• Title/Summary/Keyword: substandard

Search Result 61, Processing Time 0.024 seconds

GIS-Based Research on Location and Spatial Characteristics of the Slum in Daejeon

  • Kim, Dongseon;Mo, Seonhee
    • International Journal of Contents
    • /
    • v.16 no.2
    • /
    • pp.30-40
    • /
    • 2020
  • This study performed GIS and statistical analyses on the location and spatial characteristics of the slum in Daejeon. Spatial data of 648 slum residents in Daejeon were collected and 131 residents among them were surveyed. The results showed the trends of higher rent, lower social exclusion and closer neighboring relations in slum center than the surrounding areas, which could be interpreted as the interrelated multilateral effects of the micro- (housing), meso- (relations), exo- (community) and macro- (government policy) systems. The strong bonds among neighbors and various supports from social service facilities elevated the slum area's rent and diminished residents' social exclusion more than housing conditions (for instance, poor hygiene and low safety). Slum tenants willingly paid a premium for their substandard housings and refused moving to governmentally provided modern housing units. In urban development, administrative authorities need to be cautious about slum uprooting. Much rather an alternative renewal approach is needed which protects the slum's intimate relations while improving its overall living standards.

Cyclic load testing and numerical modeling of concrete columns with substandard seismic details

  • Marefat, Mohammad S.;Khanmohammadi, Mohammad;Bahrani, Mohammad K.;Goli, Ali
    • Computers and Concrete
    • /
    • v.2 no.5
    • /
    • pp.367-380
    • /
    • 2005
  • Recent earthquakes have shown that many of existing buildings in Iran sustain heavy damage due to defective seismic details. To assess vulnerability of one common type of buildings, which consists of low rise framed concrete structures, three defective and three standard columns have been tested under reversed cyclic load. The substandard specimens suffered in average 37% loss of strength and 45% loss of energy dissipation capacity relative to standard specimens, and this was mainly due to less lateral and longitudinal reinforcement and insufficient sectional dimensions. A relationship has been developed to introduce variation of plastic length under increasing displacement amplitude. At ultimate state, the length of plastic hinge is almost equal to full depth of section. Using calibrated hysteresis models, the response of different specimens under two earthquakes has been analyzed. The analysis indicated that the ratio between displacement demand and capacity of standard specimens is about unity and that of deficient ones is about 1.7.

Quality of Breast Cancer Early Detection Services Conducted by Well Woman Clinics in the District of Gampaha, Sri Lanka

  • Vithana, Palatiyana Vithanage Sajeewanie Chiranthika;Ariyaratne, M.A.Y.;Jayawardana, P.L.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.1
    • /
    • pp.75-80
    • /
    • 2013
  • Background: Breast cancer is the most common cancer diagnosed in females in Sri Lanka and early detection can lead to reduction in morbidity and mortality. Aim: To evaluate selected aspects of breast cancer early detection services implemented through well woman clinics (WWCs) in the Gampaha District. Methods: The study consisted of two components. A retrospective descriptive arm assessed clinical breast examination (CBE) coverage of target age group women (TGW) of 35-59 years in all the WWCs in Gampaha district over 2003-2007. A cross sectional descriptive study additionally assessed quality of breast cancer early detection services. The Lot Quality Assurance Sampling (LQAS) technique was used to decide on the lot size and threshold values, which were computed as twenty and six clinics. Checklists were employed in assessing coverage, physical facilities and clinic activities. Client satisfaction on WWC services was assessed among 200 TGW attending 20 WWCs using an interviewer-administered questionnaire. Results: CBE coverage in the Gampaha district increased only from 1.1-2.2% over 2003-2007. With regard to physical facilities, the number of clinics that were rated substandard varied between 7-18 (35-90%). The items that were lacking included dust bins, notice boards, stationary, furniture and linen, and cleanliness of outside premises and toilets. With regard to clinic activities, punctuality of staff, late commencement of clinics, provision of health education, supervision, CBE and breast self-examination (BSE) were substandard in 7-20 clinics (35-100%). Client satisfaction for WWC services was 45.2% (IQR: 38.7-54.8%) and only 11% had a score of ${\geq}70%$, the cut off set for satisfaction. Conclusions: Breast cancer early detection service coverage in the Gampaha district remained low (2.2%) in 2007, 11 years after commencing WWCs. All 20 clinics were substandard for overall CBE and BSE.

A study on inspection system for brake pad (브레이크패드 검사 시스템 구축에 관한 연구)

  • Kim, Tae-Eun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.3
    • /
    • pp.403-408
    • /
    • 2013
  • In this paper, we propose to develop an inspection system that recognizes surface cracks on the brake pad and the types of brake pads of each car during the production process, on a conveyor belt. The brake pad is made from a mixture of materials, using high-heat and pressure. Therefore, the brake pad can be cracked and damaged on the surface during production. Our goal is to develop an effective detection system and application software to detect substandard product. A shadow is generated when the artificial light shines on the damaged of the surface of pad. Using the computer vision algorithm that is proposed we can detect the substandard product. Results from experiments confrim the performance of the proposed algorithm.

Experimental investigation of existing R/C frames strengthened by high dissipation steel link elements

  • Karalis, Apostolos A.;Stylianidis, Kosmas C.
    • Earthquakes and Structures
    • /
    • v.5 no.2
    • /
    • pp.143-160
    • /
    • 2013
  • This paper presents the results of an experimental program concerning the efficiency of a specific strengthening technique which utilizes a small steel link element connected to the R/C frame through bracing elements. Brittle types of failure, especially at the connections between steel and concrete elements, can be avoided by appropriate design of the local details. Five single storey one bay R/C frames scaled 1:3 were constructed according to older codes with substandard details. The first one was a typical bare reference frame. The other four were identical to the first one, strengthened by steel bracing elements. The behavior of the strengthened frames is described with respect to the reference bare frame. The concrete frames were constructed according to older code provisions by the use of smooth steel bars, low strength concrete, sparsely spaced stirrups and substandard details. The strengthening scheme aimed to the increase of both strength and deformation capacity of the original R/C frame. The inelastic deformations are purposely concentrated to a short steel link element connecting the steel bracing to the R/C frame. The results show that the steel link element can increase considerably the strength and the energy dissipation capacity of the frame.

Performance evaluation of suspended ceiling systems using shake table test

  • Ozcelik, Ozgur;Misir, Ibrahim S.;Saridogan, Serhan
    • Structural Engineering and Mechanics
    • /
    • v.58 no.1
    • /
    • pp.121-142
    • /
    • 2016
  • The national standard being used in Turkey for suspended ceiling systems (SCS) regulates material and dimensional properties but does not contain regulations regarding installation instructions which cause substandard applications of SCSs in practice. The lack of installation instructions would potentially affect the dynamic performance of these systems. Also, the vast majority of these systems are manufactured using substandard low-quality materials, and this will inevitably increase SCS related damages during earthquakes. The experimental work presented here focuses on the issue of dynamic performance of SCSs with different types of carrier systems (lay-on and clip-in systems), different weight conditions, and material-workmanship qualities. Moreover, the effects of auxiliary fastening elements, so called seismic perimeter clips, in improving the dynamic performance of SCSs were experimentally investigated. Results show that clip-in ceiling system performs better than lay-on system regardless of material and workmanship qualities. On the other hand, the quality aspect becomes the most important parameter in affecting the dynamic performance of lay-on type systems as opposed to tile weights and usage of perimeter clips. When high quality system is used, tile weight does not change the performance of lay-on system, however in poor quality system, tile weight becomes an important factor where heavier tiles considerably decrease the performance level. Perimeter clips marginally increase the dynamic performance of lay-on ceiling system, but it has no effect on the clip-in ceiling system under the shaking levels considered.

Effectiveness of R/C jacketing of substandard R/C columns with short lap splices

  • Kalogeropoulos, George I.;Tsonos, Alexander G.
    • Structural Monitoring and Maintenance
    • /
    • v.1 no.3
    • /
    • pp.273-292
    • /
    • 2014
  • The effectiveness of a retrofitting method for concrete columns with particular weaknesses is experimentally evaluated and presented in this paper. Structural deficiencies namely the inadequacy of transverse reinforcement and short length of lap splices are very common in columns found in structures built prior to the 1960s and 1970s. Recent earthquakes worldwide have caused severe damages and collapses of these structures. Nevertheless, the importance of improving the load transfer capacity between the deficiently lap-spliced bars is usually underestimated during the strengthening procedures applied in old buildings, though critical for the safety of the residents' lives. Thus, the seismic performance of the enhanced columns is frequently overestimated. The retrofitting approach presented herein involves reinforced concrete jacketing of the column sub-assemblages and welding of the lap-spliced bars to prevent the splice failure and conform to the provisions of modern design Codes. The cyclic lateral loading response of poorly confined original column specimens with insufficient lap splices and the seismic behavior of the retrofitted columns are compared. Test results clearly demonstrate that the retrofitting procedure followed is an effective way of significantly improving the seismic performance of substandard columns found in old buildings.

Seismic repair of captive-column damage with CFRPs in substandard RC frames

  • Tunaboyu, Onur;Avsar, Ozgur
    • Structural Engineering and Mechanics
    • /
    • v.61 no.1
    • /
    • pp.1-13
    • /
    • 2017
  • The effectiveness of the repair scheme for the damaged captive-columns with CFRPs (Carbon Fiber Reinforced Polymer) was investigated in terms of response quantities such as strength, ductility, dissipated energy and stiffness degradation. Two 1/3 scale, one-story one-bay RC (Reinforced Concrete) frames were designed to represent the substandard RC buildings in Turkish building stock. The first one, which is the reference specimen, is the bare frame without infill wall. Partial infill wall with opening was constructed between the columns of the second frame and this caused captive column defect. Severe damage was observed with the concentration of shear cracks in the second specimen columns. Then, the damaged members were repaired by CFRP wrapping and retested. For the three test series, similar reversed cyclic lateral displacement under combined effect of axial load was applied to the top of the columns. Overall response of the bare frame was dominated by flexural cracks. Brittle type of shear failure in the column top ends was observed in the specimen with partial infill wall. It was observed that former capacity of damaged members of the second frame was recovered by the applied repair scheme. Moreover, ultimate displacement capacity of the damaged frame was improved considerably by CFRP wrapping.

Strengthening of deficient RC joints with diagonally placed external C-FRP ropes

  • Karayannis, Chris G.;Golias, Emmanouil
    • Earthquakes and Structures
    • /
    • v.20 no.1
    • /
    • pp.123-132
    • /
    • 2021
  • Deficient beam-column joints of reinforced concrete (RC) structures designed to older practices and codes often lead to destructive local or global failures. A strengthening technique for these joints based on the use of the new and innovative Carbon-FRP (C-FRP) ropes is presented and investigated. The C-FRP ropes are diagonally placed in superficial notches on the two sides of the joint. Two full scale external substandard joint subassemblages with the same characteristics, one unstrengthened and one strengthened with diagonally applied C-FRP ropes, are constructed and tested in cyclic loading. Special attention has been given to the elaboration of the acquired test measurements. The extracted conclusions are based on the comparative study of the hysteretic responses of the specimens, the observed maximum load envelopes, the comparisons of the joint body shear deformations as measured using diagonally mounted LVTDs, the calculated nominal principal stresses developed in the joint regions, the assessed joint damage as expressed by the damage index by Park and Ang and finally the calculated values of the equivalent damping ratio. From these comparisons it is concluded that application of diagonally mounted C-FRP ropes on the two sides of the joint body of exterior connections is an efficient easy-to-apply technique for the strengthening of substandard RC joints.