• Title/Summary/Keyword: stud connection

검색결과 90건 처리시간 0.028초

Experiments on Shear Connections of PSC Girders with Prefabricated Slabs

  • 심창수;정철헌;현병학;김영진
    • 콘크리트학회논문집
    • /
    • 제16권4호
    • /
    • pp.573-579
    • /
    • 2004
  • For the fast construction and replacement of bridges in urban area, a prefabricated bridge system can be an excellent alternative. Details of prefabricated slabs for PSC girders were developed and static tests on shear connections were conducted to propose design equations of the shear connection. Stirrups and stud connectors were used as shear connectors and non-shrink mortar was used for the filling material in shear pockets for shear connectors. Stirrups and studs were fabricated to insert embedded nut-type devices in PSC girders. Shear strength of the shear connection considering chemical bond, friction and mechanical connectors was evaluated and empirical equations were suggested. Due to the mechanical connectors, ultimate slip capacity of the shear connection was sufficient for shear load redistribution, and suggested details of the shear connection showed good performance in terms of strength and ductility.

Experimental investigation on flexural behaviour of HSS stud connected steel-concrete composite girders

  • Prakash, Amar;Anandavalli, N.;Madheswaran, C.K.;Lakshmanan, N.
    • Steel and Composite Structures
    • /
    • 제13권3호
    • /
    • pp.239-258
    • /
    • 2012
  • In this paper, experimental investigations on high strength steel (HSS) stud connected steel-concrete composite (SCC) girders to understand the effect of shear connector density on their flexural behaviour is presented. SCC girder specimens were designed for three different shear capacities (100%, 85%, and 70%), by varying the number of stud connectors in the shear span. Three SCC girder specimens were tested under monotonic/quasi-static loading, while three similar girder specimens were subjected to non-reversal cyclic loading under simply supported end conditions. Details of casting the specimens, experimental set-up, and method of testing, instrumentation for the measurement of deflection, interface-slip and strain are discussed. It is found that SCC girder specimen designed for full shear capacity exhibits interface slip for loads beyond 25% of the ultimate load capacity. Specimens with lesser degree of shear connection show lower values of load at initiation of slip. Very good ductility is exhibited by all the HSS stud connected SCC girder specimens. It is observed that the ultimate moment of resistance as well as ductility gets reduced for HSS stud connected SCC girder with reduction in stud shear connector density. Efficiency factor indicating the effectiveness of high strength stud connectors in resisting interface forces is estimated to be 0.8 from the analysis. Failure mode is primarily flexure with fracturing of stud connectors and characterised by flexural cracking and crushing of concrete at top in the pure bending region. Local buckling in the top flange of steel beam was also observed at the loads near to failure, which is influenced by spacing of studs and top flange thickness of rolled steel section. One of the recommendations is that the ultimate load capacity can be limited to 1.5 times the plastic moment capacity of the section such that the post peak load reduction is kept within limits. Load-deflection behaviour for monotonic tests compared well with the envelope of load-deflection curves for cyclic tests. It is concluded from the experimental investigations that use of HSS studs will reduce their numbers for given loading, which is advantageous in case of long spans. Buckling of top flange of rolled section is observed at failure stage. Provision of lips in the top flange is suggested to avoid this buckling. This is possible in case of longer spans, where normally built-up sections are used.

프리캐스트 바닥판 합성형 교량에서의 베딩층의 두께를 고려한 전단연결재의 피로강도 (Fatigue strength of stud shear connector considering bedding layer thickness in precast deck composite bridges)

  • 류형근;심창수;정철헌;장승필
    • 한국강구조학회 논문집
    • /
    • 제14권1호
    • /
    • pp.113-120
    • /
    • 2002
  • 프리캐스트 바닥판 합성형 교량의 전단연결부는 전단포켓과 베딩층이 존재하여 현장타설 강합성 교량과는 다른 구조적 특징을 갖고 있다. 따라서 프리캐스트 바닥판의 전단연결재 설계의 기초를 수립하기 위해서는 실험을 통한 연구가 수행되어야 한다. 프리캐스트 바닥판 합성형 교량의 전단연결재의 피로수명을 평가하기 위하여 베딩층의 두께를 변수로 한 전단연결재의 push-out 피로 시험을 수행하였다. push-out 피로 시험의 수행 결과, 전단연결재의 파괴모드를 확인하였고, 이를 통해 프리캐스트 바닥판 합성형 교량의 전단연결재의 피로수명 곡선식을 유도하였다.

