• Title/Summary/Keyword: sterilizing method

Search Result 45, Processing Time 0.024 seconds

Effects of Sterilization for Quality Control and Content of baicalin in Scutellariae Radix (멸균법에 따른 황금의 미생물학적 품질보증과 바이칼린 함량에 미치는 영향)

  • Jeong, Choon-Sik
    • Korean Journal of Pharmacognosy
    • /
    • v.36 no.3 s.142
    • /
    • pp.220-223
    • /
    • 2005
  • The purposes of this study was to develop the best one among the methods using dry heat, gamma irradiation and alcohol gas, to sterilize Scutellariae Radix selected based on high frequency of circulation between merchants and high susceptibility to microbial contamination, through comparing these methods in terms of the followings; ⅰ) the efficacy of sterilization in comparison with cost, and ⅱ)the alteration of chemical components of these herbal medicines. The results of this study will be taken advantage of establishment of the maximum limit of microorganism contaminated in herbal medicines. From the results of this study we conclude the followings: ⅰ) The sterilizing method using dry heat may be inappropriate, because it seriously changed their color and morphology which is an essential criterion to estimate a measure of quality between merchants and consumers, although it effectively got rid of contaminated microorganism and did not alter major components, baicalin; ⅱ) The sterilizing method using gamma irradiation may be appropriate, because it showed a strong sterilizing effect, and no alteration of chemical components, color and morphology; ⅲ)The sterilizing method using alcohol gas may also be appropriate, because it had a similar effects as in the case of gamma irradiation. Collectively, we suggest that appropriate sterilizing methods to guarantee the microbial quality of this herbal medicine may be those using gamma irradiation and alcohol gas.

Effect of Sterilizing Method on the Quality Change of Iron Fortified Market Milk during Storage (살균방법이 철분강화 우유의 저장중 품질변화에 미치는 영향)

  • 김윤지;김기성
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.28 no.4
    • /
    • pp.755-759
    • /
    • 1999
  • To evaluate the effect of sterilizing method on the quality of iron fortified market milk, HTST(high temperature, short time) or LTLT(low temperture, long time) method was adopted after addition of 100ppm ferrous sulfate, ferric citrate, ferric ammonium citrate, or ferrous lactate in market milk. Sterilized iron fortified market milk was stored at 4oC and then pH, lipid oxidation, color change, and sensory quality were observed. The range of pH change in iron fortified market milk sterilized by HTST or LTLT was 6.51~6.74. The order of pH was control>ferric ammonium citrate>ferrous lactate>ferrous sulfate>ferric citrate. Oxygen consumption of ferric ammonium citrate and ferric citrate was lower than ferrous lactate and ferrous sulfate. This trend was same in HTST and LTLT method, but generally oxygen consumption was lower in iron fortified market milk sterilized by LTLT method than by HTST. In total color change, ferrous lactate treatment was closer to control than other treatments. Also sensory characteristics of ferrous lactate treatment was showed better quality than other treatment. From these results, LTLT method was more suitable than HTST method for iron fortified market milk and ferrous lactate was comparably suitable among iron salts used in this study.

  • PDF

A Study on Sterilization Characteristics of Elliptical Reactor by Using Xenon Flashlamp and Photocatalyst (Xenon flashlamp와 광촉매를 이용한 타원형 반응기의 살균 특성에 관한 연구)

  • Lee, Dong-Gil;Hong, Ji-Tae;Choi, Kyoung-Hwa;Cha, Jae-Ho;Kim, Hong-Ju;Kim, Hee-Je
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.559-565
    • /
    • 2009
  • In this paper, we invented a new and unique technique for the sterilization of Escherichia coli(E. coli) in polluted water. We applied a rich ultra-violet(UV) light from pulsed xenon flashlamp and photocatalyst(TiO2) to sterilize E. coli in polluted water. This method based on the use of UV light and photocatalyst is eco-friendly and does not cause secondary pollution. The proposed elliptical reactor is able to concentrate on quartz sleeve coated TiO2 or general quartz sleeve. The primary objective of our research was to determine the important parameters such as pulse repetition rate and input voltage and to know on the sterilizing efficiency of quartz sleeve coated TiO2 and general quartz sleeve. We obtained to achieve 99.999% sterilization in as little as 6 pulses at 800V in case of quartz sleeve coated Ti02, and 10 pulses at 800V in case of general quartz sleeve for 5 minutes. Although transmitted light of quartz sleeve coated TiO2 is deceased, the sterilizing efficiency is increased by 40% than general quartz sleeve. The reason of high sterilizing efficiency is that generated hydroxyl radical(OH) by photocatalyst and is able to concentrate light at a focus by using elliptical reactor.

