Assessment of FEMA356 nonlinear static procedure and modal pushover analysis for seismic evaluation of buildings

  • Khoshnoud, Hamid Reza;Marsono, Kadir
    • Structural Engineering and Mechanics
    • /
    • 제41권2호
    • /
    • pp.243-262
    • /
    • 2012
  • Nonlinear static analysis as an essential part of performance based design is now widely used especially at design offices because of its simplicity and ability to predict seismic demands on inelastic response of buildings. Since the accuracy of nonlinear static procedures (NSP) to predict seismic demands of buildings affects directly on the entire performance based design procedure, therefore lots of research has been performed on the area of evaluation of these procedures. In this paper, one of the popular NSP, FEMA356, is evaluated and compared with modal pushover analysis. The ability of these procedures to simulate seismic demands in a set of reinforced concrete (RC) buildings is explored with two level of base acceleration through a comparison with benchmark results determined from a set of nonlinear time history analyses. According to the results of this study, the modal pushover analysis procedure estimates seismic demands of buildings like inter story drifts and hinges plastic rotations more accurate than FEMA356 procedure.

Seismic behavior of non-seismically designed reinforced concrete frame structure

  • Nguyen, Xuan-Huy;Nguyen, Huy Cuong
    • Earthquakes and Structures
    • /
    • 제11권2호
    • /
    • pp.281-295
    • /
    • 2016
  • This paper presents a study on a non-seismically designed reinforced concrete (RC) frame structure. The structure was a existing three-story office building constructed according to the 1990s practice in Vietnam. The 1/3 scaled down versions of structure was tested on a shake table to investigate the seismic performance of this type of construction. It was found that the inter-story drift and the overall behavior of structure meet the requirements of the actual seismic design codes. Then, nonlinear time history analyses are carried out using the fiber beam- column elements. The comparison between the experimental and simulation results shows the performance of the time history analysis models.

Response of structures to seismic sequences corresponding to Mexican soft soils

  • Diaz-Martinez, Gerardo;Ruiz-Garcia, Jorge;Teran-Gilmore, Amador
    • Earthquakes and Structures
    • /
    • 제7권6호
    • /
    • pp.1241-1258
    • /
    • 2014
  • This is paper presents the results of an analytical study aimed at evaluating the effect of narrow-banded mainshock/aftershock seismic sequences on the response of structures built on very soft soil sites. Due to the scarce availability of recorded seismic sequences in accelerographic stations located in the lake-bed of Mexico City, artificial narrow-banded sequences were employed. In the first part of this study, a parametric investigation was carried out to identify the mainshock/aftershock ground motion features that have detrimental effects in the seismic performance of equivalent single-degree-of-freedom systems representative of framed-buildings that house standard and essential facilities. In the second part of this work, the seismic response of two (8- and 18-story) steel-moment resisting frames that house essential facilities is examined. It is concluded that buildings with fundamental periods of vibration longer than the dominant period of the mainshock can experience a significant increment in their inter-story drift demands due to the occurrence of an aftershock.

Reinforced concrete core-walls connected by a bridge with buckling restrained braces subjected to seismic loads

  • Beiraghi, Hamid
    • Earthquakes and Structures
    • /
    • 제15권2호
    • /
    • pp.203-214
    • /
    • 2018
  • Deflection control in tall buildings is a challenging issue. Connecting of the towers is an interesting idea for architects as well as structural engineers. In this paper, two reinforced concrete core-wall towers are connected by a truss bridge with buckling restrained braces. The buildings are 40 and 60-story. The effect of the location of the bridge is investigated. Response spectrum analysis of the linear models is used to obtain the design demands and the systems are designed according to the reliable codes. Then, nonlinear time history analysis at maximum considered earthquake is performed to assess the seismic responses of the systems subjected to far-field and near-field record sets. Fiber elements are used for the reinforced concrete walls. On average, the inter-story drift ratio demand will be minimized when the bridge is approximately located at a height equal to 0.825 times the total height of the building. Besides, because of whipping effects, maximum roof acceleration demand is approximately two times the peak ground acceleration. Plasticity extends near the base and also in major areas of the walls subjected to the seismic loads.

P-$\Delta$ 효과를 고려한 철골 구조물의 비선형 동적거동 평가 (Evaluation of Nonlinear Dynamic Behavior for Steel Moment Frame Structures Considering P-$\Delta$ Effects)

  • 최원호;이주완;이동근
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2001
    • /
    • pp.235-242
    • /
    • 2001
  • Inelastic seismic response of steel moment frame structures, which are usually quite gravity load and subject to large displacement under severe earthquake, may be severly influenced by the structure P-Δ effects. The P-Δ effect may have an important impact on the dynamic behavior of the structure in the nonlinear seismic analysis. In multi degree of freedom systems P-Δ effects may significantly affect only a subset of stories or a single story alone. Therefore, a story drift amplification of structure is happened by P-Δeffects and such nonlinear dynamic behaviors are very difficult to evaluate in the structures. In this study, two systems having different design methods of steel moment frame structures are investigated to evaluate the P-Δ effects due to gravity load. The plastic hinge formations, maximum rotational ductility demands, and energy distribution will be compared and evaluated following whether the P-Δ effects are considered or not. And design methods are proposed for the prevention of the instability of structures which due to the P-Δ effects.

