• Title/Summary/Keyword: steel-plate energy dissipation connectors

Search Result 6, Processing Time 0.019 seconds

Seismic behavior of energy dissipation shear wall with CFST column elements

  • Su, Hao;Zhu Lihua;Wang, Yaohong;Feng, Lei;Gao, Zeyu;Guo, Yuchen;Meng, Longfei;Yuan, Hanquan
    • Steel and Composite Structures
    • /
    • v.43 no.1
    • /
    • pp.55-66
    • /
    • 2022
  • To develop high-efficiency lateral force resistance components for high-rise buildings, a novel energy dissipation shear wall with concrete-filled steel tubular (CFST) column elements was proposed. An energy dissipation shear wall specimen with CFST column elements (GZSW) and an ordinary reinforced concrete shear wall (SW) were constructed, and experimented by low-cycle reversed loading. The mechanical characteristics of these two specimens, including the bearing capacity, ductility, energy dissipation, and stiffness degradation process, were analyzed. The finite-element model of the GZSW was established by ABAQUS. Based on this finite-element model, the effect of the placement of steel-plate energy dissipation connectors on the seismic performance of the shear wall was analyzed, and optimization was performed. The experiment results prove that, the GZSW exhibited a superior seismic performance in terms of bearing capacity, ductility, energy dissipation, and stiffness degradation, in comparison with the SW. The results calculated by the ABAQUS finite-elements model of GZSW corresponded well with the results of experiment, and it proved the rationality of the established finite-elements model. In addition, the optimal placement of the steel-plate energy dissipation connectors was obtained by ABAQUS.

Seismic behavior of strengthened reinforced concrete coupling beams by bolted steel plates, Part 1: Experimental study

  • Zhu, Y.;Su, R.K.L.;Zhou, F.L.
    • Structural Engineering and Mechanics
    • /
    • v.27 no.2
    • /
    • pp.149-172
    • /
    • 2007
  • An experimental study of five full-scale coupling beam specimens has been conducted to investigate the seismic behavior of strengthened RC coupling beams by bolted side steel plates using a reversed cyclic loading procedure. The strengthened coupling beams are fabricated with different plate thicknesses and shear connector arrangements to study their respective effects on load-carrying capacity, strength retention, stiffness degradation, deformation capacity, and energy dissipation ability. The study revealed that putting shear connectors along the span of coupling beams produces no significant improvement to the structural performance of the strengthened beams. Translational and rotational partial interactions of the shear connectors that would weaken the load-carrying capacity of the steel plates were observed and measured. The hierarchy of failure of concrete, steel plates, and shear connectors was identified. Furthermore, detailed effects of plate buckling and various arrangements of shear connectors on the post-peak behavior of the strengthened beams are discussed.

Numerical investigation on seismic performance of reinforced rib-double steel plate concrete combination shear wall

  • Longyun Zhou;Xiaohu Li;Xiaojun Li
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.78-91
    • /
    • 2024
  • Double steel plate concrete composite shear wall (SCSW) has been widely utilized in nuclear power plants and high-rise structures, and its shear connectors have a substantial impact on the seismic performance of SCSW. Therefore, in this study, the mechanical properties of SCSW with angle stiffening ribs as shear connections were parametrically examined for the reactor containment structure of nuclear power plants. The axial compression ratio of the SCSW, the spacing of the angle stiffening rib arrangement and the thickness of the angle stiffening rib steel plate were selected as the study parameters. Four finite element models were constructed by using the finite element program named ABAQUS to verify the experimental results of our team, and 13 finite element models were established to investigate the selected three parameters. Thus, the shear capacity, deformation capacity, ductility and energy dissipation capacity of SCSW were determined. The research results show that: compared with studs, using stiffened ribs as shear connectors can significantly enhance the mechanical properties of SCSW; When the axial compression ratio is 0.3-0.4, the seismic performance of SCSW can be maximized; with the lowering of stiffener gap, the shear bearing capacity is greatly enhanced, and when the gap is lowered to a specific distance, the shear bearing capacity has no major affect; in addition, increasing the thickness of stiffeners can significantly increase the shear capacity, ductility and energy dissipation capacity of SCSW. With the rise in the thickness of angle stiffening ribs, the improvement rate of each mechanical property index slows down. Finally, the shear bearing capacity calculation formula of SCSW with angle stiffening ribs as shear connectors is derived. The average error between the theoretical calculation formula and the finite element calculation results is 8% demonstrating that the theoretical formula is reliable. This study can provide reference for the design of SCSW.

