• 제목/요약/키워드: strength modifying factor

검색결과 8건 처리시간 0.023초

A new strength model for the high-performance fiber reinforced concrete

  • Ramadoss, P.;Nagamani, K.
    • Computers and Concrete
    • /
    • 제5권1호
    • /
    • pp.21-36
    • /
    • 2008
  • Steel fiber reinforced concrete is increasingly used day by day in various structural applications. An extensive experimentation was carried out with w/cm ratio ranging from 0.25 to 0.40, and fiber content ranging from zero to1.5 percent by volume with an aspect ratio of 80 and silica fume replacement at 5%, 10% and 15%. The influence of steel fiber content in terms of fiber reinforcing index on the compressive strength of high-performance fiber reinforced concrete (HPFRC) with strength ranging from 45 85 MPa is presented. Based on the test results, equations are proposed using statistical methods to predict 28-day strength of HPFRC effecting the fiber addition in terms of fiber reinforcing index. A strength model proposed by modifying the mix design procedure, can utilize the optimum water content and efficiency factor of pozzolan. To examine the validity of the proposed strength model, the experimental results were compared with the values predicted by the model and the absolute variation obtained was within 5 percent.

Seismic structural demands and inelastic deformation ratios: a theoretical approach

  • Chikh, Benazouz;Mebarki, Ahmed;Laouami, Nacer;Leblouba, Moussa;Mehani, Youcef;Hadid, Mohamed;Kibboua, Abderrahmane;Benouar, Djilali
    • Earthquakes and Structures
    • /
    • 제12권4호
    • /
    • pp.397-407
    • /
    • 2017
  • To estimate the structural seismic demand, some methods are based on an equivalent linear system such as the Capacity Spectrum Method, the N2 method and the Equivalent Linearization method. Another category, widely investigated, is based on displacement correction such as the Displacement Coefficient Method and the Coefficient Method. Its basic concept consists in converting the elastic linear displacement of an equivalent Single Degree of Freedom system (SDOF) into a corresponding inelastic displacement. It relies on adequate modifying or reduction coefficient such as the inelastic deformation ratio which is usually developed for systems with known ductility factors ($C_{\mu}$) and ($C_R$) for known yield-strength reduction factor. The present paper proposes a rational approach which estimates this inelastic deformation ratio for SDOF bilinear systems by rigorous nonlinear analysis. It proposes a new inelastic deformation ratio which unifies and combines both $C_{\mu}$ and $C_R$ effects. It is defined by the ratio between the inelastic and elastic maximum lateral displacement demands. Three options are investigated in order to express the inelastic response spectra in terms of: ductility demand, yield strength reduction factor, and inelastic deformation ratio which depends on the period, the post-to-preyield stiffness ratio, the yield strength and the peak ground acceleration. This new inelastic deformation ratio ($C_{\eta}$) is describes the response spectra and is related to the capacity curve (pushover curve): normalized yield strength coefficient (${\eta}$), post-to-preyield stiffness ratio (${\alpha}$), natural period (T), peak ductility factor (${\mu}$), and the yield strength reduction factor ($R_y$). For illustrative purposes, instantaneous ductility demand and yield strength reduction factor for a SDOF system subject to various recorded motions (El-Centro 1940 (N/S), Boumerdes: Algeria 2003). The method accuracy is investigated and compared to classical formulations, for various hysteretic models and values of the normalized yield strength coefficient (${\eta}$), post-to-preyield stiffness ratio (${\alpha}$), and natural period (T). Though the ductility demand and yield strength reduction factor differ greatly for some given T and ${\eta}$ ranges, they remain take close when ${\eta}>1$, whereas they are equal to 1 for periods $T{\geq}1s$.

