• 제목/요약/키워드: stents

검색결과 312건 처리시간 0.026초

Long Term Outcome of In-Stent Stenosis after Stent Assisted Coil Embolization for Cerebral Aneurysm

  • Kim, Sung Jin;Kim, Young-Joon;Ko, Jung Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권5호
    • /
    • pp.536-544
    • /
    • 2019
  • Objective : The objective of this study was to evaluatelong-term radiologic prognosis and characteristics of in-stent stenosis (ISS) after stent assisted coiling (SAC) for cerebral aneurysm and analyze its risk factors. Methods : Radiological records of 362 cases of SAC during 10 years were retrospectively reviewed. Patients were included in this study if they had follow-up angiogram using catheter selected angiography at least twice. All subjected were followed up from 12 months to over 30 months. Of 120 patients, 123 aneurysms were enrolled. Patient data including age, sex, aneurysm size, neck size, procedural complication, kinds of stent, ISS associated symptom, ruptured state, location of ISS, degree of ISS, radiologic prognosis of ISS, follow-up period of time, and medical comorbidities such as hypertension, diabetes mellitus (DM), dyslipidemia, and smoking were collected.Statistical comparisons of group clinical characteristics were conducted for the total population. Results : Among 123 casesof aneurysm, 22 cases (17.9%) of ISS were revealed on follow-up angiography. Multiple stenting was performed in three cases and intra-procedural rupture occurred in two cases. Most cases were asymptomatic and symptomatic stenosis was identified in only one case. Sixteen cases were ruptured aneurysm. Mild stenosis was observed in 11 cases. Moderate stenosis was found in eight cases and severe stenosis was identified in three cases. Mean timing of identification of ISS was 8.90 months. The most common type was proximal type. Most cases were improved or not changed on follow-up angiography. Only one case was aggravated from mild stenosis to occlusion of parent artery. Mean follow-up period was 44.3 months. We compared risk factors and characteristic between ISS group and non-ISS group using univariate analysis. Multiple stenting was performed for three cases (13.6%) of the ISS group and four cases (4.0%) of the non-ISS group, showing no statistical difference between the two groups (p=0.108). Additionally, the proportion of patients who had more than two risk factors among four medical risk factors (hypertension, DM, dyslipidemia, and smoking) was higher in the ISS group than that in the non-ISS group, the difference between the two was not statistically significant either (31.8% vs. 12.9%, p=0.05). Conclusion : Clinical course and long-term prognosis of ISS might be benign. Most cases of ISS could be improved or not aggravated. Control of medical co-morbidity might be important. To the best of our knowledge, our study had more cases with longer follow-up period of time than other reports.

컴퓨터단층 혈관조영술에서 스텐트 사이즈의 정확한 측정을 위한 상대적 측정법의 기초연구 (Fundamental Study of Relative Measurement for Accurate Measurement of Stent Size in Computed Tomography Angiography)

  • 이승영;홍주완;강수미;김수빈;전상훈;허영철
    • 한국방사선학회논문지
    • /
    • 제13권5호
    • /
    • pp.713-720
    • /
    • 2019
  • 본 연구의 목적은 컴퓨터단층 혈관조영술에서 혈관 직경을 정확하게 측정할 수 있는 새로운 측정 방법인 상대적 측정법의 기초연구 자료를 제공하고자 한다. 비이온성 요오드 조영제를 자체 제작한 관류 팬텀에 일정한 속도로 흐르게 한 후 컴퓨터단층 혈관조영술 검사를 시행하였다. 원시 데이터를 얻은 후 다중평면재구성 및 최대강도투사법으로 영상을 재구성하였고 장비 사에서 제공하는 거리측정 장치를 사용하여 팬텀의 직경을 측정하였다. 측정법은 고식적 측정법과 본 연구에서 제안하는 상대적 측정법을 사용하였다. 관류팬텀의 평균 직경은 다중평면재구성기법과 최대강도투사법 모두에서 상대적 측정법이 기존 측정법 보다 실측에 더 가깝게 나타났다(34% VS 24%, p<0.05). 하지만 두 가지 측정법 모두 실측보다 여전히 확대된 결과를 나타내고 있음을 확인하였다. 따라서 상대적 측정 방법에 대한 추가 연구가 필요한 실정이며, 이에 본 연구가 기초 자료를 제공할 수 있을 것이라 사료된다.

