• 제목/요약/키워드: steel section

Search Result 1,905, Processing Time 0.02 seconds

An Experimental Study on Fine Dust Emissions near Special Modified Asphalt Pavement and Conventional Asphalt Pavement (특수개질 및 일반 아스팔트 포장체 도로변의 미세먼지 발생에 대한 실험적 연구)

  • Tae-Woo Kang;Hyeok-Jung Kim
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.3
    • /
    • pp.282-288
    • /
    • 2023
  • In this study, we analyzed the amount of roadside fine dust generated from newly constructed specially modified asphalt pavement and general asphalt pavement from existing roads. We collected the 1,000 g (100 g/day) of dust samples from the roadside of the express bus terminal and commercial facility area in Chungcheongnam-do's C site at three-day intervals during the summer of 2022 and 2023. The collected samples were separated from fine dust according to size in the 75-150 ㎛ range and, were separated only from Tire and Road Wear Particles through density separation. No.1-3 are general asphalt pavement section as an existing road. Fine dust and Tire and Road Wear Particles in No.1-3 were 24.27 g, 24.36 g, 0.53 g, and 0.53 g, respectively, and the quantitative results for 2022 and 2023 were similar. On the other hand, No.4-6 are newly constructed specially modified asphalt pavement section. Fine dust decreased by 14.8 % and tire and road wear particles decreased by 29.6 % in 2023 compared to 2022 in No.4-6. In addition, according to the results of thermogravimetric analysis, Tire and road wear particles in No.1-3 are tire and road components at 30 % and 70 %, respectively. And Tire and road wear particles in No.4-6 are tire and road components at 35 % and 65 % in 2023, respectively. From these results, it was confirmed that the newly constructed specially modified asphalt pavement can be effective in reducing roadside fine dust and Tire and Road Wear Particles. However, there may be some shortcomings in conclusive research results due to limited space and sample collection period. In the future, we plan to conduct various case studies.

Anti-corrosion properties for cross section of Mg films on galvalume steel coated by PVD process (PVD법에 의해 Mg 코팅된 갈바륨 도금강판의 단면부 내식특성)

