• 제목/요약/키워드: strain measurement

검색결과 1,092건 처리시간 0.027초

풍력발전기 주축 및 날개 부하 측정시스템의 보정 및 불확실성 해석 (A Calibration and Uncertainty Analysis on the Load Monitoring System for a Low Speed Shaft and Rotor Blade of a Wind Turbine)

  • 박무열;유능수;남윤수
    • 대한기계학회논문집A
    • /
    • 제30권5호
    • /
    • pp.560-567
    • /
    • 2006
  • The exact load measurements for the mechanical parts of a wind turbine are important step both fur the evaluation of a specific wind turbine design and for a certification process. A common method for a mechanical load measurement is using a strain gauge sensing. Two main problems ought to be answered in order for this method to be applied to the wind turbine project. These are strain gauge calibration and non-contact signal transmission from the strain gauge output to a load monitoring system. This paper suggests reliable solutions fer these two problems. A Bluetooth, a short range wireless data communication technology, is used to solve the second problem. The first one, the strain gauge calibration methodology for a load measurement in a wind turbine application, is fully explained in this paper. Various mechanical loadings for a strain gauge calibration in a wind turbine load measurement are introduced and analyzed. Initial experimental results which are obtained from a 1 kW small size wind turbine are analyzed, and the uncertainty problem in estimating mechanical loads using a calibration matrix is fully covered in this paper.

기계적/전기적 측정 센서를 이용한 Kogas Pilot LNG 저장탱크 멤브레인 변형 거동 측정(II) (The Measurement of Membrane Deformation Behavior in Kogas Pilot LNG Storage Tank by the use of Mechanical/Electrical Sensor (II))

  • 김영균;홍성호;오병택;윤인수;김지훈;김석순
    • 한국가스학회:학술대회논문집
    • /
    • 한국가스학회 2003년도 추계학술발표회 논문집
    • /
    • pp.85-90
    • /
    • 2003
  • Korea Gas Corp. has developed the design technology of the LNG storage tank. The membrane to be applied inside of LNG storage tank is provided with corrugations to absorb thermal contraction and expansion caused by LNG temperature. We constructed strain measurement system by using strain gage. In this paper, some problems which should be considered when measuring strain at $-162^{\circ}C$, are discussed by presenting test results on the characteristics of strain gages, Temperature sensor, adhesive and lead wire. And presenting the procedure of the constructing strain measurement system.

  • PDF

레이저 스페클과 디지털 화상관련법을 이용한 변위 측정방법의 평가 (Evaluation of Displacement Measurement Technique Using Laser Speckle and Digital Image Correlation Method)

  • 강기주;이정현;전문창
    • 한국정밀공학회지
    • /
    • 제20권6호
    • /
    • pp.47-54
    • /
    • 2003
  • As a tool for strain measurement to work with screw driven or hydraulic material test systems, in which mechanical vibration is inherent, SSDG (Speckle Strain/Displacement Gage), ESP (Electronic Speckle Photography) and its 3-dimension version SDSP are evaluated for the theory and practical appliance. Through tension test of steel strips, their validity and shortcomings are examined. As the results, it has been shown that, although SSDG and ESP provide direct measurement of in-plane strain in one direction, they are so sensitive to the out-plane displacement. On the other hand, SDSP which is aided with DIC (Digital Image Correlation) technique to trace the movement of the speckles provides not only in-plane 2-dimensional displacement field, but also out-of-plane displacement simultaneously. However, because the DIC is time-consuming, not automated yet and it needs post-processing to evaluate strain from the displacement field, SDSP appears to be not adequate as a real time sensor.

비전을 이용한 중.대형 판재성형 제품의 곡면 변형률 측정 알고리듬 개발 (Development of an Algorithm for the Vision-Based Surface-Strain Measurment of Large Stamped Parts)

  • 김형종
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1999년도 춘계학술대회논문집
    • /
    • pp.269-272
    • /
    • 1999
  • It is still hard to measure the strain distribution over entire surface of a medium or large-size stamped part even by using an automated strain measurement system. Several methods which enable to enlarge the measurement range without losing accuracy and precision are suggested in this study, The superposition of images having different high-lightened or damaged part each other results in an enhanced image. A new method for constructing the element connectivity from a line-thinned image makes it possible to identify up to 1,000 elements. And the geometry assembling algorithm is proved very efficient in which the whole area to be measured is divided into several parts ; the coordinate transformation between every two adjacent parts is obtained from the concept of the least square error ; and the 3-D shape or strain distribution over the whole surface is assembled,

  • PDF

지역 평량이 지역 변형률에 미치는 영향 (The Effect of Local Basis Weight on Local Strain)

  • 남원석;백기현
    • 펄프종이기술
    • /
    • 제31권3호
    • /
    • pp.105-109
    • /
    • 1999
  • The purpose of this experiment was to see the effect of local basis weight on the local strain during changing moisture content in handsheets. The averaged strain value of the whole size of paper sheet did not give more valuable information to explain non uniform deformation in the paper sheet. The combination of intact strain measurement system KISA (Linear Image Strain Analysis) and local basis weight measurement method using a scanner made it possible to compare local basis weight with local strain to explain moisture induced paper deformation . Usually higher basis weight local area showed higher moisture induced local strain. However, the hygro-induced strain values were highly affected by the behavior of neighbor local areas. Well distributed local basis weight paper would give more uniform local strains than those of non-uniformed local basis weight paper.

