• Title/Summary/Keyword: structural fire resistant design

Search Result 18, Processing Time 0.018 seconds

Comparative Study of Beams made up of Fire Resistant Steels (내화강재 적용 단순 보부재의 고온 거동 비교 연구)

  • Kwon, In-Kyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.111-112
    • /
    • 2017
  • Fire is very serious condition in steel based structures. Therefore, to enhance the structural stability of columns and beams in high temperatures, fire resistant steels and TMC fire resistant steels are developed from steel manufacturing companies. In this study to evaluate the structural stability and compare the resistant performance, a fire engineering design method was applied and fire resistant steels showed the better performance than other two materials.

  • PDF

A Study on the Design Fire Model for Structural Fire Resistant Design in Buildings (건축구조물의 구조내화설계를 위한 설계화재모델에 관한 연구)

  • Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.256-257
    • /
    • 2019
  • Recently, the fire risk of architectural structures is increasing due to the super high - rise and super - size of the buildings. Therefore, the direction of fire safety design tends to change from the existing design to the performance - based design. In particular, domestic fire safety policies are divided into building law and fire fighting law. In case of fire fighting law, performance design is already carried out. Therefore, this study summarizes the prediction formula for fire characteristics among the structural fireproofing design field as shown in Fig. 1 according to this situation, and compares it with the standard method of each country in particular.

  • PDF

Evaluation on the Mechanical Properties of Fire Resistant Steels at High Temperature Conditions with Manufacturing Processes (제조 방식에 따른 건축용 내화강재의 고온 시 기계적 특성 평가)

  • Kwon, In Kyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.2
    • /
    • pp.181-190
    • /
    • 2007
  • A fire-resistant steel with enhanced load-bearing capacity has been developed to enable structural elements such as columns and beams withstand exposure to severe fire conditions. To precisely evaluate the fire-resistant performance of structural elements that compose fire-resistant steels, mechanical properties such as yield strength and elastic modulus are essential. To obtain the mechanical database of fire-resistant steels at high temperatures, tensile tests at high temperatures were conducted on steels of two kinds of thicknesses. The results showed that the thickness difference could not affect the mechanical properties at a high temperature.

On the Chinese Code on fire safety design of steel building structures

  • Li, G.Q.;Guo, S.X.;Jiang, S.C.
    • Steel and Composite Structures
    • /
    • v.5 no.5
    • /
    • pp.395-405
    • /
    • 2005
  • This work introduces to the international scientific community the Chinese Code on fire safety design of steel building structures. The aim of the Code is to prevent the structure of a steel building subjected to fire from collapsing, ensure safe evacuation of building occupants, and reduce the cost for repairing the damages of the structure caused by fire. The main contents of the Code is presented in this paper, including the fire duration requirements of structural components, fundamental requirements on fire safety design of steel components, temperature increasing of atmosphere and components in fire, loading effect and capacity of various components in fire, and procedure for fire-resistant design of steel components. The analytical approach is employed in the Code and the effectiveness of the Code is validated through experiments.

A simplified analysis of catenary action in steel beams in fire and implications on fire resistant design

  • Wang, Y.C.;Yin, Y.Z.
    • Steel and Composite Structures
    • /
    • v.6 no.5
    • /
    • pp.367-386
    • /
    • 2006
  • This paper describes the results of a numerical investigation of the large deflection behaviour of steel beams under fire conditions, taking into consideration the effect of catenary action provided by the surrounding structures. The main focus is on the development, validation and application of a simplified calculation method that may be adopted in design calculations. Because no experimental result is available for validation of the simplified calculation method, the finite element program ABAQUS has been used to simulate the large deflection behaviour of a number of steel beams so as to provide alternative results for validation of the proposed method. Utilising catenary action has the potential of eliminating fire protection to all steel beams without causing structural failure in fire. However, practical application of catenary action will be restricted by concerns over large beam deflection causing integrity failure of the fire resistant compartment and additional cost of strengthening the connections and the surrounding structures to resist the catenary forces in the steel beams. This paper will provide a discussion on practical implications of utilising catenary action in steel beams as a means of eliminating fire protection. A number of examples will then be provided to illustrate the type of steel framed structure that could benefit the most from exploiting catenary action in fire resistant design.