  • Park, Jae-Hyeok;Kim, Sun-Ho;Park, Gi-Dong;Jeong, Jae-In;Yang, Ji-Hun;Lee, Gyeong-Hwang;Lee, Myeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.65-65
    • /
    • 2018
  • 갈바륨 도금강판은 알루미늄의 우수한 차폐 특성과 내열성, 열 반사성을 가지며 아연의 희생방식 특성을 겸비하여 동일 부착량의 용융 아연도금 및 알루미늄 도금강판에 비해 우수한 내식성을 나타낸다고 알려져 있다. 또한 이것은 표면이 미려하고 경제성이 높아 건자재 용도로 현재까지도 세계적으로 널리 이용되고 있다. 여기서 지칭하는 바륨 도금강판(galvalume steel)은 아연과 알루미늄 도금강판의 장점을 접목하기 위해 55 Al-43.4 Zn-1.6 Si (wt.%)로 구성되어 개발된 3원계 성분의 합금도금강판이다. 한편, 최근에는 강재의 내식성을 향상시키기 위한 다양한 연구 결과에 의해 Zn-Al-Mg의 3원계 합금도금강판도 개발되어 사용되고 있다. 이것은 기존의 아연도금 강판 보다 10배 정도의 우수한 내식성을 나타내는 것으로 보고되고 있다. 특히, 이것은 도금된 평판부의 내식성은 물론 절단된 도금 단면부의 내식성도 매우 우수하다고 알려져 있다. 그러나 상기한 갈바륨 도금강판의 경우에는 도금된 표면부에 비해 단면부의 내식성이 상대적으로 취약한 것으로 알려져 있다. 따라서 본 연구에서는 갈바륨 도금강판의 내식성을 종합적으로 향상시키기 위하여 이 갈바륨 도금강판 상에 PVD 스퍼터링법에 의해 Mg 코팅막의 제작을 시도하였다. 여기서 Mg 코팅막은 후처리 된 갈바륨 도금강판 상에 Ar 공정압력 2 및 20 mTorr 조건 중 1.5 및 $3{\mu}m$ 두께로 제작하였다. 또한 제작한 코팅막에 대해서는 모폴로지 관찰(SEM) 및 결정구조 분석(XRD)을 하였고, 분극측정, 염수분무 시험(SST) 및 복합부식 시험(CCT)에 의해 표면 및 단면부의 내식성평가를 수행하였다. 또한 여기서는 염수분무 및 복합부식 시험 후의 시험편도 채취 하여 표면 및 단면부위에 대한 원소조성 분석(EPMA)과 결정구조 분석(XRD)을 실시하였다. 이상의 실험 결과에 의하면, 본 실험에서 제작한 Mg 코팅막은 그 두께가 두꺼울수록 표면 Mg 결정립의 크기가 증가하였고, 그 부식속도가 증가하는 경향을 나타내었다. 또한 여기서는 공정압력이 높은 조건에서 제작한 막일수록 Mg(002)면 피크 강도가 감소하고 Mg(101)면 피크의 배향성이 증가하였다. 그때 그 막의 내식성은 향상되는 경향을 나타내었다. 그리고 종합적으로 염수분무 및 복합부식 시험 결과에 의하면 Mg이 코팅된 갈바륨 도금강판은 기존 갈바륨 도금강판 보다 내식성이 현저히 향상되었다. 특히, 단면부 내식성의 경우에는 기존 대비 5배 이상 향상되는 경향을 나타내었다. 여기서 단면부 내식특성 분석을 위한 EPMA 원소조성 분석 결과에 의거하면, 부식 초기에는 마그네슘의 부식생성물에 의해 단면부가 치밀하게 보호되고 있음을 확인할 수 있었다. 그 이후에는 부식이 지속적으로 진행됨에 따라 갈바륨 도금층에서 용출된 알루미늄 및 아연 성분이 마그네슘과 함께 치밀한 부식생성물을 형성하여 단면부를 차폐함에 따라 단면부의 내식성이 크게 향상된 것으로 생각된다. 이러한 부식생성물의 결정구조 분석 결과에 따르면, 염수분무와 복합부식 시험에서는 공통적으로 MgO, $Mg(OH)_2$ 이외에도 Simonkolleite상 등이 형성되었다. 또한 건-습 반복 부식시험인 복합부식시험 후에는 $Mg_5(CO_3)_4(OH)_24H_2O$(Hydromagnesite)상 등이 형성됨을 확인할 수 있었다. 즉, 본 실험에서 후처리된 갈바륨 도금강판 상에 제작한 마그네슘 코팅막의 경우에는 상기와 같은 다양한 부식반응에 의해 표면 및 단면부에 형성된 Mg계 부식생성물과 $Zn_5(OH)_8Cl_2H_2O$(Simonkolleite)상에 의해서 표면은 물론 단면부 내식성이 크게 향상된 것으로 사료된다.

  • PDF

Analysis of Structural Types and Design Factors for Fruit Tree Greenhouses (과수재배용 온실의 구조유형과 설계요소 분석)

  • Nam, Sang-Woon;Ko, Gi-Hyuk
    • Journal of Bio-Environment Control
    • /
    • v.22 no.1
    • /
    • pp.27-33
    • /
    • 2013
  • In order to provide basic data for the development of a controlled environment cultivation system and standardization of the structures, structural status and improvement methods were investigated for the fruit tree greenhouses of grape, pear, and peach. The greenhouses for citrus and grape cultivation are increasing while pear and persimmon greenhouses are gradually decreasing due to the advance of storage facilities. In the future, greenhouse cultivation will expand for the fruit trees which are more effective in cultivation under rain shelter and are low in storage capability. Fruit tree greenhouses were mostly complying with standards of farm supply type models except for a pear greenhouse and a large single-span peach greenhouse. It showed that there was no greenhouse specialized in each species of fruit tree. Frame members of the fruit tree greenhouses were mostly complying with standards of the farm supply type model or the disaster tolerance type model published by MIFAFF and RDA. In most cases, the concrete foundations were used. The pear greenhouse built with the column of larger cross section than the disaster tolerance type. The pear greenhouse had also a special type of foundation with the steel plate welded at the bottom of columns and buried in the ground. As the results of the structural safety analysis of the fruit tree greenhouses, the grape greenhouses in Gimcheon and Cheonan and the peach greenhouses in Namwon and Cheonan appeared to be vulnerable for snow load whereas the peach greenhouse in Namwon was not safe enough to withstand wind load. The peach greenhouse converted from a vegetable growing facility turned out to be unsafe for both snow and wind loads. Considering the shape, height and planting space of fruit tree, the appropriate size of greenhouses was suggested that the grape greenhouse be 7.0~8.0 m wide and 2.5~2.8 m high for eaves, while 6.0~7.0 m wide and 3.0~3.3 m of eaves height for the pear and peach greenhouses.

