• Title/Summary/Keyword: storage ratio

Search Result 1,433, Processing Time 0.029 seconds

Numerical Study on Thermal Stratification of the Aspect ratio of Solar Thermal Storage Tank (태양열 축열조의 종횡비에 따른 열성층화 수치해석 연구)

  • Joo, Hong-Jin;Kim, Jung-Bae;Kwak, Hee-Youl
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.178-183
    • /
    • 2008
  • The purpose of this study is to compare the effect on the thermal stratification under various aspect ratios in the solar storage tank using FLUENT. Numerical calculations of three designs with different aspect ratio were carried out to show the behaviour of stratification in a solar storage tank. The calculation results show that the thermal stratification of the 2.5:1 aspect ratio solar storage tank can be 6.22% higher then that of the 1.5:1 aspect ratio solar storage tank and 2.68% higher then that of the 2:1 aspect ratio solar storage tank.

  • PDF

Estimation on Storage Yard Occupancy Ratio of Container Terminal: A Case of Busan New Port Container Terminal (컨테이너터미널 장치장 점유율 추정 연구: 부산항 신항 컨테이너 터미널을 중심으로)

  • Kim, GeunSub
    • Journal of Navigation and Port Research
    • /
    • v.45 no.3
    • /
    • pp.148-154
    • /
    • 2021
  • With advancements of quay side handling equipment and technologies, congestion in terminal operation has moved to the storage yard side from the quay side. The importance of storage yard management has increased in overall terminal operation. Thus, many studies have been conducted to optimize the storage yard management of container terminals. However, there is no academic work to estimate the change of storage yard occupancy ratio by itself in the future. This paper examines the probability of storage yard occupancy ratio in the container terminal of Busan New port using the Markov chain analysis which explains probability change with passing time. The result shows that it is most likely to have the probability of maintaining a high level of storage yard occupancy ratio in the container terminal of Busan New Port.

Storage Characteristics of Rough Rice by Storage Method (저장방법에 따른 벼의 저장특성)

  • Lee, J.S.;Hong, H.K.;Kang, T.H.;Li, H.;Ham, T.M.;Kim, Y.H.;Han, C.S.
    • Journal of Biosystems Engineering
    • /
    • v.33 no.3
    • /
    • pp.167-172
    • /
    • 2008
  • The objective of this study was to investigate the adequate storage method that was able to maintain the high quality of rough rice according to storage methods and period. The quality change of the rough rice during the storage period was evaluated by storage method such as cooling bin using winter cold air, ordinary temperature bin, freezing, refrigeration and indoor storage. Moisture content, brown rice whiteness, hardness, crack ratio and germination ratio were measured in this study. Moisture content of rough rice stored in cooling bin using winter cold air and ordinary temperature bin were decreased by 0.07% and 0.42%, respectively, which were lower than the other storage method. The hardness of brown rice increased in order of storage method such as winter cooling bin, normal bin, freezing storage, refrigeration storage and indoor storage. Crack ratio by indoor and ordinary temperature bin storage were increased by 2.68% and 3.63%, respectively, whereas cooling bin using winter cold air, refrigeration and freezing storage showed below 1.0%. The highest germination rate was found in cooling bin using winter cold air. As a result, cooling bin using winter cold air can be evaluated for the adequate storage method of rough rice.

A Study on the Performance for the Cylindrical Packed Bed Sensible Heat Storage Unit (충진층 현열 축열조의 성태해소에 관한 연구)

  • Kwon, Sun-Seok;Kim, Si-Beom;Gu, Bon-Yeong
    • Journal of Ocean Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.85-93
    • /
    • 1990
  • A numerical study on the cylindrical packed bed sensible heat storage unit was accomplished by finite difference method. Relation between the heat storage rate and the mechanical pumping energy and the characteristics of the heat storage were investigated for various in let velocities and porosities. In this study, the numerical results are as follows: 1) The temperature distributions of solid and fluid rapidly reached the steady state as the heat capacity ratio was increased. 2) The efficiency of the heat storage was increased as the heat capacity ratio was decreased. For constant heat capacity ratio, however, the efficiency of the heat storage was increased at lower porosity. 3) It is very profitable to design the heat storage system such that the porosity is larger for the large flow rate and samller for small flow rate.

