• Title/Summary/Keyword: streak

Search Result 160, Processing Time 0.021 seconds

F-Center Excitation Energy Transfer to CN$^-$ vibrational Levels in CsCl

  • Jang, Du-Jeon
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1990.07a
    • /
    • pp.94-100
    • /
    • 1990
  • The rapid quenching dynamics of the F-center excitation by CN- defects in CsCl crystals were investigated by monitoring the ground state bleach recovery kinetics of F-centers, using a picosecond streak camera absorption spectrometer. The F-centers in CN- doped quenched samples show two bleach recovery components. Optical aggregation converts the slow component to the fast component. The slow one is due to the normal relaxation of the F*-centers as found in CN_ free crystals. The fast one is due to the energy transfer of the F-center electronic excitation to the vibrational energy levels of CN_ molecualr defects. The energy transfer occurs only in the F-center-CN_ defect pairs, FH(CN_)-centers.

  • PDF

The Investigation of Diesel Spray Combustion in DME HCCI Combustion (DME 예혼합 자기착화 연소중의 디젤분무연소에 관한 연구)

  • Lim, Ock-Taeck
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.4
    • /
    • pp.241-248
    • /
    • 2008
  • The purpose of the research is to investigate of diesel spray combustion for simultaneously reduction way of NOx and PM. The diesel injection were done into intermediates that are generated by very lean DME HCCI combustion using a RCM. The concentration of intermediate could not be directly measured, so we estimated it by CHEMKIN calculation. Two dimensional spontaneous luminescence images which are created by chemical species reaction at low temperature reaction (LTR) and high temperature reaction (HTR) are captured by using a framing streak camera. Also, combustion events were observed by high-speed direct photography. The ignition and combustion events were analyzed by pressure profiles and the KL values and flame temperatures were analyzed by the two-color method.

A Study on the analysis of in-cylinder flow fields using PTV (PTV를 이용한 실린더내 유동장 해석에 관한 연구)

  • Jeong, Hwan-Su;Choi, Su-Jin;Jeon, Chung-Hwan;Chang, Young-June
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.692-697
    • /
    • 2000
  • In Particle Tracking Velocimetry, the analysis of double-exposed photographic plate can be carried out either by means of Young's fringe analysis or by a digital image processing technique. In this study, we used digital image processing to two images in one frame far analyzing in-cylinder flow fields, and compared PTV with PSV(Particle Streak Velocimetry). Additionally, this technique was verified by two different calibration method. One is interpolation by invert distance, the other is interpolation by area ratio. Finally, the results between two interpolation methods were similar in whole flow fields.

  • PDF

A Study on a Searching, Extraction and Approximation-Synthesis of Transition Segment in Continuous Speech (연속음성에서 천이구간의 탐색, 추출, 근사합성에 관한 연구)

  • Lee, Si-U
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.4
    • /
    • pp.1299-1304
    • /
    • 2000
  • In a speed coding system using excitation source of voiced and unvoiced, it would be involved a distortion of speech quality in case coexist with a voiced and an unvoiced consonants in a frame. So, I propose TSIUVC(Transition Segment Including UnVoiced Consonant) searching, extraction ad approximation-synthesis method in order to uncoexistent with a voiced and unvoiced consonants in a frame. This method based on a zerocrossing rate and pitch detector using FIR-STREAK Digital Filter. As a result, the extraction rates of TSIUVC are 84.8% (plosive), 94.9%(fricative), 92.3%(affricative) in female voice, and 88%(plosive), 94.9%(fricative), 92.3%(affricative) in male voice respectively, Also, I obain a high quality approximation-synthesis waveforms within TSIUVC by using frequency information of 0.547kHz below and 2.813kHz above. This method has the capability of being applied to speech coding of low bit rate, speech analysis and speech synthesis.

  • PDF

Response of Spatially Developing Turbulent Boundary Layer to Spanwise Oscillating Electromagnetic Force (횡 방향 진동하는 전자기력에 대한 공간 발달하는 난류 경계층의 반응)

  • Lee, Joung-Ho;Sung, Hyung Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.11 s.242
    • /
    • pp.1189-1198
    • /
    • 2005
  • Direct numerical simulations were performed to investigate the physics of a spatially developing turbulent boundary layer flow subjected to spanwise oscillating electromagnetic forces in the near wall region. A fully implicit fractional step method was employed to simulate the flow. The mean flow properties and the Reynolds stresses were obtained to analyze the near-wall turbulent structure. It is found that skin friction and turbulent kinetic energy can be reduced by the electromagnetic forces. The decrease in production is responsible fur the reduction of turbulent kinetic energy. Instantaneous flow visualization techniques were used to observe the response of streamwise vortices and streak structures to spanwise oscillating forces. The near-wall vortical structures are affected by spanwise oscillating electromagnetic forces. Following the stopping of the electromagnetic force, the flow eventually relaxes back to a two-dimensional equilibrium boundary layer.

