• 제목/요약/키워드: storage system

검색결과 6,920건 처리시간 0.034초

저온저장고의 뉴로-퍼지 제어시스템 개발 (Development of Neuro-Fuzzy System for Cold Storage Facility)

  • 양길모;고학균;홍지향
    • Journal of Biosystems Engineering
    • /
    • 제28권2호
    • /
    • pp.117-126
    • /
    • 2003
  • This study was conducted to develop precision control system fur cold storage facility that could offer safe storage environment for green grocery. For that reason of neuro-fuzzy control system with learning ability algorithm and single chip neuro-fuzzy micro controller was developed for cold storage facility. Dynamic characteristics and hunting of neuro-fuzzy control system were far superior to on-off and fuzzy control system. Dynamic characteristics of temperature were faster than on-off control system by 1,555 seconds(123% faster) and fuzzy control system by 460 seconds(36.4% faster). When system was arrived at steady state. hunting was ${\pm}$0.5$^{\circ}C$ in on-off control system, ${\pm}$0.4$^{\circ}C$ in fuzzy control system, and ${\pm}$0.3$^{\circ}C$ in neuro-fuzzy control system. Hunting of humidity and wind velocity was also controlled precisely by 70 to 72.5% and 1m/s For storage experiment with onion, characteristics of neuro-fuzzy control system were tested. Dynamic characteristics of neuro-fuzzy control system made cold storage facility conducted precooling ability and minimized hunting.

자연순환식 태양열 급탕 시스템의 성능 추정 방법에 관한 연구 (A Study on the System Performance Prediction Method of Natural Circulation Solar Hot Water System)

  • 윤석범;전문헌
    • 태양에너지
    • /
    • 제7권2호
    • /
    • pp.37-53
    • /
    • 1987
  • This study has been prepared for the purpose of developing the system performance prediction method of natural circulation solar hot water system. The storage tank of the natural circulation solar hot water system equipped with flat-plate solar collector is located at higher elevation than the solar collectors. Therefor, the storage tank temperature distribution formed accordance with configuration of storage tank by flow rate of circulating fluid affect system collection efficiency. In this study measure the storage tank temperature distribution with various experimental system under real sun condition and present the theoretical prediction method of the storage tank temperature. Moreover measure the flow rate not only day-time but also night-time reverse flow rate with die injection visual flow meter. Main conclusion obtain from the present study is as follows; 1) The storage tank temperature distribution above the connecting pipe connection position is the same as that of the fully mixed tank and below the connection position is the same as that of stratified tank. 2) The system performance sensitive to the storage tank temperature distribution. Therefore detailed tank model is necessary. Average storage tank temperature can be calculate 3% and storage tank temperature profile can get less than 10% difference with this model system.

  • PDF

세단 승용차량 트렁크용 휠체어 수납 시스템에 관한 연구 (A Study on the Wheelchair Storage System Mounted on the Trunk of the Sedan Passenger Car)

  • 임구;김영재;김연옥;양순용
    • 드라이브 ㆍ 컨트롤
    • /
    • 제16권3호
    • /
    • pp.8-15
    • /
    • 2019
  • Wheelchair users experience difficulty when using transportation. This is because wheelchair users must use transportation means together with wheelchairs. Therefore, in this paper, we developed a wheelchair storage system for passenger's car trunk. The mechanism is designed to allow a wheelchair and the device to be housed simultaneously in the narrow space of the trunk of the sedan passenger car. Additionally, this wheelchair storage system has implemented an initial load reduction mechanism that can mechanically reduce the initial load. This wheelchair storage system verified the system's operability through the production of the prototype. This system was actually installed in the trunk of the sedan passenger's car to verify the storage process. The operation and storage process of the wheelchair storage system was been perfectly verified. This wheelchair storage system will help a lot of self-driver or an assistant (female or elderly) who use wheelchairs.

