• Title/Summary/Keyword: structures in hand

Search Result 850, Processing Time 0.028 seconds

A preliminary numerical analysis study on the seismic stability of a building and underground structure by using SSI (SSI를 이용한 건물과 인접지하구조물의 내진 안정성에 대한 기초 수치해석 연구)

  • You, Kwang-Ho;Kim, Young-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.1
    • /
    • pp.23-38
    • /
    • 2018
  • Up to now, most of studies on seismic analysis have been limited to analyze buildings and underground structures individually so that the interaction between them could not be analyzed effectively. Thus, in this study, a dynamic analysis was conducted for soil-structure interaction with a complex underground facility composed of a building and an adjacent underground structure constructed on a surface soil and the bed rock ground conditions. Seismic stability was analyzed based on interstory drift ratio and bending stress of structure members. As a result, an underground structure has more effect on a high-rise building than a low-rise building. However the above structures were proved to be favorable for seismic stability. On the other hand, tensile bending stresses exceeded the allowable value at the underground part of the building and the adjacent underground structure so that it turned out that the underground part could be weaker than the above part. Therefore, it is inferred that above and underground structures should be analyzed simultaneously for better prediction of their interaction behavior during seismic analyses because there exist various structures around buildings in big cities.

Mode-I fracture toughness of carbon fiber/epoxy composites interleaved by aramid nonwoven veils

  • Beylergil, Bertan;Tanoglu, Metin;Aktas, Engin
    • Steel and Composite Structures
    • /
    • v.31 no.2
    • /
    • pp.113-123
    • /
    • 2019
  • In this study, carbon fiber/epoxy (CF/EP) composites were interleaved with aramid nonwoven veils with an areal weight density of $8.5g/m^2$ to improve their Mode-I fracture toughness. The control and aramid interleaved CF/EP composite laminates were manufactured by VARTM in a [0]4 configuration. Tensile, three-point bending, compression, interlaminar shear, Charpy impact and Mode-I (DCB) fracture toughness values were determined to evaluate the effects of aramid nonwoven fabrics on the mechanical performance of the CF/EP composites. Thermomechanical behavior of the specimens was investigated by Dynamic Mechanical Analysis (DMA). The results showed that the propagation Mode-I fracture toughness values of CF/EP composites can be significantly improved (by about 72%) using aramid nonwoven fabrics. It was found that the main extrinsic toughening mechanism is aramid microfiber bridging acting behind the crack-tip. The incorporation of these nonwovens also increased interlaminar shear and Charpy impact strength by 10 and 16.5%, respectively. Moreover, it was revealed that the damping ability of the composites increased with the incorporation of aramid nonwoven fabrics in the interlaminar region of composites. On the other hand, they caused a reduction in in-plane mechanical properties due to the reduced carbon fiber volume fraction, increased thickness and void formation in the composites.

Corrosion Behavior of Galvanized Steels with Outdoor Exposure Test in Korea for 36 Months (36개월간 국내 옥외폭로시험에 따른 아연도강의 부식거동)

  • Kim, K.T.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.231-241
    • /
    • 2018
  • Atmospheric corrosion is generally an electrochemical degradation process of metal. It can be caused by various corrosion factors of atmospheric component, weather, and air pollutants. Moisture, particles of sea salts, and sulfur dioxide are major factors in atmospheric corrosion. Galvanizing coating is one of the most efficient ways to protect iron from corrosion by zinc plating on the surface of the iron. Galvanized steels are being widely used in automobiles, building structures, roofing, and other industrial structures due to their high corrosion resistance compared to bare iron. Atmospheric corrosion of galvanized steel has shown complex corrosion behavior depending on coating process, coating thickness, atmospheric environment, and air pollutants. In addition, different types and kinds of corrosion products can be produced depending on the environment. Lifespan of galvanized steels is also affected by the environment. Therefore, the objective of this study was to determine the corrosion behavior of galvanized steel under atmospheric corrosion at six locations in Korea. When the exposure time was increased, content of zinc from GA surface decreased while contents of iron and oxygen tended to increase. On the other hand, content of iron was constant even after 36 months of exposure of GI.

Testing Gravitational Weak-lensing Maps with Galaxy Redshift Surveys: preliminary results

  • Ko, Jongwan;Utsumi, Yousuke;Hwang, Ho Seong;Dell'Antonio, Ian P.;Geller, Margaret J.;Yang, Soung-Chul;Kyeong, Jaemann
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.45.2-45.2
    • /
    • 2014
  • To measure the mass distribution of galaxy systems weak-lensing analysis has been widely used because it directly measures the total mass of a system regardless of its baryon content and dynamical state. However, the weak-lensing only provides a map of projected surface mass density. On the other hand, galaxy redshift surveys provide a map of the three-dimensional galaxy distribution. It thus can resolve the structures along the line of sight projected in the weak-lensing map. Therefore, the comparison of structures identified in the weak-lensing maps and in the redshift surveys is an important test of the issues limiting applications of weak-lensing to the identification of galaxy clusters. Geller et al. (2010) and Kurtz et al. (2012) compared massive clusters identified in a dense redshift survey with significant weak-lensing map convergence peaks. Both assessments of the efficiency of weak-lensing map for cluster identification did not draw a general conclusion, because the sample is so small. Thus, we additionally perform deep imaging observations of fields in a dense galaxy redshift survey that contain galaxy clusters at z~0.2-0.5, using CFHT Megacam.

