• Title/Summary/Keyword: stream side

Search Result 294, Processing Time 0.046 seconds

Channels Packed with Porous Media to Improve Water Quality for Irrigation Reservoirs (관개용 저수지 수질개선을 위한 접촉산화수로)

  • Park, Byung-Heun;Jang, Jung-Ryul;Kim, Young-Kyeong;Lee, Kwang-Sik;Kwun, Soon-Kuk
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.2
    • /
    • pp.122-127
    • /
    • 2000
  • A stream purification system was applied to the upper reaches of the Masan Reservoir to improve the water quality. This system consisted of two channels which were constructed on both sides of the stream, one side packed with crushed gravels and the other with plastic filter media. The system operated under low pollutant concentrations and high hydraulic loadings during a dry season to avoid clogging of the filter media. Removal rate and efficiency of chemical oxygen demand (COD) in the channel packed with crushed gravel were $14.8g/m^3/d$ and 11.5%, and for the channel with plastic filter media, $50.1g/m^3/d$ and 13.5%, respectively. Removal efficiencies of total phosphorus (T-P) were 6.6% (gravel) and 10.0% (plastic media). These results indicated plastic filter media having relatively high specific surface areas were more efficient than crushed gravels in removing pollutants. However, due to low influent water quality during dry season, the removal efficiencies were low. The proportion of nitrate nitrogen to total nitrogen (T-N) of the inflow was high but, as the system operated under aerobic condition, nitrate nitrogen could not denitrified. Accordingly, total nitrogen was not attenuated with this system. To improve the reservoir water quality effectively, this system should be able to treat the storm runoff containing higher pollutant loadings. When the filter materials are clogged by the storm runoff instead of backwashing, it would be more efficient to replace them, Therefore, the use of natural materials which are light, easily obtaining and replaceable, and have high specific surface areas is recommended.

  • PDF

한국산 검정망둑(Tridentiger obscurus)과 민물검정망둑(T.brevispinis)의 분류학적 고찰

  • 김종범;양서영
    • Animal Systematics, Evolution and Diversity
    • /
    • v.11 no.3
    • /
    • pp.359-377
    • /
    • 1995
  • Morphological and isozyme analyses were used to examine closely related species of Tridentiger obscurus and \ulcorner: brevispinis, a pair of cryptic species which has intricate problem with regard to species boundary, and to clarify the taxonomic position. In this study, it was revealed from their 17 allopatric streams that there are differences of band ornamentation on the lateral side and three genetic markers between two species. However, genetic relationship between them (S = 0.813, D = 0.192) was within the intraspecific level of similarity. However, at the sympatry of two species no hybrid was found except at Bangjuk stream where the electrophoretic hybrids with slight deficiency of heterozygosity were observed. It is shown that at sympatry there is a finer microenvironmental subdivision between two species at all populations including Bangjuk stream. To manifest the extent of assortative mating, four syrnpatric subpopulations at Bangjuk stream were analyzed for departure from Hardy-Weinberg equillibrium by F-statistics. All subpopulations were deviated significantly from the expectation under random mating. The evidences presented here supports the recognition of Tridentiger obscurus and T. brevispinis as semispecies in the late stage of reproductive isolation

  • PDF

Respiratory air flow measuring technique without sensing element on the flow stream (호흡경로 상에 감지소자가 없는 새로운 호흡기류 계측기술)

  • Lee, In-Kwang;Park, Jun-Oh;Lee, Su-Ok;Shin, Eun-Young;Kim, Kyung-Chun;Kim, Kyung-Ah;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.294-300
    • /
    • 2009
  • Cardiopulmonary resuscitation(CPR) is performed by artificial ventilation and thoracic compression for the patient under emergent situation to maintain at least the minimum level of respiration and blood circulation for life survival. Quality of the pre-hospital CPR not only significantly affects the patient's survival rate but also minimizes side effects caused by CPR. Good quality CPR requires monitoring respiration, however, traditional respiratory air flow transducers cannot be used because the transducer elements are located on the flow axis. The present study developed a new technique with no physical object on the flow stream but enabling the air flow measurement and easily incorporated with the CPR devices. A turbulence chamber was formed in the middle of the respiratory tube by locally enlarging the cross-sectional area where the flow related turbulence was generated inducing energy loss which was in turn converted into pressure difference. The turbulence chamber was simply an empty enlarged air space, thus no physical object was placed on the flow stream, but still the flow rate could be evaluated. Both inspiratory and expiratory flows were obtained with symmetric measurement characteristics. Quadratic curve fitting provided excellent calibration formula with a correlation coefficient>0.999 (P<0.0001) and the mean relative error<1 %. The present results can be usefully applied to accurately monitor the air flow rate during CPR.

