• 제목/요약/키워드: stress shielding

검색결과 79건 처리시간 0.025초

흡수성 고정판과 나사를 이용한 중수골 골절의 치료 (Treatment of Metacarpal Bone Fracture Using Biodegradable Plates and Screws)

  • 조정목;은석찬;백롱민
    • Archives of Plastic Surgery
    • /
    • 제38권4호
    • /
    • pp.458-464
    • /
    • 2011
  • Purpose: Metacarpal fractures are common hand injury that may require operative intervention to ensure adequate reduction and stabilization. Traditionally, titanium miniplate was used for rigid fixation of bone fractures. However, the use of permanent plate lends itself to multiple complications such as infection, exposure of the hardware, tendon adhesions, tendon rupture, prolonged pain, bony atrophy and osteoporosis (stress shielding), metal sensitization, and palpation under the skin. This study evaluated the usefulness and stability of biodegradable plates and screws for treatment of metacarpal bone fractures. Methods: There was 17 patients who had surgery for metacarpal bone fracture from April 2007 to June 2010. All patients had open reduction and internal fixation. We used absorbable plates and screws (Inion CPS$^{(R)}$) for internal fixation. Postoperative results were assessed with x-ray. Stability of plates and screws, healing process and its complications were observed by clinical and radiographic assessment. Results: All patients were successfully reduced of bone fracture, and fixations with absorbable plates and screws were stable. The mean follow up period was 7.1 months. 2 patients complained postoperative pain, but they were relieved with analgesics. All patients experienced transient stiffness, but they were relieved with active assistive range of motion after removal of splint. No patients suffered complications which could be occurred by using metallic plate. Conclusion: There was no critical complications such as re-fracture or nonunion among patients. No patients suffered side effects related with metallic implants. Biodegradable implants can offer clinically stable and attractive alternative to metallic implants to stabilize metacarpal bone fractures in the hand.

가압경수로형 사용후핵연료 처분용기의 예비 개념설계 평가 (Assessment of a Pre-conceptual Design of a Spent PWR Fuel Disposal Container)

  • 최종원;조동건;이양;최희주;이종열
    • 방사성폐기물학회지
    • /
    • 제4권1호
    • /
    • pp.41-50
    • /
    • 2006
  • 본 연구에서는 사전연구로부터 사용후핵연료의 처분용기 원형모델로 제안된 처분용기의 전체 크기와 배열을 평가하기 위하여 일련의 공학적 분석을 수행하였다. 그러한 노력의 결과 용기 내부 저장통의 배열형태와 외곽쉘과 상하부 뚜껑의 두께와 같은 새로운 설계변수를 도출하였다. 공학적 분석 작업에는 처분용기의 기계구조 해석 결과를 근거로 도출된 용기의 규격자료에 대한 방사선 안전성 측면에서의 타당성을 검토하기 위하여 방사선차폐 해석과 핵 임계 해석 등이 수행되었다. 처분용기 내부 삽입체의 직경 변화에 따른 구조안정성 해석 결과에 따르면, 직경 102cm 일 때 극한 외압조건은 물론 정상적인 외압조건 하에서도 최대 Von Mises 응력이 안전계수 2.0을 만족하는 것으로 나타났다. 이 경우에서도 핵 임계 및 방사선차폐 해석 결과 안전기준치를 만족시키며, 무게는 20톤 가량 줄어드는 효과가 있는 것으로 나타났다.

  • PDF

가압경수로형 사용후핵연료 처분용기의 예비 개념설계 평가 (Pre-conceptual Design of a Spent PWR Fuel Disposal Container)

