• Title/Summary/Keyword: stress range frequency

Search Result 205, Processing Time 0.027 seconds

Thermal-Mechanical and Low Cycle Fatigue Characteristics of 12Cr Heat Resisting Steel with Hold Time Effects (유지시간 효과를 고려한 12Cr 내열강의 열피로 및 저주기 피로 특성)

  • Ha, J.S.;Koh, S.K.;Ong, J.W.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.1
    • /
    • pp.1-12
    • /
    • 1995
  • Isothermal and thermal-mechanical fatigue characteristics of 12Cr heat resisting steel used for high temperature applications were investigated including hold time effects. Isothermal low cycle fatigue test at $600^{\circ}C$ and in-phase, out-of-phase thermal-mechanical fatigue test at 350 to $600^{\circ}C$ were conducted using smooth cylindrical hollow specimen under strain-control with total strain ranges from 0.006 to 0.015. Regardless of thermal-mechanical and isothermal fatigue tests, cyclic softening behavior was observed and much more pronounced in the thermal-mechanical fatigue tests with hold times due to the stress relaxation during the hold time. The phase difference between temperature and strain in thermal-mechanical fatigue tests resulted in significantly shorter fatigue life for out-of-phase compared to in-phase. The differences in fatigue lives were dependent upon the magnitudes of plastic strain ranges and mean stresses. During the hold time in the strain-controlled fatigue tests, the increase in the plastic strain range and the stress relaxation were observed. It appeared that the increase in plastic strain range per cycle and the introduction of creep damage made important contributions to the reduction of thermal-mechanical fatigue life with hold time, and the life reduction tendency was more remarkable in the in-phase than in the out-of-phase thermal-mechanical fatigue. Isothermal fatigue tests performed under the combination of fast and slow strain rates at $600^{\circ}C$ showed that the fatigue life decreased as the strain rate and frequency decreased,especially for the low strain ranges.

  • PDF

A Study on Design Criteria of Piping System in Petrochemical Plant (석유화학 플랜트의 배관계 설계기준에 대한 연구)

  • Min, Sun-Kuo;Choi, Myung-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.6
    • /
    • pp.192-199
    • /
    • 2002
  • Largely, there are three kinds of the design criteria of piping system in petrochemical plant. The first is on the pipe thickness in accordance with the design pressure of piping system. The second is on the static state evaluation by thermal growth and the other is on the dynamic evaluation by piping vibration. According to the ASME B31.3 code, the internal pressure design thickness fur straight pipe shall be calculated as a code formula. And the static design by thermal displacement is defined 7000 cycles of fatigue life in operating the piping system with a design condition. However, the dynamic design evaluation in comparative with small displacements of high frequencies to the static condition has not established clearly the method, yet. So, this study purposes to present the trial of a proposal of dynamic design criterion on the basis of static design method.

Performance analyses of antagonistic shape memory alloy actuators based on recovered strain

  • Shi, Zhenyun;Wang, Tianmiao;Da, Liu
    • Smart Structures and Systems
    • /
    • v.14 no.5
    • /
    • pp.765-784
    • /
    • 2014
  • In comparison with conventional shape memory actuated structures, antagonistic shape memory alloy (SMA) actuators permits a fully reversible two-way response and higher response frequency. However, excessive internal stress could adversely reduce the stroke of the actuators under repeated use. The two-way shape memory effect might further decrease the range of the recovered strain under actuation of an antagonistic SMA actuator unless additional components (e.g., spring and stopper) are added to regain the overall actuation capability. In this paper, the performance of all four possible types of SMA actuation schemes is investigated in detail with emphasis on five key properties: recovered strain, cyclic degradation, response frequency, self-sensing control accuracy, and controllable maximum output. The testing parameters are chosen based on the maximization of recovered strain. Three types of these actuators are antagonistic SMA actuators, which drive with two active SMA wires in two directions. The antagonistic SMA actuator with an additional pair of springs exhibits wider displacement range, more stable performance under reuse, and faster response, although accurate control cannot be maintained under force interference. With two additional stoppers to prevent the over stretch of the spring, the results showed that the proposed structure could achieve significant improvement on all five properties. It can be concluded that, the last type actuator scheme with additional spring and stopper provide much better applicability than the other three in most conditions. The results of the performance analysis of all four SMA actuators could provide a solid basis for the practical design of SMA actuators.

