• Title/Summary/Keyword: suctions

Search Result 46, Processing Time 0.026 seconds

A 6 m cube in an atmospheric boundary layer flow -Part 2. Computational solutions

  • Richards, P.J.;Quinn, A.D.;Parker, S.
    • Wind and Structures
    • /
    • v.5 no.2_3_4
    • /
    • pp.177-192
    • /
    • 2002
  • Computation solutions for the flow around a cube, which were generated as part of the Computational Wind Engineering 2000 Conference Competition, are compared with full-scale measurements. The three solutions shown all use the RANS approach to predict mean flow fields. The major differences appear to be related to the use of the standard $k-{\varepsilon}$, the MMK $k-{\varepsilon}$ and the RNG $k-{\varepsilon}$ turbulence models. The inlet conditions chosen by the three modellers illustrate one of the dilemmas faced in computational wind engineering. While all modeller matched the inlet velocity profile to the full-scale profile, only one of the modellers chose to match the full-scale turbulence data. This approach led to a boundary layer that was not in equilibrium. The approach taken by the other modeller was to specify lower inlet turbulent kinetic energy level, which are more consistent with the turbulence models chosen and lead to a homogeneous boundary layer. For the $0^{\circ}$ case, wind normal to one face of the cube, it is shown that the RNG solution is closest to the full-scale data. This result appears to be associated with the RNG solution showing the correct flow separation and reattachment on the roof. The other solutions show either excessive separation (MMK) or no separation at all (K-E). For the $45^{\circ}$ case the three solutions are fairly similar. None of them correctly predicting the high suctions along the windward edges of the roof. In general the velocity components are more accurately predicted than the pressures. However in all cases the turbulence levels are poorly matched, with all of the solutions failing to match the high turbulence levels measured around the edges of separated flows. Although all of the computational solutions have deficiencies, the variability of results is shown to be similar to that which has been obtained with a similar comparative wind tunnel study. This suggests that the computational solutions are only slightly less reliable than the wind tunnel.

Influence of Propofol, Isoflurane and Enflurance on Levels of Serum Interleukin-8 and Interleukin-10 in Cancer Patients

  • Liu, Tie-Cheng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.16
    • /
    • pp.6703-6707
    • /
    • 2014
  • Objective: To observe the influence of propofol, isoflurane and enflurance on interleukin-8 (IL-8) and IL-10 levels in cancer patients. Methods: Ninety cancer patients with selective operation from March 2011 to May 2014 were randomly divided into group A (34 cases), group B (28 cases) and group C (28 cases). Intramuscular injections of scopine hydrochloride and phenobarbital sodium were routinely conducted to 3 groups. After general anesthesia was induced, tracheal intubations were given. During the maintenance of anesthesia, 0.5~1.0 mg/kg propofol was intravenously injected to group A discontinuously, while continuous suctions of isoflurane and enflurance were subsequently performed to group B and C correspondingly. Clinical outcomes, postoperative complications as well as serum IL-8 and IL-10 levels before operation (T0), at the time of skin incision (T1), 3 h after the beginning of the operation (T2) and 24 h (T3) and 72 h (T4) after the operation were observed among 3 groups. Results: Operations in all groups were successfully completed. The rates of surgery associated complications were 8.82% (3/34), 7.14% (2/28) and 7.14% (2/28) in group A, B and C, respectively, and there were no significant differences (P>0.05). Serum IL-8 and IL-10 levels increased gradually from the beginning of the operation and reached the peak at T3, and were evidently higher at each time point than at T0 (P<0.01). At T1, serum IL-8 and IL-10 levels had no significant differences among 3 groups (P>0.05), but the differences were significant at T2, T3 and T4 (P<0.05). Moreover, correlation analysis suggested that serum IL-8 level was in positive relation with IL-10 level (r=0.952, P<0.01). Conclusions: Propofol, which is better in inhibiting serum IL-8 secretion and improving IL-10 secretion than isoflurane and enflurance, can be regarded as a preferable anesthetic agent in inhibiting traumatic inflammatory responses.

