• Title/Summary/Keyword: stormwater

Search Result 350, Processing Time 0.022 seconds

Evaluation of Catchbasin for Increasing Interception Capability of Stormwater Runoff (강우유출수 차집능력 증대형 빗물받이의 성능 평가)

  • Han, Sangjong;Shin, Hyunjun;Hwang, Hwankook
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.567-575
    • /
    • 2017
  • It is not cost effective to raise the density of catch basins in preparation for heavy rainfall in terms of construction and maintenance. Our researchers have developed the new catch basin for increasing interception capacity of runoff with internal filtration structure. To compare interception capacity of an existing catch basin with the invented catch basin, a hydraulic experiment device with 4% of road gradients and 0.2% of road gradients was constructed. For runoff conditions of 4.4 l/s, 6.7 l/s and 10.4 l/s, capability of runoff and separation capability of debris (sand and leaves) were evaluated. As the main experimental results, the effectiveness of the developed catch basin has been verified with an increase in interception rate of approximately 22% for the runoff of 6.7 l/s as heavy rainfall. However, the results of invented catch basin showed only 4.5% of settlement rate of debris regarding sand. Therefore, the authors proposed an improved tilted screen structure additionally. After reviewing the performance of improved catch basin, application of the invented catch basin is expected to drain runoff effectively when it is applied to the faulty road drainage section.

A Study on the Hydrologic Design of Detention Storage Ponds in Urbanized Area (도시유역에서 지체저류시설의 수문학적 설계에 관한 연구)

  • 이정식;이재준
    • Water for future
    • /
    • v.28 no.3
    • /
    • pp.159-173
    • /
    • 1995
  • This study is to develop the suitable hydrologic models for determination of the size and location of detention storage facilities to restrain stormwater runoff in urban areas. Fictitious areas of two levels are considered to seize the hydrologic response characteristics. A one-square-kilometer area is selected for the catchment level, and a 10-square-kilometer area consisting of 10 catchments is adapted at the watershed level as representative of urban drainage area. In this analysis, different rainfall frequencies, land uses, drainage patterns, basin shapes and detention storage policies are considered. Flow reduction effect of detention storage facilities is deduced from storage ratio and detention basin factor. A substantial saving in detention storage volumes is achieved when the detention storage is planned at the watershed level than the catchment level. For the application of real watersheds, two watersheds in Seoul metropolitan area-Jamshil 2, Seongnae 1-are selected on the basis of hydrologic response characteristics. Through the regression analysis between dimensionless detention storage volume, dimensionless upstream area ratio and reduction rate of storage ratio, the regression equations to determine the size and location of detention storage facilities are presented.

  • PDF

Analysis of Inundation Causes in Urban Area based on Application of Prevention Performance Objectives (도시유역에서의 방재성능목표 적용과 침수원인 분석)

  • kim, Jong-Sub
    • Journal of Wetlands Research
    • /
    • v.18 no.1
    • /
    • pp.16-23
    • /
    • 2016
  • The purpose of this study is to analyze quantitatively the inundation causes by applying the prevention of performance objectives using the urban storm water runoff model XP-SWMM. The model was built by using DTM and storm sewer-network with the storm sewer and geo-data of the study area as input-data to assess the current performance of prevention. An analysis of the causes of the inundation by the frequency and the rainfall-duration. As a result, lack of pipe capacity due to flooding, as well as inundation heavier that the backwater rainfall occurs due to the rise of water level of outside. For solve the inundation damage, It is necessary to improvement pipe of capacity lack and installation of a flood control channel.

Analysis of Nonpoint Source Pollutants in Urban Stormwater Runoff (강우시 도시지역 비점오염물질의 하천 유입 산정)

  • Son, Younggyu
    • Journal of Wetlands Research
    • /
    • v.18 no.1
    • /
    • pp.94-99
    • /
    • 2016
  • Non-point source control has been issued and intensively studied for the control of water quality in streams and rivers. In this study, non-point source pollutants monitoring was conducted at the end of five small streams which were connected to a main stream in three stages including Phase I (one hr before the rainfall), Phase II (one hr after the rainfall), and Phase III (six hrs after the rainfall). For all five small streams, the concentrations and loading rates of non-point source pollutants significantly increased due to the rainfall. As a result of this, priority control streams and priority pollutants were suggested to prepare for future plans of the non-point source control.