Research on Ultrasonic Sterilization Effect of Treatment Equipments (초음파 처리조의 구조에 따른 살균효과 연구)

  • Lee, Yanglae;Kim, Hyunse;Baek, Minhyuck
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.5
    • /
    • pp.818-823
    • /
    • 2013
  • In the process of sterilization during the manufacture of beverages, both the treatment time and the temperature influence the beverage taste and flavor. Therefore, to improve the beverage quality, a nonthermal sterilization method is preferred to a high-temperature one. A nonthermal method, ultrasonic treatment by shock waves from cavitation, has been known to have a sterilizing effect. In this study, to observe the effect of ultrasonic frequency and treatment time on beverage quality, batch type ultrasonic equipment was fabricated and tested. Further, to evaluate the applicability of this ultrasonic method to an in-situ process, flow type ultrasonic heptagonal equipment was fabricated and then used to perform a sterilization experiment. Subsequently, the sterilizing effect was measured under ultrasonic and low-temperature ($55^{\circ}C$) treatments. Based on the obtained results, ultrasonic sterilization technology that can be applied for treatments at flow rates of up to 3 L/min was developed.

A Study on Levels of Awareness of Nosocomial Infection and Management Practices by Operating Room Nurses (수술실 간호사의 병원감염관리에 대한 인지도와 실천정도에 관한 연구)

  • Kim Kyoung-Hee;Choi Mi-Hye;Kang Mi-Kyoung
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.11 no.3
    • /
    • pp.327-334
    • /
    • 2004
  • Purpose: This study was done to examine the awareness and management practice of operating room nurses, to prevent nosocomial infection, to identify problems and to propose solutions. Method: The research tools used were the hospital infection control guideline and a modified version of the measurment tools used in the study of Cho (1998). The questionnaire consisted of questions on hand washing, personal hygiene and clothes control, cleaning and environment control, sterilizing supplies and disposal of contaminated materials. The collected data were analysed with the SPSS program. Results: The mean score for domain-specific awareness of nosocomial infection control was 4.81 out of a possible 5 points. The highest score was for sterilizing supplies and disposal of contaminated materials. The mean score for domain-specific practices of nosocomial infection control was 4.40, out of a possible 5 points. Sterilizing supplies and disposal of contaminated materials had the highest scores. The mean score for awareness in all domains was higher than mean score for practice. Among the general characteristics of the nurses, high awareness was found only in the provision of infection control guidelines and it had shown statistically significant difference. Examination of relation of general characteristics to practice showed that for age, career, the provision of infection control guidelines, and experience in infection control education there were statistically significant differences in the scores. For the relation between awareness of nosocomial infection control and practice, positive correlation was found in all domains, thus high awareness leads to high practice. Conclusion: Considering the result of this research, plans are needed that promote virtual practice of hospital infection control.

  • PDF

Sterilization Effects on Mulberries (Morus alba L.) Washed with Electrolyzed Water and Chlorine Dioxide (전해수와 이산화염소수 세척에 따른 뽕나무 오디(Morus alba L.)의 살균효과)

  • Teng, Hui;Lee, Sun-Ho;Lee, Won-Young
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.23 no.5
    • /
    • pp.654-661
    • /
    • 2013
  • The current research is designed to analyze sterilization effects on mulberries in terms of storage temperature and storage period after treating with tap water (TW), electrolyzed water (EW) and aqueous chlorine dioxide ($ClO_2$). The treated $ClO_2$ concentrations are 10, 50, 100 and 200 ppm. In each concentration, the mulberries are soaked for 30 seconds respectively. The sterilization effects are being compared at room temperature ($25^{\circ}C$) and at $4^{\circ}C$, respectively. And the enzyme activity related to quality is also being investigated and analyzed about for browning inhibition effects. Microbial sterilizing power increases more in treating plots with EW and $ClO_2$ than treating plot with TW. Futhermore sterilizing power of $ClO_2$ increased sharply on high concentration treatment plot as well. Sterilization effects of $ClO_2$ during storage time are better at cold temperature. Pictures taken from scanning electron microscope reveal that there are no microbes in sterilizing solutions treatment plots. From measurement of the enzyme activity, it is concluded that activities decrease more in sterilizing solutions treatment plots as comparing with TW treated plot during the time. The amount of total polyphenolics decrease with the time passing and EW and $ClO_2$ treatment shows less contents than TW treatment. Thus, EW and $ClO_2$ treatment of mulberris are considered as method to improve safety by reducing total plate count and to contribute to quality maintenance and to extend storage time.

