• Title/Summary/Keyword: stimulator

Search Result 332, Processing Time 0.021 seconds

Mechanism of Increased Adrenergic Activities in Hypertension Induced by Chronic Inhibition of NOS (NOS만성억제로 인한 고혈압에서 아드레날린성 활성증가기전)

  • 정국현;이석용
    • YAKHAK HOEJI
    • /
    • v.45 no.1
    • /
    • pp.85-92
    • /
    • 2001
  • Nitric oxide is a tonically produced vasodilator that maintains blood pressure in the normal animal. The chronic inhibition of nitric oxide synthase (NOS) elicits the hypertension in rats. However, the mechanism of hypertension induced by chronic inhibition of NOS is not clear. Thus, to clarify the mechanism of the occurance of hypertension, the changes in $\alpha$-adrenergic systems in rats treated with NOS inhibitors for 21 days were examined. Chronic administration of L-NAME significantly increased in the basal blood pressure, but chronic administration of 7-nitroindazole did not. Phenylephrine and G-protein stimulator elicited the more potent contraction in the aorta of the L-NAME-induced hypertensive rats. However when the contractile responses by phenylephrine and G-protein stimulator were calculated the proportion to the contraction by 25 mM KCL, there was no difference between the vehicle-treated rats and the L-NAME-treated rats. The density of $\alpha$-adrenergic receptors in aortic tissue was not changed by the chronic inhibition of NOS. These results suggest that hypertension induced by chronic inhibition of NOS is due to the inhibition of eNOS and the increased responses to the adrenergic drugs are due to the changes of the intracellular contactile mechanism of aortic tissue rather than the changes of receptor density.

  • PDF

Simulation Application for Functional Electrical Stimulator (기능적 전기 자극 시뮬레이션 응용프로그램)

  • Jeon, Hyo Chan
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.1
    • /
    • pp.59-64
    • /
    • 2016
  • In this study, the application was developed for the simulation of functional electrical stimulation. It functions to calculate the electrical energy which is transmitted to the patient, to visualize the electrical stimulation waveform, Therapy, Burst and Pulse section as setup of time period requested. The application was verified by comparing the oscilloscope and the graph of the application. XML schema was developed to utilize the contents of simulation which consist of the standard codes that are identified by OID. Using the application, medical experts will be able to research and share the contents of simulation.

Design Concept of DCS Stimulator for Shin-kori #3, 4 NSSS Control System (신고리 #3, 4호기 NSSS 제어계통 Stimulation 설계 개념)

  • Bae, Byung-Hwan;Ko, Do-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.305-306
    • /
    • 2007
  • 본 논문은 차세대 원전 신고리 #3, 4호기 NSSS(Nuclear Steam Supply System) 제어계통의 검증시스템을 개발하기 위한 설계개념에 관한 것이다. 차세대 원전 신고리 #3, 4호기는 KHNP(Korea Hydro & Nuclear Power Co., Ltd.)가 개발한 APR1400(Advanced Power Reactor 1400 [MWe])을 적용하는 최초의 원자력 발전소이다. APR1400은 3세대 원자력발전소로 인정받고 있으며, APR1400 원자력발전소의 안전한 운영을 위하여 I&C(Instrumentation and Control)시스템이 디지털 표준 플랫폼으로 설계되었다[2]. 특히, 차세대 원전 신고리 #3, 4호기의 비안전계통(제어 감시 및 경보계통)은 WEC (Westinghouse Electric Company)의 DCS(Distributed Control System) 상용 단일 플랫폼으로 구성될 예정이다. 우리는 신고리 #3, 4호기의 제어계통 중에서 NSSS(Nuclear Steam Supply System) 제어계통의 검증시스템을 개발하기 위하여 Stimulated Simulator의 방법론을 적용하여 "Simulator"라는 설계 개념을 정립하였다. 현재 원자력발전소 NSSS 제어계통의 DCS Stimulator 개발을 위하여 차세대 원전 신고리 #3, 4호기에 시설될 WEC의 DCS와 Simulation 서버 그리고 I/O 설비를 구축 중에 있으며, 원자력발전소 현장 기기 모델링 소프트웨어와 I/O 설비간의 인터페이스를 위한 동신 소프트웨어도 개발하고 있다.

  • PDF

In vitro Interaction of Recombinantly Expressed Kringle 5 (rK5) with Ras Guanine Nucleotide Dissociation Stimulator-like Factor (Rgl2)

  • Lee, Jung-Whoi;Kim, Sun-Hee;Park, Yong-Sung;Woo, Je-Wan;Lim, Dong-Yeol;Lee, Kyung-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.12
    • /
    • pp.1863-1868
    • /
    • 2004
  • Kringle 5 (K5), located outside of angiostain (K1-4) in human plasminogen, displays more potent antiangiogenic activity on endothelial cell proliferation than angiostatin itself. Using a yeast two-hybrid system in vivo, we have recently identified Rgl2 (guanine nucleotide dissociation stimulator (RalGDS)-like factor 2) as a binding protein of human K5. In order to confirm in vitro protein interaction between K5 and Rgl2, we developed bacterial recombinant expression systems for them. K5 and Rgl2 proteins were expressed in high yields and purified into pure forms with His tags and GST fusion, respectively. GST-pull down experiments clearly demonstrated that K5 interacts specifically with Rgl2 in vitro. These results indicate that Rgl2 functions as a receptor protein for K5 in vitro as well as in vivo, leading to anti-angiogenesis through regulating Ras signaling pathways.

