• 제목/요약/키워드: stormwater

검색결과 350건 처리시간 0.023초

철로 역사 건설에 따른 강우 유출수내 비점오염물질의 동적 EMCs 및 처리방안 연구 (Dynamic EMCs and Optimum Treatment Criteria for Stormwater Runoff of a Railway Station)

  • 임경호;김기동;이병식;김이형
    • 한국철도학회논문집
    • /
    • 제8권4호
    • /
    • pp.308-313
    • /
    • 2005
  • In order to successfully propel the stormwater management program, administration plan of stormwater management is enacted in Spring, 2005. Hereafter, in a newly developing area such as a railway station, the best management practices should be established to control the nonpoint pollutant. Construction of a railway station means the increasing of imperviousness rate and lots of nonpoint pollutant emissions during rainfall. Therefore this research was performed to determine the pollutant EMC and to suggest the possible best management practice for treating nonpoint pollutants from a railway station. The $95\%$ confidence intervals of pollutant EMC were ranged to 69.4-115.2mg/L for TSS, 132.7-190.4mg/L for COD, 5.4-15.1ug/L for Oil & Grease, 4.9-12.4mg/L for TKN and 568.4-620.1ug/L for TP. The first flush criteria was ranged to 5-10mm accumulated rainfall using dynamic EMCs, Also laboratory reactor testing was performed. It shows that Zeolite media is useful for removing the washed-off pollutants from a railway station, especially for metal ions.

Effect of Stormwater Runoff on Combined Sewer Overflows in Korea

  • Kim, Lee-Hyung;Kim, Il-Kyu;Lee, Young-Sin;Lim, Kyeong-Ho
    • 한국방재학회 논문집
    • /
    • 제7권4호
    • /
    • pp.107-113
    • /
    • 2007
  • The Kuem-River, one of the largest rivers in Korea, is the primary water source for more than 4 million people in Kongju city and surrounding area. To study the effect of stormwater runoff to CSOs, twelve monitoring sites were selected in two large cities (City of Kongju and City of Buyeo) near the Kuem-River. Monitoring was reformed by collecting grab samples, measuring flow rates during dry and wet seasons during over two rainy seasons. Generally the flow rate of wastewater in combined sewers was rapidly decreased after 23:00 P.M. and gradually increased from 06:30 A.M. in all sites during the dry season. The concentrations of pollutant increase approximately 5 to 7 fold for TSS and 1.5 to 2.5 fold for BOD during the rainy season. Monitoring and statistical analysis show that the groundwater contributes on sewage volume increase (average 25-45% more) during dry periods and the stormwater runoff contributes approximately 51-72% increase during rainy periods. Generally the concentrations of combined sewage were more polluted during the first flush period than after the first flush during a storm event.

실험실 조건에서 레인가든의 도시 비점오염물질 제거효과 (Effects of Rain Gardens on Removal of Urban Non-point Source Pollutants under Experimental Conditions)

  • 김창수;성기준
    • 한국물환경학회지
    • /
    • 제28권5호
    • /
    • pp.676-685
    • /
    • 2012
  • As impermeable layer continues to increase with the urbanization process, direct input of nonpoint source pollutants into water bodies via stormwater has caused serious effects on the aquatic ecosystem. Potential applications of rain gardens are increasing not only as best management practices (BMP) for reducing the level of nonpoint source pollutants but also as an ecological engineering alternative for low impact development (LID). In this study, remediation performance of various planting types, such as a mixed planting system with shrubs and herbaceous plants, was assessed quantitatively to effectively manage stormwater and increase landscape applicability. The mixed planting system with Rhododendron lateritium and Zoysia japonica showed the highest removal performance of $76.9{\pm}7.6%$ and $58.4{\pm}5.0%$ for total nitrogen and $89.9{\pm}7.9%$ and $82.4{\pm}5.2%$ for total phosphorus at rainfall intensities of 2.5 mm/h and 5.0 mm/h, respectively. The mixed planting system also showed the highest removal performance for heavy metals. The results suggest that a rain garden with the mixed planting system has high potential applicability as a natural reduction system for nonpoint source pollutants in order to manage stormwater with low concentrations of pollutants and will increase water recycling in urban areas.

강우유출수 관리시설의 설계를 위한 강우사상 특성 분석 (Analysis of Storm Event Characteristics for Stormwater Best Management Practices Design)

  • 김학관;지현서;장선숙
    • 한국농공학회논문집
    • /
    • 제59권6호
    • /
    • pp.73-80
    • /
    • 2017
  • The objective of this study is to investigate whether the daily rainfall depth derived from daily data represents the event rainfall depth derived from hourly data. For analysis, the 85th, 90th, and 95th percentile daily rainfall depths were first computed using daily rainfall data (1986~2015) collected at 63 weather stations. In addition, the storm event was separated by the interevent time definition (IETD) of 6, 12, 18, and 24 hr using hourly rainfall data. Based on the separated storm events, the 85th, 90th, and 95th percentile event rainfall depths were calculated and compared with the using hourly rainfall data with the 85th, 90th, and 95th percentile daily rainfall depths. The event rainfall depths computed using the IETD were greater than the daily rainfall depths. The difference between the event rainfall depth and the daily rainfall depth affects the design and size of the facility for controlling the stormwater. Therefore, the designer and policy decision-maker in designing the stormwater best management practices need to take into account the difference generated by the difference of the used rainfall data and the selected IETD.

우리나라 도시배수분구에서의 SUSTAIN 적용가능성 연구 (A Study on Applicability of SUSTAIN in a Korean Urban Catchment)

  • 이정훈;박윤경;신현석;김정숙;김상단
    • 한국물환경학회지
    • /
    • 제29권6호
    • /
    • pp.730-738
    • /
    • 2013
  • In recent years, low impact development (LID) has emerged as an effective approach to control stormwater in an urban area, and watershed and stormwater managers need modeling tools to evaluate alternative plans for controlling stormwater. This study illustrates how to design and evaluate the effect of non-point pollutant management using SUSTAIN which is developed by USEPA. SUSTAIN can provide evaluating, selecting, and placing LID facilities in an urban catchment based on user-defined cost-effectiveness criteria. Also, this paper suggests a minimal methodology for estimating model parameters for modeling an ungauged urban catchment to reflect the situation of typical Korean urban interested catchments which are usually ungauged. In addition, the optimal length of various LID facilities and the optimal number of units in our test catchment are estimated.

Evaluation of urban pollutant washoff characteristics and treatment efficiency of a small constructed wetland

  • Reyes, Nash Jett DG.;Geronimo, Franz Kevin F.;Kim, Lee-Hyung
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2019년도 학술발표회
    • /
    • pp.412-412
    • /
    • 2019
  • Nature-based solutions (NBS) offer a wide variety of techniques that promote cost-efficient stormwater management practices. In particular, low impact development facilities utilize NBS principles to restore the ecosystem services in a highly-urbanized area. Despite the advancements in these technologies, several considerations should still be addressed to ensure optimum functionality and attainment of desired pollutant removal efficiency a LID facility. This study evaluated the mass flushing characteristics of pollutants in an urban catchment and the efficiency of a small constructed wetland (SCW) in treating urban stormwater runoff. 21 rainfall events from 2010 to 2018 were monitored to determine and quantify stormwater pollutants. The highest pollutant washoff was observed on rainfall depths ranging from 0.1mm to 10mm, whereas events with greater rainfall depths exhibited lower pollutant concentrations due to dilution effect. However, the SCW manifested lower pollutant-removal performance on rainfall depths exceeding 10mm due to the exceedance of the facility's design rainfall. This study is beneficial in assessing the dynamics of pollutant washoff and efficiency of LID facilities subjected under various external factors.

  • PDF

Factors affecting the infiltration rate and removal of suspended solids in gravel-filled stormwater management structures

  • Guerra, Heidi B.;Yuan, Qingke;Kim, Youngchul
    • Membrane and Water Treatment
    • /
    • 제10권1호
    • /
    • pp.67-74
    • /
    • 2019
  • Apparent changes in the natural hydrologic cycle causing more frequent floods in urban areas and surface water quality impairment have led stormwater management solutions towards the use of green and sustainable practices that aims to replicate pre-urbanization hydrology. Among the widely documented applications are infiltration techniques that temporarily store rainfall runoff while promoting evapotranspiration, groundwater recharge through infiltration, and diffuse pollutant reduction. In this study, a laboratory-scale infiltration device was built to be able to observe and determine the factors affecting flow variations and corresponding solids removal through a series of experiments employing semi-synthetic stormwater runoff. Results reveal that runoff and solids reduction is greatly influenced by the infiltration capability of the underlying soil which is also affected by rainfall intensity and the available depth for water storage. For gravel-filled structures, a depth of at least 1 m and subsoil infiltration rates of not more than 200 mm/h are suggested for optimum volume reduction and pollutant removal. Moreover, it was found that the length of the structure is more critical than the depth for applications in low infiltration soils. These findings provide a contribution to existing guidelines and current understanding in design and applicability of infiltration systems.

Estimation of stormwater interception ratio for evaluating LID facilities performance in Korea

  • Choi, Jeonghyeon;Lee, Okjeong;Lee, Jeonghoon;Kim, Sangdan
    • Membrane and Water Treatment
    • /
    • 제10권1호
    • /
    • pp.19-28
    • /
    • 2019
  • To minimize the impact of urbanization, accurate performance evaluation of Low Impact Development (LID) facilities is needed. In Korea, the method designed to evaluate large-scale non-point pollution reduction facilities is being applied to LID facilities. However, it has been pointed out that this method is not suitable for evaluating the performance of relatively small-scale installed LID facilities. In this study, a new design formula was proposed based on the ratio of LID facility area and contributing drainage area, for estimating the Stormwater Interception Ratio (SIR) for LID facilities. The SIR was estimated for bio-retentions, infiltration trenches and vegetative swales, which are typical LID facilities, under various conditions through long-term stormwater simulation using the LID module of EPA SWMM. Based on the results of these numerical experiments, the new SIR formula for each LID facility was derived. The sensitivity of the proposed SIR formula to local rainfall properties and design variables is analysed. In addition, the SIR formula was compared with the existing design formula, the Rainfall Interception Ratio (RIR).

경상남도 공공청사형 그린빗물인프라(GSI) 조성 체계 구축 (A study on the construction of the planning process Green Stormwater Infrastructure (GSI) in the public building in Gyeongsangnam-do)

  • 이효정;신현석
    • 한국수자원학회논문집
    • /
    • 제56권4호
    • /
    • pp.301-310
    • /
    • 2023
  • 환경부에서는 2013년부터 소규모 분산식 빗물 관리 방식인 '그린빗물인프라(Green Stormwater Infrastructure, GSI) 조성 사업'을 추진하여 설치비를 지원함에 따라 각 지자체의 GSI 조성 사업은 매년 증가하고 있다. 하지만 「저영향개발 사전협의제도」를 도입하고 있는 서울시를 제외하면, 각 지자체별 가이드라인, 추진체계 부존의 문제로 도입에 어려움을 겪고 있다. 이에 본 연구에서는 경상남도를 대상으로 공공청사의 적용 범위 및 우선 순위 설정, 시범 구역 GSI 적용 효과 검토를 수행하고 이를 통합한 추진체계 구축을 연구 결과로써 제안하고자 한다.

강우시 포도밭에 대한 초기세척효과 분석 (Analysis of First Flushing Effects for the Vineyard Storm Runoff)

  • 윤영삼;권헌각;이재운;유재정;이재관
    • 한국환경과학회지
    • /
    • 제20권8호
    • /
    • pp.977-986
    • /
    • 2011
  • This study analyzed the characteristics of stormwater runoff in the orchard areas and quantitatively estimated effluence of nonpoint source pollutants for the volume of runoff. Two target areas under vine cultivation were each $2,000m^2$ and $1,800m^2$, located in Gyeongju City. Since grape was the only crop on the target area, the characteristics of stormwater runoff at vineyard could be evaluated independently. A total of 51 rainfall events in the vineyard area during two years(2008-2009) was surveyed, and 19 of them became stormwater runoff, with rainfall ranging 16.5 - 79.7 mm and antecedent dry period of 1-13 days. The pollutant runoff loads by volume of stormwater runoff showed BOD ranging 19.5 - 45.3% in 30% of runoff volume. The average pollution discharge rate was 32.4%, indicating small first flush effect of BOD. The range of SS concentrations was 5 - 52.0% in 10% of runoff volume, showing the average 28.7% of discharge rate, about 3 times more than rainfall effluent. TOC and TN appeared to be similar to the results of BOD, the average discharge rate of 30.9% and 30.6% for TOC and TN, respectively, for 30% of stormwater runoff volume. Average discharge rate of COD and TP in the same runoff volume was 35.1% and 36%, respectively, showing comparatively high discharge ratio. As the targeted vineyard area was permeable land, the pollution load ratio against rainfall-runoff volume appeared to be 1:1, implying no strong first flush effect for all the survey items.