Energy self-sufficient electrolysis apparatus for sterilization of portable toilet in small vessels (소형선박에 설치 가능한 해상기인 오염원 멸균용 에너지 자급형 전기분해 장치 개발)

  • Oh, Seung-Won;Hahn, Min-Soo;Choi, Hae-Wook
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.48 no.3
    • /
    • pp.269-276
    • /
    • 2012
  • Marine caused pollution occurs mostly near coastal area and its main cause was known to be human feces issued from small vessels. To sterilize liquid pollutants from portable toilets of small vessels, an electrolysis treatment is judged to be the most economic and stable method considering an environment of its use. In this paper, we presents an electrolysis apparatus which is the most appropriate for sterilizing pollutants from portable toilets of small vessels and derives the minimum operating time of the apparatus for sterilizing norovirus which is a main target of marine caused pollution sources. In order to utilize renewable energy, we designed an apparatus which generates a renewable energy from solar cells. As a result, we could confirm the applicability of the proposed system with the results from experiments in three cases of different weather conditions.

A Study on Antibacterial Assesment of High Efficiency Antibacterial Air Filter (고효율 항균 필터의 항균력 평가에 관한 연구)

  • 권혁구;정진도;류해열;정우성;박덕신
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.549-554
    • /
    • 2002
  • Recently, interest in hygiene has been arouse in the health care field. Consequently, Filters with antibacterial agent applied to improve air quality by sterilizing bacteria, fungi, etc. We actually installed antibacterial air filter containing 2.5wt%Ag zeolite on the air intake route to air-conditioner in passenger cu, and evaluated filter's performance on antibacterial effect. By the microbe liquid spattering method, we found that the antibacterial air filter has notably sufficient antibacterial efficiency against standard strains and wild type strains. Antibacterial effect was observed at whole area of filter media by zone of inhibition test. The evaluation of microbe quantity was conducted through mixing dilution plate culture method. In comparison with ordinary filter, the amount of germs attached on antibacterial air filters was larger. The amount of germs attached on ordinary filters was very small since ordinary filters contained less dust. In comparison in antibacterial air filter with thickness, the amount of germs attached on 9mm filter was smaller than that of on 6mm filter. i.e. thicker filter, superior efficiency.

  • PDF

Frequency control method of ozonator power supply (오존발생기 구동장치의 주파수제어에 관한 연구)

  • 최규남
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.4
    • /
    • pp.887-893
    • /
    • 1999
  • The characteristics of ozone generator targeted for air or water sterilizing in the vessel utilizing the surface corona discharge between the electrodes on the ceramic substrate was investigated by using the frequency control method. The frequency control was achieved by controlling the degree of resonance between the secondary winding inductance of transformer and the electrode capacitance of ceramic discharge plate, and the range of control was found to be 5 times of discharge current. This frequency control method showed the efficiency of 28 mP ozone generation and the stability within 3.4 % when the input voltage was varied within 40% range. The frequency control method is regarded to be more efficient way of corona discharge control compared to the conventional on/off control or voltage control methods.

  • PDF

Use of Nisin as an Aid in Reduction of Thermal Process of Bottled Sikhae (Rice Beverage)

  • Yoo, Jin-Young;Kwon, Dong-Jin;Park, Jong-Hyun;Koo, Young-Jo
    • Journal of Microbiology and Biotechnology
    • /
    • v.4 no.2
    • /
    • pp.141-145
    • /
    • 1994
  • Conventional commercial thermal process for preparing Sikhae (Rice beverage) in a hermetically sealed container was evaluated to solve the nutritional deterioration and organoleptic inferiority problem caused by severe heat treatment. A milder thermal process with an aid of Nisin, a GRAS-grade, selectively germicidal compound, was introduced to destroy the putrefactive microorganisms. In this experiment, hot-filling method with Nisin, and thermal processing (at 110$^{\circ}C$ for 15 minutes with Nisin, at 121$^{\circ}C$ for 25 minutes without Nisin) were compared. The quality of Sikhae could be enhanced and over 90% of the thermal process could be conserved by this process in terms of sterilizing value without quality deterioration when processing the bottled Sikhae at 110$^{\circ}$ for 15 minutes $\{(F^{10}{_{121})_{process}=1.54\}$.

  • PDF