• Title/Summary/Keyword: structure-sensitivity

검색결과 1,594건 처리시간 0.027초

설계 민감도법을 이용한 유도 전기장 분포 제어를 위한 철심구조 최적화 연구 (Optimization of Iron Core Structure for Controlling Induced Electric Field Distribution Using the Continuum Design Sensitivity Analysis (CDSA))

  • 박준구
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권8호
    • /
    • pp.397-400
    • /
    • 2006
  • An optimized iron core structure of stimulating coil are presented in order to control the induced electric field distribution using the Continuum Design Sensitivity Analysis (CDSA) combined with a commercially available generalized finite element code (OPERA). The results show that a Figure-Of-Eight (FOE) coil as well as a circular coil with the proposed iron core structure can increase induced electric field intensity by more than two times and make better field localization, compared with those of existing stimulation coil with a air core. After considering manufacturing constraints, a practical iron core structure based on the proposed optimized one is proposed and its performance is analyzed.

A PDMS-Coated Optical Fiber Bragg Grating Sensor for Enhancing Temperature Sensitivity

  • Park, Chang-Sub;Joo, Kyung-Il;Kang, Shin-Won;Kim, Hak-Rin
    • Journal of the Optical Society of Korea
    • /
    • 제15권4호
    • /
    • pp.329-334
    • /
    • 2011
  • We proposed a poly-dimethylsiloxane (PDMS)-coated fiber Bragg grating (FBG) temperature sensor for enhancing temperature sensitivity. By embedding the bare FBG in a temperature-sensitive elastomeric polymer, the temperature sensitivity of the proposed structure could be effectively improved by 4.2 times higher than those of the conventional bare-type FBG sensors due to the high thermal expansion coefficient of the PDMS. We analyzed the temperature-sensitivity enhancement effect with the increased Bragg wavelength shift in our structure and dependence on the temperature sensitivity with respect to the cross-section area of the PDMS.

Improved Sensitivity of a Glucose Sensor by Encapsulation of Free GOx in Conducting Polymer Micropillar Structure

  • Jung, Shin-Hwan;Lee, Young-Kwan;Son, Yong-Keun
    • Journal of Electrochemical Science and Technology
    • /
    • 제2권2호
    • /
    • pp.124-129
    • /
    • 2011
  • A simple process of fabricating micropillar structure and its influence upon enhancing electrochemical biosensor response were studied in this work. Conducting polymer PEDOT was used as a base material in formulating a composite with PVA. Micro porous PC membrane filter was used as a template for the micropillar of the composite on ITO electrode. This structure could provide plenty of encapsulating space for enzyme species. After dosing enzyme solution into this space, Nafion film tent was cast over the pillar structure to complete the micropillar cavity structure. In this way, the encapsulation of enzyme could be accomplished without any chemical modification. The amount of enzyme species was easily controllable by varying the concentration of the dosing solution. The more amount of enzyme is stored in the sensor, the higher the electrochemical response is produced. One more reason for the sensitivity improvement comes from the large surface area of the micropillar structure. Application of 0.7 V produced the best current response under the condition of pH 7.4. This biosensor showed linear response to the glucose in 0.1~1 mM range with the average sensitivity of $14.06{\mu}A/mMcm^2$. Detection limit was 0.01 mM based on S/N = 3.

저진동 차체의 필라 설계 및 최전화 기법 (Technology for Initial Design and Analysis of Vehicle Pillar Structures for Vibration)

  • 임홍재;이상범
    • 소음진동
    • /
    • 제5권3호
    • /
    • pp.395-402
    • /
    • 1995
  • In general low frequency vibration characteristics like an idleshake is mainly influeced by pillar section properties and joints. So the design technique development of vehicle pillar structures is required to initial design and vehicle development stage. In this paper to develop pillar structure design technique considering low frequency vibration characteristics, strain energy method, design sensitivity analysis method, and design optimization method using commercial finite element analysis program and optimization program are presented.

  • PDF

거대 구조물의 국부진동계의 등가계 산출과 이를 이용한 최적구조변경법 (A Study on the estimation of an equivalent system of a local vibration system of a huge structure and the Optimum Structural Modification Method)

  • 박석주;황문주;오창근;김성우
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 1998년도 춘계학술발표회 논문집
    • /
    • pp.120-127
    • /
    • 1998
  • It is very difficult to execute the vibration analysis of a huge strucutre, which takes up much time and expense. In this paper we intend to make the equivalent system of a local vibration system of a huge structure with a view to improving the dynamic characteristics and reducing time and expense. First of all, upper deck structure model is maded. And we perform the vibration analysis by the Substructure Synthesis Method and execute the exciting test for the upper deck structure model, and observe the coincidences of two results to confirm the reliability of the analyzing tools used. To make the equivalent system, we give boundary condition to sub-structure that want to be modified and execute the Sensitivity Analysis Method and the Optimum Structural Modification Method. And we execute the structural modification of the equivalent system.. The following can be found from this study. 1. The analytical results are generally coincident with each other. 2. The equivalent system of the superstructure model can be easily obtained using the sensitivity analysis metho and the optimum structural modification method. 3. The structural modification using the equivalent system can be obtained good results above 90% of object value.