  • 최종원;조동건;이양;최희주;이종열
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2005년도 추계 학술대회 논문집
    • /
    • pp.153-162
    • /
    • 2005
  • 본 연구에서는 사전연구로부터 사용후 핵연료의 처분용기 원형모델로 제안된 처분용기의 전체 크기와 배열을 평가하기 위하여 일련의 공학적 분석을 수행하였다. 그러한 노력의 결과 용기 내부 저장통의 배열형태와 외곽쉘과 상하부뚜껑의 두께와 같은 새로운 설계변수를 도출하였다. 공학적 분석 작업에는 처분용기의 기계구조 해석 결과를 근거로 도출된 용기의 규격자료에 대한 방사선 안전성 측면에서의 타당성을 검토하기 위하여 방사선차폐 해석과 핵임계 해석 등이 수행되었다. 처분용기 내부 삽입체의 직경변화에 따른 구조안정성 해석 결과에 따르면, 직경 102cm일 때 극한 외압조건은 물론 정상적인 외압조건 하에서도 최대 Von Mises 응력이 안전계수 2.0을 만족하는 것으로 나타났다. 이 경우에도 핵임계 및 방사선차폐 해석 결과 안전기준치를 만족시키며, 무게는 20톤 가량 줄어드는 효과가 있는 것으로 나타났다.

  • PDF

신생아집중간호단위 환경과 저체중출생아의 반응에 대한 연구 (A Study on the Environment for Lowbirth Weight Infants in Neonatal Intensive Care Unit in the United States)

  • 한경자
    • Child Health Nursing Research
    • /
    • 제4권2호
    • /
    • pp.159-176
    • /
    • 1998
  • In effort to conduct comparative study on the caregiving environment of Neonatal Intensive Care Unit(NICU) in both U. S and Korea, this study was been conducted first in the U.S. Purpose : The purpose of this study is to identify the physical environment and direct caregiving practices to lowbirth weight infants in NICU in the US. It also aims to examine the NICU outcome status and behavioral reponses of lowbirth weight infants. Methods : A study design using descriptive and inferential statistics was been conducted through an observational, field method. A sample of 15 preform infants admitted to NICU were recruited for the study. The subjects were those with birth weight between 1,000 gm to 1,500 gm, born at the gestation period of 27 to 33 weeks, and without any chromosomal or other genetic anomalies, major congenital infections, or maternal illness. Thirty minutes observation(three times of ten minutes of continuous observation)of the infant's behavior and physiological status, and an four-hour observation of the physical environment and direct care giving procedures were been conducted on the 3rd and 10th day after birth, and on the day of discharge from the NICU or at 34weeks postconception. The data to be collected were in four areas : the demograghic characteristics of the infants, the physical environment and care giving procedures, the frequency of the infant's designated behavior and physiological response, and NICU outcome variables. A descriptive analysis and Kruskal-Wallis, Pearson r were been applied according to variable characteristics. Results : 1. Mother's mean age was 29.47. The sample consisted of 6 males and 9 females. Mean gestational ages were 29.17 weeks. Mean birth weight was 1236.33g. Mean Apgar scores at one minute were 6.6, and 7.8 at five minutes. 2. The location for the incubator was in the distance from the light, X-ray screens and nursing station, in proximity to side-lamp, telephone and faucet on the third day after birth. The location for the incubator was in the distance from the light and radio on the tenth day and in proximity to nursing station on the day of dischage from the NICU or at 34weeks postconception. 3. Nesting was the most applying aids to the infants. And foot roll, shielding and plastic frame were frequently using by nurses for facilitating well modulated restful posture. 4. There were statistically significant changes in the patterns of physical environment included locating the infant's incubator and bedding, specific aids to self regulation on the 3rd and 10th day after birth, and on the day of discharge from the NICU or at 34weeks postconception. 5. Statistically significant changes were not appeared in the patterns of direct caregiving procedure to the infants included stress inducing or reducing manipulations on the 3rd and 10th day after birth, and on the day of discharge from the NICU or at 34weeks postconception. 6. The stress response of the infants in NICU were significantly reduced as the infants grow older. 7. There were not statistically significant correlation between the physical envronment and the stress responses of the infants in NICU. 8. There were statistically significant correlation between the direct caregiving procedure to the infants and the stress response of the infants in NICU in the second and third observation on the day three. 9. Average weight gain per day from birth to discharge was 38.73g, number of days in the hospital was 42.60, number of days before bottle feeding was 3.6. Postconception age starting bottle feed ing was 31/sup +5/ weeks. Number of days on mechanical ventilator was average 7.64, 11.42 was an average number of days of oxygen need. Conclusion : It, thus, appears that to minimize the sensorymotor stimulation for the low birthweight preterm infant in NICU, manipulation of care giving practices to the babies whatever the stress inducing or reducing procedures, have to be limited in the immediate early stage after birth. And it needed to be reexamine to identify the appropriate and specific physical environment and the patterns of direct caregiving to the low birthweight preform infant as the infants grow older in NICU.