Growth Response on the Euonymus fortunei 'Emelad' n 'Gold' as affected by Artificial Plantings Soil Properties during Dry Spring Season (봄철 건조기 용기형 벽면녹화에서 식재지반 조성에 따른 황금줄사철의 적응성)

  • Ju, Jin-Hee;Kim, Hea-Ran;Park, Heon;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.23 no.7
    • /
    • pp.1299-1305
    • /
    • 2014
  • For evaluating the effect of various artificial planting soil properties on the Euonymus fortunei 'Emelad'n Gold' growth, a container green wall system experiment was conducted in a wall of greenhouse at Konkuk University, Glocal campus. The experimental artificial planting grounds were prepared with different organic soil conditioner ratios (Control, $A_4O_1$, $A_2O_1$ and $A_1O_1$) and with drought tolerance and an ornamental value Euonymus fortunei 'Emelad'n Gold' was planted. The soil and plant characteristics were investigated from April to Jun 2010. The volumetric soil moisture contents were significantly increasing order as the amount of organic soil conditioner level increased in order to $A_1O_1$ > $A_2O_1$ > $A_4O_1$ > Control. At 4 treatment, soil chemical properties were inversely related to organic soil container ratios increase. The differences of root collar caliper, number of branch, and survival rate between the organic soil conditioner ratio were not significantly affected by organic soil conditioner. But, plant height, internode length, leaf length and leaf width were significantly shorter on plants planted $A_1O_1$ than plants planted other treatments. Therefore, Euonymus fortunei 'Emelad'n Gold' had good growth response regardless of organic soil conditioner ratio and the plant is expected to be a highly valuable shrub for the green wall system if it should be considered in integration with stormwater retention or as a soil conditioner for increasing soil water contents in artificial planting soil.

Characteristics of Non-point Pollution Discharge on Stormwater Runoff from Lake Doam Watershed (도암호 유역의 강우시 비점오염물질 유출 특성)

  • Kwak, Sung-Jin;Bhattrai, Bal Dev;Kim, Eun-Jung;Lee, Chang-Keun;Lee, Hyeong-Jin;Heo, Woo-Myung
    • Korean Journal of Ecology and Environment
    • /
    • v.45 no.1
    • /
    • pp.62-71
    • /
    • 2012
  • Lake Doam watershed was surveyed to evaluate non-point source discharge characteristics and discharge load including several water quality parameters in Song Stream from July 2009 to July 2011. Concentrations of water pollutants were high during the rainfall period, especially, SS, TP and COD showed increasing tendencies toward cumulative water discharge but TN did not show much difference. SS, TP and COD had an initial flush effect of over 50 mm rainfall event but there was no clear tendency for rainfalls below that level. Event mean concentration (EMC) regarding the rainy and dry period showed large differences. Especially rainy season EMC (SS, TP, COD) demonstrated an increasingly high tendency. EMCs of COD, SS, TN and TP measured for twelve rain events were as high as 26.1, 866.0, 4.68 and 0.605 mg $L^{-1}$, respectively. COD, SS, TN and TP loadings from the highland agricultural region of the Song Stream watershed were 34,263, 1,250,254, 2,673 and 933 kg $yr^{-1}\;km^{-2}$, respectively, which were relatively higher than the results of other stream systems. Therefore, it is strongly recommended that long-term monitoring and non-point pollution reduction programs for the highland agricultural area to continue. Furthermore, this non-point source pollution loading research acquired from the highland agricultural area could be the base for reassessment.

The Effect of Connected Bioretention on Reduction of Surface Runoff in LID Design (LID 설계시 식생체류지간 연결에 의한 강우유출수 저감 효과분석)

  • Jeon, Ji-Hong;Seo, Seong-Cheol;Park, Chan-Gi
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.562-569
    • /
    • 2016
  • Recently, Low Impact Development (LID) is being used in Korea to control urban runoff and nonpoint source pollution. In this study, we evaluated the reduction of surface runoff from a study area, as the effect of connecting three bioretention as LID-BMP. Surface runoff and storage volume of bioretention is estimated by the Curve Number (CN) method. In this study, the storage volume of bioretention is divided by the volume of surface runoff and precipitation which directly enters the bioretention. The ratio of captured surface runoff volume to storage volume is highly influenced by the ratio of drainage area to surface area of bioretention. The high bioretention surface area-to-drainage area ratio captures more surface runoff. The ratio of 1.2 captures 51~54% of the total surface runoff, ranging from 5-30cm of bioretention depth; a ratio of 6.2 captures 81~85%. Three connected bioretentions could therefore captures much more runoff volume, ranging from $35.8{\sim}167.3m^3$, as compared to three disconnected bioretentions at their maximum amount of precipitation with non-effluent from the connecting three bioretentions. Hence, connecting LID-BMPs could improve the removal efficiencies of surface runoff volume and nonpoint source pollution.

