested, then the method of forecasting the cooling load using fuzzy logic is suggested by simulating that the cooling load is calculated using actual temperature and humidity. The forecast of the temperature, humidity and cooling load are simulated, and it is shown that the forecasted data approach to the actual data. Operating the ice-storage system by the forecast of cooling load with night electric power will improve the ice-storage system efficiency and reduce the peak electric power load during the summer season as a result.

멀티존 온돌난방제어를 위한 필요공급온수온도 산출법에 관한 연구 (A Study on the Required Supply Water Temperature Calculating Method for the Control of Multizone Radiant Floor Heating System)

  • 최정민;이규남;류성룡;김용이;여명석;김광우
    • 설비공학논문집
    • /
    • 제19권1호
    • /
    • pp.77-85
    • /
    • 2007
  • One of the most common approaches to achieve better thermal comfort with the radiant floor heating system is supply water temperature control, which is that supply water temperature is varied with outdoor air temperature. But the application of this control method was not easy, because there has been no way to determine the supply water temperature. So in this study, a comprehensive, yet simple calculation method to find out the required supply water temperature is suggested by combining the building heat loss equation and the heat emission model of hydronic radiant floor heating system for single zone. And then using this calculation method, the multizone control method is suggested and confirmed through the thermal simulation. It is shown that indoor air temperature is stably maintained around the set point.

완화형 가유전체에서 전계인가에 따른 격자왜곡과 강유전물성의 상관관계 (Electric-Field-Induced Lattice Distortion and Related Properties in Relaxor Ferroelectrics)

  • 박재환;박재관;김윤호
    • 한국결정학회지
    • /
    • 제12권1호
    • /
    • pp.14-19
    • /
    • 2001
  • Effects of electric-field-induced lattice distortion on the polarization and strain were investigated in Pb(Mg/sub 1/3/Nb/sub 2/3)O₃ relaxor ferroelectric ceramics in the temperature range of -50℃∼90℃. The ratio of residual strain and polarization (S/sub r//P/sub r/ rarely depends on the temperature. However, the ratio of the electric field included strain and polarization (S/sub induced//P/sub induced/) increased as the temperature decreases below phase transition temperature. To explain these experimental results, a simple rigid ion model concentrating on only Bo/sub 6/ octahedron was suggested.

  • PDF

온도가 단립종벼의 Hysteresis에 미치는 영향 (Effect of Temperatrue on Sorption Hysteresis of Short Grain-Rough Rice)

  • 신명곤;김동철;민봉기;최홍식
    • 한국식품영양과학회지
    • /
    • 제20권3호
    • /
    • pp.281-283
    • /
    • 1991
  • The effect of temperature on hysteresis of rough rice grown in Korea was investigated. The maximum hysteresis effect of Chucheongbyeo paddy rice at 5$^{\circ}C$ amounted to an average 1.7% moisure content. However, their values at $25^{\circ}C$ and 4$0^{\circ}C$ averaged 1.2% and 0.7% moisture, respectively. It may be suggested that the exteents of hysteresis are affected by the temperature of hysteresis are affected by the temperature of adsorption and desorption.

  • PDF