  • PDF

Corrosion Characteristics of Cell-Covered Ternary Ti-Nb-Ta Alloy for Biomaterials

  • Kim, W.G.;Yu, J.W.;Choe, H.C.;Ko, Y.M.;Park, G.H.
    • Corrosion Science and Technology
    • /
    • 제8권2호
    • /
    • pp.62-67
    • /
    • 2009
  • Ti and Ti-alloys have good biocompatibility, appropriate mechanical properties and excellent corrosion resistance. However, the widely used Ti-6Al-4V is found to release toxic ions (Al and V) into the body, leading to undesirable long-term effects. Ti-6Al-4V has much higher elastic modulus (100 GPa) than cortical bone (20 GPa). Therefore, titanium alloys with low elastic modulus have been developed as biomaterials to minimize stress shielding. The electrochemical behavior of surface-modified and MC3T3-E1 cell-cultured Ti-30(Nb,Ta) alloys with low elastic modulus have been investigated using various electrochemical methods. Surfaces of test samples were treated as follows: $0.3{\mu}m$ polished; $25{\mu}m$, $50{\mu}m$ and $125{\mu}m$ sandblasted. Specimen surfaces were cultured with MC3T3-E1 cells for 2 days. Average surface roughness ($R_a$) and morphology of specimens were determined using a surface profilometer, OM, and FE-SEM. Corrosion behavior was investigated using a potentiostat(EG&G PARSTAT 2273), and electrochemical impedance spectroscopy was performed (10 mHz to 100 kHz) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The microstructures of the Ti-30(Ta,Nb) alloys had a needle-like appearance. The $R_a$ of polished Ti-30Ta and Ti-30Nb alloys was lower than that of the sandblasted Ti alloy. Cultured cells displayed round shapes. For polished alloy samples, cells were well-cultured on all surfaces compared to sandblasted alloy samples. In sandblasted and cell-cultured Ti-30(Nb,Ta) alloy, the pitting potential decreased and passive current density increased as $R_a$ increased. Anodic polarization curves of cell-cultured Ti alloys showed unstable behavior in the passive region compared to non-cell-cultured alloys. From impedance tests of sandblasted and cell-cultured alloys, the polarization resistance decreased as $R_a$ increased, whereas, $R_a$ for cell-cultured Ti alloys increased compared to non-cell-cultured Ti alloys.

선체외판부 3.2T 박판에 대한 SAW 용접 적용에 관한 연구 (A Study on the Application of SAW Process for Thin Plate of 3.2 Thickness in Ship Structure)