  • PDF

A Study on the Performance for the Cylindrical Packed Bed Sensible Heat Storage Unit (충진층 현열 축열조의 성태해소에 관한 연구)

  • Kwon, Sun-Seok;Kim, Si-Beom;Gu, Bon-Yeong
    • Journal of Ocean Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.235-235
    • /
    • 1990
  • A numerical study on the cylindrical packed bed sensible heat storage unit was accomplished by finite difference method. Relation between the heat storage rate and the mechanical pumping energy and the characteristics of the heat storage were investigated for various in let velocities and porosities. In this study, the numerical results are as follows: 1) The temperature distributions of solid and fluid rapidly reached the steady state as the heat capacity ratio was increased. 2) The efficiency of the heat storage was increased as the heat capacity ratio was decreased. For constant heat capacity ratio, however, the efficiency of the heat storage was increased at lower porosity. 3) It is very profitable to design the heat storage system such that the porosity is larger for the large flow rate and samller for small flow rate.

Design of Detention Pond and Critical Duration of Design Rainfall in Seoul

  • Lee, Jong-Tae;Yoon, Sei-Eui;Lee, Jae-Joon
    • Korean Journal of Hydrosciences
    • /
    • v.5
    • /
    • pp.33-43
    • /
    • 1994
  • This study is to determine the critical duration of design rainfall and to utilize it for the design of detention pond with pump station. To examine the effect of the duration and temporal distribytion of the design rainfall, Huff's quartile method is used for the 9 cases of durations (ranges from 20 to 240 minutes) with ten years return period, and the ILLUDAS model is used for runoff analysis. The storage ratio, which is the ratio of maximum storage amounts to total runoff volume, is introduced to determine the criticalduration of design rainfall. The duration which maximizes the storage ratio is adopted as the critical duration. This study is applied to 18 urban drainage watercheds with pump station in Seoul, of which the range of watershed area is 0.24~12.70$km^2$. The result of simulation shows that the duration which maximizes storage ratio is 30 and 60 minutes on the whole. It is also shown that the storage ratios of 2nd - and 3rd-quartile pattern are larger than those of 1st- and 4th-quartile pattern of temporal distribution. A simplified empirical formula for Seoul area is suggested by the regression analysis between the maximum storage ratio and the peak ratio. This formula can be utilized for the preliminary design and planning of detention pond with pump station.

  • PDF

Characteristic of the Rice Quality with Long-term Storage of Paddy (장기저장 미곡의 품질 특성)

  • 소규호;김영수;홍재식;정준영;조재민
    • The Korean Journal of Food And Nutrition
    • /
    • v.13 no.1
    • /
    • pp.21-27
    • /
    • 2000
  • In order to investigate the changes of rice qualities during 4 years storage of paddy in warehouse of normal temperature condition. As storage period go by, head ratio was deduced and broken rice was increased according as a change of temperature during the long term storage. A color of rice was became more dark gray than that of entering time as L value was decreased from 64.07 to 61.62 a 4 years late. As a results of studies on the cooking quality of milled rice, water uptake ratio and expanded volume were increased in proporation to storage period, wherease total solids and iodine blue value were decreased. In the characteristic of texture of cooked rice, viscosity/hardness ratio(-H/H) had a decreasing tendency, while adhesiveness and cohesiveness increased with increased storage time. The qualities of cooked milled rice studied were sensory attributies of odor, taste, stickiness and appearance which were evaluvated by multiple comparsion method. The sensory results showed that all of descriptions were deterirated with a increased storage period. The taste and stickiness were changed from good score to bad score a 2 years later.

