• Title/Summary/Keyword: subjective wear sensation

Search Result 68, Processing Time 0.033 seconds

The Psycho-physiological Response of Polyethylene Terephthalate Irradiated by Ultra-Violet: Subjective Fabric Hand and Wear Comfort

  • Choi, Hae-Young;Lee, Jung-Soon
    • Fibers and Polymers
    • /
    • v.7 no.4
    • /
    • pp.442-445
    • /
    • 2006
  • The purpose of this study was to compare the subjective fabric hand evaluation and wear comfort of PET treated by Ultraviolet and to evaluate the subjective results from the investigation of microclimate temperature. The subjective hand evaluation was performed by 20 subjects (age: 20-25) with 5-point scale questionnaires to investigate the change of PET knit fabrics treated for different times, specifically, 0, 30 and 90 minutes. The questionnaires were composite with 8 questions; roughness, smoothness, wetness, stiffness, coolness, touch, preference, and comfort. In order to evaluate sensations of wear comfort, we made garments with UV treated fabric and five female students were tested. They walked at the speed of 6.7 km/ hr for 15 minutes in an environment, which was controlled at $29^{\circ}C,\;75{\pm}5%$ RH. Before and after exercising, the microclimate under clothing and subjective wear comfort was measured. The results of subjective evaluation of fabric hand were that untreated and treated for 30 minutes PET were recognized as similar and have a good evaluation on comfort, preference, and touch. According to the result of wear comfort, clothing treated by UV for 90 minutes had the lowest value on the thermal and humidity sensations. In addition, the value of tactile and comfort sensation was the highest on the clothing treated by UV for 90 minutes. In the case of objective evaluation, PET treated for 90 minutes was the lowest on microclimate humidity. PET irradiated by UV for 90 minutes was more 'cool' in thermal sensation and more 'dry' in wet sensation. Accordingly, it was consistent with the result of subjective wear comfort.

Wear Performance of Pesticide Protective Clothing in Vinyl Plastic Hothouse made with Water-Oil Repellent and Dual Functional Finished Nonwoven Fabrics (비닐하우스 내에서의 발수발유가공 부직포와 복합가공 부직포로 만든 농약 방호복의 착용성능)

  • Choi, Jong-Myoung;Cho, Jeong-Sook;Cho, Gil-Soo
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.20 no.2
    • /
    • pp.350-361
    • /
    • 1996
  • The objectives of this study mere 1) to investigate whether the different nonwoven fabric types influenced on the objective and subjective wear performances of the experimental pesticide protective pants, 2) to detect whether the different finishes treated to the nonwoven fabrics influenced on the objective and subjective wear performances of the experimental pants, and 3) to detect the relationships between objective wear performances and subjective wear sensation. Three types of nonwoven fabrics (T (Tyvek$\textregistered$), 5 (Sontara$\textregistered$) and K (Kimlon$\textregistered$)) were used as test specimens. By pad-dry.cure method, each of the specimen was treated with fluorocarbon compound for water-oil repellent finish (Tw, Sw, Kw). And each of specimen was treated with organic silicon quarternary ammonium salts and then treated with fluorocabon compound for dual functional finish (76, 50, Kd). Using the three water-oil repellent finished fabrics and the three dual functional finished fabrics, six experimental protective pants (Cl (Tw), C2 (Sw), C3 (Kw), C4 (76), C5 (56), C6 (Kd)) were made according to the same pattern suggested by the Rual Guidance Office. The wear trials of experimental pesticide protective pants were performed in a conditioned vinyl plastic hothouse ($30\pm1^{\circ}C$, $70\pm5%$R.H., 0.25m/sec air velocity). The measurements of skin temperature, microclimate temperature and humidity on the subjects were obtained by the themohygromenter. The subjective wear sensations were measured using previously developed thermal, humidity and overall comfort scales. The results obtained from this study were as follows: 1) There were siginificant differences among nonwoven fabric types on the objective and subjective wear performances, therefore, the skin temperature, microclimate temperature and humidity of subjects who wore the experimental pants made with Sontara were siginificantly lower than those who wore the others. And, the experimental pants made with Sontara were assessed as more comfortable than the others in terms of the subjective thermal, humidity and overall wear sensations. 2) There were no significant differences between two finish types on the objective and subjective wear Performances. 3) The microclimate humidity on the thigh was highly correlated with the overall subjective comfort sensations and the next highly correlated one was the mean skin temperature. That is, the higher the microclimate humidity and the mean skin temperature, the higher the overall subjective comfort sensation ratings which mean the overall subjective sensation was very uncomfortable.