  • 오종인;윤진오;임동용;정상훈;이정수
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2010년도 춘계학술발표대회 초록집
    • /
    • pp.51-51
    • /
    • 2010
  • Recently just as in the automobile industry, shipbuilders also try to reduce material consumption and weight in order to keep operating costs as low as possible and improve the speed of production. Naturally industry is ever searching for welding techniques offering higher power, higher productivity and a better quality. Therefore it is important to have a details research based on the various welding process applied to steel and other materials, and to have the ability both to counsel interested companies and to evaluate the feasibility of implementation of this process. Submerged-arc welding (SAW) process is usually used about 20% of shipbuilding. Similar to gas metal arc welding(GMAW), SAW involves formation of an arc between a continuously-fed bare wire electrode and the work-piece. The process uses a flux to generate protective gases and slag, and to add alloying elements to the weld pool and a shielding gas is not required. Prior to welding, a thin layer of flux powder is placed on the work-piece surface. The arc moves along the joint line and as it does so, excess flux is recycled via a hopper. Remaining fused slag layers can be easily removed after welding. As the arc is completely covered by the flux layer, heat loss is extremely low. This produces a thermal efficiency as high as 60% (compared with 25% for manual metal arc). SAW process offers many advantages compared to conventional CO2 welding process. The main advantages of SAW are higher welding speed, facility of workers, less deformation and better than bead shape & strength of welded joint because there is no visible arc light, welding is spatter-free, fully-mechanized or automatic process, high travel speed, and depth of penetration and chemical composition of the deposited weld metal. However it is difficult to application of thin plate according to high heat input. So this paper has been focused on application of the field according to SAW process for thin plate in ship-structures. For this purpose, It has been decided to optimized welding condition by experiments, relationship between welding parameters and bead shapes, mechanical test such as tensile and bending. Also finite element(FE) based numerical comparison of thermal history and welding residual stress in A-grade 3.2 thickness steel of SAW been made in this study. From the result of this study, It makes substantial saving of time and manufacturing cost and raises the quality of product.

  • PDF

TiN/Ti 다층막 코팅된 생체용 Ti-30Ta-xZr 합금의 부식특성 (Corrosion Characteristics of TiN/Ti Multilayer Coated Ti-30Ta-xZr Alloy for Biomaterials)

  • 김영운;조주영;최한철
    • Corrosion Science and Technology
    • /
    • 제8권4호
    • /
    • pp.162-169
    • /
    • 2009
  • Pure titanium and its alloys are drastically used in implant materials due to their excellent mechanical properties, high corrosion resistance and good biocompatibility. However, the widely used Ti-6Al-4V is found to release toxic ions (Al and V) into the body, leading to undesirable long-term effects. Ti-6Al-4V has much higher elastic modulus than cortical bone. Therefore, titanium alloys with low elastic modulus have been developed as biomaterials to minimize stress shielding. For this reason, Ti-30Ta-xZr alloy systems have been studied in this study. The Ti-30Ta containing Zr(5, 10 and 15 wt%) were 10 times melted to improve chemical homogeneity by using a vacuum furnace and then homogenized for 24 hrs at $1000^{\circ}C$. The specimens were cut and polished for corrosion test and Ti coating and then coated with TiN, respectively, by using DC magnetron sputtering method. The analyses of coated surface were carried out by field emission scanning electron microscope(FE-SEM). The electrochemical characteristics were examined using potentiodynamic (- 1500 mV~+ 2000 mV) and AC impedance spectroscopy(100 kHz~10 mHz) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The equiaxed structure was changed to needle-like structure with increasing Zr content. The surface defects and structures were covered with TiN/Ti coated layer. From the polarization behavior in 0.9% NaCl solution, The corrosion current density of Ti-30Ta-xZr alloys decreased as Zr content increased, whereas, the corrosion potential of Ti-30Ta-xZr alloys increased as Zr content increased. The corrosion resistance of TiN/Ti-coated Ti-30Ta-xZr alloys were higher than that of the TiN-coated Ti-30Ta-xZr alloys. From the AC impedance in 0.9% NaCl solution, polarization resistance($R_p$) value of TiN/Ti coated Ti-30Ta-xZr alloys showed higher than that of TiN-coated Ti-30Ta-xZr alloys.

Expression and Localization of Heat Shock Protein 70 in Frozen-Thawed IVF and Nuclear Transfrred Bovine Embryos