Parylene-C 코팅된 의료용 SUS304 소재의 결합력 향상을 위한 플라즈마 처리 효과 (The effect of plasma treatment to improve adhesion strength of parylene-C coated medical grade SUS304)

  • 김동국;송태하;정용훈;강관수;윤덕규;김민욱;우영재;서요한;김경아;노지형
    • 한국표면공학회지
    • /
    • 제55권6호
    • /
    • pp.390-397
    • /
    • 2022
  • Parylene-C which was mainly used for industries such as electronics, machinery and semiconductors has recently been in the spotlight in the medical field due to its properties such as corrosion resistance and biocompatibility. In this study we intend to derive a plan to improve the bonding strength of Parylene-C coating with the SUS304 base material for medical use which can be applied to various medical fields such as needles, micro needles and in vitro diagnostic device sensors. Through plasma pretreatment the bonding strength between Parylene-C and metal materials was improved. It was confirmed that the coated surface was hydrophobic by measuring the contact angle and the improvement of the surface roughness of the sample manufactured through CNC machining was confirmed by measuring the surface roughness with SEM. Through the above results, it is thought that it will be effective in increasing usability and reducing pain in patients by minimizing friction when inserting medical devices and in contact with skin. In addition it can be applied to various application fields such as human implantable stents and catheters, and is expected to improve the performance and lifespan of medical parts.

The Protective Effects of Statins towards Vessel Wall Injury Caused by a Stent Retrieving Mechanical Thrombectomy Device : A Histological Analysis of the Rabbit Carotid Artery Model

  • Lee, Seung Hwan;Shin, Hee Sup;Oh, Inho
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권5호
    • /
    • pp.693-704
    • /
    • 2021
  • Objective : Endovascular mechanical thrombectomy (MT) has been regarded as one of the standard treatments for acute ischemic stroke caused by large vessel occlusion. Despite the wide use of stent retrievers for MT, arterial intimal damage caused when deployed stent is pulled has been a certain disadvantage. We hypothesized that statin could protect and stabilize vessel damage after endovascular MT using a stent retriever. In this animal study, we observed the protective effects of the statins towards MT-induced vessel wall injury. Methods : Twenty-eight carotid arteries of fourteen rabbits were used in the experiments with MT using stent retriever. We divided the rabbits into four groups as follows : group 1, negative control; group 2, positive control; group 3, statin before MT; and group 4, statin after MT. After MT procedures, we harvested the carotid arteries and performed histomorphological and immunohistochemical analyses. Results : In histomorphological analysis with hematoxylin and eosin and Masson's trichrome stain, significant intimal thickening (p<0.05) was observed in the positive control (group 2), compared to in the negative control (group 1). Intimal thickening was improved in the statin-administered groups (groups 3 and 4 vs. group 2, p<0.05). We also observed that statin administration after MT (group 4) resulted in a more effective decrease in intimal thickness than statin administration before MT (group 3) (p<0.05). We performed immunohistochemical analysis with the antibodies for tumor necrosis factor-alpha (TNF-α), cluster of differentiation (CD)11b, and CD163. In contrast to the negative control (group 1), the stained percentage areas of all immunological markers were markedly increased in the positive control (group 2) (p<0.05). Based on statin administration, the percentage area of TNF-α staining was significantly reduced (p<0.05) in group 3, compared to the positive control group (group 2). However, significant differences were not observed for CD11b and CD163 staining. In group 4, no significant differences were observed for TNF-α, CD11b, and CD163 staining (p≥0.05). The differences in the percentage areas of the different markers between the statin-administered groups (groups 3 and 4) were also not revealed. Conclusion : We presented that statin administration before and after MT exerted protective effects towards vessel wall injury. The efficacy of statins was greater post-administration than pre-administration. Thus, statin administration in routine prescriptions in the peri-procedural period is strongly advised.