Changing Aspects of the Wall Types of Hahoe Village (하회마을 담장 형태의 변화양상)

  • Kim, Dong-Hyun;Lee, Won-Ho
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.5
    • /
    • pp.87-96
    • /
    • 2017
  • This study focuses on the Andong Hahoe Village and seeks to identify the shape of the walls since the 1970s. The change of walls can be divided into four periods based on characteristics of materials, shape and distribution. The following is a summary of the results: First, In the 1970s, when Andong Hahoe Village was not designated as a cultural heritage, roof tiles hung on the earthen walls in the middle of the village were major forms. On the outside of the village, rice straw and pine needles were put on the earthen walls or bush clover walls were put in place around if walls were not built. Second, after being designated as a cultural heritage in the 1980s, readjustments for cultural heritages were carried out at the primary stage. However, the distribution of cultural heritages and major changes were not determined at this time since readjustments were mainly focused on the renovation of derelict houses or maintenance of infrastructures. Third, in the past the use of stone bricks for the Hahoe Village site had been difficult, but in the 1990s, replacements with soil-stone walls were identified and the usage of roof tiles increased. The portion of earthen walls, which used to be the major form in the prior era, decreased and this seems to have continued until the 2000s. Fourth, via a field survey, it was found that most of Hahoe village walls consisted of soil cement bricks mixed with cement, steel, lime, gravel. etc. Also, the scope of straw-stricken walls and bush clover walls were reduced to a section of area outside of the village. Fifth, from the 1970s to the present, there were changes to the walls in Hahoe Village including an increase in usages of new materials and an expansion of houses with tiled roofs on top in accordance with the replacement of walls of existing houses. Relevant reasons for this have been identified, such as the fading value of Fungsui(風水) and lack of original records, insufficient awareness and expertise in non-building areas, and the relationship between residents on repairing the wall.

Analysis on the Shear Behavior of Existing Reinforced Concrete Beam-Column Structures Infilled with U-Type Precast Wall Panel (U형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 보-기둥 구조물의 전단 거동 분석)

  • Ha, Soo-Kyoung;Son, Guk-Won;Yu, Sung-Yong;Ju, Ho-Seong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.6
    • /
    • pp.18-28
    • /
    • 2015
  • The purpose of this study is to develop a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were performed on one unreinforced beam-column specimen and two reinforced specimens with U-type precast wall panels. The results were analyzed to find that the specimen with anchored connection experienced shear failure, while the other specimen with steel plate connection principally manifested flexural failure. The ultimate strength of the specimens was determined to be the weaker of the shear strength of top connection and flexural strength at the critical section of precast panel. In this setup of U-type panel specimens, if a push loading is applied to the reinforced concrete column on one side and push the precast concrete panel, a pull loading from upper shear connection is to be applied to the other side of the top shear connection of precast panel. Since the composite flexural behavior of the two members govern the total behavior during the push loading process, the ultimate horizontal resistance of this specimen was not directly influenced by shear strength at the top connection of precast panel. However, the RC column and PC wall panel member mainly exhibited non-composite behavior during the pull loading process. The ultimate horizontal resistance was directly influenced by the shear strength of top connection because the pull loading from the beam applied directly to the upper shear connection. The analytical result for the internal shear resistance at the connection pursuant to the anchor shear design of ACI 318M-11 Appendix-D, agreed with the experimental result based on the elastic analysis of Midas-Zen by using the largest loading from experiment.