  • PDF

Effects of Storage Conditions on Weight Loss and Free Sugar Composition of Fresh Ginseng (보관조건에 따른 수삼의 중량과 유리당 조성 변화)

  • Chang, Jin-Kyu;Kim, Cheon-Sug;Nho, Kil-Bong;Cho, Byung-Goo
    • Journal of Ginseng Research
    • /
    • v.29 no.2
    • /
    • pp.113-118
    • /
    • 2005
  • This study was to examine the effect of the opening ratio (area of spile hole/total surface area) of plastic container and storage temperature on physicochemical changes of fresh ginseng. At room temperature ($19\~23^{\circ}C$, RH $40\~61\%$), fungi and spoilage were observed 4 and 10 days, respectively after storing the fresh ginseng in a closed container. In storage container with $1\%$ opening ratio, fungi appeared 8 days after storage. In the container with $5\%$ and $10\%$ opening ratio, fresh ginseng showed excessive loss of moisture on the surface only after 4 days. The weight loss was most remarkable in the container with 5 and $10\%$ opening ratio. Content of maltose and sucrose decreased gradually in accordance with storage time but the extent of decreasing ratio was less significant in the container with lower opening ratio. At low temperature $(4\~9^{\circ}C,\;RH\;72\~92\%)$, no fungi but $10\%$ loss of weight was observed in the container with $5\%$ and $10\%$ opening ratio after 12 days storage. But in the tightly closed container and $1\%$ opening ratio for spiting, fresh ginseng showed good appearance even after 30 days of storage. Free sugars, especially maltose revealed gradual decrease but sucrose gradually increase following decrease at the beginning. This result suggests that storage condition of low temperature and opening ratio of plastic box less than $1\%$ can extend storage span of fresh ginseng significantly.

Sediment in Agricultural Reservoir and Variation of Storage (농업용 저수지의 토사퇴적과 내용적 변화)

  • Park, Jae-Heung;Jeon, Doh-Cheol;Kim, Jae-Jin
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.74-79
    • /
    • 2005
  • Many reservoirs have been constructed for sustainable utilization of water resources in Korea. Effective management of water resources in Korea becomes very important in resent years. Especially, the dredging in reservoirs is important for effective water resources management and one in easy water resources security methods. According to "The reservoir dredging mid-long term planning investigation report", it was investigated that 1221 reservoirs need to dredge among 3,288 reservoirs managed by KARICO. And, KARICO made a survey of reservoirs for the sediment and storage change in $2002{\sim}2004$. In results, it was investigated total storage $1,406{\pm}10^6m^3$, effective storage $1,344{\pm}10^6m^3$ in mid-small 2,748 reservoirs and the storage ratio decreased total storage ratio 15.7%, effective storage ratio 4.4%.

  • PDF

Thermal Stratification and Heat Loss in Underground Thermal Storage Caverns with Different Aspect Ratios and Storage Volumes (지하 열저장 공동의 종횡비와 저장용량에 따른 열성층화 및 열손실)

  • Park, Dohyun;Ryu, Dong-Woo;Choi, Byung-Hee;Sunwoo, Choon;Han, Kong-Chang
    • Tunnel and Underground Space
    • /
    • v.23 no.4
    • /
    • pp.308-318
    • /
    • 2013
  • Thermal stratification in heat stores is essential to improve the efficiency of energy storage systems and deliver more useful energy on demand. It is generally well known that the degree of thermal stratification in heat stores varies depending on the aspect ratio (the height-to-width ratio) and size of the stores. The present study aims to investigate the effect of the aspect ratio and storage volume of rock caverns for storing hot water on thermal stratification in the caverns and heat loss to the surroundings. Heat transfer simulations using a computational fluid dynamics code, FLUENT were performed at different aspect ratios and storage volumes of rock caverns. The variation of thermal stratification with respect to time was examined using an index to quantify the degree of stratification, and the heat loss to the surroundings was evaluated. The results of the numerical simulations demonstrated that the thermal stratification in rock caverns was improved by increasing the aspect ratio, but this effect was not remarkable beyond an aspect ratio of 3-4. When the storage volume of rock caverns was large, a higher thermal stratification was maintained for a relatively longer time compared to caverns with a small storage volume, but the difference in thermal stratification between the two cases tended to decrease as the aspect ratio became larger. In addition, the numerical results showed that the heat loss to the surrounding rock tended to increase with an increase in aspect ratio because the surface area of rock caverns increased as the aspect ratio became larger. The total heat loss from multiple small caverns with a reduced storage volume per cavern was larger compared to a single cavern with the same total storage volume as that of the multiple caverns.