Optimal Duration of Dual Antiplatelet Therapy after Stent-Assisted Coil Embolization of Unruptured Intracranial Aneurysms : A Prospective Randomized Multicenter Trial

  • Ban, Seung Pil;Kwon, O-Ki;Kim, Young Deok;Kim, Bum-Tae;Oh, Jae Sang;Kim, Kang Min;Kim, Chang Hyeun;Kim, Chang-Hyun;Choi, Jai Ho;Kim, Young Woo;Lim, Yong Cheol;Byoun, Hyoung Soo;Park, Sukh Que;Chung, Joonho;Park, Keun Young;Park, Jung Cheol;Kwon, Hyon-Jo;Korean NeuroEndovascular Society,
    • Journal of Korean Neurosurgical Society
    • /
    • 제65권6호
    • /
    • pp.765-771
    • /
    • 2022
  • Objective : Stent-assisted coil embolization (SAC) has been increasingly used to treat various types of intracranial aneurysms. Delayed thromboembolic complications are major concerns regarding this procedure, so dual antiplatelet therapy with aspirin and clopidogrel is needed. However, clinicians vary the duration of dual antiplatelet therapy after SAC, and no randomized study has been performed. This study aims to compare the safety and efficacy of long-term (12 months) dual antiplatelet therapy and short-term dual antiplatelet therapy (6 months) after SAC for patients with unruptured intracranial aneurysms (UIAs). Methods : This is a prospective, randomized and multicenter trial to investigate the optimal duration of dual antiplatelet therapy after SAC in patients with UIAs. Subjects will receive dual antiplatelet therapy for 6 months (short-term group) or 12 months (long-term group) after SAC. The primary endpoint is the assessment of thromboembolic complications between 1 and 18 months after SAC. We will enroll 528 subjects (264 subjects in each group) and perform 1 : 1 randomization. This study will involve 14 top-performing, high-volume Korean institutions specializing in coil embolization. Results : The trial will begin enrollment in 2022, and clinical data will be available after enrollment and follow-up. Conclusion : This article describes that the aim of this prospective randomized multicenter trial is to compare the effect of short-term (6 months) and long-term (12 months) dual antiplatelet therapy on UIAs in patients undergoing SAC, and to find the optimal duration.

Prophylactic Intraoperative Nasolacrimal Duct Intubation in Surgical Treatment of Facial Fractures-Is There a Role?

  • Teoh, Ryan Liang Wei;Fong, Pei Yuan;Cai, Elijah Zhengyang;Yap, Yan Lin;Hing, Eileen Chor Hoong;Lee, Han Jing;Nallathamby, Vigneswaran;Ong, Wei Chen;Lim, Jane;Sundar, Gangadhara;Lim, Thiam Chye
    • Archives of Plastic Surgery
    • /
    • 제49권2호
    • /
    • pp.195-199
    • /
    • 2022
  • Nasolacrimal duct (NLD) damage is associated in the majority of type II and III naso-orbito-ethmoid (NOE) fractures. Our study aims to investigate the efficacy and safety of prophylactic NLD intubation in the setting of facial fractures, by comparing incidence of postoperative epiphora and wound infection. A retrospective matched control study was conducted on all patients with surgically treated facial fractures from 2008 to 2013 (n=280) (IRB ref number: DSRB 2013/01198). Patients with the following fracture types were included: NOE (n=16), frontal sinus (n=2), Le Fort II/III (n=8), and > 1 type (n=48). All patients in this study were included with the intention to treat. The study group comprised patients who were intubated, while the control group patients were not intubated. Each group had 37 patients matched for age, gender, fracture type, and injury type. A single oculoplastic surgeon skilled in lacrimal surgery performed the procedure for all intubated patients. Patients with more severe and complex facial fractures were intubated with bicanalicular Crawford stents. Postoperative epiphora and infective complications (both facial wound and dacryocystitis) were assessed at 1, 3, 6, and 12 months. There was no significant difference in incidence of either postoperative epiphora (p=0.152) or wound infection (p=0.556) comparing both groups. Reduced incidence of postoperative epiphora in the study group is statistically not significant and does not support the need for prophylactic intubation. If radiographic evidence of NLD disruption or regurgitation seen on syringing on the NLD intraoperatively is present, intubation is safe and efficacious only if performed by an expert.

경미한 증상을 가지는 파열 뇌동맥류의 치료에 있어서 스텐트를 이용한 코일 색전술과 단순 코일 색전술의 비교: 단일 병원 경험 (Comparison of Stent-Assisted Coil Embolization Versus Coil Embolization Alone for Ruptured Cerebral Aneurysms with Mild Symptoms: A Single-Clinic Experience)