  • Park, Y.J;S.J Song;J.T Do;B.S Yoon;Kim, A.J;K.S Chung;Lee, H.T
    • 한국수정란이식학회:학술대회논문집
    • /
    • 한국수정란이식학회 2002년도 국제심포지엄
    • /
    • pp.78-78
    • /
    • 2002
  • The role of heat shock proteins in shielding organism from environmental stress is illustrated by the large-scale synthesis of these protein by the organism studied to date. However, recent evidence also suggests an important role for heat shock protein in fertilization and early development of mammalian embryos. Effects of elevated in vitro temperature on in vitro produced bovine embryos were analysed in order to determine its impact on the expression of heat shock protein 70 (HSP70) by control and frozen-thawed after in vitro fertilization (IVF) or nuclear transfer (NT). The objective of this study was to assess the developmental potential in vitro produced embryos with using of the various containers and examined expression and localization of heat shock protein 70 after it's frozen -thawed. For the vitrification, in vitro produced embryos at 2 cell, 8 cell and blastocysts stage after IVF and NT were exposed the ethylene glycol 5.5 M freezing solution (EG 5.5) for 30 sec, loaded on each containers such EM grid, straw and cryo-loop and then immediately plunged into liquid nitrogen. Thawed embryos were serially diluted in sucrose solution, each for 1 min, and cultured in CRI-aa medium. Survival rates of the vitrification production were assessed by re-expanded, hatched blastocysts. There were no differences in the survival rates of IVF using EM grid, cryo-loop. However, survival rates by straw were relatively lower than other containers. Only, nuclear transferred embryos survived by using cryo-loop. After IVF or NT, in vitro matured bovine embryos 2 cell, 8 cell and blastocysts subjected to control and thawed conditions were analysed by semiquantitive reverse transcription polymerase chain reaction methods for hsp 70 mRNA expression. Results revealed the expression of hsp 70 mRNA were higher thawed embryos than control embryos. Immunocytochemistry used to localization the hsp70 protein in embryos. Two, 8-cell embryos derived under control condition was evenly distributed in the cytoplasm but appeared as aggregates in some embryos exposed frozen-thawed. However, under control condition, blastocysts displayed aggregate signal while Hsp70 in frozen-thawed blastocysts appeared to be more uniform in distribution.

  • PDF

미세 배선 적용을 위한 Ta/Cu 적층 구조에 따른 계면접착에너지 평가 및 분석 (Effect of Ta/Cu Film Stack Structures on the Interfacial Adhesion Energy for Advanced Interconnects)

  • 손기락;김성태;김철;김가희;주영창;박영배
    • 마이크로전자및패키징학회지
    • /
    • 제28권1호
    • /
    • pp.39-46
    • /
    • 2021
  • Cu 배선(interconnect) 적용을 위한 다층박막의 적층 구조에 따른 최적 계면접착에너지(interfacial adhesion energy, Gc) 평가방법을 도출하기 위해, Ta, Cu 및 tetraethyl orthosilicate(TEOS-SiO2) 박막 계면의 정량적 계면접착에너지를 double cantilever beam(DCB) 및 4-점 굽힘(4-point bending, 4-PB) 시험법을 통해 비교 평가하였다. 평가결과, Ta확산방지층이 적용된 시편(Cu/Ta, Cu/Ta/TEOS-SiO2)에서는 두 가지 평가방법 모두 반도체 전/후 공정에서 박리가 발생하지 않는 산업체 통용 기준인 5 J/㎡ 보다 높게 측정되었다. Ta/Cu 시편의 경우 DCB 시험에서만 5 J/㎡ 보다 낮게 측정되었다. 또한, DCB시험 보다 4-PB시험으로 측정된 Gc가 더 높았다. 이는 계면파괴역학 이론에 따라 이종재료의 계면균열 선단에서 위상각의 증가로 인한 계면 거칠기 및 소성변형에 의한 에너지 손실이 증가 하는것에 기인한다. 4-PB시험결과, Ta/Cu 및 Cu/Ta계면은 5 J/㎡ 이상의 높은 계면접착에너지를 보이므로, 계면접착에너지 관점에서는 Ta는 Cu배선의 확산방지층(diffusion barrier layer) 및 피복층(capping layer)으로 적용 가능할 것으로 생각된다. 또한, 배선 집적공정 및 소자의 사용환경에서 열팽창 계수 차이에 의한 열응력 및 화학적-기계적 연마 (chemical mechanical polishing)에 의한 박리는 전단응력이 포함된 혼합모드의 영향이 크므로 4-PB 시험으로 측정된 Gc와 연관성이 더 클 것으로 판단된다.