전축열방식 빙축열 시스템의 최적제어 알고리즘 (Optimal Control Algorithms for the Full Storage Ice Cooling System)

  • 한도영;이준호
    • 설비공학논문집
    • /
    • 제14권4호
    • /
    • pp.350-357
    • /
    • 2002
  • Optimal control algorithms for the full storage ice cooling system were developed by using a dynamic simulation program. Control algorithms for the storage charging mode were developed for the chiller outlet temperature setpoint control and the chiller capacity control. Control algorithms for the storage discharging mode were developed for the proper mode selection, the storage-only mode control, and the storage-priority chiller-shared mode control. Two different cases of the expected outdoor air temperature profile and the expected cooling load profile were used to analyze the effectiveness of these algorithms. Simulation results show the energy savings and the satisfactory controls of the ice storage system. Therefore, control algorithms developed for this study may effectively be used for the improved control of the ice storage cooling system.

빙축열 냉방시스템의 운전특성 및 비용 분석 (The Operation Characteristics and Cost Analysis of an Ice Thermal Storage System)

  • 안영환;강병하;김석현;이대영
    • 설비공학논문집
    • /
    • 제17권2호
    • /
    • pp.156-164
    • /
    • 2005
  • A comparative analysis of an ice storage system has been performed on the operation cost for the four control strategies, i.e., chiller priority and chiller downstream, chiller priority and chiller upstream, storage priority and chiller upstream, storage priority and chiller downstream. Main components of the ice storage system are an ice-on-coil storage tank and a screw compressor chiller. With the simulation program, the operation cost has been evaluated from the economics of an ice storage system. It is found that the operation cost of the ice storage system is strongly dependent on the control strategy, i.e., chiller priority or storage priority, but less affected by the arrangement method, i.e., chiller upstream or chiller downstream. In case of the maximum load day, the control strategy with chiller priority and chiller upstream is supposed to obtain the reduction of operation cost. However, it is found that the control strategy with storage priority and chiller downstream is the best economical operation for most summer seasons except the maximum load day.

TRNSYS를 이용한 Borehole 방식 태양열 계간축열 시스템의 성능에 관한 연구 (A Study on Performance of Seasonal Borehole Thermal Energy Storage System Using TRNSYS)

  • 박상미;서태범
    • 한국태양에너지학회 논문집
    • /
    • 제38권5호
    • /
    • pp.37-47
    • /
    • 2018
  • The heating performance of a solar thermal seasonal storage system applied to a glass greenhouse was analyzed numerically. For this study, the gardening 16th zucchini greenhouse of Jeollanam-do agricultural research & extension services was selected. And, the heating load of the glass greenhouse selected was 576 GJ. BTES (Borehole Thermal Energy Storage) was considered as a seasonal storage, which is relatively economical. The TRNSYS was used to predict and analyze the dynamic performance of the solar thermal system. Numerical simulation was performed by modeling the solar thermal seasonal storage system consisting of flat plate solar collector, BTES system, short-term storage tank, boiler, heat exchanger, pump, controller. As a result of the analysis, the energy of 928 GJ from the flat plate solar collector was stored into BTES system and 393 GJ of energy from BTES system was extracted during heating period, so that it was confirmed that the thermal efficiency of BTES system was 42% in 5th year. Also since the heat supplied from the auxiliary boiler was 87 GJ in 5th year, the total annual heating demand was confirmed to be mostly satisfied by the proposed system.

홀로그래픽 정보 저장 장치에서의 실시간 틸트 서보 제어 (Real Time Tilt Servo Control of The Holographic Data Storage System)

  • 문재희;김상훈;양준호;양현석;박노철
    • 정보저장시스템학회논문집
    • /
    • 제3권1호
    • /
    • pp.13-16
    • /
    • 2007
  • The purpose of this paper is real time tilt servo control of the holographic data storage system. Holographic data storage device is a next generation data storage device with high storage density, high transfer rate and short access time. This device is very sensitive to a disturbance due to the enormous storage density. As to the recording material changed disc type, the media continuously vibrates as the disc rotates. When disc rotates, deviation, eccentricity and unbalance disturbance are occurred. This disturbances cause disc tilt, finally reference beam does not illuminates to correct incidence angle. Therefore real time tilt servo control is essential. In this paper, the algorithm is proposed to make real time tilt detection in angle multiplexing of the holographic data storage system with an additional servo beam and the experiments are performed.

