• Title/Summary/Keyword: suction speed

Search Result 169, Processing Time 0.022 seconds

Effect of Incidence Angle on Turbine Blade Heat Transfer Characteristics (II) - Blade Surface - (입사각 변화에 따른 터빈 블레이드에서의 열전달 특성 변화 (II) - 블레이드 표면 -)

  • Rhee, Dong-Ho;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.4
    • /
    • pp.357-366
    • /
    • 2007
  • The present study investigated local heat/mass transfer characteristics on the surface of the rotating turbine blade with various incidence angles. The experiments are conducted in a low speed annular cascade with a single stage turbine. The blade has a flat tip with the mean tip clearance of 2.5% of the blade chord. A naphthalene sublimation method is used to measure detailed mass transfer coefficient on the blade. At design condition, the inlet Reynolds number is $Re_c=1.5{\times}10^5$ which results in the blade rotation speed of 255.8 rpm. Also, the effect of off-design condition is examined with various incidence angles between $-15^{\circ}$ and $+7{\circ}$. The results indicated that the incidence angle has significant effects on the blade surface heat transfer. In mid-span region, the laminar separation region on the pressure side is reduced and the laminar flow region on the suction side shrinks with increasing incidence angle. Near the tip, the effect of tip leakage flow increases in span wise and axial directions as the incidence angle decreases because the tip leakage flow is formed near the suction side surface. However, the effect of tip leakage flow is reduced with positive incidence angle.

Improvement of Pump Performance and Suppression of Cavitation in a Centrifugal Pump (원심펌프의 성능개선과 캐비테이션 억제에 관한 연구)

  • Choi, Young-Do;Kurokawa, Junichi
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.1
    • /
    • pp.18-25
    • /
    • 2008
  • Recent trends of a centrifugal pump are high speed in rotation and high pressure in head with high efficiency to meet the demands of industries. However, the newly developed pumps make trouble of pressure pulsation in the pumping system by performance instability of the pump. Moreover, cavitation, which is a main obstacle of high rotational speed in the pump, occurring in an impeller gives serious damages to the impeller and casing wall. The purpose of present study is not only to develop a simple method to improve pump performance but also to suppress the occurrence of cavitation in the centrifugal pump by use of J-Groove. J-Groove is a shallow groove installed on the casing wall in the meridional direction. The application of J-Groove to a centrifugal pump with a new type impeller of "semi-closed impeller" has proved its effectiveness as a useful countermeasure of the unstable pump performance and cavitation. The results show that the combination of semi-closed impeller and J-Groove can be applied successfully and improves both the pump performance and suction performance.

The Study of the Separation Efficiency of Wind Power Selector Using Computational Fluid Dynamics (전산유체역학을 이용한 풍력 선별기의 선별효율 연구)

  • Lee, Keon Joo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.21 no.3
    • /
    • pp.74-81
    • /
    • 2013
  • In this study, the separation efficiency of wind power selector (the direction of the air flow of the air to perform gravity separation method) of municipal solid waste which was landfilled was investigated to reduce amount of waste that is designed to increase the recycling rate of wastes for the ANSYS CFX Program's numerical methods with wind through the separator. When a suction device designed to suction 1000mL of a plastic bag, the separation efficiency was 100% and when the wind speed was 0.9 m /sec or more and when the wind speed was 1.6 m / sec or more, the efficiency of plastic bottles in a mixture of 500mL and 1500mL plastic bottle waste was 100% and the aluminum screening efficiency of 250mL aluminum can was 100 % when the wind speed was 2.3 m / sec. In the last, 5mm thick compressed aluminum can efficiency was 90 % when the wind speed was 2.4 m / sec.

The property change of rotating stall in one-stage axial compressor according to rotor's rotating speed variation (동익 회전속도 변화에 따른 1단 축류 압축기 선회실속의 특성변화 연구)

  • Choi, Minsuk;Baek, Je-Hyun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.258-263
    • /
    • 2002
  • A numerical analysis using 2-D unsteady compressible program is conducted to explain characteristics of rotating stall such as rotating speed and number of stall cells in an one-stage axial compressor. Unlike an axial compressor which has only a rotor, in one-stage axial compressor a rotating stall is generated by rotor/stator interaction and tack pressure rising without any artificial disturbance and modeling. As a back pressure is raised, the separation of suction side at blades is increased uniformly, but because of the discrepancy of blockage effect by stator, the disturbances are generated to form a stall cell. Once the stall cell is formed, regularly the stall cell are rotating through rotor blades. When the speed of rotor is design speed the rotating speed of stall cell is $83.3\%$ of rotor rotating speed. When the speed of rotor is $80\%$ of design speed, the speed of rotating stall is $88.2\%$ of rotor speed. The number of generated stall cell are also varied for rotor speed and back pressure.