이중골조시스템으로 설계된 복강판-모듈러 구조물의 반응수정계수에 관한 연구 (Study on the Response Modification Factor for a Lightweight Steel Panel-Modular Structure Designed as a Dual Frame System)

  • 이어진;홍성걸
    • 한국지진공학회논문집
    • /
    • 제15권1호
    • /
    • pp.39-48
    • /
    • 2011
  • 본 연구에서는 복강판-모듈러 시스템과 같이 구조 기준에 명시되지 않은 새로운 시스템의 반응수정계수를 산정하는 절차를 제안하였다. 기본 개념은 구조성능 실험결과를 바탕으로 모델링 된 시스템의 비선형 정적 해석 곡선으로부터 세부 구성요소인 초과강도계수와 연성계수의 도출하고, 단자유도 시스템으로 간주하고 평가된 반응수정계수를 다자유도 동적 거동을 고려한 다자유도 밑면전단 수정계수로 수정하여 시스템의 최종적인 반응수정계수를 결정하는 것이다. 제안한 절차에 따라 이중골조시스템으로 설계된 2층부터 5층까지의 복강판-모듈러 시스템에 대해 평가한 결과, 최종적인 반응수정계수는 5층(층고 4m기준)을 복강판-모듈러 시스템의 적용 가능한 층수의 상한으로 하여 4로 결정하는 것이 타당할 것으로 판단하였다.

Shear behavior of RC interior joints with beams of different depths under cyclic loading

  • Xi, Kailin;Xing, Guohua;Wu, Tao;Liu, Boquan
    • Earthquakes and Structures
    • /
    • 제15권2호
    • /
    • pp.145-153
    • /
    • 2018
  • Extensive reinforced concrete interior beam-column joints with beams of different depths have been used in large industrial buildings and tall building structures under the demand of craft or function. The seismic behavior of the joint, particularly the relationship between deformation and strength in the core region of these eccentric reinforced concrete beam-column joints, has rarely been investigated. This paper performed a theoretical study on the effects of geometric features on the shear strength of the reinforced concrete interior beam-column joints with beams of different depths, which was critical factor in seismic behavior. A new model was developed to analyze the relationship between the shear strength and deformation based on the Equivalent Strut Mechanism (ESM), which combined the truss model and the diagonal strut model. Additionally, this paper developed a simplified calculation method to estimate the shear strength of these type eccentric joints. The accuracy of the model was verified as the modifying analysis data fitted to the test results, which was a loading test of 6 eccentric joints conducted previously.

고유동 자기충전 콘크리트와 이형철근의 부착특성 (The Bond Characteristics of Deformed Bars in High Flowing Self-Compacting Concrete)

  • 최연왕;정재권;김경환;안태호
    • 대한토목학회논문집
    • /
    • 제29권5A호
    • /
    • pp.511-518
    • /
    • 2009
  • 본 연구에서는 콘크리트와 철근과의 부착강도에 영향을 미치는 요인 중 철근의 위치를 수평하부철근(Horizontal reinforcement at Bottom position, HB), 수평상부철근(Horizontal reinforcement at Top position, HT), 및 수직철근(Vertical reinforcement type, V)으로 변화시킨 시험체를 제작하여 3수준의 콘크리트 강도 변화(30, 50 및 70 MPa)에 따른 고유동 자기충전 콘크리트(High flowing Self-compacting Concrete, HSCC) 및 일반콘크리트(Conventional Concrete, CC)와 이형철근의 부착 특성을 비교 분석 하였다. HSCC 및 CC의 상부근 철근계수를 평가하기 위하여 HB/HT 철근의 부착강도비를 측정한 결과 50 및 70 MPa의 경우 HB/HT의 부착강도비는 1.3이하로 나타났으며, 30 MPa의 경우 HSCC 및 CC에서 각각 1.2 및 2.1로 나타났다. 따라서 HSCC 30, 50 및 70 MPa의 경우 콘크리트구조설계기준(2007) 정착길이 설계시 상부근 계수에 제시되는 수평상부철근에 대한 정착길이 보정계수를 CC의 1.3보다는 감소시켜 적용하는 것이 바람직할 것으로 판단된다.