  • PDF

A New Approach to Servo System Design in Hard Disk Drive Systems

  • Kim, Nam-Guk;Choi, Soo-Young;Chu, Sang-Hoon;Lee, Kang-Seok;Lee, Ho-Seong
    • 정보저장시스템학회논문집
    • /
    • 제1권2호
    • /
    • pp.137-142
    • /
    • 2005
  • In this paper, we propose a new servo system design strategy to reduce the position error signal(PES) and track mis-registration(TMR) in magnetic disk drive systems. The proposed method provides a systematic design procedure based on the plant model and an optimal solution via an optimization with a 'Robust Random Neighborhood Search(RRNS)' algorithm. In addition, it guarantees the minimum PES level as well as stability to parametric uncertainties. Furthermore, the proposed method can be used to estimate the performance at the design stage and thus can reduce the cost and time for the design of the next generation product. The reduction of PES as well as robust stability is demonstrated by simulation and experiments.

  • PDF

A Study on the Future Storage System as brain coordinator

  • Yi, Cheon-Hee;Yi, Jae-Young
    • 반도체디스플레이기술학회지
    • /
    • 제8권1호
    • /
    • pp.39-42
    • /
    • 2009
  • In this paper an attempt for realizing a storage system which works as a part of human brain has been discussed. The system is expected to be able to coordinate with human brain. And current storage may have inherent problem due to an intrinsic attribute of storage, exclusiveness. Directory structure in it must be a source of confusion, if it used out side of the range of limitation. Adapting multidimensional annotation of file name extension and directory-less file system, a new storage system able to associate and coordinate with human brain may be available near future. This paper showed that the limitation of current storage system clearly exists, because of human brain limitation to memorize directory name.

  • PDF

열펌프-잠열축열 시스템의 온실 난방 특성 연구 (Greenhouse Heating Characteristics of Heat Pump-Latent Heat Storage System)

  • 강연구;송현갑
    • Journal of Biosystems Engineering
    • /
    • 제25권5호
    • /
    • pp.379-384
    • /
    • 2000
  • In order to use the natural thermal energy as much as possible for greenhouse heating, the air-air heat pump system involved PCM(phase change material) latent heat storage system was composed, and three types of greenhouse heating system(greenhouse system, greenhouse-PCM latent heat storage system, greenhouse-PCM latent heat storage-heat pump system) were recomposed from the greenhouse heating units to analyze the heating characteristics. The results could be concluded as follows; 1) In the greenhouse heated by the heat pump under the solar radiation of 406.39W/$m^2$, the maximum PCM temperature in the latent heat storage system was 24$^{\circ}C$ and the accumulated thermal energy stored in PCM mass of 816kg during the daytime was 100,320kJ. In the greenhouse without heat pump under the maximum solar radiation of 452.83W/$m^2$, the maximum PCM temperature in the latent heat storage system was 22$^{\circ}C$ and the accumulated thermal energy stored during the daytime was 52.250kJ. 2) In the greenhouse-PCM system without heat pump the heat stored in soil layers from the surface to 30cm of the soil depth was 450㎉/$m^2$. 3) In all of the greenhouse heating systems, the difference between the air temperature in greenhouse and the ambient temperature was about 20~23$^{\circ}C$ in the daytime. In the greenhouse without heat pump and PCM latent heat storage system the difference between the ambient temperature and the air temperature in the greenhouse was about 6~7$^{\circ}C$ in the nighttime, in the greenhouse with only PCM latent heat storage system the temperature difference about 7~13$^{\circ}C$ in the nighttime and in the greenhouse with the heat pump and PCM latent heat storage system about 9~14$^{\circ}C$ in the nighttime.

  • PDF