  • PDF

A Study on the Performance Analysis of Automotive Air Conditioning System (자동차용 에어컨 시스템의 성능해석에 관한 연구)

  • 이대웅;유성연
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.4
    • /
    • pp.304-314
    • /
    • 2002
  • Performance analysis of the automotive air-conditioning system is conducted by using computer simulation, and performance tests are carried out by using the climate wind tunnel in order to verify simulation. Evaporator and condenser were modeled by using empirical correlation which was obtained from calorimeter data, and compressor was modeled by using map based method. The steady state thermodynamic conditions of refrigerant satisfying mass and energy balance were assumed in the simulation program for automotive airconditioning system. The system performance was analyzed by finite difference method until differential air enthalpy between evaporator inlet and outlet becomes converged. Simulation results are in good agreement with experimental results at most operating conditions. Variation of discharge temperature and pressure of compressor, outlet temperature of evaporator, cooling capacity, and COP were investigated in term of air volume flow rate for evaporator, compressor capacity, compressor speed, superheat of thermostatic expansion valve, and diameter of suction line.

Design of Cavitation-Resistive Pump Inducer (공동현상을 고려한 펌프 인듀서 설계)

  • Jung, Keun-Hwa;Ahn, Kwang-Woon;Lee, Seungbae;Kim, Jin-Hwa;Kang, Shin-Hyoung
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.185-190
    • /
    • 2001
  • The cavitation causes suction performance and efficiency of the high-speed pump to be reduced significantly To diminish these effects, the inducer has been used. Most of the inducer is designed at a maximum efficiency point of the pump, therefore suction performance drop due to effects of flow separation and inlet inverse flow is often observed at off-design point. The objective of this study is to find out the cavitation modes at various conditions by applying event detection technique and to design an inducer reducing cavitation. The pressure fluctuations at each cavitating condition were measured at inducer inlet and outlet locations using pressure transducers, which were located 90 degrees apart from each other to identify the cavitation modes. The time-frequency characteristics were analyzed by using Choi-williams distribution. In the second part of this paper, the inducer design method which uses nominal performance characteristic and onset condition of cavitation is introduced and applied to real situation.

  • PDF

Flow Field Analysis inside Intake Nozzles of a Household Vacuum Cleaner

  • Daichin Daichin;Lee Sang Joon
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.733-736
    • /
    • 2002
  • The inside configuration of intake nozzle of vacuum cleaner greatly affects the dust-collection efficiency and acoustic-noise effect generated from flow separation Interaction between high-speed flow and internal structure. In order to improve the performance of the vacuum cleaner, flow fields inside the intake nozzles were investigated using flow visualization and FIV (Particle Image Vetocimetry) technique. The measurement to aerodynamic power, suction efficiency and noise level were also carried out. Valuable information was obtained from the experiments, revealing how to modify the intake nozzle. In this paper, the results of visualization, velocity distribution of flow fields, aerodynamic power, suction efficiency and noise level are discussed.

  • PDF

이젝터가 부착된 냉동시스템의 성능실험

  • 이원희;김윤조;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.10
    • /
    • pp.993-1001
    • /
    • 2001
  • Experimental investigation on the performance of dual-evaporator refrigeration system with an ejector has been carried out. In this study, a hydrofluorocarbon (HFC) refrigerant R134a is chosen as a working fluid. The condenser and two-evaporators are made as concentric double pipes with counter-flow type heat exchangers. Experiments were performed by changing the inlet and outlet temperatures of secondary fluids entering condenser, high-pressure evaporator and low-pressure evaporator at test conditions keeping a constant compressor speed. When the external conditions (inlet temperatures of secondary fluid entering condenser and one evaporator) are fixed, results show that coefficient of performance (COP) increases as the inlet temperature of the other evaporator rises. It is also shown that the COP decreases as the mass flaw rate ratio of suction fluid to motive fluid increases. The COP of dual-evaporator refrigeration system with an ejector is superior to that of a single-evaporator vapor compression system by 3 to 6%.

  • PDF

Experimental Study on the Performance of Refrigeration System with an Ejector

  • Lee, Won-Hee;Kim, Yoon-Jo;Kim, Min-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.4
    • /
    • pp.201-210
    • /
    • 2002
  • Experimental investigation on the performance of dual-evaporator refrigeration system with an ejector has been carried out. In this study, a hydrofluorocarbon (HFC) refrigerant R134a is chosen as a working fluid. The condenser and two-evaporators are made as concentric double pipes with counter-flow type heat exchangers. Experiments were peformed by changing the inlet and outlet temperatures of secondary fluids entering condenser, high-pressure evaporator and low-pressure evaporator at test conditions keeping a constant compressor speed. When the external conditions (inlet temperatures of secondary fluid entering condenser and one of the evaporators) are fixed, results show that coefficient of performance (COP) increases as the inlet temperature of the other evaporator rises. It is also shown that the COP decreases as the mass flow rate ratio of suction fluid to motive fluid increases. The COP of dual-evapo-rator refrigeration system with an ejector is superior to that of a single-evaporator vapor compression system by 3 to 6%.

A Study on the Superheat Control of a Tandem-type Airconditioner by Using a Variable Speed Outdoor Fan (변속실외기펜을 사용한 텐텀형냉방기의 과열도제어에 관한 연구)

  • Kim, Jae-Hyun;Han, Do-Young
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.474-479
    • /
    • 2005
  • For the safe operation of an air conditioner, the liquid car η 'over to compressors should be minimized and compressors should be operated in the specified region of suction and discharge pressures recommended by compressor manufactures. In this study, a capillary assisted tandem-type airconditioner was considered. A variable speed outdoor fan was used to control operating points of the system. Test results showed the possibilities to move system operating points to the safe region by controlling the speed of an outdoor fan.

  • PDF