• Title/Summary/Keyword: stirring effect

Search Result 196, Processing Time 0.025 seconds

A Study on the curvature Effect of microchannel within Electroosmotic Flow (전기삼투 유동 중 마이크로 채널 내 곡률 변화에 따른 혼합특성에 대한 연구)

  • Heo, Hyeung-Seok;Suh, Yong-Kweon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.107-110
    • /
    • 2005
  • In this study a newly designed and electro-osmotic micro-mixer is proposed. This design is comprised of a channel and metal electrodes attached in the local side wall surface, To investigate the flow patterns a numerical method is employed. To obtain the flow patterns numerical computation are performed by using a commercial code, CFD-ACE. The fluid-flow solutions are then cast into studying the characteristics of stirring with aid the Mixing index. Focus is given the effect on the electro osmotic flow characteristics under the curvature variation in the microchannel with the local of the electric field

  • PDF

Quantification of the Mixing Effect by Using the Method of Material-Stretching Mapping (물질신장 사상법에 의한 혼합효과의 정량화)

  • Suh Y. K.
    • Journal of computational fluids engineering
    • /
    • v.9 no.4
    • /
    • pp.20-33
    • /
    • 2004
  • In this study a stretching-mapping method is proposed for calculating the materials' stretching exponents, which are to be used in quantification of the mixing effect. In this method, the mapping tensor associated with the deformation of each fluid material is first obtained. Then deformations of a lot of materials are obtained by applying the mapping tensor. The local stretching rates and their space-average values are next computed with the mapped deformations. Application to a simple time-periodic flow within a cavity shows that the method is indeed effective compared with the conventional method; i.e. the mapping method is fast and yields the same results as the conventional one.

A NUMERICAL STUDY ON FLOW AND STIRRING CHARACTERISTICS IN A MICROCHANNEL WITH PERIODIC ARRAY OF CROSS BAFFLES (엇갈림 배플 구조의 마이크로 채널 내 유동 및 혼합 특성에 관한 수치해석적 연구)

  • Heo, S.G.;Kang, S.M.;Suh, Y.K.
    • Journal of computational fluids engineering
    • /
    • v.11 no.4 s.35
    • /
    • pp.101-106
    • /
    • 2006
  • In the microfluidic devices the most important thing is mixing efficiency ol various fluids. In this study a newly designed miler is proposed to enhance the mixing effect with the purpose to apply it to microchannel mixing in a short future. This design is composed of a channel with cross baffles periodically arranged on the both bottom and top surfaces ol the channel. To obtain the yow patterns, the numerical computation was performed by using a commercial code, ANSYS CFX 10.0. To evaluate the mixing performance, we computed Lyapunov exponent and obtained Poincare sections. it was shown that our design provides the excellent mixing effect.

Synthesis of $(ZrSiO_4)$ Powders by the Sol-Gel Process -Effect of the Milling- (졸-겔법에 의한 지르콘$(ZrSiO_4)$ 분말 합성 -재분쇄(Milling)에 대한 효과-)

  • 신용철;신대용;한상목;남인탁
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.7
    • /
    • pp.853-857
    • /
    • 1995
  • ZrSiO4 powders were prepared from partially hydrolyzed solution of Si(OC2H5)4 and ZrOCl2.8H2O solution by the sol-gel method and formation rate of ZrSiO4 on the reaction parameter was investigated. In order to prepare homogeneous ZrSiO4 precursor gels, the H2O/Si(OC2H5)4 molar ratio of about 2, the pH of the ZrOCl2.8H2O solution fo about 4 and stirring time of the mixed solutions of about 2 hrs were appropriate. Formation of temperature of ZrSiO4 reduced about 15$0^{\circ}C$ by milling and formation of ZrSiO4 at 1300~135$0^{\circ}C$ showed an accelerative increase through the hedvall effect by silica.

  • PDF

Effect on Copper Recovery by Ultrasonic Energy during Cementation Reaction from Copper-contained Waste Etching Solution (구리 함유 폐에칭액의 시멘테이션 반응 시 구리 회수에 미치는 초음파 에너지의 영향)

  • Kim, Boram;Jang, Dae-Hwan;Kim, Dae-Weon;Chae, Byung-Man;Lee, Sang-Woo
    • Resources Recycling
    • /
    • v.31 no.4
    • /
    • pp.34-39
    • /
    • 2022
  • In this study, effects of ultrasonic energy on the cementation reaction and copper recovery rate were investigated for different types of iron samples, such as plate, chip, and powder, for recovering copper from waste etchant, which contained ~3.5% copper. The cementation reaction using the ultrasonic energy was more effective than the simple stirring reaction, with the former exhibiting a high copper recovery rate than the latter for the same time interval. When cementation was performed for 25 min with ultrasonic treatment, rather than simple stirring, the copper recovery rate of the plate, chip, and powder improved from 7.0% to 12.0%, 14.0% to 46.1%, and 41.9% to 77.2%, respectively. Therefore, the use of ultrasonic energy could detach the copper recovered by the cementation reaction from the surface of the iron samples, thereby increasing the copper recovery rate. Owing to the use of ultrasonic energy, the copper recovery rate increased by 2-6 times, and the recovered copper exhibited a decreased particle size compared to that obtained via simple stirring.

