• Title/Summary/Keyword: stone masonry

Search Result 71, Processing Time 0.021 seconds

Vulnerability curves of masonry constructions Algiers case study

  • Djaalali, F.;Bensaibi, M.;Bourahla, N.;Davenne, L.
    • Structural Engineering and Mechanics
    • /
    • v.42 no.5
    • /
    • pp.609-629
    • /
    • 2012
  • This study deals with the assessment of low and mid rise multi-story buildings made of stone and /or brick, composite steel and masonry slabs from the sixties, known to be vulnerable to seismic hazard using the "vulnerability index" method based on buildings survey following Ain Temouchent (1999) and Boumerdes (2003) earthquakes, from where vulnerability curves are constructed using the translation method. The results obtained for the case study confirm what has been observed in situ.

Determination of mortar strength using stone dust as a partially replaced material for cement and sand

  • Muhit, Imrose B.;Raihan, Muhammad T.;Nuruzzaman, Md.
    • Advances in concrete construction
    • /
    • v.2 no.4
    • /
    • pp.249-259
    • /
    • 2014
  • Mortar is a masonry product which is matrix of concrete. It consists of binder and fine aggregate and moreover, it is an essential associate in any reinforced structural construction. The strength of mortar is a special concern to the engineer because mortar is responsible to give protection in the outer part of the structure as well as at a brick joint in masonry wall system. The purpose of this research is to investigate the compressive strength and tensile strength of mortar, which are important mechanical properties, by replacing the cement and sand by stone dust. Moreover, to minimize the increasing demand of cement and sand, checking of appropriateness of stone dust as a construction material is necessary to ensure both solid waste minimization and recovery by exchanging stone dust with cement and sand. Stone dust passing by No. 200 sieve, is used as cement replacing material and retained by No. 100 sieve is used for sand replacement. Sand was replaced by stone dust of 15%, 20%, 25%, 30%, 35%, 40%, 45% and 50% by weight of sand while cement was replaced by stone dust of 3%, 5%, and 7% by weight of cement. Test result indicates that, compressive strength of specimen mix with 35% of sand replacing stone dust and 3% of cement replacing stone dust increases 21.33% and 22.76% respectively than the normal mortar specimen at 7 and 28 days while for tensile it increases up to 13.47%. At the end, optimum dose was selected and crack analysis as well as discussion also included.

Computational Modelling Method by Using the Natural Frequencies of Five-Story Stone Pagoda in Chongnimsa Site (고유진동수를 이용한 정림사지 5층 석탑의 구조모델)

  • Lee, Sung-Min;Lee, Ki-Hak;Park, Sun-Woo;Suh, Man-Chul;Lee, Chan-Hee
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.5
    • /
    • pp.67-74
    • /
    • 2008
  • Multi-layered stone masonry monuments, such as stone pagoda can be modeled as a multi-degrees of freedom system. The dynamic behavior of these structures are mainly influenced by contour condition of contacting surface of stones. In this case the mass of the system can be easily estimated, mean while the estimation of stiffness at junction is not simple. In this paper a method for estimating the spring constant at the contacting surface of stone in proposed. This paper describes a method of computational modelling technique for structural analysis of stone pagodas using measurement of natural frequency and eigenvalue analysis. For this purpose Five story stone pagoda in Cchongnimsa site was selected as a model.

  • PDF

Strengthening techniques for masonry structures of cultural heritage according to recent Croatian provisions

  • Hadzima-Nyarko, Marijana;Ademovic, Naida;Pavic, Gordana;Sipos, Tanja Kalman
    • Earthquakes and Structures
    • /
    • v.15 no.5
    • /
    • pp.473-485
    • /
    • 2018
  • The buildings of architectural and cultural heritage are mostly built with stone or brick wall elements, which are connected using limestone or limestone cement mortar, without a full knowledge of the mechanical properties of masonry structures. The compatibility of heritage masonry buildings with valid technical specifications and the rules for earthquake resistance implies the need for construction work such as repairs, strengthening or reconstruction. By strengthening the masonry buildings, ductility and bearing capacity are increased to a level, which, in the case of the earthquake design, allows for some damage to happen, however the structure retains sufficient usability and bearing capacity without the possibility of collapse. Comparison between traditional and modern techniques for seismic strengthening of masonry buildings is given according to their effects, benefits and disadvantages. Recent Croatian provisions provided for heritage buildings enabling deviation of technical specifications are discussed.

Seismic fragility of regular masonry buildings for in-plane and out-of-plane failure

  • Karantoni, Fillitsa;Tsionis, Georgios;Lyrantzaki, Foteini;Fardis, Michael N.
    • Earthquakes and Structures
    • /
    • v.6 no.6
    • /
    • pp.689-713
    • /
    • 2014
  • The seismic vulnerability of stone masonry buildings is studied on the basis of their fragility curves. In order to account for out-of-plane failure modes, normally disregarded in past studies, linear static Finite Element analysis in 3D of prototype regular buildings is performed using a nonlinear biaxial failure criterion for masonry. More than 1100 analyses are carried out, so as to cover the practical range of the most important parameters, namely the number of storeys, percentage of side length in exterior walls taken up by openings, wall thickness, plan dimensions and number of interior walls, type of floor and pier height-to-length ratio. Results are presented in the form of damage and fragility curves. The fragility curves correspond well to the damage observed in masonry buildings after strong earthquakes and are in good agreement with other fragility curves in the literature. They confirm what is already known, namely that buildings with stiff floors or higher percentage of load-bearing walls are less vulnerable, and that large openings, taller storeys, larger number of storeys, higher wall slenderness and higher ratio of clear height to horizontal length of walls increase the vulnerability, but show also by how much.

DYNAMIC CHARACTERISTICS OF ANCIENT MASONRY CASTLE WALLS

  • SungMinLee;SooGonLee
    • Journal of the Korean Geophysical Society
    • /
    • v.6 no.2
    • /
    • pp.71-77
    • /
    • 2003
  • Generally the dynamic characteristics of stone wall structures depend on several factors such as contact, the type of interlocking bonding stones, and the filling materials. This paper describes a non-destructive technique for diagnosis of historic masonry stone structures using the measurement of natural frequency technique. For this purpose, the castle wall of Nag-An Folk Town located in Sunchon, Korea was selected as a model. The Nag-An Town Castle is one of the well maintained historical remains constructed in the Chosun Kingdom of Korea. The construction started in 1397 A.D and was finished in 1626 A.D. The non-mortar castle wall is 1470m long and the average height is 4m with a width of 3 4m. The exterior of the wall is bonded with 1 2 m rectangular rough-faced stone and the inside of the wall is filled with gravel. The traditional village still remains inside the Nag-An Town Castle, and they have a regional food festival every October. Transverse vibrations were measured at 8 points around the castle. The measured natural frequency of the first mode was 26Hz 41Hz, and the shear modulus of filling material was 2.142 x $10^3$ ~ 8.915 x $10^3$kgf/$cm^2$ . With these results, it may be assumed that the filling material is gravel or a sand-gravel mixture. It is expected that the information provided by this paper will be useful for addressing the maintenance problems of the old castle walls.

  • PDF

Structural Characteristics Analysis of Stone Contact Surface according to Surface Roughness and Filling Material of Stone Pagoda Structure (석탑구조물의 표면거칠기 및 충전재에 따른 석재접촉면의 구조특성 분석)

  • Kim, Ho-Soo;Kim, Dong-Kwan;Lee, Seung-Hee;Kim, Derk-Moon;Jo, Sang-Sun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.6
    • /
    • pp.19-27
    • /
    • 2018
  • The stone pagoda structure is treated as a discontinuous masonry structure, and the contact surface characteristics between stones is a very important factor in the discontinuum behavior analysis. So, it is necessary to find out material and structural characteristics of stone contact surface to perform the structural analysis for safety evaluation. Accordingly, it is important to analyze the material properties of stone surface and secure the structural characteristics through various contact surface states. Therefore, in this study, various test specimens applying the filler between the surface roughness and the stone in the contact surface treatment technique of the stone pagoda were manufactured, and compression test and shear test were carried out. Also, we analyzed the material and structural characteristics of the stone contact surface through the comparison of experimental results.

Gross dynamic failure of toppling block structures

  • Wilson, James F.
    • Structural Engineering and Mechanics
    • /
    • v.8 no.5
    • /
    • pp.491-504
    • /
    • 1999
  • The initiation of toppling is explored for a uniform stack of blocks that rotates slowly about its mid-base. As the stack passes through its vertical position ($\theta$=0), it is in free-fall rotation, and a critical inclination angle ${\theta}_c$ is reached at which the toppling stack "fails" or begins to crack or separate. For tall stacks (high aspect ratios), two modes of failure are hypothesized, for which the dynamic failure analyses are shown to correlate with experimental results. These block failure modes are similar to those observed for tall, toppling masonry structures with weak binding material between their brick or stone blocks.