  • PDF

A Study on Quality Control and Measurement for Acquisition of Dynamic Friction Coefficient on Back-hand Skin (손등피부의 운동마찰계수 획득을 위한 컨트롤 요소 및 측정에 관한 연구)

  • Lee, Jae-Hoon;Song, Han-Wook;Park, Yon-Kyu;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.14 no.3
    • /
    • pp.103-111
    • /
    • 2008
  • Recently, skin diagnosis has been suggested as a promising tool for discrimination of Sasang Constitution, reported by examining the skin characteristics such as thickness, stiffness, slip, and skin textures like wrinkles and furrows. However, the works had a limitation in that clinical decision on the skin characteristics was made by relying upon oriental medicine doctors' subjective sense of touch. In order to objectify the skin diagnosis and claim its efficacy on the discrimination of the Sasang Constitutions, it is necessary to demonstrate its discrimination capability by providing numerical values in terms of physical quantities obtained from measurements using today's sensors and equipment technologies, which motivated this work as a priliminary step towards objectification of skin diagnosis. The skin characteristics focused in this work is the slip property of the back-hand skin that has been exploited using the dynamic friction measurement system. First, curved geometric effects of the back-hand skin on the measured lateral/vertical force signals were estimated using the artificially designed silicon coated structures, which led to a suggestion on a quality controlled experimental design based upon a empirical analysis model. Second, the experimental design thus suggested has been applied to the measurement of dynamic friction coefficients for two healthy male subjects of Taeumin (TE) and Soyangin (SY), respectively. The result shows that the dynamic friction coefficient is less for the SY subject than for the TE subject around the area of the skin used for diagnosis by the oriental medicine doctor, implying the TE subject's skin is more slippery than the SE subject's that is consistent with the oriental medicine doctor's diagnosis. Hopefully, this work can provide guidelines for obtaining quality data in friction measurement to be collected for discussion on the efficacy of the skin diagnosis and its objectification through statistical analysis.

  • PDF

Seismic Analysis on Recycled Aggregate Concrete Frame Considering Strain Rate Effect

  • Wang, Changqing;Xiao, Jianzhuang;Sun, Zhenping
    • International Journal of Concrete Structures and Materials
    • /
    • v.10 no.3
    • /
    • pp.307-323
    • /
    • 2016
  • The nonlinear behaviors of recycled aggregate concrete (RAC) frame structure are investigated by numerical simulation method with 3-D finite fiber elements. The dynamic characteristics and the seismic performance of the RAC frame structure are analyzed and validated with the shaking table test results. Specifically, the natural frequency and the typical responses (e.g., storey deformation, capacity curve, etc.) from Model 1 (exclusion of strain rate effect) and Model 2 (inclusion of strain rate effect) are analyzed and compared. It is revealed that Model 2 is more likely to provide a better match between the numerical simulation and the shaking table test as key attributes of seismic behaviors of the frame structure are captured by this model. For the purpose to examine how seismic behaviors of the RAC frame structure vary under different strain rates in a real seismic situation, a numerical simulation is performed by varying the strain rate. The storey displacement response and the base shear for the RAC frame structure under different strain rates are investigated and analyzed. It is implied that the structural behavior of the RAC frame structure is significantly influenced by the strain rate effect. On one hand, the storey displacements vary slightly in the trend of decreasing with the increasing strain rate. On the other hand, the base shear of the RAC frame structure under dynamic loading conditions increases with gradually increasing amplitude of the strain rate.

Fatigue Behavior of Steel Fiber Reinforced Concrete Continuous Beams under Cyclic Loading (반복하중하에서 강섬유보강 철근콘크리트 연속보의 피로거동)

  • Kwak, Kae-Hwan;Park, Jong-Gun;Jang, Hwa-Sup
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.6
    • /
    • pp.47-58
    • /
    • 2004
  • As concrete structures are getting larger, higher, longer and more specialized, it is more required to develop steel fiber concrete and apply to the real world. In this research, it is aimed to have fatigue strength examined, varying the steel fiber content of 0%, 0.75%, 1.00%, 1.25% by experimental study of fatigue behavior of the steel fiber reinforced concrete continuous beams under cyclic loading. The ultimate load and initial load of flexural cracking were measured by static test. In addition, the load versus strain relation, load versus deflection relation, crack pattern and fracture mode by increasing weight were observed. On the other hand, the crack propagation and the modes of fracture according to cycle number and the relation of cyclic loading to deflection relation and strain relation were investigated by fatigue test. As the result of fatigue test, continuous beam without steel fiber was failed at 60 ~ 70% of The static ultimate strength and it could be concluded that fatigue strength to two million cyclic loading was arround 67.2% by S-N curve. On the other hand, that with steel fiber was failed at 65 ~ 85% of the static ultimate strength and it could be concluded fatigue strength to two million cyclic loading around 71.7%.