강섬유 보강 콘크리트 구조물의 해석을 위한 K&C모델의 보정 (Modified K&C Model for Numerical Analysis of Steel-Fiber-Reinforced Concrete Structure)

  • 박강규;이민주
    • 한국전산구조공학회논문집
    • /
    • 제34권2호
    • /
    • pp.85-91
    • /
    • 2021
  • 본 연구에서는 섬유보강콘크리트(SFRC) 구조물의 수치해석을 위한 K&C모델의 보정기법을 소개하였다. SFRC 1축 및 3축 압축강도 실험결과를 기반으로 보정을 수행하였으며, 단일요소 해석결과를 실험결과와 비교함으로써 보정 기법의 검증을 수행하였다. 또한, 변형률 속도의 영향을 반형하기 위해 동적증가계수(DIF)를 고려하여 SFRC 구조물의 발사체 관통해석을 수행함으로써 보정기법의 적용 가능성을 확인하였다.

PTFE 막의 표면 개질 방법 (Surface Modification of Poly(tetrafluoroethylene) (PTFE) Membranes)

  • 장준규;윤채원;박호범
    • 멤브레인
    • /
    • 제33권1호
    • /
    • pp.1-12
    • /
    • 2023
  • 본 총설은 소수성 불소수지계 분리막의 표면 개질에 대한 개론으로 다양한 표면 개질 방법 및 그 연구 결과를 중점적으로 서술하였다. PTFE로 대표되는 불소수지계 고분자 분리막은 막 증류, 유수 분리, 기체 분리를 포함한 다양한 막 분리 공정에서 사용되어왔다. PTFE 막은 내화학성, 내열성, 높은 기계적 강도와 같은 뛰어난 물성에도 불구하고 소수성 표면 특성으로 인해 기술 적용의 확장에 제한적이다. 친수성 향상을 위해 습식 화학법, 친수성 고분자 코팅, 플라즈마 처리, 조사, 원자층 증착과 같은 다양한 PTFE 표면 개질 방법을 이용하며 이를 통해 불소수지계 분리막의 응용분야가 확장될 수 있다.

상온 재활용 아스팔트 혼합물의 적정 유화아스팔트 함량 선정 연구 (Study on the Proper Emulsified-Asphalt Content for a Cold-Recycling Asphalt Mixture)

  • 양성린;손정탄;이강훈
    • 한국도로학회논문집
    • /
    • 제20권1호
    • /
    • pp.47-58
    • /
    • 2018
  • PURPOSES : The purpose of this study is to evaluate the mechanical properties of a cold-recycling asphalt mixture used as a base layer and to determine the optimum emulsified-asphalt content for ensuring the mixture's performance. METHODS : The physical properties (storage stability, mixability, and workability) of three types of asphalt emulsion (CMS-1h, CSS-1h, and CSS-1hp) were evaluated using the rotational viscosity test. Asphalt emulsion residues, prepared according to the ASTM D 7497-09 standard, were evaluated for their rheological properties, including the $G*/sin{\delta}$and the dynamic shear modulus (${\mid}G*{\mid}$). In addition, the Marshall stability, indirect tensile strength, and tensile-strength ratio (TSR) were evaluated for the cold-recycling asphalt mixtures fabricated according to the type and contents of the emulsified asphalt. RESULTS : The CSS-1hp was found to be superior to the other two types in terms of storage stability, mixability, and workability, and its $G*/sin{\delta}$ value at high temperatures was higher than that of the other two types. From the dynamic shear modulus test, the CSS-1hp was also found to be superior to the other two types, with respect to low-temperature cracking and rutting resistance. The mixture test indicated that the indirect tensile strength and TSR increased with the increasing emulsified-asphalt content. However, the mixtures with one-percent emulsified-asphalt content did not meet the national specification in terms of the aggregate coverage (over 50%) and the indirect tensile strength (more than 0.4 MPa). CONCLUSIONS : The emulsified-asphalt performance varied greatly, depending on the type of base material and modifying additives; therefore, it is considered that this will have a great effect on the performance of the cold-recycling asphalt pavement. As the emulsified-asphalt content increased, the strength change was significant. Therefore, it is desirable to apply the strength properties as a factor for determining the optimum emulsified-asphalt content in the mix design. The 1% emulsified-asphalt content did not satisfy the strength and aggregate coverage criteria suggested by national standards. Therefore, the minimum emulsified-asphalt content should be specified to secure the performance.