Density Effect on Suction Stress Characteristics of Compacted Weathered Gneiss Soils (편마풍화토의 다짐밀도에 따른 불포화 흡수응력 특성)

  • Park, Seong-Wan;Kim, Byeong-Su;Kwon, Hong-Gi;Lim, Jae-Seong
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.8
    • /
    • pp.15-25
    • /
    • 2013
  • In order to examine the unsaturated shear strength characteristics of compacted weathered gneiss soils, the constant water content compression (CWCC) test was carried out. Specimens were made by static compaction under two densities conditions. The shear behavior in accordance with an initial suction obtained by varying initial degrees of saturation was evaluated. The suction could be directly measured by the use of the ceramic disk and the pore-water pressure transducer. The results of the peak shear strength from the CWCC test were examined using the relationship with Mp line from triaxial test under the saturated state, that is, by means of the suction stress which was calculated using the measured suction. In addition, the applicability of the suctions stress to the unsaturated shear behaviour of compacted weathered gneiss soils was discussed by applying Suction stress-SWCC Method (SSM).

Construction of Super-block Unit Curtain Wall for High-rise Buildings Utilizing a Specialized Installing Equipment (전용 양중틀을 활용한 초고층 건물의 슈퍼블럭 유닛 커튼월 시공)

  • Chung, Sam-Yong;Lee, Sang-Heon;Ohk, Young-Mu
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2004.11a
    • /
    • pp.174-181
    • /
    • 2004
  • We will introduce a method of construction of super-block curtain wall applied to Tower Palace III which is the highest high-rise complex building in Korea. Up-up method is utilized on Tower Palace III to shorten the term of works and it is that the curtain walls for the belt wall part are installed after the rests. The belt wall structure increases the horizontal structural stiffness of the building. The method of construction of super-block curtain wall is developed and used to raise and install the curtain wails of the belt wall floor. It is that the large block of curtain walls corresponding to three stories is fabricated on the ground in advance and the block is installed at a time by a tower crane. Specialized installing equipment :,s newly developed and applied to install the super-block. curtain wail. The curtain wall of the upper floor of the belt wall part is installed after the super-block. The installing equipment for this floor is developed utilizing a mini excavator and vacuum suctions. The application of this method had made it possible to omit the setting up the scaffold and financial profits such as the shortening of the terms of works was realized. The safety of works was secured and the productivity was also improved.

  • PDF

A Simple Method for Estimating Wetting Path of Soil Water Characteristic Curve on Unsaturated Soils (불포화지반의 습윤과정 함수특성곡선 추정을 위한 간편법)

  • Park, Hyun-Su;Kim, Byeong-Su;Park, Seong-Wan
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.6
    • /
    • pp.37-48
    • /
    • 2017
  • Soil-water characteristic curve (SWCC) has been widely used to estimate the shear strength and coefficient of permeability for unsaturated soils. In general, it is divided into the drying path in which the water is discharged and the wetting path in which the water is permeated, and it has a hysteresis indicating different suctions at the same volumetric water content. In reality the field behavior of unsaturated soils is much closer to the wetting path during the infiltration. The drying path has been practically used for various analyses because obtaining the wetting path takes longer than the drying path. Although many approaches for estimating wetting path have been studied till now, these are complex and do not fit well. Therefore, a simple method for estimating wetting path based on empirical approach in this study is proposed in unsaturated soils, and a feasibility study is conducted as well.

Noise and Room Acoustic Conditions in a Tertiary Referral Hospital, Seoul National University Hospital

  • Cho, Wan-Ho;Jeong, Cheol-Ho;Chang, Ji-Ho;Lee, Seong-Hyun;Park, Moo Kyun;Suh, Myung-Whan;Han, Jae Joon
    • Journal of Audiology & Otology
    • /
    • v.23 no.2
    • /
    • pp.76-82
    • /
    • 2019
  • Background and Objectives: Noise levels and room acoustic parameters at a tertiary referral hospital, Seoul National University Hospital (SNUH) in Korea, are investigated. Materials and Methods: Through a questionnaire, acoustically problematic rooms are identified. Noise levels in emergency rooms (ERs) and intensive care units (ICUs) are measured over about three days. Acoustically critical and problematic rooms in the otolaryngology department are measured including examination rooms, operating rooms, nurse stations, receptions, and patient rooms. Results: The A-weighted equivalent noise level, LAeq, ranges from 54 to 56 dBA, which is at least 10 dB lower than the noise levels of 65 to 73 dBA measured in American ERs. In an ICU, the noise level for the first night was 66 dBA, which came down to 56 dBA for the next day. The noise levels during three different ear surgeries vary from 57 to 62 dBA, depending on the use of surgical drills and suctions. The noise levels in a patient room is found to be 47 dBA, while the nurse stations and the receptions have high noise levels up to 64 dBA. The reverberation times in an operation room, examination room, and single patient room are found to be below 0.6 s. Conclusions: At SNUH, the nurse stations and receptions were found to be quite noisy. The ERs were quieter than in the previous studies. The measured reverberation times seemed low enough but some other nurse stations and examination rooms were not satisfactory according to the questionnaire.