냉간성형강 벽체패널의 연결부실험 (Connection Tests for Cold-Formed Steel Wall Panels)

  • 이영기
    • 대한토목학회논문집
    • /
    • 제34권3호
    • /
    • pp.739-746
    • /
    • 2014
  • 본 연구의 대상은 석고보드와 냉간성형강 스터드로 구성된 벽체용 합성패널이다. 양면의 석고보드 사이에 위치한 스터드는 나사로 연결되어 있고, 이와 같은 연결부의 부분합성거동을 정량화하여 나사접합부의 단위미끄럼을 유발하는 단위길이 당 전단하중($S_{slip}$)을 산정하는 것이 목적이었다. 실험방법은 1962 AISI규준을 기초로 하여 실시하였다. 본 연구에서 산정한 $S_{slip}$값을 이용한 이론적 추정치와 기 발표된 공칭축강도의 실험값과의 비교에서 만족할 만한 결과를 도출하였다. 그러므로 본 연구의 결과는 연구범위와 유사한 냉간성형강 부재의 해석과 설계에 있어 구조 기술자에게 가치가 있는 정보를 제공할 것이다.

Parameters influencing redundancy of twin steel box-girder bridges

  • Kim, Janghwan;Kee, Seong-Hoon;Youn, Heejung;Kim, Dae Young
    • Steel and Composite Structures
    • /
    • 제29권4호
    • /
    • pp.437-450
    • /
    • 2018
  • A bridge comprising of two girders, such as a twin steel box-girder bridge, is classified as fracture critical (i.e., non-redundant). In this study, the various bridge components of the twin steel box-girder bridge are investigated to determine if these could be utilized to improve bridge redundancy. Detailed finite-element (FE) models, capable of simulating prominent failure modes observed in a full-scale bridge fracture test, are utilized to evaluate the contributions of the bridge components on the ultimate behavior and redundancy of the bridge sustaining a fracture on one of its girders. The FE models incorporate material nonlinearities of the steel and concrete members, and are capable of capturing the effects of the stud connection failure and railing contact. Analysis results show that the increased tensile strength of the stud connection and (or) concrete strength are effective in improving bridge redundancy. By modulating these factors, redundancy could be significantly enhanced to the extent that the bridge may be excluded from its fracture critical designation.

Mechanical behavior of prefabricated steel-concrete composite beams considering the clustering degree of studs

  • Gao, Yanmei;Fan, Liang;Yang, Weipeng;Shi, Lu;Zhou, Dan;Wang, Ming
    • Steel and Composite Structures
    • /
    • 제45권3호
    • /
    • pp.425-436
    • /
    • 2022
  • The mechanical behaviors of the prefabricated steel-concrete composite beams are usually affected by the strength and the number of shear studs. Furthermore, the discrete degree of the arrangement for shear stud clusters, being defined as the clustering degree of shear stud λ in this paper, is an important factor for the mechanical properties of composite beams, even if the shear connection degree is unchanged. This paper uses an experimental and calculation method to investigate the influence of λ on the mechanical behavior of the composite beam. Five specimens (with different λ but having the same shear connection degree) of prefabricated composite beams are designed to study the ultimate supporting capacity, deformation, slip and shearing stiffness of composite beams. Experimental results are compared with the conventional slip calculation method (based on the influence of λ) of prefabricated composite beams. The results showed that the stiffness in the elastoplastic stage is reduced when λ is greater than 0.333, while the supporting capacity of beams has little affected by the change in λ. The slip distribution along the beam length tends to be zig-zagged due to the clustering of studs, and the slip difference increases with the increase of λ.

전단연결재의 내화성능에 대한 유한요소해석 (Finite element analysis of shear connection in composite beams exposed to fire)

  • 임옥근;최승관
    • 공학기술논문지
    • /
    • 제11권4호
    • /
    • pp.279-285
    • /
    • 2018
  • A shear connection between the steel beam and concrete slab determines the stability of composite beams. An extensive numerical study to evaluate the resistance of the shear connection in a solid slab at high temperature was conducted. Three-dimensional thermo-mechanical finite element models were developed using a dynamic explicit method and concrete damaged plasticity model. Temperature-dependent plasticity parameters of the concrete model were proposed, and the accuracy of the developed model was obtained against experimental data. This investigation has revealed that a stud shearing failure occurs regardless of temperatures, and its shearing location changes in accordance with a rise in temperature. A new strength reduction formula has been presented to estimate the resistance of the shear connection at high temperatures.

