• Title/Summary/Keyword: storage facility

Search Result 616, Processing Time 0.023 seconds

Seismic Behavior Characteristics of Spherical Storage Tanks Supported by Inelastic Members and Performance-Based Seismic Design Based on Reliability (비선형지지구조 저장탱크의 지진거동 특성과 신뢰도 기반의 성능기반 내진설계)

  • Jang jeong min;Sun chang ho;Kim ick hyun;Choi jeong in
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.4
    • /
    • pp.27-33
    • /
    • 2023
  • In a petrochemical plant, various mechanical equipments and structures are interconnected to ensure operability. Since the production activities of petrochemical plants have a great impact on the national economy, it is very important to maintain not only structural safety but also the operability of the facilities. However, the current seismic design standards present the design requirements of facilities mainly aimed at preventing collapse, and do not provide the requirements for securing operability of facilities. Depending on the behavioral characteristics of the facility, operability of the facility can be secured by seismic performance levels other than the collapse prevention level, so it is necessary to present seismic design methods that can apply various seismic performance levels. Spherical (ball) storage tanks are supported by columns and braces and exhibit complex nonlinear behavior because of buckling and yielding of support members. In this study, nonlinear seismic behavior characteristics were statistically analyzed and a new performance-based seismic design method was proposed based on them.

SHIELDING ANALYSIS OF DUAL PURPOSE CASKS FOR SPENT NUCLEAR FUEL UNDER NORMAL STORAGE CONDITIONS

  • Ko, Jae-Hun;Park, Jea-Ho;Jung, In-Soo;Lee, Gang-Uk;Baeg, Chang-Yeal;Kim, Tae-Man
    • Nuclear Engineering and Technology
    • /
    • v.46 no.4
    • /
    • pp.547-556
    • /
    • 2014
  • Korea expects a shortage in storage capacity for spent fuels at reactor sites. Therefore, a need for more metal and/or concrete casks for storage systems is anticipated for either the reactor site or away from the reactor for interim storage. For the purpose of interim storage and transportation, a dual purpose metal cask that can load 21 spent fuel assemblies is being developed by Korea Radioactive Waste Management Corporation (KRMC) in Korea. At first the gamma and neutron flux for the design basis fuel were determined assuming in-core environment (the temperature, pressure, etc. of the moderator, boron, cladding, $UO_2$ pellets) in which the design basis fuel is loaded, as input data. The evaluation simulated burnup up to 45,000 MWD/MTU and decay during ten years of cooling using the SAS2H/OGIGEN-S module of the SCALE5.1 system. The results from the source term evaluation were used as input data for the final shielding evaluation utilizing the MCNP Code, which yielded the effective dose rate. The design of the cask is based on the safety requirements for normal storage conditions under 10 CFR Part 72. A radiation shielding analysis of the metal storage cask optimized for loading 21 design basis fuels was performed for two cases; one for a single cask and the other for a $2{\times}10$ cask array. For the single cask, dose rates at the external surface of the metal cask, 1m and 2m away from the cask surface, were evaluated. For the $2{\times}10$ cask array, dose rates at the center point of the array and at the center of the casks' height were evaluated. The results of the shielding analysis for the single cask show that dose rates were considerably higher at the lower side (from the bottom of the cask to the bottom of the neutron shielding) of the cask, at over 2mSv/hr at the external surface of the cask. However, this is not considered to be a significant issue since additional shielding will be installed at the storage facility. The shielding analysis results for the $2{\times}10$ cask array showed exponential decrease with distance off the sources. The controlled area boundary was calculated to be approximately 280m from the array, with a dose rate of 25mrem/yr. Actual dose rates within the controlled area boundary will be lower than 25mrem/yr, due to the decay of radioactivity of spent fuel in storage.

Development of the Hospital Foodservice Facility Evaluation tools based on the General HACCP-based Sanitation Standards and Guidelines (병원급식에 일반위생관리기준과 HACCP 제도 적용을 위한 시설ㆍ설비 위생관리 점검도구 개발)

  • 이정숙;곽동경;강영재
    • Korean journal of food and cookery science
    • /
    • v.19 no.3
    • /
    • pp.339-353
    • /
    • 2003
  • The rapid increase in food borne illness outbreaks in Korea has been one of the major threats to the Nation's Health. Foodservice establishments have been identified as the major place for these outbreaks, mainly due to the lack of sanitary management and sanitary facility management practices. The purposes of the study were to develop hospital foodservice facility evaluation tools, based on the general HACCP-based standards and guidelines, for hospital food service establishments, to ensure the safety of these foodservices and to reduce the risk of food home illness. The scope of this study included: 1) an assessment of the current foodservice sanitation practices and managements for 6 general hospitals, with more than 400 beds, and 3 general hospitals, with less than 400 beds; 2) the development of foodservice establishments sanitation evaluation tools and sanitation standards, based on the HACCP system. The survey data showed varied results between the hospitals surveyed. Most of the hospital foodservice operations had many problems with ventilation and the plumbing. The total dimensional mean scores for the hospitals with more than 400 beds and less than 400 beds were 31.5 and 27.0, respectively. The highest dimension scores were for the water supply facility and lighting, with the lowest for insect and rodent control and toxic materials management. The levels of the mean scores were very low, especially for the general hospitals with less than 400 beds. These low mean scores may have arisen from critical problems within the hospital foodservice operations. The most needed facility management items for improvement were: storage shelf should be spaced 6 inches from the floor and walls, the use of three compartment sinks, utility sinks and cleaning facilities, with a floor drain for cleaning mops or liquid wastes, a ventilation hood designed to prevent dripping onto food, cooking facilities should be disassembled for washing and sanitizing, a separated hand washing sink and a sanitized food board for each area should be provided, all toxic material must have warning labels attached, and be stored in an area away from food preparation under padlock. The evaluation tool consisted of 14 dimensions, with 65 check-off items. The results of this study will provide basic facilities' guidelines to regulators, or foodservice industry personnel, wishing to build, or expend, and establish an efficient flow of food. As a result, food borne illnesses will be effectively prevented, and the Nation's health will be promoted for the development of their own sanitation standards, with a checklist for the safe production of foods.

Impact Assessment of the Damage by a Pool Fire in Yard Storage Facilities of a Container Terminal (컨테이너 터미널 옥외저장소에서의 액면화재에 대한 피해영향 평가)

  • Hwang, Man Woong;Lee, Ik Mo;Hwang, Yong Woo;Chun, Young Woo
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.2
    • /
    • pp.33-42
    • /
    • 2016
  • Domestic harbor yard storage facilities are a place specifically located in a container terminal for import and export of packaged dangerous goods, and due to the recent relaxed criteria for the secured open area, concerns for the extended damage upon accidents are increasing. In this study, the impact of damages by radiant heat was analyzed through a simulation of a pool fire caused by the leakage of flammable liquids from a tank container. As a result, it was analyzed that the distance of radiant heat according to threshold damage levels was beyond the current criteria of the secured open area, and the structural damage of adjacent containers could happen within a very short time if they were exposed to the early pool fire continuously. It is considered that this study will be helpful in preparing the proper criteria for the secured open area between yard storage facilities in a container terminal.

Evaluation of ground characteristics near underground rainfall storage facilities using shear wave velocity (전단파 속도를 이용한 지하 저류조 주변 지반특성 평가)

  • Jo, Seon-Ah;Oh, Tae-Min;Cho, Gye-Chun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.2
    • /
    • pp.225-236
    • /
    • 2014
  • Shear wave velocity was used to estimate the geotechnical characteristics (void ratio and shear strength) of ground near an underground rainfall storage facility. An oedometer cell was utilized to measure the shear wave velocity and the displacement of specimens. Shear strengths were obtained by direct shear tests. The relationships along the shear wave velocity, void ratio, and shear strength were verified and used to infer the shear strength profile with the depth. In addition, changes in shear strength due to the construction of the underground rainfall storage system were estimated using the suggested method. The results show that the in-situ shear strength deduced from the shear wave velocity-void ratio-shear strength relationship is in good agreement with that obtained from an in-situ investigation (SPT).

An experimental study on characteristics of hydraulic stability for stable management prepare continuous flood in Shinwol rainwater storage and drainage system (신월 빗물저류배수시설의 연속강우 대비 안정적 운영을 위한 수리적 안정 특성에 대한 실험 연구)

  • Oh, Jun Oh;Kim, Young Do;Jun, Sang Mi
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.6
    • /
    • pp.451-461
    • /
    • 2020
  • Urban flooding due to rapid urbanization has recently become frequent. In this study, a hydraulic model experiment was conducted on Shinwol rainwater storage and drainage system constructed for the first time in South Korea to prevent urban flooding. Experiments were preformed for 55 scenarios, of which 19 overflows occurred. In addition, the video analysis for the scenarios where the overflow occurred showd that the overflow occurred during the process of exhausting the pressurized air in the facility and the undular bore were moving. Results of this study, it was judge that it would be advantageous to maintain a completely drained or full-pipe condition for stable operation of the Shinwol rainwater storage and drainage system for continuous rainfall in the future. And it is necessary to additional research on the correlation for the magnitude of inflow discharge, overflow and undular bore.

The effect of temperature and storage time on DNA integrity after freeze-drying sperm from individuals with normozoospermia

  • Farzaneh Mohammadzadeh Kazorgah;Azam Govahi;Ali Dadseresht;Fatemeh Nejat Pish Kenari;Marziyeh Ajdary;Rana Mehdizadeh;Roya Derakhshan;Mehdi Mehdizadeh
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.51 no.1
    • /
    • pp.42-47
    • /
    • 2024
  • Objective: This study evaluated the effects of temperature and storage time on the quality and DNA integrity of freeze-dried sperm from individuals with normozoospermia. Methods: Normal sperm samples from 15 men aged 24 to 40 years were studied. Each sample was divided into six groups: fresh, freezing (frozen in liquid nitrogen), freeze-dried then preserved at room temperature for 1 month (FD-1m-RT), freeze-dried then preserved at room temperature for 2 months (FD-2m-RT), freeze-dried then preserved at 4 ℃ for 1 month (FD-1m-4 ℃), and freeze-dried then preserved at 4 ℃ for 2 months (FD-2m-4 ℃). The morphology, progressive motility, vitality, and DNA integrity of the sperm were evaluated in all groups. Results: In all freeze-dried groups, sperm cells were immotile after rehydration. The freeze-dried groups also showed significantly less sperm vitality than the fresh and frozen groups. Significantly more morphological sperm abnormalities were found in the freeze-dried groups, but freeze-drying did not lead to a significantly higher DNA fragmentation index (DFI). The DFI was significantly higher in the FD-2m-RT group than in the other freeze-dried groups. Conclusion: The freeze-drying method preserved the integrity of sperm DNA. The temperature and duration of storage were also identified as factors that influenced the DFI. Accordingly, more research is needed on ways to improve sperm quality in the freeze-drying process.

Analysis on User Expectation and Satisfaction Toward Public Community Centers and the State of Use as Public Service Facilities (공공서비스시설로서의 구민회관에 대한 사용자 이용현황과 요구도 및 만족도 분석)

  • Lee, So-Young;Lee, Jin-Young
    • Journal of the Korean housing association
    • /
    • v.19 no.4
    • /
    • pp.31-39
    • /
    • 2008
  • The physical environment is one of several service characteristics that are important contributors to service quality. As far as public service buildings, public community facilities serve as arenas for education, social interaction, leisure, and health activities for community districts. The purpose of this study was to investigate the physical state of public community facilities and use of public community facilities in Seoul and Suwon and to identify expectations of users toward the physical environment and service aspects. Site visits to four public community facilities were conducted and surveys were distributed for this study, with one hundred ninety two questionnaires analyzed. Results suggest that in order to provide more equal benefits and service to the public, cities should provide several smaller instead of one large complex community facility. Additionally, facility users indicated large gaps between their expectations and the current state of facilities due to lack of storage, noise and difficulty of use. In general, physical characteristics should be improved rather than employee's attitudes and service behaviors, resulting in greater service quality.

Treatment of residues of excavated carcasses burials (가축매몰지 소멸시 잔존물 처리방안)

  • Kim, Geonha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.3
    • /
    • pp.269-277
    • /
    • 2018
  • Burials for the rapid disposal of carcasses have diverse and profound effects on the rural living condition, natural environment, and local economy throughout construction, management and final destruction of burials. In this study, possible residue excavated from standard burials, storage using FRP (Fiberglass Reinforced Plastic) tanks, and microbial-treated burials are characterized as carcasses, contaminated soil by leachate, and wasted plastic film. Treatment technologies for volume reduction of the residue including composting, rendering, and thermal hydrolysis were investigated. If the solid and liquid residues generated during volume reduction treatment are directly transferred to the environmental facilities, it may cause disorder due to high concentrations of organics, antibiotics, and lipid. Benefits and drawbacks of composting as a volume reduction techniques are extensively investigated. We also discussed that proper treatment of excavated soils and the reusing the treated soil as agricultural purpose. For the protection of public health and worker's hygiene, treatment criteria including produced residue qualities, and quality standards for the treated soil as agricultural use are required. In addition, Scientific manual for the proper treatment of residues is required. It is necessary to consider the establishment of a pretreatment facility to the occurrence of large-scale residue treatment.

Optimal Determination of Pipe Support Types in Flare System for Minimizing Support Cost (비용 최소화를 위한 플래어 시스템의 배관 서포트 타입 최적설계)

  • Park, Jung-Min;Park, Chang-Hyun;Kim, Tea-Soo;Choi, Dong-Hoon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.4
    • /
    • pp.325-329
    • /
    • 2011
  • Floating, production, storage and offloading (FPSO) is a production facility that refines and saves the drilled crude oil from a drilling facility in the ocean. The flare system in the FPSO is a major part of the pressure relieving system for hydrocarbon processing plants. The flare system consists of a number of pipes and complicated connection systems. Decision of pipe support types is important since the load on the support and the stress in the pipe are influenced by the pipe support type. In this study, we optimally determined the pipe support types that minimized the support cost while satisfying the design constraints on maximum support load, maximum nozzle load and maximum pipe stress ratio. Performance indices included in the design constraints for a specified design were evaluated by pipe structural analysis using CAESAR II. Since pipe support types were all discrete design variables, an evolutionary algorithm (EA) was used as an optimizer. We successfully obtained the optimal solution that reduced the support cost by 27.2% compared to the initial support cost while all the design requirements were satisfied.