• Title/Summary/Keyword: storage period and method

Search Result 448, Processing Time 0.027 seconds

Development of a Solar Collector Performance of Cylindrical Parabolic Concentrating Solar Collector (태양열(太陽熱) 집열기개발(集熱器開發)에 관(關)한 연구(硏究) - 포물반사곡면(抛物反射曲面)으로된 2차원(二次元) 집광식(集光式) 태양열(太陽熱) 집열기(集熱器)의 성능분석(性能分析) -)

  • Song, Hyun Kap;Yon, Kwang Seok;Cho, Sung Chan
    • Journal of Biosystems Engineering
    • /
    • v.10 no.1
    • /
    • pp.54-68
    • /
    • 1985
  • It is desirable to collect the solar thermal energy at relatively high temperature in order to minimize the size of thermal storage system and to enlarge the scope of solar thermal energy utilization. So far the concentrating solar collector has been developed to collect solar thermal energy at relatively high temperature, but it has some difficulties in maintaining the volumetric body of solar collector for long term utilization. On the other hand, the flat-plate solar collector has been developed to collect the solar thermal energy at low temperature, and it has advantages in maintaining the system for long term utilization, since it's thickness is thin and not volumetric. In this study, to develop a solar collector that has both advantages of collecting solar thermal energy at high temperature and fixing conveniently the collector system for long term period, a cylindrical parabolic concentrating solar collector was designed, which has two rows of parabolic reflectors and thin thickness such as the flat-plate solar collector, maintaining the optical form of concentrating solar collector. The characteristics of the concentrating parabolic solar collector newly designed was analysed and the results are summarized as follows; 1. The temperature of the air enclosed in solar collector was all the same as $50^{\circ}C$ in both cases of the open and closed loop, and when the heat transfer fluid was not circulated in tubular absorber, the maximum surface temperature of the absorber was $118-120^{\circ}C$, this results suggested that the heat transfer fluid could be heated up to $118^{\circ}C$. 2. In case of longitudinal installation of the solar collector, the temperature difference of heat transfer fluid between inlet and outlet was $4^{\circ}-6^{\circ}C$ at the flow rate of $110-130{\ell}/hr$, and the collected solar energy per unit area of collector was $300-465W/m^2$. 3. The collected solar energy per unit area for 7 hours was 1960 Kcal/$m^2$ for the open loop and 220 Kcal/$m^2$ for the closed loop. Therefore it is necessary to combine the open and closed loop of solar collectors to improve the thermal efficiency of solar collector. 4. The thermal efficiency of the solar collector (C.P.C.S.C.) was proportional to the density of solar radiation, indicating the maximum thermal efficiency ${\eta}_{max}=58%$ with longitudinal installation and ${\eta}_{max}=45%$ with lateral installation. 5. The thermal efficiency of the solar collector (C.P.C.S.C.) was increased in accordance with the increase of flow rate of heat transfer fluid, presenting the flow rate of $110{\ell}/hr$ was the value of turning point of the increasing rate of the collector efficiency, therefore the flow rate of $110{\ell}/hr$ was considered as optimum value for the test of the solar collector (C.P.C.S.C.) performance when the heat transfer fluid is a liquid. 6. In both cases of longitudinal and lateral installation of the solar collector (C.P.C.S.C.), the thermal efficiency was decreased linearly with an increase in the value of the term ($T_m-T_a$)/Ic and the increasing rate of the thermal efficiency was not effected by the installation method of solar collector.

  • PDF

Antioxidative and Biological Activites of Extracts of Sweetpotato Tips (고구마 끝순 추출물의 항산화 및 생리활성)

  • Lee, Joon-Seol;Park, Yang-Kyun;Ahn, Young-Sup;Kim, Hag-Sin;Chung, Mi-Nam;Jeong, Byeong-Choon;Bang, Jin-Ki
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.52 no.2
    • /
    • pp.228-238
    • /
    • 2007
  • This study was conducted to increase sweetpotato utilization and to determine the vegetative value of sweetpotato tips by investigating the phenolic compounds, antioxidative effect in oil, electron donating ability, nitrite scavenging effect and ACE inhibition activities. The phenolic compounds present in sweetpotato tips are the gallic, chlorogenic, gentisic, caffeic, couramic and ferulic acid, which are 16-122 times higher compared to other vegetables such as spinach, soybean sprout, and perilla leaves. In each solvent extract, the total phenolic compounds (175.8mg/g) was composed of 55% EtOAc extraction and 39% BuOH extract, respectively. The results of induction period using the Rancimat method showed that the antioxidant activity of SP tips was higher than the tocopherol or BHT. The relative levels of each solvent extract in SP tips were as follows: EtOAc>BHT>BuOH>Tocopherol>Water>$CHCl_3$>Hexane. The peroxide value was measured every 5 days for 25 days during storage and results showed that the peroxide value, the tips, tuberous root and tocopherol were lower compared to spinach, soybean sprout and perilla leaves. Nitrite scavenging effects were excellent in sweetpotato tips, perilla leaves and soybean sprout, especially, inhibition rate of perilla leaves (72%) were superior to the others. In process of solvent extraction, activity of BuOH and water extractions were the best. ACE inhibition activity in sweetpotato tips was 1.5 times higher than in tuberous roots and $1.9{\sim}3.7$ times higher than in spinach, soybean sprout, perilla leaves.

