• 제목/요약/키워드: structural performance test

검색결과 2,156건 처리시간 0.026초

플랫 플레이트 슬래브와 H형강 기둥 접합부의 구조 성능에 관한 실험적 연구 (An Experimental Study on Structural Performance of H-Steel or SRC Column and Flat Plate Slab Connection)

  • 윤명호;이윤희;유홍식;김진원
    • 복합신소재구조학회 논문집
    • /
    • 제5권2호
    • /
    • pp.9-14
    • /
    • 2014
  • Main topics in this study is a new structural detail for connection between H-Steel or SRC column and flat plate slab. We carried out to evaluate the punching shear performance of H-steel or SRC column + RC slab system for vertical load and lateral load. From the test results structural characteristics - yield moment, yield rotation, maximum moment, deformation capabilities ect. - are obtained and evaluated. In this paper as a shear reinforcement for supporting region of plate closed stirrup type and shear band are used, and their test results are compared.

Earthquake resistance of structural walls confined by conventional tie hoops and steel fiber reinforced concrete

  • Eom, Taesung;Kang, Sumin;Kim, Okkyue
    • Earthquakes and Structures
    • /
    • 제7권5호
    • /
    • pp.843-859
    • /
    • 2014
  • In the present study, the seismic performance of structural walls with boundary elements confined by conventional tie hoops and steel fiber concrete (SFC) was investigated. Cyclic lateral loading tests on four wall specimens under constant axial load were performed. The primary test parameters considered were the spacing of boundary element transverse reinforcement and the use of steel fiber concrete. Test results showed that the wall specimen with boundary elements complying with ACI 318-11 21.9.6 failed at a high drift ratio of 4.5% due to concrete crushing and re-bar buckling. For the specimens where SFC was selectively used in the plastic hinge region, the spalling and crushing of concrete were substantially alleviated. However, sliding shear failure occurred at the interface of SFC and plain concrete at a moderate drift ratio of 3.0% as tensile plastic strains of longitudinal bars were accumulated during cyclic loading. The behaviors of wall specimens were examined through nonlinear section analysis adopting the stress-strain relationships of confined concrete and SFC.

벽식 구조체 적용을 위한 구조용단열패널 성능 평가 (Evaluation on Structural Performance of Structural Insulated Panels in Wall Application)

  • 나환선;이현주;이철희;황성욱;조혜진;최성모
    • 복합신소재구조학회 논문집
    • /
    • 제3권2호
    • /
    • pp.19-27
    • /
    • 2012
  • Structural insulated panels, which are structurally performed panels consisting of a plastic insulation bonded between two structural panel facings are one of emerging products with a viewpoint of its energy and construction efficiencies. These components are applicable to fabricated wood structures. By now, there are few technical documents regulated structural performance and engineering criteria in domestic market. This study was conducted to suggest fundamental reports such as racking resistance, axial capacity, transverse load capacity, and lintel load capacity for SIPs. Test results showed that maximum load was 44.3kN, allowable load was 14.7kN for racking resistance, and that maximum load was 137.6kN, allowable load was 37.4kN/m for axial compression capacity. For transverse load capacity, test results showed $10.3kN/m^2$ of maximum load, $3.4kN/m^2$ of allowable load. For lintel load capacity for SIPs dependent to lengths, allowable loads were 20.4kN for 600mm long lintel, 23.9kN for 1,200mm long lintel, 19.3kN for 1,800mm long lintel, and 2,400mm long lintel had 14.1kN of allowable load. In the near future, when the allowable load for wall application is established, SIPs is considered to substitute the existent post-and-lintel construction to bearing wall structure.

완화된 단부 배근상세를 갖는 특수전단벽 구조시스템의 내진성능평가 (Seismic Performance of Special Shear Wall Structural System with Effectively Reduced Reinforcement Detail)

  • 천영수;이기학;이효원;박영은;송진규
    • 콘크리트학회논문집
    • /
    • 제25권3호
    • /
    • pp.271-281
    • /
    • 2013
  • 구조형식별로 구조물의 안정성 확보를 위해 KBC2009에 새로이 도입된 높이제한에 따라, 내진설계범주D에 해당되는 60 m 이상의 RC 구조물을 계획할 경우 특수전단벽을 의무적으로 사용해야 한다. 그러나 특수전단벽의 엄격한 횡보강 배근상세는 시공성 및 경제성에 부정적 영향을 미칠 것으로 예상된다. 그래서 이 연구에서는 현 규준에 따른 특수전단벽보다 완화된 배근 상세를 갖는 특수전단벽을 제안하고, 특수전단벽과의 성능 비교를 위하여 각각 두 개의 실험체를 제작하고 횡방향 반복 하중실험을 실시하였다. 또한 그 실험 결과를 반영한 보통전단벽, 특수전단벽, 완화된 특수전단벽 구조시스템의 해석모델을 설계하여 FEMA P695에 따른 방법론으로 내진성능평가를 실시하였다.