  • 임가영;신상훈;이태영;권운정;박병수;권순찬
    • 대한영상의학회지
    • /
    • 제83권4호
    • /
    • pp.887-897
    • /
    • 2022
  • 목적 심각한 증상이 없는 파열된 급성뇌동맥류에서 스텐트를 이용한 코일 색전술 기법의 안전성과 유효성을 평가하고, 지주막하출혈 환자에서 스텐트 자체의 유용성을 평가해 보고자 한다. 대상과 방법 2017년 1월부터 2019년 6월까지 심한 증상이 없는(헌트 앤드 헤스 등급 3 이하) 파열된 뇌동맥류에 대해 코일 색전술로 치료받은 118명의 환자를 대상으로 하였다. 스텐트를 사용한 56명과 스텐트를 사용하지 않은 62명에 대해 시술 이후 합병증, 6개월 수정 랜킨척도, 6개월 영상의학적 결과에 대해 비교하였다. 결과 스텐트를 사용한 군과 스텐트 사용하지 않은 군에서 좋은 임상 결과의 비율(수정 랜킨척도 2 이하)과 출혈성 및 허혈성 합병증의 비율은 유의한 차이를 보이지 않았다. 그러나 스텐트를 사용한 군은 6개월 추적 뇌혈관조영술에서 재개통률이 낮았다(20.0% 대 39.3%, p = 0.001). 결론 심한 증상이 없는(헌트 앤드 헤스 등급 3 이하) 파열된 뇌동맥류의 코일 색전술에서 스텐트의 사용은 임상 결과와 유의한 관련성이 없었다. 스텐트를 사용함으로써 추적 뇌혈관조영술에서 재개통률이 감소하였다.

Usefulness of Silent MRA for Evaluation of Aneurysm after Stent-Assisted Coil Embolization

  • You Na Kim;Jin Wook Choi;Yong Cheol Lim;Jihye Song;Ji Hyun Park;Woo Sang Jung
    • Korean Journal of Radiology
    • /
    • 제23권2호
    • /
    • pp.246-255
    • /
    • 2022
  • Objective: To determine the usefulness of Silent MR angiography (MRA) for evaluating intracranial aneurysms treated with stent-assisted coil embolization. Materials and Methods: Ninety-nine patients (101 aneurysms) treated with stent-assisted coil embolization (Neuroform atlas, 71 cases; Enterprise, 17; LVIS Jr, 9; and Solitaire AB, 4 cases) underwent time-of-flight (TOF) MRA and Silent MRA in the same session using a 3T MRI system within 24 hours of embolization. Two radiologists independently interpreted both MRA images retrospectively and rated the image quality using a 5-point Likert scale. The image quality and diagnostic accuracy of the two modalities in the detection of aneurysm occlusion were further compared based on the stent design and the site of aneurysm. Results: The average image quality scores of the Silent MRA and TOF MRA were 4.38 ± 0.83 and 2.78 ± 1.04, respectively (p < 0.001), with an almost perfect interobserver agreement. Silent MRA had a significantly higher image quality score than TOF MRA at the distal internal carotid artery (n = 57, 4.25 ± 0.91 vs. 3.05 ± 1.16, p < 0.001), middle cerebral artery (n = 21, 4.57 ± 0.75 vs. 2.19 ± 0.68, p < 0.001), anterior cerebral artery (n = 13, 4.54 ± 0.66 vs. 2.46 ± 0.66, p < 0.001), and posterior circulation artery (n = 10, 4.50 ± 0.71 vs. 2.90 ± 0.74, p = 0.013). Silent MRA had superior image quality score to TOF MRA in the stented arteries when using Neuroform atlas (4.66 ± 0.53 vs. 3.21 ± 0.84, p < 0.001), Enterprise (3.29 ± 1.59 vs. 1.59 ± 0.51, p = 0.003), LVIS Jr (4.33 ± 1.89 vs. 1.89 ± 0.78, p = 0.033), and Solitaire AB stents (4.00 ± 2.25 vs. 2.25 ± 0.96, p = 0.356). The interpretation of the status of aneurysm occlusion exhibited significantly higher sensitivity with Silent MRA than with TOF MRA when using the Neuroform Atlas stent (96.4% vs. 14.3%, respectively, p < 0.001) and LVIS Jr stent (100% vs. 20%, respectively, p = 0.046). Conclusion: Silent MRA can be useful to evaluate aneurysms treated with stent-assisted coil embolization, regardless of the aneurysm location and type of stent used.