Effect of Guar Gum on Rheological Properties of Acorn Flour Dispersions

  • Yoo, Byoung-Seung;Shon, Kwang-Joon;Chang, Young-Sang
    • Food Science and Biotechnology
    • /
    • v.14 no.2
    • /
    • pp.233-237
    • /
    • 2005
  • Rheological properties of acorn flour-guar gum mixtures (4% w/w) at different guar gum concentrations (0, 0.2, 0.4, 0.6, and 0.8% w/w) were evaluated in steady and dynamic shear. The acorn flour-guar gum mixtures at $25^{\circ}C$ showed high shear-thinning flow behavior (n= 0.20-0.27). Consistency index (K), apparent viscosity (${\eta}_{a,100}$), and Casson yield stress (${\sigma}_{oc}$) increased with the increase in guar gum concentration. Within the temperature range of $25-70^{\circ}C$, the {\eta}_{a,100}$ of mixtures obeyed the Arrhenius relationship with high determination coefficient ($R^2=\;0.974-0.994$). Activation energy values (5.37-6.77 kJ/mole) of acorn flour dispersions in the mixtures with guar gum (0.2-0.8%) were much lower than that (12.5 kJ/mole) of acorn flour dispersion (0% guar gum). Storage modulus (G'), loss modulus (G"), and complex viscosity (${\eta}^*$) increased with the increase in guar gum concentration. Dynamic rheological data of 1n (G', G") versus ln frequency (w) of guar gum-acorn flour mixtures had positive slopes with G' greater than G" over most of the frequency range, indicating that they exhibited weak gel-like behavior.

Measurement of AC Hysteresis Loops under Variable Tensile Stress for Amorphous Wire (비정질 세선의 인장응력에 따른 교류자기이력 특성측정)

  • 조희정;양종만;손대락;김구영
    • Journal of the Korean Magnetics Society
    • /
    • v.3 no.1
    • /
    • pp.61-64
    • /
    • 1993
  • We have constructed a hysteresis loop tracer in order to measure the magnetic properties of amorphous wires under variable tensile stress. It has a force range of 0 N to 20 N and a magnetizing frequency of 1 kHz to 20 kHz. Using the ac-hysteresis loop tracer, we can measure the magnetic properties(maximum magnetic induction $B_{max}$, residual magnetic induction $B_{r}$, coercive field strength $H_{c}$, etc.) of amorphous wires with precision of 1% under variable tensile stresses.

  • PDF

The Effect of Variable Electric Fields on the PZT Characteristic and Laminate Configuration in LIPCA (LIPCA에 공급되는 전기장의 변화가 PZT 특성과 적층배향에 미치는 영향)

  • Kim Cheol-Woong;Nam In-Chang;Yoon Kwang-Joon
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.397-398
    • /
    • 2006
  • The advanced piezoelectric ceramic composite actuator, which is called LIPCA with the FRP and the optimization of the laminate configuration, was performed to maximize the stress transfer and the fiber bridging effect. This study evaluated the effect of variable electric fields on the PZT characteristic, laminate configuration and fatigue characteristics under the resonance frequency, which meant the largest performance range and the changes of its interlaminar phase were also evaluated by stages. In conclusions, Comparing with the fatigue lift of intact LIPCA, the fatigue life of LIPCA embedded by the artificial delamination was decreased up to 50%. The micro void growth and the coalescence of epoxy were actively made at the interlaminar phase subject to the large tensile stress.

