• Title/Summary/Keyword: steel-box pedestrian bridge

Search Result 4, Processing Time 0.018 seconds

Reliability-Based Assessment of Safety and Load Carrying Capacity of Steel-Box Pedestrian Bridges (신뢰성에 기초한 강상형 보도육교의 안전도 및 내하력 평가)

  • 조효남;최영민;이은철
    • Computational Structural Engineering
    • /
    • v.10 no.2
    • /
    • pp.189-201
    • /
    • 1997
  • A number of standard type of steel-box pedestrian bridges are constructed in th metropolitan high way or heavy traffic urban area. Although it has the advantage of speedy construction because of its simple structural form and prefabricated erection method, it has been reported that many of these bridges are deteriorated or damaged and thus are in the state such that it would give unsafe and uncomfortable feeling to pedestrians. In the paper, for the realistic assessment of safety and load carrying capacity of deteriorated and/or damaged steel box pedestrian bridges, an interactive non-linear limit state model is formulated based on the von Mises' combined stress yield criterion. It has been demonstrated that the proposed model is effective for the reliability-based safety assessment and load carrying capacity evaluation of steel-box pedestrian bridges. In addition, this study suggests an effective and practical field load test method for pedestrian bridges.

  • PDF

Vibration Serviceability Evaluation of a Single Span Steel-Concrete Composite Foot Bridge under Dynamic Pedestrian Loadings Considering Moving Mass Effect (이동 질량 효과를 고려한 단경간 강합성 보행교의 보행 하중 진동 사용성 평가)

  • Wonsuk Park
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.2
    • /
    • pp.75-83
    • /
    • 2023
  • In this paper, we present the analysis results on the vibration serviceability of a pedestrian bridge considering the effect of pedestrian moving mass inertia. Using dynamic finite element analysis, we considered different walking scenarios, including pedestrian density, walking speed, random walking, and synchronized walking, to analyze the acceleration response of a 40m long single-span bridge with a steel composite box cross section. We showed that the equivalent fixed mass analysis method did not significantly differ from the moving mass analysis in the random walk scenario and a wider frequency excitation band may be useful to consider when evaluating vibration serviceability in a random walk scenario.

Study on the Vibration Control of Footbridge by Using Tuned Mass Damper(TMD) (Tuned Mass Damper(TMD)를 이용한 보도교의 진동제어에 대한 연구)

  • 권영록;최광규
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.6
    • /
    • pp.9-15
    • /
    • 2003
  • This paper describes a vibration control by using tuned mass damper(i.e., TMD) for an existing footbridge. The footbridge is the simple steel box girder bridge with main span length of 47.7m. This bridge has light weight, low damping and the 1st bending frequency of 1.84㎐. Its frequency is close to a walking cycle, which is 2㎐. Therefore the uncomfortable resonant vibrations due to a pedestrian walking have occurred frequently. The vibration control by means of TMD for suppressing the pedestrian induced vibration was conducted. Taking into account economical benefits and the easiness of installation, a compact TMD installed within a handrail was designed. From field tests of the TMD, it was confirmed that the structural damping of the bridge via. the compact TMD was enhanced by 13 times and the resonant vibration due to pedestrian walking was suppressed.

Effective Vibration Control of Existing Footbridge Using Tuned Mass Damper (TMD를 이용한 기존 보도교의 효율적 진동제어)

  • 최석정;유문식;안상구;박찬희
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.263-269
    • /
    • 2003
  • This paper describes the vibration control using a tuned mass damper(TMD) for the existing footbridge. The footbridge connecting driveway to the Stadium is the simple steel box-girder bridge with the main span length of 44.6m. This footbridge has light weight(=25.3kN/m) and pedestrians walking on the footbridge were found to induce resonance at the fundamental mode of the structure, resulting in unacceptable accelerations in it. Taking into account economical and constructional benefits, TMD was designed to damp the vibrations of the modes next to the natural frequency caused by a pedestrian, with a limitation criteria of vertical amplitude. A set of two 500kgf vertical TMDs was manufactured by KR and installed into the railings next to the central section of this footbridge. The installation of TMDs reduced the peak acceleration in the meeting box to less than 90%. It is hoped that the study will present bridge engineers with a measure of retrofitting footbridges to make them more friendly to users.

  • PDF