Diagnostic Instruments of PLS-II

  • Kim, Chang-Beom;Kim, Do-Tae;Choe, Jae-Yeong;Lee, Heung-Su;Park, Eung-Su;Sin, Seung-Hwan;Hwang, Jeong-Yeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.527-527
    • /
    • 2012
  • In the Pohang Light Source (PLS), a major upgrade (PLS-II) of existing machine had been performed in last 3 years. Big improvements in beam parameters are expected from this major upgrade and various diagnostic instruments were installed to measure them. These include beam position monitor, beam current monitor, tune monitor, scraper, beam loss monitor, photon beam monitor, beam size monitor, streak camera, and so on. In this work, we would like to briefly introduce diagnostic instruments of the PLS-II and present measurement results in the commissioning process of the PLS-II.

  • PDF

Temperature Field Measurement of Ventilation Flow in a Vehicle Interior (TLC와 컬러화상처리를 이용한 자동차 실내 환기유동의 온도장 측정)

  • 윤정환;이상준;김기원
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.1
    • /
    • pp.120-128
    • /
    • 1997
  • The variations of the temperature field in a passenger compartment were measured by using a HSI true color image processing system and TLC(Thermochromic Liquid Crystal) solution. This temperature measurement technique was proved to be useful for analyzing the ventilation flow. The flow field in the passenger compartment was visualized using a particle streak method with pulsed laser light sheet. The temperature field and flow field in the passenger copartment were affected significantly by the ventilation mode. The panel-vent mode heating had shorter elapse time to reach a uniform temperature than the foot-vent mode under the same ventilation condition and nonuniformity inside the passenger compartment could be minimized effectively by using the bilevel heating mode. The temperature increase rate in the rear passenger compartment was iower than the front compartment, especially in the vicinity of the rear seat occupants' knee level.

  • PDF

A Study on Wake Flow behind a pair of Circular Cylinders with gap (간격을 갖는 원주열의 후류특성에 관한 연구)

  • 김준호;최민선;조대환;이경우
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.135-139
    • /
    • 2001
  • This experimental study investigates the wake flow behind a pair of cylinders displaced normal to a free stream. In this experiment, the principal aim is to investigate the transition mechanism of the large vortex generating process in the wake having unique vortex shedding pattern. associated with the gap difference between the cylinders. The detailed visualization is carried out using the PIV measurement. The transition mechanism of the large generating vortex is clarified by showing the streak lines. the vorticity and the statistical fluctuating velocity distributions.

  • PDF

Development of a Pre/Post Processor Program for the Analysis of the Passenger Flow based on Discrete Element Method(DEM) (DEM에 기초한 여객유동 해석을 위한 전/후처리 프로그램 개발)

  • Kim, Chi-Gyeom;Won, Chan-Shik;Hur, Nahm-Keon;Nam, Seong-Won
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.475-480
    • /
    • 2008
  • A pre/post processor program based GUI(Graphic User Interface) by using the MFC and OpenGL library in the Windows OS have been developed for the analysis of the passenger flow. Using this program, users are able to generate and modify the meshes of multi-storied subway station, set all the parameters for the solver, and obtain the results of the simulation such as transient passenger motions and passenger streak lines in 3-dimensional graphic view.

  • PDF

The Antimicrobial Activities of some 1,4-Naphthalenediones (IV)

  • Ryu, Chung-Kyu;Kim, Dong-Hyun;Kim, Hee-Joeng;Chung, Sae-Young
    • Archives of Pharmacal Research
    • /
    • v.16 no.4
    • /
    • pp.327-330
    • /
    • 1993
  • A series of 2-chloro and 2-bromo-3-(substituted)-1, 4-naphthalenedione derivatives (1-25) were tested for antifungal and antibacterial activities in vitro against Candida albicans 10231 aand Local, Aspergillus niger KCTC 1231, Tricophyton mentagrophytes KCTC 6085, Fusarium oxysporium KTCC 6501, Bacillus subtilis ATCC 6633, Pseudomonas arruginosa NCTC 10490, Staphylococcus aureus ATCC 6358p, Escherichia coli NIHJ and Acinetobacter baumanii Local. The MiC values were determined by twofold afar diution/streak method. Among thee derivatives, 1, 9, 20, 21, 23 and 25 showed more potent antifungal activities than fluconazole. 20 and 23 completely inhibited the gorwth of fungi, such as Candida albicans, Aspegillus niger, Ticophyton mentagrophytes and fusarium oxysporium, at $3.2\;\mu{g/ml}$. Also some derivatives had the antibacterial activities against Gram-positive bacteria.

  • PDF