A Study on Quality Changes of Domestic Frying Oils by Thermal Oxidation (시판식용유의 가열시간에 따른 품질 변화에 관한 연구)

  • Chang, You-Kyung;Lee, Joung-Won;Kim, Teak-Je
    • Korean Journal of Food Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.112-118
    • /
    • 1978
  • Four domestic frying oils (soybean, corn, rapeseed and rice bran oil) were studied on their changing properties according to thermal oxidation by means of chemical analysis of their compositions and measurements of various physical and chemical properties. The content of linoleic acid which is an essential unsaturated fatty acid and the total amount of unsaturated fatty acids were highest in soybean oil (53.2% and 80.3% respectively) among the unheated frying oils and the degree of its thermal degradation was lowest during the continuous heating period for 48 hours at $180^{\circ}C$. However in general, the contents of unsaturated fatty acids were sharply decreased by thermal oxidation whereas the saturated fatty acid contents ranging 10-17% were not changed considerably, which largely agreed with the results of iodine value measurements. The free acid and peroxide values were also lowest in soybean oil (0.09 and 5.6 respectively) among the unheated oils whereas an anomalously high free acid value was observed in rapeseed oil (54.8) which was packed in unleveled glass bottles. Such a high value is probably ascribed to the photo-catalyzed oxidation during storage. The viscosity measurements have shown similar values before heating, but after thermal oxidation for 32 hours the rapeseed and rice bran oils became too thick to measure viscosity by capillary flow method with heavy darkening in color.

  • PDF

Comparative Quality Evaluation of King Oyster Mushroom as Affected by Unit Packaging Method during Simulated Export Shipment (큰느타리버섯의 모의 수출운송과정에서 소포장 적용에 따른 품질변화 비교)

  • Woo, Seong-Min;Park, Youn-Moon;Park, Se Won
    • Horticultural Science & Technology
    • /
    • v.31 no.2
    • /
    • pp.186-193
    • /
    • 2013
  • Potential of consumer unit packaging was investigated for quality maintenance during export simulation in king oyster mushrooms (Pleurotus eryngii). Mushrooms were harvested in late May, precooled to $4^{\circ}C$ within 6 hours, and then packaged for shipping in two ways: 2 kg bulk packaging in a polyethylene (PE) bag or three types of unit packaging methods such as 400 g in polypropylene film bag (PPB), 200 g on styrofoam tray + PE shrinkage film wrapping (STW), and 200 g in polyethylene terephthalate (PET) containers (PETC). For local distribution of bulk-packaged commodity, mushrooms were sorted again and packaged into 3 consumer units in the same way as for the initial shipping packages. Simulation of refrigerated container shipping was performed in a walk-in type pilot storage at $0.5^{\circ}C$ for 5 weeks, while local marketing simulation was carried out on the shelf at $7^{\circ}C$ for 7 days. During the shipment simulation, creation of modified atmosphere (MA) was substantial in 2 kg bulk packages with low $O_2$ below 2% and high $CO_2$ over 15% whereas, in PPB and PETC unit packages, relatively higher $O_2$ concentrations were observed. On the shelf at $7^{\circ}C$, $CO_2$ concentrations rapidly increased in PPB and PETC packages despite the short marketing period. Overall marketability evaluated by off-flavor, browning, and texture rating was maintained at excellent level when 2 kg bulk packaging in PE or unit packaging in PPB and PETC were used for shipment. In contrast, establishment of MA was very slight in STW packages during shipment and local distribution resulting in poor quality after export simulation. The results suggested that shipment using adequate consumer unit packaging is more practical and economically beneficial than using bulk packaging in the export program consisting of 5-week shipment and 7-day local distribution.

Antioxidative and Biological Activites of Extracts of Sweetpotato Tips (고구마 끝순 추출물이 알코올 투여 흰쥐의 항산화 효소계 및 지질과산화에 미치는 영향)