Flow Analysis due to the Configuration of Automotive Spoiler (자동차 스포일러의 형상에 따른 유동해석)

  • Han, Moonsik;Cho, Jaeung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.6
    • /
    • pp.677-683
    • /
    • 2016
  • In this study, the pressures due to air resistances on the models of 1, 2, 3 and 4 as the automotive bodies grafted on various spoilers are investigated through the flow analysis. Model 1 has the flat type and model 2 has the shape that a flat plane is projected. Model 3 is attached with the slanted plate and model 4 has the shape that two slanted plates are installed on both sides. At the flow streams on the models of 1, 2, 3 and 4, the flow velocities are shown to become highest above the roofs of automotive bodies. The maximum flow velocities are also shown at the beginning points at the roofs of car bodies on the side planes of automotive bodies. The maximum pressures of 102,500 to 102,553 Pa as air resistances are shown at the bumpers of the front car bodies. The flow velocities on the inlet and middle planes become nearly same at the models of 1, 2, 3 and 4. But these velocities on the inlet plane at model 2 projected with the spoiler of flat plate become lower than the models of 1, 3 and 4. The air streams throughout the models become uniform at all models. The flow stream is shown most uniformly at model 2 projected with the spoiler of flat plate. But the flow stream is shown most irregularly at model 3 projected with the spoiler of slanting plate. By using the result of this flow analysis, it is thought to reduce the power of car effectively in driving by changing the configuration of automotive spoiler.

The Experimental Study of the End-to-side Microarterial Anastomosis with the Longitudinal Slit and the Triangular Flap (고전적 및 삼각조각 기법을 이용한 단-측면 미세동맥 접합술의 실험적 연구)

  • Lee, Jun-Mo;Lee, Gang-Wook;Lee, Dong-Geun
    • Archives of Reconstructive Microsurgery
    • /
    • v.1 no.1
    • /
    • pp.51-55
    • /
    • 1992
  • Problems of composite tissue transfer commonly arise when a single indispensable recipient vessel receives the graft vssel, and the graft vessel must be sutured in end-to-side fashion so as not todisturb the vascularity of the recipient vessel. The triangular flap in the recipient vessel wall gives an intact endothelial surface when the flow of blood stream is presented and may reduce the chance of anastomosis. We selected mature Wistar rats weighing over 450 grams to compare the conventional longitudinal slit from the triangular flap in the recipient carotid artery over bloood pressure and blood flow when the donor carotid artery was anastomosed in end-to-side fashion. In 30 minutes after anastomosis, maximum blood pressure measured in the donor carotid arterial side when the recipient arterial wall was fasioned with the longitudinal slit was recorded 114 mmHg and with the triangular flap 100mmHg. Minimum blood pressure with the longitudinal slit was 98mmHg and with the triangular flap 88mmHg. The amount of blood collected for 30 seconds in the conventional longitudinal slit was 1.18mg and in the triangular flap 0.78mg. Histology study in 30 minutes, the conventional longitudinal slit demonstrated the more hemorrhagic features around the suture material compared to that of the triangular. flap and, in the 7th day, the conventional longitudinal slit demonstrated the more prominent granulomatous reactions and vascular proliferations around the suture material compared to that of the triangular flap.

  • PDF

Scour Prediction at Piers in the Bo Cheong Stream (보청천내(報靑川內) 교각설치(橋脚設置)에 따른 국부(局部) 세굴심도(洗掘深度)의 산정(算定))

  • Ahn, Sang Jin;Choi, Gyu Woon;Kim, Jong Sub;Ahn, Chang Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.3
    • /
    • pp.93-105
    • /
    • 1993
  • In this paper, the maximum scour depths at piers located in the Bo Cheong Stream, which is a tributary in the Geum River System, were calculated and compared using 24 local pier scour equations. The equations were classified as six groups by non-dimensional types of equations. The geometric data in the stream bed and pier data at San Seong, Yi Pyung and San Gye, which are IHP data collection stations, were utilized for applying the scour equations. The geometric data in the stream bed were obtained by analyzing the bed material sampled in three stations which are in the left side, middle and right side for stream direction. The maximum flow velocities at maximum flow depths which were measured from 1982 to 1991, were used as the hydraulic flow data. The pier data for predicting pier scour depths were measured in the fields. The maximum pier scour depths calculated using the equations were compared with the held scour depths measured in the streams or rivers in the world. Arunachalam, Shen-Karaki III, Jain-Fischer equations are selected as the proper local scour equations for predicting the maximum local scour depths at piers in the Bo Cheong Stream. Inglis-Lacey and Shen-Karaki II equations are applicable in case of rapid flows conditions in which Froude number is over 0.3. Froehlich, Laursen I, Laursen II, Neill, Melville equations are applicable in the slow flow conditions in which Froude number is less than 0.3. Blench equation or Inglis-Poona equation varies rapidly by changing Froude numbers. Therefore the equations should not be used without careful considerations in selecting the applicable ranges. The maximum local scour depths calculated using Sarma-Krishnamurthy, Ahmad, Coleman, Varzeliotis, Larras, Bata, Chitale, Venkatadri, Basik-Basamily-Ergun, U.S.G.S., Shen I equations are usually less than the scour depths measured in the fields.