복합스터드의 압축 좌굴 거동 (Behavior of Hybrid Stud under Compressive Load)

  • 이상섭;배규웅
    • 한국강구조학회 논문집
    • /
    • 제16권5호통권72호
    • /
    • pp.609-619
    • /
    • 2004
  • 유럽을 중심으로 스틸스터드의 약점으로 지목 받고 있는 열교현상을 억제하기 위한 스터드 개선 연구가 활발히 진행되고 있다. 이 연구는 크게 마감재와 접촉 면적을 줄이는 방법, 웨브면에서 열전달 경로를 늘이는 방법, 열전도성이 낮은 소재를 사용하는 방법, 그리고 스터드를 피복하는 방법으로 구분할 수 있다. 비교적 저층의 주거용 건축물을 대상으로 하는 국외의 경우 에너지 소비에 초점이 맞춰져 있지만, 본 연구의 경우 중층화를 대비하여 구조적 성능도 고려하여 아연도금강판(SGC58)과 FRP를 에폭시로 부착하여 150SL 형태의 복합스터드를 개발하였다. 복합스터드의 소재로는 두께 1.0mm과 1.2mm 강판과 두께 4mm(4ply), 6mm(6ply)의 FRP를 적용하였고, 4가지의 접합 상세에 대한 제작 및 실험을 통해 최종적으로 우수한 결과를 보인 2가지를 선택하였다. 이와 같은 과정을 거쳐 개발된 복합스터드의 압축 성능을 확인하기 위해 2가지 접합 상세에 대해 단면 높이인 150mm에 대해 3, 6, 9, 12배 길이에 대해 압축 실험을 계획하였고, 기존 스틸 스터드와 비교하기 위하여 동일 형태의 비교 실험체도 제작하였다. 실험결과, 복합스터드의 최대하중은 강판 두께 1.0mm인 경우 동일 두께의 스틸 스터드보다 평균 1.62배, 1.2mm인 경우 평균 1.46배 증가하였으며, 가력 종료 시점에 이르기까지 일체 거동을 보여 구조적으로 우수함이 입증되었다.

초고성능 콘크리트 바닥판 교량의 전단연결부에 대한 실험적 연구 (An Experimental Study on the shear connection for UHPC Deck Bridge)

  • 유동민;황훈희;김성태;박성용
    • Composites Research
    • /
    • 제24권5호
    • /
    • pp.29-33
    • /
    • 2011
  • 교량 바닥판에서 고성능 재료의 적용은 고가임에도 불구하고 바닥판 중량 감소와 경제성 향상을 위한 대안으로 대표될 수 있다. 초고성능콘크리트 재료를 활용한 교량에서 기존의 헤드형 스터드가 바닥판과 강재 거더사이의 전단력을 충분히 전달할 수 있는지 그 적용성을 검증할 필요가 있다. 이 논문에서는 UHPC 교량 바닥판과 강재 거더의 합성거동을 분석하기 위해 2면 전단실험을 수행하였다. 정적 재하 실험 결과 헤드형 스터드의 실험체별 극한강도는 직경에 비례였으며, 일반 콘크리트, 교량 바닥판에 비해 전단강도가 향상되는 것으로 나타났다.

탄성채널을 이용한 석고보드 건식벽체의 저주파 대역 차음성능 개선 (Improvement of Sound Insulation at Low Frequencies Using Resilient Channel)

  • 김경호;전진용
    • 한국소음진동공학회논문집
    • /
    • 제27권1호
    • /
    • pp.94-99
    • /
    • 2017
  • Breaking the rigid connection between the two faces of the wall can significantly improve the sound transmission loss of the wall. This is usually achieved by resiliently mounting the gypsum board on one of the two faces of the wall using resilient channel. Resilient channel with less stiffness than that of air cavity could move the resonance frequency of the light-weight wall. So we can get higher sound transmission loss at low frequencies for light-weight wall using resilient channel. It's sound transmission loss is 17 dB higher than that of single stud wall, and 5 dB higher than that of double stud wall.