  • PDF

A Study on a Repair Technique for a Reinforced Concrete Frame Subjected to Seismic Damage Using Prestressing Cable Bracing

  • Lee, Jin Ho;EI-Ganzory, Hisham
    • Architectural research
    • /
    • 제3권1호
    • /
    • pp.53-60
    • /
    • 2001
  • The proposed building upgrading technique employs prestressing cables to function as bracing to improve the seismic performance during future events. A four-story reinforced concrete moment resisting frame damaged from an ultimate limit state earthquake is assessed and upgraded using the proposed technique. Both existing and upgraded buildings are evaluated in regard of seismic performance parameters performing static lateral load to collapse analysis and dynamic nonlinear time history analysis as well. To obtain realistic comparison of seismic performance between existing and upgraded frames, each frame is subjected to its critical ground motion that has strength demand exceeding the building strength supply. Furthermore, reliability of static lateral load to collapse analysis as a substitute to time history analysis is evaluated. The results reveal that the proposed upgrading technique improves the stiffness distribution compared to the ideal distribution that gives equal inter-story drift. As a result, the upgraded building retains more stories that contribute to energy dissipation. The overall behavior of upgraded building beyond yield is also enhanced due to the gradual change of building stiffness as the lateral load increases.

  • PDF

20층 비선형 벤치마크 빌딩에 대한 MR 유체 감쇠기의 최적위치 결정 (Optimal placement of MR dampers for 20-story nonlinear benchmark building)

  • 장종우;조상원;윤우현;이인원
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.153-160
    • /
    • 2003
  • The objective of optimal placement of dampers for a structure is to maximize the effective-ness of the vibration control with the same number of dampers. While many optimal placement methods of linear viscous dampers have been proposed and used, there are only a few methods for MR dampers. Here some optimal location indices for M dampers are proposed, which are similar to those for linear viscous dampers and show how large the structural responses on each floor are. Every time an additional MR damper is implemented, the optimal location index on each floor is measured, and then the next damper is installed on the floor with the maximum location index. In these sequential procedures, the peak interstory drift, the peak interstory velocity and the absolute acceleration of each floor are selected as the optimal location indeices. Four different earthquakes with various scales are loaded to the 20-story nonlinear benchmark building model (Otori et al. 2000, 2002). Passive On/on algorithms are used in order to represent the control algorithm of M dampers.

  • PDF

Seismic progressive collapse assessment of 3-story RC moment resisting buildings with different levels of eccentricity in plan

  • Karimiyan, Somayyeh;Moghadam, Abdolreza S.;Vetr, Mohammad G.
    • Earthquakes and Structures
    • /
    • 제5권3호
    • /
    • pp.277-296
    • /
    • 2013
  • Margin of safety against potential of progressive collapse is among important features of a structural system. Often eccentricity in plan of a building causes concentration of damage, thus adversely affects its progressive collapse safety margin. In this paper the progressive collapse of symmetric and asymmetric 3-story reinforced concrete ordinary moment resisting frame buildings subjected to the earthquake ground motions are studied. The asymmetric buildings have 5%, 15% and 25% mass eccentricity. The distribution of the damage and spread of the collapse is investigated using nonlinear time history analyses. Results show that potential of the progressive collapse at both stiff and flexible edges of the buildings increases with increase in the level of asymmetry in buildings. It is also demonstrated that "drift" as a more easily available global response parameter is a good measure of the potential of progressive collapse rather than much difficult-to-calculate local response parameter of "number of collapse plastic hinges".

기존 골조의 내진성능 향상을 위한 철근콘크리트 현장타설 끼움벽의 보강성능 평가 (Evaluation on Seismic Performance of Existing Frame retrofitted with RC CIP Infill Walls)

  • 김선우;윤현도;김윤수;지상규
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.53-56
    • /
    • 2008
  • A reinforced concrete (RC) cast-in-place (CIP) infill wall retrofitting method may provide an improved seismic performance and economical efficiency for the non-ductile rahmen structures. In this study, four one story-one bay non-ductile frame were constructed and retrofitted with CIP infill wall to evaluate seismic performance of CIP infill wall-frame. From the test results, infill wall-frame exhibited a marked increase in shear strength compared to non-ductile RC frame specimen. But the ductility and story-drift at maximum load were decreased when shear strength of infill wall larger than that of existing RC frame. Therefore, it is confirmed that adequate reinforcement detail is required to assure sufficient seismic performance.

  • PDF

확률적 지진 응답을 이용한 점탄성 감쇠기의 적정설치 위치선정에 관한 연구 (Decision of the Proper Damper Locations Using Stochastic Seismic Responses)

  • 김진구
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1999년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall
    • /
    • pp.147-154
    • /
    • 1999
  • This paper presents a procedure for the frequency-domain analysis of a non-proportionally damped structure subjected to stationary seismic loads and for the finding of proper damper locations through simple analysis procedure without iteration. The shear areas of the dampers are decided in proportion to the magnitude of the components of the primary mode shape vector and to the root mean square values of the story drifts, The root-mean-squear responses are obtained using a power spectral density function for the ground acceleration. the results are compared with those obtained from damper placement decided in sequency based on the maximum story drift. According to the results the reliability of the proposed method turns out to be satisfactory compared to the methods which required iteration.

  • PDF