Parametric study of energy dissipation mechanisms of hybrid masonry structures

  • Gao, Zhenjia;Nistor, Mihaela;Stanciulescu, Ilinca
    • Structural Engineering and Mechanics
    • /
    • v.78 no.4
    • /
    • pp.387-401
    • /
    • 2021
  • This paper provides a methodology to analyze the seismic performance of different component designs in hybrid masonry structures (HMS). HMS, comprised of masonry panels, steel frames and plate connectors is a relatively new structural system with potential applications in high seismic areas. HMS dissipate earthquake energy through yielding in the steel components and damage in the masonry panels. Currently, there are no complete codes to assist with the design of the energy dissipation components of HMS and there have been no computational studies performed to aid in the understanding of the system energy dissipation mechanisms. This paper presents parametric studies based on calibrated computational models to extrapolate the test data to a wider range of connector strengths and more varied reinforcement patterns and reinforcement ratios of the masonry panels. The results of the numerical studies are used to provide a methodology to examine the effect of connector strength and masonry panel design on the energy dissipation in HMS systems. We use as test cases two story structures subjected to cyclic loading due to the availability of experimental data for these configurations. The methodology presented is however general and can be applied to arbitrary panel geometries, and column and story numbers.

Impact response of a novel flat steel-concrete-corrugated steel panel

  • Lu, Jingyi;Wang, Yonghui;Zhai, Ximei;Zhou, Hongyuan
    • Steel and Composite Structures
    • /
    • v.42 no.2
    • /
    • pp.277-288
    • /
    • 2022
  • A novel flat steel plate-concrete-corrugated steel plate (FS-C-CS) sandwich panel was proposed for resisting impact load. The failure mode, impact force and displacement response of the FS-C-CS panel under impact loading were studied via drop-weight impact tests. The combined global flexure and local indentation deformation mode of the FS-C-CS panel was observed, and three stages of impact process were identified. Moreover, the effects of corrugated plate height and steel plate thickness on the impact responses of the FS-C-CS panels were quantitatively analysed, and the impact resistant performance of the FS-C-CS panel was found to be generally improved on increasing corrugated plate height and thickness in terms of smaller deformation as well as larger impact force and post-peak mean force. The Finite Element (FE) model of the FS-C-CS panel under impact loading was established to predict its dynamic response and further reveal its failure mode and impact energy dissipation mechanism. The numerical results indicated that the concrete core and corrugated steel plate dissipated the majority of impact energy. In addition, employing end plates and high strength bolts as shear connectors could prevent the slip between steel plates and concrete core and assure the full composite action of the FS-C-CS panel.

Nonlinear Finite Element Analysis of Considering Interface Behaviors between Steel and Concrete (강-콘크리트 계면파괴에 관한 비선형 유한요소해석)

  • Joo, Young-Tae;Lee, Yong-Hak
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.105-108
    • /
    • 2004
  • In general, the nonlinear behavior of composite structures composing of steel and concrete is analyzed on the basis of the assumption of the perfect bond actions in steel-concrete interface in which the interface slip or separation is not allowed. The assumption is based on the fact that the full interface bond behavior is provided with the mechanical connectors of studs. However, since the number and spacing of the studs are determined by the stress resultants calculated in the interface area, the interface analysis is required to evaluate the stress resultants. This paper describes the nonlinear steel-concrete interface behavior considering the two interface failure mechanisms of slip and separation. Elastoplastic constitutive relation is developed. thru the formulation framework using the two energy dissipation mechanisms. As the result, the steel plate push-out tests sandwitched between concrete blocks are analyzed and compared with the test results with which the good agreements are observed.

  • PDF