Effect of Stent Placement on Survival in Patients with Malignant Portal Vein Stenosis: A Propensity Score-Matched Study

  • Dong Jae Shim;Jong Woo Kim;Doyoung Kim;Gi-Young Ko;Dong Il Gwon;Ji Hoon Shin;Yun-Jung Yang
    • Korean Journal of Radiology
    • /
    • 제23권1호
    • /
    • pp.68-76
    • /
    • 2022
  • Objective: Percutaneous portal vein (PV) stent placement can be an effective treatment for symptoms associated with portal hypertension. This study aimed to evaluate the effect of PV stenting on the overall survival (OS) in patients with malignant PV stenosis. Materials and Methods: Two groups of patients with malignant PV stenosis were compared in this retrospective study involving two institutions. A total of 197 patients who underwent PV stenting between November 2016 and August 2019 were established as the stent group, whereas 29 patients with PV stenosis who were treated conservatively between July 2013 and October 2016 constituted the no-stent group. OS was compared between the two groups before and after propensity score matching (PSM). Risk factors associated with OS were evaluated using the Cox proportional hazards model. Procedure-associated adverse events were also evaluated. Results: The stent group finally included 100 patients (median age, 65 [interquartile range, 58-71] years; 64 male). The no-stent group included 22 patients (69 [61-75] years, 13 male). Stent placement was successful in 95% of attempted cases, and the 1- and 2-year stent occlusion-free survival rate was 56% (95% confidence interval, 45%-69%) and 44% (32%-60%), respectively. The median stent occlusion-free survival time was 176 (interquartile range, 70-440) days. OS was significantly longer in the stent group than in the no-stent group (median 294 vs. 87 days, p < 0.001 before PSM, p = 0.011 after PSM). The 1- and 3-year OS rates before PSM were 40% and 11%, respectively, in the stent group. The 1-year OS rate after PSM was 32% and 5% in the stent and no-stent groups, respectively. Anemia requiring transfusion (n = 2) and acute thrombosis necessitating re-stenting (n = 1) occurred in three patients in the stent group within 1 week. Conclusion: Percutaneous placement of a PV stent may be effective in improving OS in patients with malignant PV stenosis.

Improvement in Image Quality and Visibility of Coronary Arteries, Stents, and Valve Structures on CT Angiography by Deep Learning Reconstruction

  • Chuluunbaatar Otgonbaatar;Jae-Kyun Ryu;Jaemin Shin;Ji Young Woo;Jung Wook Seo;Hackjoon Shim;Dae Hyun Hwang
    • Korean Journal of Radiology
    • /
    • 제23권11호
    • /
    • pp.1044-1054
    • /
    • 2022
  • Objective: This study aimed to investigate whether a deep learning reconstruction (DLR) method improves the image quality, stent evaluation, and visibility of the valve apparatus in coronary computed tomography angiography (CCTA) when compared with filtered back projection (FBP) and hybrid iterative reconstruction (IR) methods. Materials and Methods: CCTA images of 51 patients (mean age ± standard deviation [SD], 63.9 ± 9.8 years, 36 male) who underwent examination at a single institution were reconstructed using DLR, FBP, and hybrid IR methods and reviewed. CT attenuation, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and stent evaluation, including 10%-90% edge rise slope (ERS) and 10%-90% edge rise distance (ERD), were measured. Quantitative data are summarized as the mean ± SD. The subjective visual scores (1 for worst -5 for best) of the images were obtained for the following: overall image quality, image noise, and appearance of stent, vessel, and aortic and tricuspid valve apparatus (annulus, leaflets, papillary muscles, and chordae tendineae). These parameters were compared between the DLR, FBP, and hybrid IR methods. Results: DLR provided higher Hounsfield unit (HU) values in the aorta and similar attenuation in the fat and muscle compared with FBP and hybrid IR. The image noise in HU was significantly lower in DLR (12.6 ± 2.2) than in hybrid IR (24.2 ± 3.0) and FBP (54.2 ± 9.5) (p < 0.001). The SNR and CNR were significantly higher in the DLR group than in the FBP and hybrid IR groups (p < 0.001). In the coronary stent, the mean value of ERS was significantly higher in DLR (1260.4 ± 242.5 HU/mm) than that of FBP (801.9 ± 170.7 HU/mm) and hybrid IR (641.9 ± 112.0 HU/mm). The mean value of ERD was measured as 0.8 ± 0.1 mm for DLR while it was 1.1 ± 0.2 mm for FBP and 1.1 ± 0.2 mm for hybrid IR. The subjective visual scores were higher in the DLR than in the images reconstructed with FBP and hybrid IR. Conclusion: DLR reconstruction provided better images than FBP and hybrid IR reconstruction.