Role of G-protein in the Contraction of Rabbit Trachealis Muscle (토끼 기관평활근 수축에서 G Protein의 역할)

  • Jung, Jin-Sup;Hwang, Tae-Ho;Lee, Sang-Ho
    • The Korean Journal of Physiology
    • /
    • v.24 no.2
    • /
    • pp.353-362
    • /
    • 1990
  • Fluoride (F-), a known stimulator of G-protein, induced strong contraction in rabbit trachealis muscle. $AlCl_3\;(5{\sim}20\;{\mu}M)$, which is required for G-protein stimulation by $F^-$, potentiated the contractile response to $F^-$. $Ca^{2+}-removal$ and verapamil, a calcium channel blocker, inhibited the fluoroaluminate-induced contraction. Fluoroaluminate increased $^{45}Ca$ influx in the absence and presence of verapamil. In heparin-loaded muscle high $K^+-induced$ contraction was not affected, but acetylcholine and fluoroaluminate-induced contractions were inhibited. The fluoroaluminate-induced contraction was partially relaxed by isoproterenol, a stimulator of adenylate cyclase. Pertussis toxin partially inhibited fluoroaluminate-induced contraction and potentiated isoproterenol-induced relaxation in the presence of fluoroaluminate, but had no effect on acetylcholine-induced contraction and the isoproterenol-induced relaxation in the presence of acetylcholine. These results suggest that fluoroaluminate has the ability to stimulate at least two putative G-proteins in rabbit trachealis muscle; One causes $Ca^{2+}$ influx through the potential-operated $Ca^{2+}$ channel and the other induces intracellular $Ca^{2+}$ release by the increase of inositol-1, 4, 5-triphosphate.

  • PDF

Development of Programmable Nerve Stimulator ( I ) - Implementation of the Nerve Stimuli Waveform Generator using the Microprocessor - (프로그램 가능한 신경 자극기 개발 ( I ) - 마이크로프로세서를 이용한 신경자극 파형 발생기 구현 -)

  • Kim, K.W.;Eum, S.H.;Lee, S.Y.;Jang, Y.H.;Jun, K.R.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.260-265
    • /
    • 1996
  • The purpose of this study was to implemented a general purpose programmable nerve stimulator system as a research tool for studying psychophysiological performance associated with various stimulation waveform. This system is composed of hardware and software, the former are the personal computer(180586) and control unit(one-chip microprocessor, D/A converter, digital output), the latter are programmed in VISUAL BASIC and ASSEMBLY Which are programmed for the programmable nerve stimuli pattern editor and communication interface, waveform preprocessing, and stimuli generator. The control unit which is entrolled by the personal computer is capable of delivering the programmable nerve stimuli waveform. This system has research potential for determining the effect of various neuromuscular blockade in alternated physiological stat is.

  • PDF

Pulsed Electromagnetic Field Stimulators Efficacy for Noninvasive Bone Growth in Spine Surgery

  • Fiani, Brian;Kondilis, Athanasios;Runnels, Juliana;Rippe, Preston;Davati, Cyrus
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.4
    • /
    • pp.486-494
    • /
    • 2021
  • The growth of pulsed electromagnetic field (PEMF) therapy and its progress over the years for use in post-operative bone growth has been revolutionary in its effect on bone tissue proliferation and vascular flow. However, further progress in PEMF therapy has been difficult due to lack of more evidence-based understanding of its mechanism of action. Our objective was to review the current understanding of bone growth physiology, the mechanism of PEMF therapy action along with its application in spinal surgery and associated outcomes. The authors of this review examined multiple controlled, comparative, and cohort studies to compare fusion rates of patients undergoing PEMF stimulation. Examining spinal fusion rates, a rounded comparison of post-fusion outcomes with and without bone stimulator was performed. Results showed that postoperative spinal surgery PEMF stimulation had higher rates of fusion than control groups. Though PEMF therapy was proven more effective, multiple factors contributed to difficulty in patient compliance for use. Extended timeframe of treatment and cost of treatment were the main obstacles to full compliance. This review showed that PEMF therapy presented an increased rate of recovery in patients, supporting the use of these devices as an effective post-surgical aid. Given the recent advances in the development of PEMF devices, affordability and access will be much easier suited to the patient population, allowing for more readily available treatment options.

Development of Descending Thoracic Aortomyoplasty for Cardiac Bioassist (심장보조를 위한 흉부대동맥 근성형술 개발(예비 동물실험))

  • 오중환;박승일;김은기;김영호;류기홍;이상헌;원주호;서재정
    • Journal of Chest Surgery
    • /
    • v.33 no.6
    • /
    • pp.469-475
    • /
    • 2000
  • Background: Thoracic aortomyoplasty is one of the surgical treatment for heart failure and has advantages over artificial heart or intraaortic balloon pumps. It uses autogenous skeletal muscles and solves problems such as energy source. However its use in clinical settings has been limited. This preliminary study was designed to develop surgical technique and to determine the effect of acute descending thoracic aortomyoplsty. Material and Method: Thirteen adult Mongrel dogs were used. The left latissimus dorsi muscle was wrapped around the descending aorta under general anesthesis. Swan-Ganz and microtipped Millar catheter were used for the hemodynamics and endocaridial viability ratio. Data were collected with myostimulator on and off in normal hearts and the ischemic hearts. Result: In normal hearts, the mean aortic diastolic pressure increased from 72$\pm$15mmHg at baseline to 78$\pm$13mmHg with stimulator on. Coronary perfusion pressure increased from 61$\pm$11mmHg to 65$\pm$9mmHg. Diastolic time increased from 0.288$\pm$0.003 msec to 0.290$\pm$0.003msec. Systolic time decreased from 0.164$\pm$0.002msec to 0.160$\pm$0.002 msec. Endocardial viability ratio increased from 1.21$\pm$0.22 to 1.40$\pm$0.18. In ischemic hearts, mean aortic diastolic pressure incrased from 56$\pm$21mmHg at baseline to 61$\pm$15mmHg with stimulator on. Coronary perfusion pressure increased from 48$\pm$17mmHg to 52$\pm$15mmHg. Diastolic time increased from 0.290$\pm$0.003 msec to 0.313$\pm$0.004msec. Systolic time decreased from 0.180$\pm$0.002 msec to 0.177$\pm$0.003 msec. Endovascular viability ratio increased from 0.9$\pm$0.31 to 1.1$\pm$0.31. The limited number of cases ruled out the statistic significance. Conclusion: Descending thoracic aortomyoplasty is a simple operation designed to use patient's own skeletal muscles. It trends to increase diastolic augmentation and coronary perfusion pressure. Modification of surgical technique and stimulator protocol would maximize the effect to assist the heart.

  • PDF

Development of RF Stimulating Protocol for Effective Heat-Stimulus in Subcutaneous Tissue (피하에 효과적인 열 자극을 위한 고주파 자극 프로토콜 개발)

  • Myoung, Hyoun Seok;Lee, Dae Won;Kim, Han Sung;Lee, Kyoung Joung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.10
    • /
    • pp.194-201
    • /
    • 2012
  • Moxibustion is utilized not only to cure disease but also to increase immunity. However, it may lead to undesired effects including severe pains(blisters and burns) because of the difficulty of controlling heat intensity. To overcome these problems we developed the RF heat stimulation system which can control stimulus. Also, we developed the RF stimulation protocol for effective heat transfer in subcutaneous tissue of rabbit. RF stimulator consists of a medical RF capacitive heating device, isolation probe, isolation plate, negative pressure control part and temperature measurement part. For the designed stimulus protocol, we measured the temperature distribution on epidermis and in subcutaneous(5mm, 10mm) area of rabbit during moxibustion. A stimulation protocol was designed by controlling the ON/OFF duty ratio, repeating number, and energy of applied pulse to get the temperature distribution similar with that by moxibustion. In results, the correlation coefficients between temperature distribution by moxibustion and that of stimulator were 95% and 91% from 5mm and 10mm thick respectively. However, temperature distribution on epidermis by stimulator was remarkably lower than that of the moxibustion. Finally, the RF stimulation system showed that it can not only transfer effectively heat similar with moxibustion to the subcutaneous area, but also the influence by unwanted side effects can be minimized.

Development of Closed-loop Control Type FES System for Restoration of Gait in Patients with Foot Drop (족하수 환자의 보행보조를 위한 피드백 제어형 전기자극기 개발)

  • 정호춘;임승관;이상세;진달복;박병림
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.183-190
    • /
    • 1999
  • The purpose of this study was to develop a portable and convenient closed-loop contrel type electrical stimulator for patients with foot drop. This system restores walking movement as well as prevents from atrophy or necrosis of lower limb muscles and increases blood circulation in hemiplegic patients caused by traffic accident, industrial disaster or stoke. This system detects the changes of the ankle joint angle during walking, and then controls the stimulus intensity automatically to maintain the programmed level of the ankle joint angle. Also, this automatic system controls the stimulus intensity which is affected by increased electrode impedance resulting from long time use. The system detects the joint angle by an optical sensor and includes modified PID control which adjusts the stimulus intensity if the joint angle deviates from the preset value. Stimulus parameters are 30~80 volt, 40 Hz, and 0.2 ms. The system was applied to five hemiplegic patients for 42 days. Duration of stimulation was 15 min/day for the first week and then the duration was gradually increased to 30, 60, 90 and 120 min/day. The muscle force was increased up to 29.7%, muscle fatigue was decreased compared with the level before stimulation and the pattern of locomotion was improved. These results suggest that the electrical stimulator with closed-loop control type is more convenient and effective in restoration of locomotion of patients with foot drop than open-loop system.

  • PDF