Source Identification of Heavy Metal Contamination at an Industrial Complex Established Using Construction Wastes (건설폐기물을 성토재로 사용한 산업단지에서의 중금속 오염 원인 규명)

  • JOO, Gwonho;KIM, Kibeum;NAM, Kyoungphile;JUNG, Jae-Woong;Moon, Seheum;CHOI, Yongju
    • Journal of Soil and Groundwater Environment
    • /
    • v.23 no.1
    • /
    • pp.54-62
    • /
    • 2018
  • This paper is aimed at source tracking of soil heavy metal contamination at a site established by reusing construction wastes. The soil heavy metal concentration at the study site peaked at a depth range of 5-10 m. Column studies were conducted to investigate the possibility of the contamination scenario of infiltration of stormwater carrying heavy metals of ground origin followed by selective heavy metal accumulation at the 5-10 m depth range. Almost all amount of lead, zinc, cadmium, and nickel introduced to the columns each packed with 0-5 m or 5-10 m field soil were accumulated in the column. The very poor heavy metal mobility in spite of the weak association of the heavy metals with the soil (characterized by a sequential extraction procedure) can be attributed to the high pH (10-11) of the construction wastes. From the results, the heavy metal contamination of the subsurface soil by an external heavy metal source was determined to be very unlikely at the study site. The column study applied in the current study is expected to be a useful methodology to present direct evidence of the contaminant source tracking at soil contamination sites.

Stability Evaluation of Phased Isolation Intra-Clarifier Ditch Process on Short-Term Hydraulic Shock Loading (단기 수리학적 충격부하시 침전지 내장형 상분리 산화구공정의 처리 안정성 평가)

  • Hong, Ki-Ho;Chang, Duk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.6
    • /
    • pp.791-799
    • /
    • 2005
  • The phased isolation intra-clarifier ditch system used in this study is a simplified novel process enhancing simultaneous removal of biological nitrogen and phosphorus in municipal wastewater in terms of elimination of additional pre-anaerobic reactor, external clarifier, recycle of sludge, and nitrified effluent recirculation by employing intrachannel clarifier. Laboratory-scale phased isolation ditch system was used to assess the treatability on municipal wastewater. When the system was operated at the HRTs of 6~12hours, SRTs of 9~31days, and cycle times of 2~8hours, the system showed removals of BOD, TN, and TP as high as 88~97%, 70~84%, and 65~90%, respectively. The rainfall in Korea is generally concentrated in summer because of site-specific characteristics. Especially, the wet season has set in on June to August. In combined sewers, seasonal variations are primarily a function of the amount of stormwater that enters the system. In order to investigate the effect of hydraulic shock loading on system performance, the laboratory-scale system was operated at an HRT of 6hours (two times of influent flowrate) during two cycles (8hours). The system performance slightly decreased by increasing of influent flowrate and decreasing of system HRT. Nitrification efficiency and TN removal were slightly decreased by increasing of influent flowrate (decreasing of system HRT), whereas, the denitrification was not affected by hydraulic shock loading. However, the higher system performance could be achieved again after four cycles. Thus, the phased isolation technology for enhanced biological nutrient removal in medium- and small-scale wastewater treatment plants suffering fluctuation of influent quality and flowrate.

The measures to reduce sewer odor in South Korea through sewer odor reduction system in Los Angeles and San Francisco (Los Angeles와 San Francisco의 악취 저감 시스템을 통해 본 우리나라 하수도의 악취 저감 방안)

  • Ji, Hyonwook;Yoo, Sungsoo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.5
    • /
    • pp.445-451
    • /
    • 2018
  • Urban sanitary sewer systems can aid in preventing inundation, and can improve civil health by effectively disposing stormwater and wastewater. However, since sewage odor can cause adverse effects, numerous technical and administrative studies have been conducted for reducing such odor. European countries and the United States of America (USA) built modern sewer systems in the late 19th century, and have since been endeavoring to eliminate sewage odors. Several cities of the USA, such as Los Angeles (LA) that has a separate sewer system and San Francisco (SF) that has a combined sewer system, have produced and distributed odor control master plan manuals. Features common in the odor reduction plans of both these cities are that the odor reduction programs are operated in all the respective local regions and are supported by administrative systems. The primary aspectual difference between the two said programs is that the city of LA employs a sewage air purification system, whereas the city of SF controls the emission of major odor causing compounds. Compared to the existing sewer odor reduction systems of these two cities, South Korea is still in the initial phase of development. Through technical studies and policy implementations for sewer odor reduction, a foundation can be laid for improving the civil health quality.