Coagulation Control of High Turbid Water Samples Using a Streaming Current Control System (유동흐름 전류계를 이용한 정수장 고탁도 유입수 응집 제어 방법에 대한 연구)

  • Nam, Seung-Woo;Jo, Byung-Il;Kim, Won-Kyong;Zoh, Kyung-Duk
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.2
    • /
    • pp.128-135
    • /
    • 2012
  • Objectives: This study was aimed at determining the optimum coagulation dosage in a high turbid kaolin water sample using streaming current detection (SCD) as an alternative to the jar test. Methods: SCD is able to optimize coagulant dosing by titration of negatively charged particles. Kaolin particles were used to mimic highly turbid water ranging from 50 to 600 NTU, and polyaluminum chloride (PAC, 17%) was applied as a titrant and coagulant. The coagulation consisted of rapid stirring (5 min at 140 rpm), reduced stirring (20 min at 70 rpm), and settling (60 min). To confirm the coagulation effect, a jar test was also compared with the SCD titration results. Results: SCD titration of kaolin water samples showed that the dose of PAC increased as the pH rose. However, supernatant turbidity less than 1 NTU after coagulation was not achieved for high turbid water by SCD titration. Instead, a conversion factor was used to calculate the optimum PAC dosage for high turbid water by correlating a jar test result with that from an SCD titration. Using this approach, we were able to successfully achieve less than 1 NTU in treated water. Conclusions: For high turbid water influent in a water treatment plant, particularly during summer, the application of SCD control by applying a conversion factor can be more useful than a jar test due to the rapid calculation of coagulation dosage. Also, the interpolation of converted PAC dose could successfully achieve turbidity in the treated water of less than 1 NTU. This result indicates that an SCD system can be effectively used in a water treatment plant even for high turbid water during the rainy season.

Flow Analysis of the Environmental Chemical Reaction Processes at Power Plant in accordance with the Baffle Structure

  • Jeong, Yeon-Tae;Hur, Kwang-Beom;Gil, Joon-Woo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.3
    • /
    • pp.433-436
    • /
    • 2016
  • In the area of environmental chemistry of power plant, flow analysis of the reactor with built-in impeller is a very important part from the perspective of the improvement of the efficiency of the entire process. As a wide range of methods are being proposed for the analysis of the flow pattern within the reactor, this study analyzed the flow within the reactor according to the baffle structure (height) installed on the internal wall of the reactor in order to improve the reaction efficiency through the inducing of the up and down stirring with the reactor. As the results of the execution of the flow analysis for each of a diverse range of cases by utilizing the Computational Fluid Dynamics (CFD) method, it was possible to confirm that the flow is markdely improved by inducing the up and down stirring among the reactants within the reactor if the baffle is elevated to the level below the water surface. In particular, as the results of the analysis of the general cases in which the baffle is elevated all 4 steps and the cases in which the baffle is elevated only 2 steps, elevating the baffle only 2 steps achieve the same effect as the elevating of the baffle by 4 steps. Therefore, it was possible to expect to improve the efficiency with out the need to increase the use of electric power substantially if the outcomes of this study is applied to the actual sites of power plants in the future.

Determination of Non-Steroidal Anti-Inflammatory Drugs in Human Urine Sample using HPLC/UV and Three Phase Hollow Fiber-Liquid Phase Microextraction (HF-LPME)

  • Cha, Yong Byoung;Myung, Seung-Woon
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.11
    • /
    • pp.3444-3450
    • /
    • 2013
  • Three phase hollow fiber-liquid phase microextraction (HF-LPME), which is faster, simpler and uses a more environmentally friendly sample-preparation technique, was developed for the analysis of Non-Steroidal Anti-Inflammatory Drugs (NSAIDs) in human urine. For the effective simultaneous extraction/concentration of NSAIDs by three phase HF-LPME, parameters (such as extraction organic solvent, pH of donor/acceptor phase, stirring speed, salting-out effect, sample temperature, and extraction time) which influence the extraction efficiency were optimized. NSAIDs were extracted and concentrated from 4 mL of aqueous solution at pH 3 (donor phase) into dihexyl ether immobilized in the wall pores of a porous hollow fiber, and then extracted into the acceptor phase at pH 13 located in the lumen of the hollow fiber. After the extraction, 5 ${\mu}L$ of the acceptor phase was directly injected into the HPLC/UV system. Simultaneous chromatographic separation of seven NSAIDs was achieved on an Eclipse XDB-C18 (4.6 mm i.d. ${\times}$ 150 mm length, 5 ${\mu}m$ particle size) column using isocratic elution with 0.1% formic acid and methanol (30:70) at a HPLC-UV/Vis system. Under optimized conditions (extraction solvent, dihexyl ether; $pH_{donor}$, 3; $pH_{acceptor}$, 13; stirring speed, 1500 rpm; NaCl salt, 10%; sample temperature, $60^{\circ}C$; and extraction time, 45 min), enrichment factors (EF) were between 59 and 260. The limit of detection (LOD) and limit of quantitation (LOQ) in the spiked urine matrix were in the concentration range of 5-15 ng/mL and 15-45 ng/mL, respectively. The relative recovery and precision obtained were between 58 and 136% and below 15.7% RSD, respectively. The calibration curve was linear within the range of 0.015-0.96 ng/mL with the square of the correlation coefficient being more than 0.997. The established method can be used to analyse of NSAIDs of low concentration (ng/mL) in urine.

Development of Automatic Rewetting System for Rough Rice Stored in Round Steel Bin with Stirring Device -Adsorption characteristics of rough rice- (원형철제빈용 벼 자동흡습장치 개발에 관한 연구(I) -벼의 흡습특성-)

  • Kim, J. Y.;Keum, D. H.;Kim, H.;Park, S. H.
    • Journal of Biosystems Engineering
    • /
    • v.26 no.5
    • /
    • pp.469-474
    • /
    • 2001
  • Milling the rice with low moisture requires more energy, produces more cracked rice, and results in reducing taste of cooked rice. Accordingly, it is necessary to add moisture to the rice with low moisture to obtain optimum moisture level for milling and taste of rice. This study was performed to evaluate the influence of initial moisture content and absorption rate on rice crack, milling energy and whiteness of milled rice and to obtain the information for design of rewetting system mounted on stirring device in grain bin. The tests were conducted for the four levels of initial moisture content in the range of 11.4 to 14.5%(w.b.) and six levels of absorption rate in the range of 0.04 to 1.0%, w.b./hr. In the case of lower moisture content below 12%(w.b.), crack ratios of brown rice were remarkably high regardless of initial moisture contents. Therefore, it was found that rough rice below 12%(w.b.) in initial moisture content could not rewetted by spraying water without crack generation of low level. Absorption rate must be below 0.3%, w.b./hr to maintain crack ratio increase of less than 1% regardless of initial moisture contents. In the case of allowable crack ratio increase of 2% and 5%, it was found that the maximum absorprion rate was respectively 0.6%, w.b./hr and 1.0%, w.b./hr in the initial moisture content of above 13.5%(w.b.). Rewetting the rough rice in moisture content of 11.4 to 14.5%(w.b.) to 14.3 to 16.9%(w.b.) decreased milling energy consumption by 15.9 to 22.3%. The effect of energy saving was higher in the samples of higher initial moisture content. Whiteness of milled rice was decreased by 0.5 to 1.5.

  • PDF

Preparation of UV Curable Anti-Glare Coating Films Using Micrometer-Sized Silica Particles (마이크로미터 크기의 실리카 입자를 이용한 UV 경화형 눈부심 방지 코팅 필름 제조)

  • Kim, Tae Hyoung;Song, Ki Chang
    • Korean Chemical Engineering Research
    • /
    • v.59 no.2
    • /
    • pp.165-173
    • /
    • 2021
  • Anti-glare (AG) coating films are applied to various display fields such as liquid crystal displays, LED lighting, and touch panels. In this study, micrometer-sized silica particles were added as fillers in the UV-curable coating solutions to provide anti-glare effect. During this process, the effects of the particle size, content, stirring time, and mixing ratio of silica particles of different sizes were investigated on the haze values and visible light transmittance of the coating films. As a result, as the size of the silica particles increased and the content of the silica particles increased, the haze values increased, but the visible light transmittance decreased. On the other hand, the stirring time did not significantly affect the haze value and transmittance of coating films. In addition, as the mixing ratio of large-sized silica particles increased, the haze value increased, but on the contrary, the visible light transmittance decreased.