The First Performance-based Structural Fire Design for Office Building in Korea

  • Min Jae Park
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.3
    • /
    • pp.235-239
    • /
    • 2023
  • In this study, the fire resistance performance of the concrete-filled steel tube (CFT) columns and thin steel-plate composite (TSC) beams installed at a 20-story office building were designed using a performance-based structural fire design. Because of the lack of any specific provisions in the building code and guidelines for structural engineers about the performance-based approach, the only prescriptive approach has been selected for designing fire-resistant structures in Korea. To evaluate the fire resistance performance of the CFT columns and TSC beams, finite element analysis verified by the experimental results studied by several researchers was conducted with ABAQUS. From the fire scenario, the temperature distributions of the CFT columns and TSC beams were found via finite element analysis and the behaviors of the CFT columns and TSC beams were investigated in the structural field based on the temperature distribution.

Structural performance of unprotected concrete-filled steel hollow sections in fire: A review and meta-analysis of available test data

  • Rush, David;Bisby, Luke;Jowsey, Allan;Melandinos, Athan;Lane, Barbara
    • Steel and Composite Structures
    • /
    • v.12 no.4
    • /
    • pp.325-350
    • /
    • 2012
  • Concrete filled steel hollow structural sections (CFSs) are an efficient, sustainable, and attractive option for both ambient temperature and fire resistance design of columns in multi-storey buildings and are becoming increasingly common in modern construction practice around the world. Whilst the design of these sections at ambient temperatures is reasonably well understood, and models to predict the strength and failure modes of these elements at ambient temperatures correlate well with observations from tests, this appears not to be true in the case of fire resistant design. This paper reviews available data from furnace tests on CFS columns and assesses the statistical confidence in available fire resistance design models/approaches used in North America and Europe. This is done using a meta-analysis comparing the available experimental data from large-scale standard fire tests performed around the world against fire resistance predictions from design codes. It is shown that available design approaches carry a very large uncertainty of prediction, suggesting that they fail to properly account for fundamental aspects of the underlying thermal response and/or structural mechanics during fire. Current North American fire resistance design approaches for CFS columns are shown to be considerably less conservative, on average, than those used in Europe.

The Chinese Performance-based Code for Fire-resistance of Steel Structures

  • Li, Guo-Qiang;Zhang, Chao
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.2
    • /
    • pp.123-130
    • /
    • 2013
  • In the past two decades, researchers from different countries have conducted series of experimental and theoretical studies to investigate the behaviour of structures in fire. Many new insights, data and calculation methods have been reported, which form the basis for modern interdisciplinary structural fire engineering. Some of those methods are now adopted in quantitative performance-based codes and have been migrated into practice. Mainly based on the achievements in structural fire research at China, the Chinese national code for fire safety of steel structures in buildings has been drafted and approved, and will be released in this year. The code is developed to prevent steel structures subjected to fire from collapsing, ensure safe evacuation of building occupants, and reduce the cost for repairing the damages of the structure caused by fire. This paper presents the main contents of the code, which includes the fire duration requirements of structural components, fundamental requirements on fire safety design of steel components, temperature increasing of atmosphere and structural components in fire, loading effect and capacity of various components in fire, and procedure for fire-resistant check and design of steel components. The analytical approaches employed in the code and their validation works are also presented.

Study for the Method to Secure the Safety of Fire-fighters in the Building Damaged by a Fire by Using Fire-resistant Design Theories - Mainly about Suggesting the Process and the Method for a Real-time Safety Evaluation by a Fire-fighter - (화재손상 건축 구조물에서 내화설계 이론을 활용한 소방관 안전확보 방안에 관한 연구 - 소방관에 의한 실시간 안전성평가 절차 및 방법의 제안을 중심으로 -)

  • Kwon, Yeongbae;Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.86-95
    • /
    • 2016
  • Weight-bearing building materials are substantially weakened under high temperatures, and this is evident through the collapse of structures once engulfed by fire. Currently, there is no scientific or technological process of evaluating the real-time structural stability of a building whcih is engulfed by flame. There are many building design specifications which aim to reduce the risk of fire, but little consideration given to fire officer safety while operating in a dangerous building. This paper aims to provide direction within building policy in order to ensure the safe evacuation of fire-fighters in case of an impending building collapse. This paper suggests evaluation criteria for buildings which are damaged due to fire, autilizing current information on fire-resistant building design and a fire-resistant capacity.