  • PDF

위상최적설계를 위한 입자-구조 충돌 모델 (Particle-Structure Collision Modeling for Topology Optimization)

  • 최영훈;윤길호
    • 한국전산구조공학회논문집
    • /
    • 제36권6호
    • /
    • pp.365-370
    • /
    • 2023
  • 본 논문에서는 위상최적설계를 위한 입자-구조 충돌 모델을 제시한다. 위상최적설계를 위해서는 민감도 분석이 선행되어야 하며, 민감도 분석이 가능한 새로운 모델이 필요하다. 본 논문에서는 위상최적설계를 위한 민감도 분석을 수행하기 위한 입자-구조 충돌 모델을 제시한다. 이후 이 모델을 이용하여 위상최적설계를 위한 민감도 분석을 수행한다. 제안한 모델의 정확도를 평가하기 위해 먼저 단순화된 1차원 충돌 문제에 적용한다. 이후, 이 모델을 이용하여 위상 최적화를 통해 입자의 최종 위치를 최적화하여 위상 최적화에 대한 이 모델의 적용 가능성을 확인한다. 이러한 결과는 위상 최적화에서 입자-구조 충돌을 고려하는 것이 가능하다는 것을 보여준다.

직접접합기술을 이용한 고온용 Si 홀 센서의 제작 (Fabrication of High-Temperature Si Hall Sensors Using Direct Bonding Technology)

  • 정귀상;김용진;신훈규;권영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1431-1433
    • /
    • 1995
  • This paper describes the characteristics of Si Hall sensors fabricated on a SOI(Si-on-insulator} structure, in which the SOI structure was forrmed by SDB(Si-wafer direct bonding) technology. The Hall voltage and the sensitivity of implemented Si Hall devices show good linearity with respect to the applied magnetic flux density and supplied current. The product sensitivity of the SDB SOI Hall device is average $600V/A{\cdot}T$. In the temperature range of 25 to $300^{\circ}C$, the shifts of TCO(Temperature Coefficient of the Offset Voltage) and TCS(Temperature Coefficient of the product Sensitivity) are less than ${\pm}6.7{\times}10^{-3}/^{\circ}C$ and ${\pm}8.2{\times}10^{-4}/^{\circ}C$, respectively. From these results, Si Hall sensors using the SOI structure presented here are very suitable for high-temperature operation.

  • PDF

자켓형 해양 구조물의 동적거동에 대한 민감도 연구 (A Study on the Sensitivity of Dynamic Behavior of Jacket Type Offshore Structure)

  • 이정탁;이강수;신상학;손충렬
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.110-118
    • /
    • 2008
  • This thesis introduces a study conducted by ANSYS, Finite Element Analysis program, on dynamic behavior by thickness of a chord and a brace of a jacket typed marine structure. As load condition to work on offshore structures is getting much more various, it becomes more important to design the structures and operate them. In addition, stability is also required. As the result of this study, it was proved that wind and wave load gives more affection on frequency than on added mass in the Modal Analysis. Also, the chord and brace affect stiffness more than diagonal brace according to sensitivity analysis.

  • PDF

임의의 형태를 갖는 흠을 이용한 표면형상변형을 통한 동특성 변경 (Structural Dynamics Modification Using Surface Grooving Technique)

  • 박미유;박영진;박윤식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.859-863
    • /
    • 2004
  • Structural Dynamics Modification is very effective technique to improve structure's dynamic characteristics by adding or removing auxiliary structures, changing material property, changing shape of structure. In this research, using the surface grooving technique, shape of base structure was changed to improve its first natural frequency. Utilizing the result of sensitivity analysis, groove shape was formed gathering the many small embossing elements. For this process, Sensitivity Criterion Factor was introduced. To reduce its amount of calculation, the range of target area was restricted to their neighboring area and that result was very successful.

  • PDF

실리콘기판 직접접합기술을 이용한 SOI 홀 센서의 제작과 그 특성 (Fabrication of a SOI hall sensor using Si-wafer direct bonding technology and its characteristics)

  • 정귀상
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제8권2호
    • /
    • pp.165-170
    • /
    • 1995
  • This paper describes the fabrication and characteristics of a Si Hall sensor fabricated on a SOI (Si-on-insulator) structure. The SOI structure was formed by SDB(Si-wafer direct bonding) technology and the insulator of the SOI structure was used as the dielectrical isolation layer of a Hall sensor. The Hall voltage and sensitivity of the implemented SDB SOI Hall sensors showed good linearity with respect to the applied magnetic flux density and supplied current. The product sensitivity of the SDB SOI Hall sensor was average 600V/A.T and its value has been increased up to 3 times compared to that of bulk Si with buried layer of 10.mu.m. Moreover, this sensor can be used at high-temperature, high-radiation and in corrosive environments.

  • PDF