Shear Strength-strain Behavior of Unsaturated Weathered Soil (SM) (화강풍화토(SM soil)의 불포화 전단거동 분석)

  • Jeong, Sang-Seom;Lee, Seong-Cheol;Jeong, Seung-Hwa
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.2
    • /
    • pp.5-13
    • /
    • 2022
  • The unsaturated behavior of sandy silt (SM soil) was investigated experimentally. Special attention was given to the stress-strain behavior of unsaturated weathered soil (SM) prior to failure and behavior at failure under monotonic loading. A sandy silt (SM) weathered soil containing a certain amount of fine contents distributed in Korea, was chosen to form samples with different densities of Dr=25%, 60%, and 75%. and matric suctions. The isotopically Consolidated Drain test (CD-test) was performed to maintain a constant matric suction during the shearing process. Based on the experimental results, it was qualitatively identified that the higher the relative density, the greater the virtual friction angle (ϕb) value and AEV (Air Entry Value) were induced. Also it is found that the internal friction angle (ϕ') is more or less constant. even if the matric suction is increased.

Noise and Room Acoustic Conditions in a Tertiary Referral Hospital, Seoul National University Hospital

  • Cho, Wan-Ho;Jeong, Cheol-Ho;Chang, Ji-Ho;Lee, Seong-Hyun;Park, Moo Kyun;Suh, Myung-Whan;Han, Jae Joon
    • Korean Journal of Audiology
    • /
    • v.23 no.2
    • /
    • pp.76-82
    • /
    • 2019
  • Background and Objectives: Noise levels and room acoustic parameters at a tertiary referral hospital, Seoul National University Hospital (SNUH) in Korea, are investigated. Materials and Methods: Through a questionnaire, acoustically problematic rooms are identified. Noise levels in emergency rooms (ERs) and intensive care units (ICUs) are measured over about three days. Acoustically critical and problematic rooms in the otolaryngology department are measured including examination rooms, operating rooms, nurse stations, receptions, and patient rooms. Results: The A-weighted equivalent noise level, LAeq, ranges from 54 to 56 dBA, which is at least 10 dB lower than the noise levels of 65 to 73 dBA measured in American ERs. In an ICU, the noise level for the first night was 66 dBA, which came down to 56 dBA for the next day. The noise levels during three different ear surgeries vary from 57 to 62 dBA, depending on the use of surgical drills and suctions. The noise levels in a patient room is found to be 47 dBA, while the nurse stations and the receptions have high noise levels up to 64 dBA. The reverberation times in an operation room, examination room, and single patient room are found to be below 0.6 s. Conclusions: At SNUH, the nurse stations and receptions were found to be quite noisy. The ERs were quieter than in the previous studies. The measured reverberation times seemed low enough but some other nurse stations and examination rooms were not satisfactory according to the questionnaire.

A Comparative Study on Closed vs. Open Endotracheal Suctioning on the Newborn Infants Treated with Ventilator (인공호흡기 사용 신생아의 폐쇄형과 개방형 기관흡인에 관한 연구)