  • PDF

평면변형장출실험을 이용한 스탬핑 성형성 평가 (A plane strain punch stretching test for evaluating stamping formability)

  • 김영석;남재복
    • 오토저널
    • /
    • 제15권2호
    • /
    • pp.121-129
    • /
    • 1993
  • Plane strain punch stretching test (PSST) was developed to evaluate stamping formability of sheet materials. In this test, the rectangular specimen of sheet material is uniformly stretched up to fracture by raising a specially designed punch to certainly assure plane strain stretching deformation along the longitudinal direction of the specimen. The stamping formability was evaluated by limit punch height(LPH) in plane strain punch stretching test compared to limit dome height(LDH) in hemispherical punch stretching test. LPH-value in PSST well ranks the stamping formability of various material and correlates with press performance. Moreover by using ultrasonic thickness gauge the plane strain intercept-limit plane strain(FLCo)-in forming limit curve can be accurately determined from thickness measurement around the fracture area. The FLCo derived from thickness measurement well correlates with the results from circle grid analysis for the deformed circle grid marked on the surface of the specimen.

  • PDF

온도 보상형 Double FBG센서의 제작과 기계적 변형률 측정시험 (Fabrication of a Temperature-Compensating FBB Sensor for Measurement of Mechanical Strain)

  • 정달우;권일범;최낙삼
    • 비파괴검사학회지
    • /
    • 제25권5호
    • /
    • pp.356-361
    • /
    • 2005
  • 본 연구에서 개발한 온도 보상형 double FBG 센서는 서로 다른 브래그 파장을 갖는 두개의 FBG 센서를 직렬로 연결하여 다양한 열적 조건하에서 구조물의 기계적 변형률만을 실시간으로 측정하기 위한 센서이다. 이 센서를 알루미늄 보에 접착하여 다양한 온도 조건에서 변형률 측정 실험을 수행하고, 결과 값을 전기 저항식 변형률 게이지의 결과 값과 비교하였다. 본 연구에서 제작한 온도보상형 double FBG 센서는 온도의 변화에 영향을 받지 않고 기계 변형률 측정을 잘 수행하였다.

콘크리트 포장(鋪裝)의 초기계측(初期計測)을 통한 초기거동(初期擧動) 특성분석(特性分析) (Analysis of Early Behavior of Concrete Pavement with Initial Measurements)

  • 정원경;김동호;권혁찬;윤경구
    • 산업기술연구
    • /
    • 제23권A호
    • /
    • pp.165-173
    • /
    • 2003
  • The purpose of this paper is to analysis of initial behavior of concrete pavement with initial measurement strain gauge for concrete pavement at field, and to investigate the field test results for field applicability testing. The early-age behaviors of concrete pavement slabs were measured using the strain gauges. From the slab depths and positions, the outputs from each gauges were recorded at initial curing period. The initial measurement of concrete pavement and check of crack at the joint were performed, the results could be summarized as follows. From the results of concrete strength, compressive strength and flexural strength were showed $271kgf/cm^2$, $43kgf/cm^2$ respectively. From the tests of early-age strain measurement, it was found that the strain varied at the maximum value of $150{\mu}{\varepsilon}$ and early behavior of concrete slab was showed a tensile strain. However, for long-term was showed a compressive strain due to dry-shrinkage.

  • PDF

이미지 상관법을 이용한 휨 변형률 측정에 관한 연구 (Study on the Measurement of Flexural Strain Using the Digital Image Correlation in the Three-Point Bending Test)

  • 최인영;강영준;홍경민;고광수;이학성
    • 한국생산제조학회지
    • /
    • 제23권5호
    • /
    • pp.498-504
    • /
    • 2014
  • Displacements and strains are very important for material evaluation as critical factors to a machine's life cycle and safety. Typically, the strain gauge has been employed to measure displacement and strain. However, this contact-type measurement method has disadvantages that are not quantified under the test conditions of a specific object shape, surface roughness, and temperature. In this paper, the measurement of deflection and flexural strain due to the three-point bending test is presented, employing Digital Image Correlation (DIC) methods. In order to ensure measurement reliability, DIC and universal test machine methods were compared by measuring the deflections and flexural strains developed by such bending tests.

ESPI에 의한 원공판의 2차원 면내변위 측정에 관한 연구 (A study on the measurement of two-dimensional in-plane displacements of the plate with a circular hole by ESPI method)

  • 김경석;최형철;양승필;김형수;홍명석;정운관
    • 한국정밀공학회지
    • /
    • 제11권5호
    • /
    • pp.161-170
    • /
    • 1994
  • This paper presents the performance and problems in analysis method and testing system of Electronic Speckle Pattern Interfermetry(ESPI) method, in measuring two-dimensional in- plane displacement. The analysis result of measurement by ESPI is quite comparable to that of measurement by strain gauge method. This implieds that the method of ESPI is a very effective tool in non-contact two-dimensional in-plane strain analysis. But there is a controversial point, measurement error. This error is discussed to be affected not by ESPI method itself, but by its analysis scheme of the interference fringe, where the first-order interpolation has been applied to the points of strain measured. Further development of advanced first-order interpolation method is being undertaken for the more precise in-plane strain measurement.

  • PDF