  • PDF

Computational Fluid Analysis for Otter Boards ( 1 ) - Pattern of Fluid Flow Besides Otter Board - (전개판에 대한 수치해석 ( 1 ) - 전개판 주위에서의 유체흐름의 패턴 -)

  • Ko, Kwan-Soh;Kwon, Byeong-Guk;Ro, Ki-Deok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.26 no.4
    • /
    • pp.333-340
    • /
    • 1990
  • The authors carried out a visiualizational model test by the hydrogen bubble method to examine the pattern of the fluid flow besides the simple camber type and plane type otter board in circulation water channel. The experimental conditions are velocity of flow 0.05 and 0.1m/sec, angle of attack 0$^{\circ}$~45$^{\circ}$(5$^{\circ}$step). The results obtained are as follows: 1. In the case of the simple camber type otter board located angle of attack 25$^{\circ}$, vortex at the leading edge was geneated at 1/2 of chord length. 2. Size of the vortex generated in the trailing edge was about 2~3 times larger then that of the leading edge. 3. In the case of the simple camber type otter board located angle of attack 30$^{\circ}$, separation of stream-line at leading edge was generated at 1/3 of chord length. 4. Nearest stream-line in the back side of the simple camber type otter board was bent in the direction of otter board when the angle of attack was 25$^{\circ}$ and 30$^{\circ}$, and in the case of plane type otter board was expanded outside of the flow direction. 6. Area separated of the simple camber type otter board at the angle of attack 30$^{\circ}$ was smaller then that of plane type otter board. 7. Flow speed in the back side of the simple camber type otter board was about 1.4 times faster then that in the front side, and in the case of the plane otter board about 1.2 times faster.

  • PDF

Consideration on the Moat of Wolseong Fortress at Gyuongju (경주 월성의 해자(垓字)에 대한 고찰)

  • Jung, Yong-Jo;Park, Joo-Sung;Sim, Woo-Kyung
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.28 no.2
    • /
    • pp.37-44
    • /
    • 2010
  • Our country traditionally employed a defensive system against the aggression by foreign powers by using a town castle and mountain castle. The moat was one of such a defensive system; however, there is few research work on a moat in comparison with its long history. This study was carried out to see the process of the changes of the Wolseong Fortress at Gyuongju, focused on the moat of the scale and nature of the construction methods to analyze such a Wolseong Fortress at Gyuongju as a result of consideration through bibliographical study, on-site investigation, and interviews, etc. This research discovered some facts as follows: the moats of Wolseong fortress at Gyeongju are roughly divided into three types; the first one is a natural moat flowing curved by the south side of Wolseong using the natural stream[Namcheon]as it is; the second one is a pond-type moat made by digging up plane non-rectangular pond along stereobate of castle wall with lakefront built with stream pebbles, and the last one is masonry moat at the east side of Wolseong with chisel-trimmed granites orderly piled in a plane triangular form. Among these, the pond-type moat was identified at the east-north-west side of Wolseong and the pond slopes from east to west as a separate one constructed with the terraces.

A Study on the Improvement of Indoor Thermal and Air Environment Made by Ceiling Cassette Type Cooling and Heating Unit in Classrooms (천장 카세트형 냉·난방기에 의해 형성되는 학교 교실의 실내 열환경 및 공기환경의 개선에 대한 연구)

  • Chang, Hyun-Jae;Lee, Ha-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.141-148
    • /
    • 2012
  • Ceiling cassette type air conditioner has been a main stream as a heating/cooling system recently in school, Korea. In this study, indoor thermal environments made by ceiling cassette type air conditioner were investigated by CFD simulation. Concentrations of $CO_2$ were investigated by a field measurement. Indoor thermal environment with the velocity inlet angle of $45^{\circ}$ from the ceiling in heating season was very ununiform so that thermal area was divided into two parts those the one is window side which is cold, and the other is corridor side which is hot. In cooling season under the same condition, there are areas too hot or too cold. If the velocity inlet angle is set in $30^{\circ}$ from the ceiling, indoor thermal environments was improved greatly in cooling season and heating season, too. Also, from the field measurement of $CO_2$ concentrations, it was suggested to install ventilators with proper air volume considered the number of class students.

Key Recovery Algorithm for Randomly-Decayed AES Key Bits (랜덤하게 변형된 AES 키 비트열에 대한 키 복구 알고리즘)

  • Baek, Yoo-Jin
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.26 no.2
    • /
    • pp.327-334
    • /
    • 2016
  • Contrary to the common belief, DRAM which is used for the main memory of various computing devices retains its content even though it is powered-off. Especially, the data-retaining time can increase if DRAM is cooled down. The Cold Boot Attack, a kind of side-channel attacks, tries to recover the sensitive information such as the cryptographic key from the powered-off DRAM. This paper proposes a new algorithm which recovers the AES key under the symmetric-decay cold-boot-attack model. In particular, the proposed algorithm uses the strategy of reducing the size of the candidate key space by testing the randomness of the extracted AES key bit stream.