  • PDF

New current source inverter with load-side energy recovery circuit (부하측에 에너지 회생회로를 갖는 전류원 인버터)

  • Chung, Y.H.;Cho, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.117-120
    • /
    • 1988
  • A new current source inverter (CSl) with dc-side commutation and load-side energy recovery circuit is proposed with analysis and explanation of the circuit operation. Proposed inverter overcomes the most drawbacks of the conventional CSI's - high device voltage stress, low operating frequency range, large commutation capacitance, etc. - by employing simultaneous recovery and commutation concept. The new CSI employs only one commutation capacitor and it can be built with considerably low cost. The commutation energies are temporarily stored into a large dc capacitor and recovered to the load side, thus the device voltage stress is low and the efficiency is high in the proposed inverter. Computer simulation results are given at the steady state, and a guideline determining the commutation circuit is given.

  • PDF

Factors Influencing Organizational Commitment among Hospital Nurses (병원 간호사의 조직몰입 영향 요인)

  • Park, Geum-Ja;Kim, Yo-Na
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.16 no.3
    • /
    • pp.250-258
    • /
    • 2010
  • Purpose: The purpose of this study is to examine the effective factors of organizational commitment among hospital nurses. Method: The subjects were 250 registered nurses working in 3 hospitals in Busan. Data were obtained by self-reported questionnaires from the 10th of June to 30th of June, 2009. Data were analyzed by frequency and percentage, t-test, ANOVA and Sheffe's test and stepwise multiple regression. Result: Mean of job satisfaction was $60.56{\pm}9.25$ (range of scale: 20-100), internal marketing was 69.49 (range of scale: 25-125), job stress obtained $100.60{\pm}17.93$ (range of scale: 45-180), and organizational commitment got $47.78{\pm}6.84$ (range of scale: 15-75). The extent of the organizational commitment had differences according to the age (F=3.300, p=.039), educational level (F=3.21, p=.042), religion (F=3.30, p=.021), position (F=5.837, p=.003), and career length (F=2.642, p=.035). The influencing factors in organizational commitment of hospital nurses were job satisfaction, internal marketing, and age. $R^2$=.503. The job satisfaction has the highest significant predictor of organizational commitment. Conclusion: The influencing factors on organizational commitment were job satisfaction, internal marketing and age. Thus it is needed to improve the job satisfaction and internal marketing of hospitals' nurses and to provide care and support to younger nurses.

Inductor Characteristics of the Active Clamp Forward Converter for Adapter (어댑터용 능동클램프 포워드 컨버터 인덕터 특성)

  • Jang, Duk-Kyu;Woo, Seung-Hun;Kim, Chang-Sun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.6
    • /
    • pp.1064-1069
    • /
    • 2010
  • Active clamp forward converter provides zero voltage switching, low voltage stress and wide input voltage range. The design technique leads to getting a higher efficiency under high switching frequency and optimal operating range. It is designed for notebook computer adapter with free input voltage and 19.5V/120W output ratings. The efficiency is measured to more than 90%. One of the most important circuit parts is the filter inductor besides the transformer in active clamp forward converter. In this paper, the process of inductor design is listed optimally.

An Evaluation of the Fatigue Properties for External Panel Using Low Density SMC (저비중 SMC 외장패널의 피로특성 평가)

  • Kim, Eun-Sung
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.5
    • /
    • pp.830-835
    • /
    • 2012
  • A research for application of LDSMC(Low Density Sheet Molding Compound) composite is in progress for lightening the weight. This paper has performed fatigue test and simulation of external panel for Korean commercial vehicle. Before the fatigue test, static test was carried out. From the test, the structural safety was investigated using Goodman diagram. After the static test performance, the fatigue test was conducted at a range of load frequency 5Hz, a stress ratio(R) of 0.05 and an endurance limit of $10^6$ to obtain the S-N curve. The S-N curve is applied to the fatigue analysis of the external panel assembly. The result of FEM analysis was in accord with the experimental result within 83% confidence. It showed that the process to set up the safety range of allowable error is required in process of the design and simulation verification.