Correlation Analysis of Ocular Dominance and Levator Palpebrae Superioris Muscle Function (주시안과 눈꺼풀 올림근 기능의 상관관계 분석)

  • Ha, Ki-Young;Suh, Hyeun-Woo;Kim, Boo-Yeong;Kim, Tae-Yeon;Park, Sung-Gyu
    • Archives of Plastic Surgery
    • /
    • v.37 no.3
    • /
    • pp.265-270
    • /
    • 2010
  • Purpose: Most of the bilateral structures in our body are not perfectly balanced, such that one side is preferred than the other or it has physiological superiority. Eyes also have an imbalance; the eye with sensory and motional superiority compared to the other is called dominant eye. Authors of this study focused on analyzing the correlation between the dominant eye and levator palpebrae superioris muscle. Methods: The subject of this study was 42 patients with no ptosis and with no past history of blepharoplasty. Hand dominance was identified through questionnaire and dominant eye was identified by hole-in-the-card dominance test (Dolman's test) in all patients. The function of levator palpebrae superioris muscle was measured by MLD (marginal limbal distance). During the measuring procedure, frontalis muscle was not inhibited to avoid the eyelid skin hooding. Results: Out of 42 patients, 27 patients (64.3%) were right ocular dominant, 15 patients (35.7%) were left ocular dominant, 36 patients (85.7%) were right hand dominant and 4 patients (9.5%) were left hand dominant. Out of 27 right ocular dominant patients, right MLD was larger than the left in 26 patients (96.3%). It was larger in average of 0.47 mm (p<0.001) in 27 right ocular dominant patients. Also, left MLD was larger than the right in 11 patients (73.3%) out of 15 left ocular dominant patients. It was larger in average of 0.57 mm (p=0.003) in 27 left ocular dominant patients. MLD on the side of the dominant eye was larger in average of 0.50 mm (p<0.001) than the MLD of non-dominant eye side. Right MLD was larger than the left in average of 0.28mm (p=0.010) in right hand dominant patients, and left MLD was larger than the right in average of 1.15 mm (p=0.025) in left hand dominant patients. Conclusion: The function of levator palpebrae muscle differs in right and left, and the difference correlates with the dominant eye. Also, the function of levator palpebrae muscle is stronger in the dominant eye. We were able to present statistical evidence regarding the difference of the function in right and left levator palpebrae muscle. This may be a factor worth consideration in terms of balancing the eyes during the blepharoplasty.

Basis Set Superposition Error on Structures and Complexation Energies of Organo-Alkali Metal Iodides

  • Kim, Chang-Kon;Zhang, Hui;Yoon, Sung-Hoon;Won, Jon-Gok;Kim, Chan-Kyung
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.8
    • /
    • pp.2228-2234
    • /
    • 2010
  • Theoretical studies have been performed to study the binding characteristics of the alkali metal iodides, M-I (M = Li, Na, K), to poly(ethylene oxide) (PEO, I), poly(ethylene amine) (PEA, II) and poly(ethylene N-methylamine) (PEMA, III) via the B3LYP method. In this study, two types of complexes, singly-coordinated systems (SCS) and doubly-coordinated systems (DCS), were considered, and dissociation energies (${\Delta}E_D$) were calculated both with and without basis set superposition error (BSSE). Two types of counterpoise (CP) approach were investigated in this work, but the ${\Delta}E_D$ values corrected by using the function CP (fCP) correction exhibited an unusual trend in some cases due to deformation of the sub-units. This problem was solved by including geometry relaxation in the CP-corrected (GCP) interaction energy. On the other hand, the effects of the BSSE on the structures were very small when the complexes were re-optimized on the CP-corrected (RCP) potential energy surface (PES), even if the bond lengths between X and $M^+$ ($d_{{X-M}^+}$) and between $M^+$ and $I^-$ ($d_{M^+-I^-}$) were slightly lengthened. Therefore, neither the GCP nor RCP corrections made much difference to the dissociation energies.

Case Studies of Domestic and Foreign Photovoltaic Integrated Projects (국내.외 PV 통합 프로젝트의 사례분석)

  • Yoon, Sung-Won;Kim, Hye-Seong
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.6
    • /
    • pp.85-94
    • /
    • 2008
  • This paper is concerned with the domestic and foreign PV integrated projects in view of structural design. These projects are classified with public and display 6 facilities. The evaluated items are natural integration with building, engineering details and innovative new design. 6 domestic public and display facilities are frequently using isolated supporting system at roof, but show weakness in design integration. But the cases, using the PV panel in the stage of design some display facilities, are increasing. In the other hand, foreign public and display facilities are using the modul connection majorly and the structural and design integration are obtained.

  • PDF