  • Lee, Joon-Seol;Park, Yang-Kyun;Ahn, Young-Sup;Kim, Hag-Sin;Chung, Mi-Nam;Jeong, Byeong-Choon;Bang, Jin-Ki
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.52 no.4
    • /
    • pp.411-420
    • /
    • 2007
  • This study was conducted to increase sweetpotato utilization and to determine the vegetative value of sweetpotato tips by investigating the phenolic compounds, antioxidative effect in oil, electron donating ability, nitrite scavenging effect and ACE inhibition activities. The phenolic compounds present in sweetpotato tips are the gallic, chlorogenic, gentisic, caffeic, couramic and ferulic acid, which are 16-122 times higher compared to other vegetables such as spinach, soybean sprout, and perilla leaves. In each solvent extract, the total phenolic compounds(175.8 mg/g) was composed of 55% EtOAc extraction and 39% BuOH extract, respectively. The results of induction period using the Rancimat method showed that the antioxidant activity of SP tips was higher than the tocopherol or BHT. The relative levels of each solvent extract in SP tips were as follows: EtOAc>BHT>BuOH>Tocopherol>Water>$CHCl_3$>Hexane. The peroxide value was measured every 5 days for 25 days during storage and results showed that the peroxide value, the tips, tuberous root and tocopherol were lower compared to spinach, soybean sprout and perilla leaves. Nitrite scavenging effects were excellent in sweetpotato tips, perilla leaves and soybean sprout, especially, inhibition rate of perilla leaves(72%) were superior to the others. In process of solvent extraction, activity of BuOH and water extractions were the best. ACE inhibition activity in sweetpotato tips was 1.5 times higher than in tuberous roots and $1.9{\sim}3.7$ times higher than in spinach, soybean sprout, perilla leaves.

Relationship between Compressive Strength and Dynamic Modulus of Elasticity in the Cement Based Solid Product for Consolidating Disposal of Medium-Low Level Radioactive Waste (중·저준위 방사성 폐기물 처리용 시멘트 고화체의 압축강도와 동탄성계수의 관계)

  • Kim, Jin-Man;Jeong, Ji-Yong;Choi, Ji-Ho;Shin, Sang-Chul
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.3
    • /
    • pp.321-329
    • /
    • 2013
  • Recently, the medium-low level radioactive waste from nuclear power plant must be transported from temporary storage to the final repository. Medium-low level radioactive waste, which is composed mainly of the liquid ion exchange resin, has been consolidated with cementitious material in the plastic or iron container. Since cementitious material is brittle, it would generate cracks by impact load during transportation, signifying leakage of radioactive ray. In order to design the safety transporting equipment, there is a need to check the compressive strength of the current waste. However, because it is impossible to measure strength by direct method due to leakage of radioactive ray, we will estimate the strength indirectly by the dynamic modulus of elasticity. Therefore, it must be identified the relationship between of strength and dynamic modulus of elasticity. According to the waste acceptance criteria, the compressive strength of cement based solid is defined as more than 3.44 MPa (500 psi). Compressive strength of the present solid is likely to be significantly higher than this baseline because of continuous hydration of cement during long period. On this background, we have tried to produce the specimens of the 28 day's compressive strength of 3 to 30 MPa having the same material composition as the solid product for the medium-low level radioactive waste, and analyze the relationship between the strength and the dynamic modulus of elasticity. By controling the addition rates of AE agent, we made the mixture containing the ion exchange resin and showing the target compressive strength (3~30 MPa). The dynamic modulus of elasticity of this mixtures is 4.1~10.2 GPa, about 20 GPa lower in the equivalent compressive strength level than that of ordinary concrete, and increasing the discrepancy according to increase strength. The compressive strength and the dynamic modulus of elasticity show the liner relationship.

Effect of Paddy Drying by Solar Energy Concentration Blast-Grain Circulation Dryer (태양열집열송풍(太陽熱集熱送風), 곡물순환식(穀物循環式) 건조기(乾燥機)의 벼 건조효과(乾燥效果))

  • Lee, B.Y.;Kim, Y.B.;Son, J.R.;Yoon, I.H.;Han, P.J.
    • Applied Biological Chemistry
    • /
    • v.32 no.2
    • /
    • pp.104-108
    • /
    • 1989
  • A 2.5 ton scale of solar energy concentration blast-grain circulation dryer (SECD) was developed in order to shorten the drying time without damaged paddy. Comparative experiments were carried out on performance, drying efficiency, consistency in moisture content, milling recovery, grade of milled rice, and energy requirement and cost against all that of in-bin drying and storage (IBDS) method. The experiments were performed using mixture of several rice varieties of Tongil type(Japonica-Indica breeding type) under the autumn weather in Korea. The circulating air temperature inside SECD was $4{\sim}5^{\circ}C$ higher than that of IBDS. The moisture content of the paddy during the drying period in SECD was uniform while substantially varied in upper, middle or bottom layer in IBDS. By SECD, 24% initial moisture content of paddy was reduced to 15% after only 3 days of drying as compared to 14 days at IBDS. The percentage of cracked kernels in upper, middle and bottom layers in IBDS was 6, 6 and 12%, respectively, whereas 7% in all layers in SECD. Both types of dryers did not significantly affect the milling recovery of dried paddy and grade of milled rice. Energy requirement of SECD(28.8Kw/2.5ton) for paddy drying was much less than that of IBDS(108Kw/2.5ton).

  • PDF

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF