• Title/Summary/Keyword: stopping times

Search Result 76, Processing Time 0.02 seconds

Analysis of Holdup Characteristics of Large and Small Bubbles in Three-Phase Fluidized Beds by using a Dynamic Gas Disengagement Method (삼상유동층에서 동력학적 기체유출 측정방법에 의한 큰 기포와 작은 기포의 체류량 특성 해석)

  • Lim, Hyun Oh;Lim, Dae Ho;Seo, Myung Jae;Kang, Yong;Jung, Heon;Lee, Ho Tae
    • Korean Chemical Engineering Research
    • /
    • v.49 no.5
    • /
    • pp.605-610
    • /
    • 2011
  • Phase holdup characteristics of relatively large and small bubbles were investigated in a three-phase(gasliquid-solid) fluidized bed of which diameter was 0.105 m(ID) and 2.5 m in height, respectively. Effects of gas(0.01~0.07 m/s) and liquid velocities(0.01~0.07 m/s) and particle size($0.5{\sim}3.0{\times}10^{-3}m$) on the holdups of relatively large and small bubbles were determined. The holdups of two kinds of bubbles in three phase fluidized beds were estimated by means of static pressure drop method with the knowledge of pressure drops corresponding to each kind of bubble, respectively, which were obtained by dynamic gas disengagement method. Dried and filtered air which was regulated by gas regulator, tap water and glass bead of which density was $2500kg/m^3$ were served as a gas, a liquid and a fluidized solid phase, respectively. The two kinds of bubbles in three-phase fluidized beds, relatively large and small bubbles, were effectively detected and distinguished by measuring the pressure drop variation after stopping the gas and liquid flow into the column as a step function: The increase slope of pressure drop with a variation of elapsed time was quite different from each other. It was found that the holdup of relatively large bubbles increased with increasing gas velocity but decreased with liquid velocity. However, the holdup showed a local minimum with a variation of size of fluidized solid particles. The holdup of relatively small bubbles increased with an increase in the gas velocity or solid particle size, while it decreased slightly with an increase in the liquid velocity. The holdups of two kinds of bubbles were well correlated in terms of operating variables within this experimental conditions, respectively.

A Study on the Domestic Small Package Express Service′s Competitive Power Improvement Plan at EC Times (전자상거래 시대 국내 택배업의 경쟁력 향상 방안에 관한 연구)

  • 박영태;정종식
    • Proceedings of the Korean DIstribution Association Conference
    • /
    • 2002.05a
    • /
    • pp.31-59
    • /
    • 2002
  • Recently there are many changes of logistics environment Such as integrated logistics information system, the rapid growth of the domestic and international small package express service and third party logistics with Electronic Commerce. At this time it is very important to deliver to customers the goods sold through EC speedy, accurately and safely. That is to say, the role of small package express service is very important at EC times. The bottlenecks of small package express service in the circumstances of EC are the weakness of EC operating company and small package express service provider the shortage of distribution centre and cargo terminal, the shortage of skilled man with related small package express service etc. So, I suggested that for activation of EC it is necessary to strengthen the strategic alliances, introduce GPS and use the third party logistics positively in the side of small package express service provider. And it is necessary to prepare for the settlements of traffic problems, support the introduction of integrated logistics service, logistics information system, deregulate restriction such as weight limit of vehicles in the side of the government. And to government support throughout extending nation's SOC, deregulation, support to small package express service terminal, permit to stopping & parking in downtown, abolishing a no passing zone, permit to being employed foreigner. Also this service involves ensuring that the product will arrive when wanted, and in an undamaged condition.

  • PDF

Real-time Body Surface Motion Tracking using the Couch Based Computer-controlled Motion Phantom (CBMP) and Ultrasonic Sensor: A Feasibility Study (CBMP (Couch Based Computer-Controlled Motion Phantom)와 초음파센서에 기반한 실시간 체표면 추적 시스템 개발: 타당성 연구)

  • Lee, Suk;Yang, Dae-Sik;Park, Young-Je;Shin, Dong-Ho;Huh, Hyun-Do;Lee, Sang-Hoon;Cho, Sam-Ju;Lim, Sang-Wook;Jang, Ji-Sun;Cho, Kwang-Hwan;Shin, Hun-Joo;Kim, Chul-Yong
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.27-34
    • /
    • 2007
  • Respiration sating radiotherapy technique developed In consideration of the movement of body surface and Internal organs during respiration, is categorized into the method of analyzing the respiratory volume for data processing and that of keeping track of fiducial landmark or dermatologic markers based on radiography. However, since these methods require high-priced equipments for treatment and are used for the specific radiotherapy. Therefore, we should develop new essential method whilst ruling out the possible problems. This study alms to obtain body surface motion by using the couch based computer-controlled motion phantom (CBMP) and US sensor, and to develop respiration gating techniques that can adjust patients' beds by using opposite values of the data obtained. The CBMP made to measure body surface motion is composed of a BS II microprocessor, sensor, host computer and stopping motor etc. And the program to control and operate It was developed. After the CBMP was adjusted by entering random movement data, and the phantom movements were acquired using the sensors, the two data were compared and analyzed. And then, after the movements by respiration were acquired by using a rabbit, the real-time respiration gating techniques were drawn by operating the phantom with the opposite values of the data. The result of analysing the acquisition-correction delay time for the data value shows that the data value coincided within 1% and that the acquistition-correction delay time was obtained real-time $(2.34{\times}10^{-4}sec)$. And the movement was the maximum movement was 6 mm In Z direction, In which the respiratory cycle was 2.9 seconds. This study successfully confirms the clinical application possibility of respiration gating techniques by using a CBWP and sensor.

  • PDF

The Comparison of Absolute Dose due to Differences of Measurement Condition and Calibration Protocols for Photon Beams (6MV 광자선에서 측정 조건의 변화와 측정법의 차이에 의한 절대 선량값의 비교)

  • 김회남;박성용;서태석;권수일;윤세철
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.87-102
    • /
    • 1997
  • The absolute absorbed dose can be determined according to the measurement conditions; measurement material, detector, energy and calibration protocols. The purpose of this study is to compare the absolute absorbed dose due to the differences of measurement condition and calibration protocols for photon beams. Dosimetric measurements were performed with a farmer type PTW and NEL ionization chambers in water, solid water, and polystyrene phantoms using 6MV photon beams from Siemens linear accelerator. Measurements were made along the central axis of 10cm $\times$ 10cm field size for constant target to surface distance of 100cm for water, solid water and polystyrene phantom. Theoretical absorbed dose intercomparisons between TG21 and IAEA protocol were performed for various measurement combinations of phantom, ion chamber, and electrometer. There were no significant differences of absorbed dose value between TG21 and IAEA protocol. The differences between two protocols are within 1% while the average value of IAEA protocol was 0.5% smaller than TG21 protocol. For the purpose of comparison, all the relative absorbed dose were nomalized to NEL ion chamber with Keithley electrometer and water phantom, The average differences are within 1%, but individual discrepancies are in the range of - 2.5% to 1.2% depending upon the choice of measurement combination. The largest discrepancy of - 2.5% was observed when NEL ion chamber with Keithley electrometer is used in solid water phantom. The main cause for this discrepancy is due to the use of same parameters of stopping power, absorption coeficient, etc. as used in water phantom. It should be mentioned that the solid water phantom is not recommended for absolute dose calibration as the alternative of water, since absorbed dose show some dependency on phantom material other than water. In conclusion, the trend of variation was not much dependent on calibration protocol. However, it shows that absorbed dose could be affected by phantom material other than water.

  • PDF

Muscle Stiffness and Elasticity of Masticatory Muscles on Gum Chewing (껌씹기가 저작근의 경도와 탄성도에 미치는 효과)

  • Won, Tae-Hee;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.4
    • /
    • pp.421-429
    • /
    • 2007
  • Some researchers suggested that tactile sensor system would be useful in evaluating masticatory muscles of TMD patients, but there were few studies on the effects of chewing with time. The aim of this study was to investigate the change of elasticity and stiffness for masseter and temporal muscles of normal subjects before, during and after gum chewing and to obtain the baseline data for further researches on the elasticity and stiffness for masticatory muscles of TMD patients. Stiffness and elasticity of their anterior temporalis and inferior masseter muscle were measured bilaterally by a tactile sensor system. Each subject was instructed to sit on a chair for evaluation of masticatory muscles. Before operating the sensor, the thickest skin area over anterior temporalis and inferior masseter muscles were selected as the points to be pressed by a tactile sensor, and marked with a pen. While the teeth of subjects were lightly contacted, the probe of the tactile sensor was placed perpendicularly over the marked point over the skin, followed by computer-controlled movement including gently pressing straight down on the muscle for a second and retracting. All subjects were instructed to chew gum (Excellent Breath, Taiyo Co., Japan) bilaterally with a velocity of 2 times per second for 40 minutes after the first measurement had been performed for the baseline data of all subjects. The measurements had been repeated during chewing with 10 minutes of interval and continued for 40 minutes with same interval after chewing. Resultantly, the decrease of elasticity and the increase of stiffness in masticatory muscles can be seen significantly within 10 minutes after chewing and those were maintained during chewing without significant change with chewing time. The elasticity of muscles was recovered within 10 minutes after stopping chewing, but the stiffness was recovered more lately than elasticity by about 10 minutes. Based on these results, it can be concluded that elasticity and stiffness of muscles would be good indicators to evaluate the masticatory muscles objectively, when more supported by further researches.

Situation of Fertilizer Industry in Korea (비료산업(肥料産業)의 현황(現況)과 문제점(問題点))

  • Lee, Yun Hwan
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.15 no.1
    • /
    • pp.34-48
    • /
    • 1982
  • 1. Production and consumption of chemical fertilizers in Korea could be divided into five different phases of total imports, setting up fertilizer plants, self-sufficiency in production, net export, and diversification in compound fertilizers. Currently the nation has production capacity of 800 thousand M/T of nitrogen, 400 thousand M/T of phosphate ($P_2O_5$) and 200 thousand M/T of potash ($K_2O$). 2. Yearly consumption increased every year, since 1964, 28,000 M/T N, 7,700 M/T $P_2O_5$, and 7,500 M/T $K_2O$ until 1972, when the increase jumped by eight times for $P_2O_5$ and seven times for $K_2O$ for the following 3 years in anticipation of their short supply. Now total consumption has been more or less stabilized at the level of 450 thousand M/T N, 220 thousand M/T $P_2O_5$ and 180 thousand M/T $K_2O$ for the last 7 years. 3. Current operation rate of fertilizer plants is around 80% throughout the whole industry, after going through several different levels depending on demand at times. 4. Fertilizer export started in 1967 and reached a peak of 150 thousand nutrient ton in 1972, about 20% of total production, before temporarily stopping due to over-demand for next three years. The export resumed again in 1976 rise to the all time high of 670 thousand nutrient ton in 1980, almost half of total production, and then started to decline due to higher price of petroleum since then. 5. The decline in fertilizer export appears to be accelerated because several countries, in South-Eastern Asia, traditional export market for Korean fertilizers, started to build their own plants, since 1980, based on their raw materials of especially petroleum. 6. Current consumption in Korea is about 30 nutrient Kg per 10a, equivalent to that in Western European countries, partly due to new high-yielding rice varieties and extensive cultivation of fruit trees and vegetables. Additional fertilizer demand in future can be anticipated in reclaimed land for growing grass and forestry.

  • PDF