  • PDF

Thermophisiological Responses and Wearing Comfort of the Lining Fabrics of Summer One Piece Dress (여름철 원피스드레스 안감소재에 따른 온열적 생리반응과 주관적 착용감)

  • Kweon, Soo-Ae;Choi, Jong-Myoung;Kim, In-Wha
    • Korean Journal of Human Ecology
    • /
    • v.14 no.4
    • /
    • pp.645-651
    • /
    • 2005
  • The purpose of the study was to investigate the thermophisiological responses and subjective wearing comfort for the six lining fabrics of one-piece dress in summer environment. There were significant differences in the microclimate, the mean skin temperature and the subjective wear comfort for the lining fabrics. The mean skin temperature of rayon and acetate were lower than that of synthetic fiber. The wearing comfort of rayon and acetate were better than that of synthetic fiber. There were clear correlations between the mechanical properties and the subjective wear comfort of lining fabrics. The hygroscopicity and density of textile affected the humidity and tactile sensation of dress, and they were important factors determining the wearing comfort of one-piece dress.

  • PDF

Comfort Evaluation by Wearing a Gait-Assistive Rehabilitation Robot (보행보조 재활 로봇 착용에 따른 쾌적성 평가)

  • Eom, Ran-i;Lee, Yejin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.44 no.6
    • /
    • pp.1107-1119
    • /
    • 2020
  • This study analyzed a subject's body reaction and subjective sensation when wearing a gait-assistive rehabilitation robot. The research method measured skin and clothing surface temperatures for 'seating-standing' and 'walking in place' exercises after wearing a gait-assistive rehabilitation robot. In addition, subjective sensation and satisfaction were evaluated on a 7-point Likert scale. The study results showed that the average skin temperature during exercise while wearing the gait-assistive rehabilitation robot was within a comfortable range. However, during the 'seating-standing' exercise, the skin temperature was slightly lowered. Additionally, the clothing surface temperature tended to be lower than the pre-exercise temperature after all exercises. The subjective sensation evaluation results showed that the wear comfort of the waist part was low during mobility/activity. In addition, an overall improvement in the wear comfort of the robot is necessary. The short-time movement of wearing and walking in the gait-assistive rehabilitation robot did not interfere with the thermal comfort of the body. However, the robot needs to be ergonomically improved in consideration of the long wearing time along with improved material that to satisfy overall wearing comfort.

Evaluation of Physiological Responses and Subjective Sensation in Different Sock Materials (양말 소재별 인체생리적 반응 및 주관적 감각평가)

  • 김칠순;정명희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.8
    • /
    • pp.1475-1483
    • /
    • 2001
  • The purpose of this study was to determine the physiological responses and subjective sensation according to fiber content of socks. Six female students participated in the wear trial test which was conducted in controled environmental chamber with 26${\pm}$1$^{\circ}C$ and 60${\times}$3%. R.H.SAS program was used for statistical analysis. The results of this study were as follows. Mean skin temperature was significantly different among three different socks. AWNP socks had the highest mean skin temperature and instep temperature. Also relative humidity in the microclimate of socks as well as heart rate were influenced by fiber content of socks, However, test of subjective sensation such as thermal, humid, comfort sensation showed that there was no significant difference among three different socks thermal sensation during the exercise and recovery period.

  • PDF

Effect of fabric Sound from Active Wear on Electrodiagnosis and Subjective Sensation and Sensibility (스포츠웨어용 직물의 소리특성이 근전도와 주관적 감각 . 감성에 미치는 영향)

  • 정혜진;김춘정;조길수
    • Science of Emotion and Sensibility
    • /
    • v.6 no.1
    • /
    • pp.27-32
    • /
    • 2003
  • The objectives of this study the effects of fabric noise from active wear on electrodiagnosis(EMG), to examine the effects on subjective sensation, and to relate the EMG results and the subjective sensation.. Five nylon water repellent taffeta fabrics were rubbed each other and the fabric noise were recorded. EMG was done from 10 female university students and electrodes were attached on each participant's upper arm and lower am. The subjective sensation was measured by FMME(Free Modulus Magnitude Estimation). The EMG values from upper arm showed higher voltage than those from lower arm, and the differences between values with fabric sound and without were larger at upper arm than those at lower am. EMG decreased when fabric sound was evaluated soft and pleasant, however It increased in proportion as fabric sound was evaluated loud and sharp. The predicted models for subjective sensation using physical sound properties and EMG results were well explained except roughness. Pleasantness was well predicted by EMG at upper am and EMG at lower arm, as the result, it was explained that the lower the EMG, the more pleasant the participant.

  • PDF

A Study on Wearing Sensation in Accordance with difference in Materials of Aerobic Wear (에어로빅복의 소재 차이에 따른 착용감에 관한 연구)

  • 이미경;류숙희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.1
    • /
    • pp.116-126
    • /
    • 1998
  • This study was conducted to examine the effect of difference in materials of aerobic wear on both human body's physiological reactions and subjective wearing sensation by comparing and analysing not only cotton sparidex A, B and C but nylon spandex D, E and F used as actually wearing materials. The rectal temperature of type A and I remained at high degree, the type C was higher from after high-speed running but dropped sharply when taking a break finally. Both skin temperature and mean skin temperature dropped sharply due to sweat occurred during physical exercise, and then rose slowly when taking a break. Type A -D and B-I showed that the mean skin temperature remained at high degree when wearing a cotton spandex. Type C's temperature within its aerobic wear was lower than type F while its relative humidity was higher than type F. Wearing sensation showed a change similar to wearing, particularly, which was remarkable in type B-E. Also, it was shown that humidity sensation, tactile sensation and comfort sensation were good when wearing the cotton spandex.

  • PDF

A Study on the Comfort Properties of Aerobic Wear with Different Materials (시판 에어로빅복의 재료 특성에 따른 쾌적성능에 관한 연구)

  • Ryoo Sook Hee;Lee Soon Won
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.15 no.1
    • /
    • pp.61-69
    • /
    • 1991
  • In order to investigate the comfort properties of aerobic wear with different materials, the physiological responses, subjective wear sensation and microclimate were measured. The experimental garment were all-in·one type with half·length sleeves made of cotton/ polyurethane and nylon/ polyhrethane fabrics. The conditions of the experimental room were controlled to maintain two type of environ- ments, i.e. $25{\pm}1^{\circ}C$, $60{\pm}5\%$ R. H. and $30{\pm}1^{\circ}C$, $70{\pm}5\%$ R.H., Air velocity was maintained at 0.25 misec all the time. The results are as follows; 1) At $25^{\circ}C$, mean skin temperature and comfort sensation were not significantly different among 2 types of materials. 2) At $30^{\circ}C$, aerobic wear made of cotton/polyurethane fibers showed better pleasant tactile sensation than that of nylon/polyurethane fibers. 3) Under both environmental conditions, microclimate of two types of aerobic wear was not significantly different. 4) Among several aspects of wear sensations, tactile sensation was the most powerful factor to differenciate material differences of aerobic wear.

  • PDF

Physiological Responses and Subjective Sensations by Age through Seasonal Condition (환경온도에 따른 착의 생리반응과 주관적 감각의 연령별 비교)

  • Lee, Jung-Sug;Song, Min-Kyu;Kim, Hee-Eun
    • Fashion & Textile Research Journal
    • /
    • v.11 no.5
    • /
    • pp.833-839
    • /
    • 2009
  • This study was to investigate the human's physiological responses and subjective sensations with wear trial through seasonal condition by age. Climate chamber was set $5^{\circ}C$, RH 45% for winter and $30^{\circ}C$, RH 65% for summer condition. Thirty male subjects were volunteered consisted of 10 people in their 20s, 40s, and 60s. In this study physiological responses such as rectal temperature, skin temperature, clothing microclimate, heart rate and blood pressure were measured. As for age, 60s was the highest in rectal temperature regardless of seasonal condition. In skin temperature, 40s was the highest in winter and 20s was the highest in summer. In clothing microclimate temperature and heart rate, 20s was the highest regardless of seasonal condition. And blood pressure was appeared the highest in 20s regardless of seasonal condition. Subjective sensations such as temperature sensation, wetness sensation and thermal comfort were measured. The subjects revealed that temperature sensation was higher 20s than 60s. Compare of other age group, 60s felt colder in the same environment and clothing. It suggested that temperature susceptibility in 60s became weakened showing no change sensation during the cold exposure. Wetness sensation was higher 20s than 60s. Thermal comfort of 60s was felt more discomfortable than any other age group. This means require the supplement of a suitable clothing in order to adjust to change of environmental conditions.

Physical Properties of Sports Material and Wear Trial Test of Sports Socks During Exercise (스포츠양말 소재의 물성 및 운동시 양말의 착용감 분석)

  • 김칠순;이훈자;박명자
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.8
    • /
    • pp.1115-1124
    • /
    • 2000
  • The purpose of this study was 1) to determine physical properties, and subjective evaluation of sensation of sports socks with various type of fiber content and fabric structure, and 2) to develop regression equations for predicting each sensation from physical properties of socks. Thirty healthy male students participated in the wear test with ten replications. The ANOVA, Duncans multiple test, and multiple regression, and paired-t test were used in the statistical analysis, using an SAS package. The results of this study are as follows: 1. 100% cotton socks had higher absorbency and wickability among five different socks. Comfort sensation, tactile sensation and fit sensation of socks were significantly influenced by types of fiber content. People felt that polypropylene socks were less comfortable & slightly tighter, and cotton socks were drier than the other socks. Terry socks were warmer than single jersey socks. 2. The results of the regression analysis showed that tactile sensation of socks after exercise can be predicted from the cube of moisture permeability($R^2$=0.99), and fit sensation can be predicted from drop absorbency, moisture permeability, wickability in wale and weight($R^2$=-0.98).

  • PDF