• Title/Summary/Keyword: structure detection

Search Result 2,044, Processing Time 0.033 seconds

Development of PLT($PbLaTiO_{3}$) pyroelectric materials (PLT($PbLaTiO_{3}$) 초전재료 개발(II))

  • Park, Sung-Kun;Bae, Seung-Choon;Kim, Ki-Wan
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.491-499
    • /
    • 1997
  • We fabricated the ceramic PLT tablet which was composed of 5, 10 and 15 mol% lanthanum concentration and thin film PLT to develope pyroelectric materials, and investigated their characteristics. Using TG/DTA, we determined calcination and sintering temperature to sinter the PLT completely and to prevent volatilization of the Pb components. The calcination and sintering temperature were $850^{\circ}C$, $1150^{\circ}C$ respectively, and there was a lot of mass loss at higher sintering temperature. By measuring temperature-dielectric constant characteristics of ceramic tablet we investigated dielectric constant characteristics depends on La concentration. The Curie point of PLT with 5, 10 and 15 mol% lanthanum concentration were $330^{\circ}C$, $269^{\circ}C$ and $210^{\circ}C$ respectively. Using PLT ceramic tablet we observed IR detection characteristics, and then deposited PLT thin film by rf magnetron sputtering. We verified that PLT thin film fabricated with completely sintered PLT target had the same structure to target by investigating lattice constant and optical transparency.

  • PDF

Vehicle Plate Extraction Algorithm for an Exculsive Bus Lane (버스 전용차선에서의 차량 번호판 추출 알고리즘)

  • 설성욱;이상찬;주재흠;강현인;남기곤
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.2 no.4
    • /
    • pp.31-37
    • /
    • 2001
  • License plate recognition system for an exclusive bus-lane is made of 5 core parts which are vehicle detection, image acquisition individual character extraction, character recognition and data transmission. Among them, the accuracy of license plate extraction can bring effect significantly to the accuracy of a whole system recognition rate also the more exact extraction of license plate is required in various weather and environment conditions. Therefore in this paper we propose a plat extraction algorithm that makes pyramid structure to reduced the extraction processing time binarizes plate's template region using adaptive thresholding extracts candidate region containing plate, and verifies a final region using plate character distribution characteristics among the candidates. Experimenal results were exactly extracted the license plate region by using proposed method to the image obtained in an exclusive bus-lane with various weather and environment conditions.

  • PDF

A Study on Web Service Security Testing Methodology for Performance Evaluation (웹 서비스 보안 성능 평가 테스트 방법론 연구)

  • Lee, Dong-Hwi;Ha, Ok-Hyun
    • Convergence Security Journal
    • /
    • v.10 no.4
    • /
    • pp.31-37
    • /
    • 2010
  • The risks and threats in IT security systems to protect, prevent damage and Risk should be minimized. Context of information security products such as information processing, storage, delivery, and in the process of information system security standards, That is the basic confidentiality, availability, integrity and secondary clarity, potential evidence, detection, warning and defense capabilities, to ensure sufficient and should be. Web services are the most important elements in the security, the web nature of port 80 for the service to keep the door open as a structure, Web applications, web sources and servers, networks, and to hold all the elements are fundamental weaknesses. Accordingly, these elements through a set of Web application development errors and set-up errors and vulnerabilities in Web applications using their own home pages and web servers to prevent hacking and to improve the efficiency of Web services is proposed methodology performs security BMT.

Development of Integrated Outlier Analysis System for Construction Monitoring Data (건설 계측 데이터에 대한 통합 이상치 분석 시스템 개발)

  • Jeon, Jesung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.5
    • /
    • pp.5-11
    • /
    • 2020
  • Outliers detection and elimination included in field monitoring datum are essential for effective foundation of unusual movement, long and short range forecast of stability and future behavior to various structures. Integrated outlier analysis system for assessing long term time series data was developed in this study. Outlier analysis could be conducted in two step of primary analysis targeted at single dataset and second multi datasets analysis using synthesis value. Integrated outlier analysis system presents basic information for evaluating stability and predicting movement of structure combined with real-time safety management platform. Field application results showed increased correlation between synthesis value including similar sort of sensor showing constant trend and each single dataset. Various monitoring data in case of showing different trend can be used to analyse outlier through correlation-weighted value.

KVN Observation on Radio-selected AGNs hosted by Elliptical Galaxies

  • Park, Song-Youn;Yi, Suk-Young K.;Sohn, Bong-Won
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.61.1-61.1
    • /
    • 2011
  • We have performed simultaneous observations at 22GHz and 43GHz on AGNs hosted by elliptical galaxies using KVN radio telescope. We have constructed the sample, based on two major surveys in radio and optical band, i.e. Faint Images of the Radio Sky at Twenty-Centimeters (FIRST) and Sloan Digital Sky Survey (SDSS) DR7, respectively. We restricted the redshift range 0.01 < z < 0.06 and the absolute magnitude Mr < -19.4 in order to satisfy volume limited sample. We also checked clear detection of four distinctive emission lines ([NII], [OIII], $H{\alpha}$, $H{\beta}$) so as to utilize on BPT diagram, distinguishing AGNs from star-forming galaxies. Elliptical galaxies have been selected by visual inspection making use of SDSS optical images. Then, we cross-matched the elliptical galaxies with FIRST detections. About 35% of the galaxies have been detected throughout KVN observations. We derive spectral index, applying the flux of different radio frequencies from FIRST (1.4GHz) and KVN (22GHz) and classify into steep, flat or inverted spectrum. We have found that most of the detected galaxies have flat spectrum while the rest of them have steep spectrum. This implies that a number of detected galaxies might have compact structure associated with the central region of the galaxies. The relation between black hole mass and radio luminosity has shown relatively tighter correlation in high frequency than in low frequency, which confirms that high frequency in radio band is appropriate to study the center of the galaxies.

  • PDF

Detecting Incipient Caries Using Front-illuminated Infrared Light Scattering Imaging

  • Kim, Ji-Young;Ro, Jung-Hoon;Jeon, Gye-Rok;Kim, Jin-Bom;Ye, Soo-Young
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.6
    • /
    • pp.310-316
    • /
    • 2012
  • A new method for early caries diagnosis was proposed and tested through a home-made optical examination system that used quantitative light fluorescence (QLF) and digital imaging fiber optic transillumination (FOTI) (DIFOTI), with light sources across a wide spectral range, from 350 nm to 1,000 nm. The front-illuminated infrared light scattering image (FIR) showed similar diagnostic abilities to that of DIFOTI. The FIR method was invented based on the observation that caries lesions lose the high transmittance and low scattering properties of benign enamel tissue. There are various methods for the early diagnosis of caries, such as visual examination, exploration, X-ray radiography, QLF, FOTI, and infrared fluorescence (diagnodent). Among them, methods based on optical properties are regarded as having the most potential. A comparative study was performed between the FOTI, QLF, diagnodent, optical coherence tomography, and FIR scattering image methods, using 20 extracted teeth samples with early caries. A scale of lesion measurement based on optical image contrast was proposed. The statistical analysis showed a significant correlation between the DIFOTI and FIR methods (r = 0.35, p < 0.05). However, the QLF and diagnodent methods showed little association with FIR images, as they have different detection principles as compared with FIR. Tomographic images obtained by OCT, using 1,330 nm super luminescent LED as a gold standard of tooth structure, verified that the FOTI and FIR results correctly represented the lack of homogeneity in dental tissue. The newly proposed FIR method attained similar diagnostic results to those of FOTI, but with an easier approach.

Synthesis and Characterization of Novel pH-Sensitive Hydrogels Containing Ibuprofen Pen dents for Colon-Specific Drug Delivery

  • Mahkam, Mehrdad;Poorgholy, Nahid;Vakhshouri, Laleh
    • Macromolecular Research
    • /
    • v.17 no.9
    • /
    • pp.709-713
    • /
    • 2009
  • The aim of this study was to develop novel intestinal specific drug delivery systems with pH sensitive swelling and drug release properties. The carboxyl group of ibuprofen was converted to a vinyl ester group by reacting ibuprofen and vinyl acetate as an acylating agent in the presence of catalyst. The glucose-6-acrylate-1, 2, 3, 4-tetraacetate (GATA) monomer was prepared under mild conditions. Cubane-1, 4-dicarboxylic acid (CDA) linked to two 2-hydroxyethyl methacrylate (HEMA) group was used as the crosslinking agent (CA). Methacrylic-type polymeric prodrugs were synthesized by the free radical copolymerization of methacrylic acid, vinyl ester derivative of ibuprofen (VIP) and GATA in the presence of cubane cross linking agent. The structure of VIP was characterized and confirmed by FTIR, $^1H$ NMR and $^{13}C$ NMR spectroscopy. The composition of the cross-linked three-dimensional polymers was determined by FTIR spectroscopy. The hydrolysis of drug polymer conjugates was carried out in cel-lophane membrane dialysis bags, and the in vitro release profiles were established separately in enzyme-free simulated gastric and intestinal fluids (SGF, pH 1 and SIF, pH 7.4). The detection of a hydrolysis solution by UV spectroscopy at selected intervals showed that the drug can be released by hydrolysis of the ester bond between the drug and polymer backbone at a low rate. Drug release studies showed that increasing the MAA content in the copolymer enhances the rate of hydrolysis in SIP. These results suggest that these polymeric prodrugs can be useful for the release of ibuprofen in controlled release systems.

Improved antimicrobial effect of ginseng extract by heat transformation

  • Xue, Peng;Yao, Yang;Yang, Xiu-shi;Feng, Jia;Ren, Gui-xing
    • Journal of Ginseng Research
    • /
    • v.41 no.2
    • /
    • pp.180-187
    • /
    • 2017
  • Background: The incidence of halitosis has a prevalence of 22-50% throughout the world and is generally caused by anaerobic oral microorganisms, such as Fusobacterium nucleatum, Clostridium perfringens, and Porphyromonas gingivalis. Previous investigations on the structure-activity relationships of ginsenosides have led to contrasting results. Particularly, the antibacterial activity of less polar ginsenosides against halitosis-related bacteria has not been reported. Methods: Crude saponins extracted from the Panax quinquefolius leaf-stem (AGS) were treated at $130^{\circ}C$ for 3 h to obtain heat-transformed saponins (HTS). Five ginsenoside-enriched fractions (HTS-1, HTS-2, HTS-3, HTS-4, and HTS-5) and less polar ginsenosides were separated by HP-20 resin absorption and HPLC, and the antimicrobial activity and mechanism were investigated. Results: HPLC with diode-array detection analysis revealed that heat treatment induced an extensive conversion of polar ginsenosides (-Rg1/Re, -Rc, -Rb2, and -Rd) to less polar compounds (-Rg2, -Rg3, -Rg6, -F4, -Rg5, and -Rk1). The antimicrobial assays showed that HTS, HTS-3, and HTS-4 were effective at inhibiting the growth of F. nucleatum, C. perfringens, and P. gingivalis. Ginsenosides-Rg5 showed the best antimicrobial activity against the three bacteria, with the lowest values of minimum inhibitory concentration and minimum bactericidal concentration. One major reason for this result is that less polar ginsenosides can more easily damage membrane integrity. Conclusion: The results indicated that the less polar ginsenoside-enriched fraction from heat transformation can be used as an antibacterial agent to control halitosis.

Gas Sensing Characteristics of Nano Sized SnO2 Sensors for Various Co and Ni Concentration (Co, Ni 농도 변화에 따른 나노 SnO2 센서의 감응 특성)

  • Lee, Ji-Young;Yu, Yoon-Sic;Yu, Il
    • Korean Journal of Materials Research
    • /
    • v.21 no.10
    • /
    • pp.546-549
    • /
    • 2011
  • Nano-sized $SnO_2$ thick films were prepared by a screen-printing method onto $Al_2O_3$ substrates. The sensing characteristics were investigated by measuring the electrical resistance of each sensor in a test box as a function of the detection gas. The nano-sized $SnO_2$ thick film sensors were treated in a $N_2$ atmosphere. The structural properties of the nano $SnO_2$with a rutile structure according to XRD showed a (110) dominant $SnO_2$ peak. The particle size of $SnO_2$:Ni nano powders at Ni 8 wt% was about 45 nm, and the $SnO_2$ particles were found to contain many pores according to the SEM analysis. The sensitivity of the nano $SnO_2$-based sensors was measured for 5 ppm $CH_4$ gas and $CH_3CH_2CH_3$ gas at room temperature by comparing the resistance in air with that in the target gases. The results showed that the best sensitivity of $SnO_2$:Ni and $SnO_2$:Co sensors for $CH_4$ gas and $CH_3CH_2CH_3$ gas at room temperature was observed in $SnO_2$:Ni sensors doped with 8 wt% Ni. The response time of the $SnO_2$:Ni gas sensors was 10 seconds and recovery time was 15 seconds for the $CH_4$ and $CH_3CH_2CH_3$ gases.

A Beamforming Method for a Perturbed Linear Towed Array (비선형 형상 견인 어레이를 위한 빔형성 기법)

  • 김승일;도경철;오원천;윤대희;이충용
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.5
    • /
    • pp.478-484
    • /
    • 2002
  • Linear towed arrays (LTA) have a nonlinear shape due to tow vessel motion, ocean swells and currents. By reasons of nominally linear shape, various towed array shape estimation techniques have been developed since the perturbed shape cause the error in target detection. In this paper,, we propose the beamforming method for the perturbed LTA with simple structure. The proposed method linearizes a nonlinear phase of steering vector with position information measured by two reference sensors. It can be proved using some properties of Markov transition matrix, and iteration number of linearization process is decided by variance of cross phase difference. As a result of computer simulation in the ocean environment, beampattern of the proposed method is almost same with the ideal case in my type of array shape. In the signal-to-noise ratio (SNR) performance simlation, the DOA estimation performance of the proposed beamforming method is evaluated, and the comparison with Bartlett beamformer of the LTA shows that the proposed method can estimate. the spatial characteristic of sources more accuracy.