Effectiveness of seismic repairing stages with CFRPs on the seismic performance of damaged RC frames

  • Duran, Burak;Tunaboyu, Onur;Kaplan, Onur;Avsar, Ozgur
    • Structural Engineering and Mechanics
    • /
    • 제67권3호
    • /
    • pp.233-244
    • /
    • 2018
  • This study aims at evaluating the performance of repairing technique with CFRPs in recovering cyclic performance of damaged columns in flexure in terms of structural response parameters such as strength, dissipated energy, stiffness degradation. A 2/3 scaled substandard reinforced concrete frame was constructed to represent the substandard RC buildings especially in developing countries. These substandard buildings have several structural deficiencies such as strong beam-weak column phenomenon, improper reinforcement detailing and poor material properties. Flexural plastic hinges occurred at the columns ends after testing the substandard specimen under both constant axial load and reversed cyclic lateral loading. Afterwards, the damaged columns were externally wrapped with CFRP sheets both in transverse and longitudinal directions and then retested under the same loading protocol. In addition, ambient vibration measurements were taken from the undamaged, damaged and the repaired specimens at each structural repair steps to identify the effectiveness of each repairing step by monitoring the change in the natural frequencies of the tested specimen. The ambient vibration test results showed that the applied repairing technique with external CFRP wrapping was proved to recover stiffness of the pre-damaged specimen. Moreover, the lateral load capacity of the pre-damaged substandard RC frame was restored with externally bonded CFRP sheets.

Lateral confining action of mortar-filled sleeve reinforcement splice

  • Kim, Hyong-Kee;Lee, Sang-Ho
    • Structural Engineering and Mechanics
    • /
    • 제41권3호
    • /
    • pp.379-393
    • /
    • 2012
  • Of the various methods of splicing reinforcing bar in reinforced concrete structure, mortar-filled sleeve reinforcement splice offers diverse benefits, not only in terms of structural performance but also for the construction process. Consequently, after the mortar-filled sleeve splices have been developed in recent years, research and development on these splices has been actively carried out, in order to evaluate its macro structural performance, such as its strength and stiffness, with the aim of enabling this system to be applied to construction in the field as early as possible. However, to make a proper evaluation on the overall structural performance of the mortar-filled sleeve reinforcing bar splice, it is of critical importance to understand the lateral confining action of the sleeve, which is known to affect the bond strength between the embedded bar and mortar in the sleeve. Accordingly, in this study, an experiment of monotonic loading and cyclic loading was conducted with a full-sized mortar-filled sleeve splice attaching strain gauges on the sleeve surface with experimental variables such as development length of bar, etc. Based on the test results, the effect of the lateral confining action of the sleeve was analyzed and considered in terms of the bond strength between the bar and mortar in this splice.

영구 터널지보재로서의 활용을 위한 GFRP 록볼트의 역학적 거동 분석 (Analysis for Mechanical Behavior of GFRP Rock Bolt for Permanent Support of Tunnel)

  • 심종성;강태성;이용택;김현중
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권6호
    • /
    • pp.124-131
    • /
    • 2010
  • 록볼트는 주변 지반의 지보 기능을 유리하게 활용하기 위한 부재로서 일반적으로 소요의 강도 이상을 가진 강재로 된 이형봉강을 활용하고 있다. 그러나, 부식성 요소가 많은 지하수 조건에서는 강재의 부식으로 인한 록볼트의 파괴로 터널 및 사면안정의 보수, 보강 및 유지관리 문제가 많이 발생하게 된다. 이러한 문제를 해결하고 영구적으로 사용가능한 터널 지보재로 활용하기 위한 실질적인 거동을 모사하여 GFRP 록볼트의 거동에 대한 실험적 평가를 실시하였다. 이 연구는 GFRP 록볼트의 인장성능 평가시험 및 전단성능 평가시험을 통해 도출된 GFRP 록볼트의 구조적 특성을 바탕으로 구조해석을 통한 사면안정해석을 실시하여 안전율을 평가하였다. 실험 결과 기존에 사용하던 강재 록볼트의 대체 재료로서 충분히 터널 지반의 안정성을 확보 할 수 있을 것으로 판단된다.

구조보강용 FRP 함침·접착수지의 사용가능시간 분석 (Pot Life of Structural Adhesives for FRP Composite Used in Strengthening RC Members)

  • 최기선;유영찬;김긍환
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권3호
    • /
    • pp.191-198
    • /
    • 2008
  • FRP 복합체의 함침 접착에 사용되는 에폭시 수지와 같은 2액형 접착제는 두 성분을 상호 혼합함으로써 경화반응이 시작되며, 일정 시간이 경과되면 접착제의 점도와 온도가 급격히 증가된다. 이와 같이 접착제의 점도가 증가되면 작업성과 접착력이 저하되므로, 현장에서의 작업은 시공연도(workability)가 유지되는 한계, 소위 "사용가능시간(pot life)" 이내에 완료되어야만 한다. 본 연구에서는 구조보강용 FRP 복합체의 함침 접착에 사용되는 에폭시 수지의 사용가능시간을 평가하기 위하여 기존에 제안되고 있는 점도변화법 및 발열온도상승법의 적합성을 검증하고, 실험결과의 비교 분석을 통하여 구조용 접착제의 사용가능시간을 보다 합리적으로 산정할 수 있는 시험방법 및 평가기준을 제안하였다.

원심성형 콘크리트의 투수시험을 통한 균열 자기치유 성능평가 (Evaluation of Crack Self-healing Performance in Centrifugal Molding Concrete by Permeability Test)

  • 황철성;우해식;최영철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권3호
    • /
    • pp.84-89
    • /
    • 2018
  • 최근 자기치유 재료에 대한 연구는 보수하기 힘들거나, 보수비용이 많이 소요되는 구조물에 대해 구조물 스스로 손상을 치유하여 사용수명을 증가시키기 위해 많이 수행되어오고 있다. 현재 널리 사용되고 있는 자기치유 평가 방법으로는 투수시험이 있다. 하지만, 자기치유 평가 방법에서 자기치유 성능은 콘크리트의 초기 균열 폭에 큰 영향을 받지만 일관된 기준을 가지고 있지 않은 실정이다. 따라서, 본 연구에서는 기존 연구에서 사용한 균열 폭과 투수량을 기반으로 균열 폭-투수량의 상관관계와 시간-투수량의 상관관계를 분석하였다. 또한, 광학현미경을 이용하여 측정한 초기 균열 폭은 신뢰성이 떨어지므로 Poiseuille flow에서 ${\alpha}$값을 도출하여 시간-균열 폭에 대한 상관관계를 분석하여 시간-투수량과 시간-균열 폭에 대한 경향을 분석하였다.

원형 RC 기둥의 내진성능과 휨 초과강도 (Seismic Performance and Flexural Over-strength of Circular RC Column)

  • 고성현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권5호
    • /
    • pp.49-58
    • /
    • 2013
  • 축소모형 원형기둥 실험체 8개를 제작하여 일정한 축력 하에서 반복 횡하중을 가력하는 실험을 수행하였다. 실험체들은 형상비 4.5인 실험체로 설계되었다. 실험체의 주요변수는 횡방향철근비, 축방향철근비, 축방향철근 항복강도와 축력비이다. 기둥 실험체들의 실험결과들은 축방향철근비, 횡철근비와 축력비에 따라 등가점성비, 잔류변형, 유효강성등과 같은 내진성능이 다르게 나타났다. 낮은 항복강도의 축방향철근이 적용된 실험체는 등가점성감쇠비와 잔류변형과 같은 내진성능이 낮게 나타났다. 국내의 도로교설계기준에 휨 초과강도 규정이 2012년에 채택되었다. 실험결과들은 공칭강도, 비선형 모멘트-곡률 해석 결과, AASHTO LRFD 및 도로교설계기준 (한계상태설계법)과 같은 기준들과 비교하였다.