  • Park, Jeong-Won;Park, Yeong-Ae
    • 아동간호학회:학술대회논문집
    • /
    • 1997.11a
    • /
    • pp.61-74
    • /
    • 1997
  • Endotracheal suctioning is a routine procedure used for clearing secretions from the airway of the intubated infant. This procedure is not without complications. Endotracheal suctioning has been associated with decreases in $PaO_2$, decreases in systemic venous oxygenation, alterations in mean arterial Pressure, disturbances in cardiac rhythm and development of nosocomial pneumonia. So several endotracheal suctioning techniques have been developed to prevent these blown complications. Another method of Endotracheal suctioning eliminates the risk associated with disconnecting the infant from the ventilatior to perform the suctioning procedure. Studies examining closed endotracheal suctioning methods reported that the closed method results in less arterial oxygen saturation, and less systemic venous oxygen desaturation. However those studies have focused on adult patients, and there have been no published studies for newborn infants. The specific purpose of this study is to investigate the two methods and to make a comparison in terms of (1)variations in $SaO_2$, heart rate, and respiration rate appeared before and after the endotracheal suctioning; (2)difference in occurrence of nosocomial infection; (3)difference in recovery time to arrive at pre-suction baseline after suctioning and in nursing time taken for the suctioning. The present study is based on the data obtained from two groups of newborn infants : one group comprises 8 infants with closed suctioning (a total of 304 suctions) among 17 infants treated with ventilator and the other group 9 infants with open method (a total of 629 suctions). The data were analyzed using the SPSS statistical program package. As the distribution test on dependent variables with the Skewnesser Shapiro Wilk test showed an asymmetric distribution, the Wilcoxon Matched-pairs Singled- Ranks test was used for the test of variations in $SaO_2$, heart rate, and respiration rate appeared before and after the endotracheal suctioning. The difference in $SaO_2$ recovery time and nursing time was analyzed with the Mann-Whitney U-Test. The difference in physiologic consequences and occurrence of nosocomial infection between the two groups was analyzed with the Fisher's Exact Test. The results of the study are summarized as follows. For the hypothesis 1 (There would be a difference in $SaO_2$, heart rate, and respiration rate before and after suctioning between the two suctioning methods), the difference in $SaO_2$ turns out to be statistically significant (P=0.015), but heart rate and respiration rate do not procedure a notable difference (P=0.630). The hypothesis 2 (There would be a difference in rates at which a complication arises after suctioning between the two groups) does not prove to be statistically valid (P=0.246). For the hypothesis 3(There would be a difference in $SaO_2$ recovery time and nursing time between the two groups), the average $SaO_2$ recovery time after suctioning turned out to have somewhat significant difference (P=0.064), however the difference in nursing time taken for the suctioning was not statistically significant (P=0.610). The analyses indicate that the closed endotracheal suctioning is more efficient as compared with the open method, in maintaining pre-suction baseline $SaO_2$ and a rapid recovery of newborn infants. Based on these results we suggust to apply the closed method to newborn infants in the ventilation treatment. We also suggest to extend the investigation to include the comparison of suction cost taking into account the case in which a complication arises after endotracheal suctioning between the two groups.

  • PDF

Estimation on Unsaturated Hydraulic Conductivity Function of Jumoonjin Sand for Various Relative Densities (주문진 표준사의 상대밀도에 따른 불포화 투수계수함수 산정)

  • Song, Young-Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.6
    • /
    • pp.2369-2379
    • /
    • 2013
  • The Soil-Water Characteristics Curve (SWCC) is affected by the initial density of soil under unsaturated condition. Also, the characteristic of hydraulic conductivity is changed by the initial density of soil. To study the effect of initial density of unsaturated soil, SWCC and the Hydraulic Conductivity Function (HCF) of Jumoonjin sand with various relative densities, 40%, 60% and 75% were measured in both drying and wetting processes. As the results of SWCC estimated by van Genuchten (1980) model, the parameter related to Air Entry Value(AEV), ${\alpha}$ in the wetting process is larger than that in drying process, but the parameters related to the SWCC slope, n and the residual water content, m are larger than those in wetting process. The AEV is increased or Water Entry Value (WEV) is decreased with increasing the relative density of sand. The AEV is larger than the WEV at the same relative density of sand. As the results of HCF estimated by van Genuchten (1980) model which is one of the parameter estimation methods, the unsaturated hydraulic conductivity maintained at a saturated one in the low level of matric suctions and then suddenly decreased just before the AEV or the WEV. The saturated hydraulic conductivity in drying process is larger than that in wetting process. The saturated hydraulic conductivity is decreased with increasing the relative density of sand in both drying and wetting processes. Also, the hysteresis in unsaturated HCFs between drying and wetting process was occurred like the hysteresis in SWCCs. According to the test results, the AEV on SWCC is decreased and the saturated hydraulic conductivity is increased with increasing the initial density. It means that SWCC and HCF are affected by the initial density in the unsaturated soil.