• Title/Summary/Keyword: steel plates

Search Result 1,484, Processing Time 0.022 seconds

Effect of Initial Microstructure, Cold Rolling and Temperature on the Spheroidization Rate of Cementite in High Carbon Steel (고탄소강의 구상화속도에 미치는 초기 미세조직, 냉간압연 및 온도의 영향)

  • Kim, J.H.;Ha, T.K.
    • Transactions of Materials Processing
    • /
    • v.22 no.3
    • /
    • pp.158-164
    • /
    • 2013
  • The spheroidization behavior of cementite in a SK85 high carbon steel was investigated in this study. Fine and coarse pearlite microstructures were obtained by appropriate heat treatments according to the TTT diagram of SK85 high carbon steel. Hot rolled plates of SK85 steel were austenitized at $800^{\circ}C$ for 2 hrs and then put directly into a salt bath at either $570^{\circ}C$ or $670^{\circ}C$ to obtain a fine pearlite (FP) structure and a coarse pearlite (CP) structure, respectively. Cold rolling was subsequently conducted on those specimens with reduction ratios from 0.2 to 0.4. Spheroidization heat treatments were conducted at the subcritical temperatures of 600 and $720^{\circ}C$ for 1 to 32 hrs to elucidate the effect of initial microstructures, heat treatment temperature, and cold reduction ratios on the cementite spheroidization rate. Spheroidization proceeded with fragmentation of cementite plates, spheroidization of the cementite platelets, and coarsening consecutively. Mechanical fragmentation of cementite by cold rolling expedited the rate of spheroidization. The spheroidization rate of FP was much more rapid than that of CP and the spheriodization rate increased with increases in the cold reduction ratio.

Structural behaviors of notched steel beams strengthened using CFRP strips

  • Yousefi, Omid;Narmashiri, Kambiz;Ghaemdoust, Mohammad Reza
    • Steel and Composite Structures
    • /
    • v.25 no.1
    • /
    • pp.35-43
    • /
    • 2017
  • This paper presents the findings of experimental and numerical investigations on failure analysis and structural behavior of notched steel I-beams reinforced by bonded Carbon Fiber Reinforced Polymer (CFRP) plates under static load. To find solutions for preventing or delaying the failures, understanding the CFRP failure modes is beneficial. One non-strengthened control beam and four specimens with different deficiencies (one side and two sides) on flexural flanges in both experimental test and simulation were studied. Two additional notched beams were investigated just numerically. In the experimental test, four-point bending method with static gradual loading was employed. To simulate the specimens, ABAQUS software in full three dimensional (3D) case and non-linear analysis method was applied. The results show that the CFRP failure modes in strengthening of deficient steel I-beams include end-debonding, below point load debonding, splitting and delamination. Strengthening schedule is important to the occurrences and sequences of CFRP failure modes. Additionally, application of CFRP plates in the deficiency region prevents crack propagation and brittle failure.

Numerical study on the rotation capacity of CFRP strengthened cold formed steel beams

  • Serror, Mohammed H.;Soliman, Essam G.;Hassan, Ahmed F.
    • Steel and Composite Structures
    • /
    • v.23 no.4
    • /
    • pp.385-397
    • /
    • 2017
  • Currently, CFRP (Carbon Fiber Reinforced Polymer) plate bonding is used quite extensively as a strengthening method. In this technique, a composite CFRP plate or sheet of relatively small thickness is bonded with an adhesion material to steel or concrete structure in order to improve its structural behavior and strength. The sheets or plates do not require much space and give a composite action between the adherents. In this study, the rotation capacity of CFRP-strengthened cold-formed steel (CFS) beams has been evaluated through numerical investigation. Studies on different structural levels have been performed. At the beam level, C-section has been adopted with different values of profile thickness, web height, and flange width. At the connection level, a web bolted moment resistant type of connection using through plate has been adopted. In web-bolted connections without CFRP strengthening, premature web buckling results in early loss of strength. Hence, CFRP sheets and plates with different mechanical properties and geometric configurations have been examined to delay web and flange buckling and to produce relatively high moment strength and rotation capacity. The numerical results reveal that CFRP strengthening may increase strength, initial stiffness, and rotation capacity when compared with the case without strengthening.

Damage Evaluation of Cracked Laminated Composite Plates Using Experimental Modal Analysis (실험 모드해석을 이용한 균열 적층복합판의 손상평가)

  • Kim, Joo-Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.4
    • /
    • pp.399-410
    • /
    • 2012
  • In this study, vibration tests are performed on cantilevered and clamped-clamped laminated composite rectangular plates using experimental modal analysis technique. The damages are simulated by applying progressive line cracks to the laminated composite plates for damage evaluations due to crack growth. The changes of frequency response functions(FRFs), MAC values, and modal parameters (frequency, mode shape and damping ratio) of the damaged composite plates, which are obtained by the modal testing of impact hammer, are investigated. Each experimental modal parameter of the progressively damaged composite plates is compared with natural frequencies and mode shapes obtained by finite element analysis. It is seen that the damage can be evaluated from the changes in the geometric properties and structural behaviors of the laminated composite plates resulting from the model updating process of the finite element model as a benchmark.

Compression Behavior of Steel Plate-Concrete Structures for both Stiffened and Nonstiffened structures by Rib (리브 보강 유무에 따른 강판-콘크리트 구조의 압축거동)

  • Choi, Byong Jeong;Han, Hong Soo;Han, Kweon Gyu;Lee, Seung Joon
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.5
    • /
    • pp.471-481
    • /
    • 2009
  • The purpose of this study was to compare and analyze the compression behaviors of SSC (stiffened steel plate-concrete) and NSC (non-stiffened steel plate-concrete) structures, and to identify the effects of the increment in the structural performance of SSC structures. SCC structures are structures that integrate steel plates with line support from ribs (H-shape) and point supports from studs with concretes. On the other hand, NSC structures are structures that integrate steel plates with point supports from studs with concrete. The following results were obtained in this study. First, compared with NSC structures, it was shown that SSC structures have advantages in terms of preventing steel plate buckling and delaying quick destruction through the brittleness of concrete. In addition, the SSC structures showed a 5-28% increment in maximum compressive strength, which far surpassed that shown by the NSC structures.

Effect of welding variables on the crack arrest toughness of thick steel plate (선급 극후물재의 취성균열 전파 정지 인성에 미치는 용접변수의 영향)

  • Ryu, Kang-Mook;An, Gyu-Baek;Kim, Tae-Su;Lee, Tae-Yeung;Lee, Jong-Sub
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.103-103
    • /
    • 2009
  • As the size of containership increased over 14,000TEU, thick steel plate with high strength has been used. The plate thickness increased over 70mm and yield strength of the steel plate was around $47kg_f/mm^2$. Many researchers reported that the thick welded plate has low crack arrest toughness. They noticed the crack arrest ability is dependent on the plate thickness. In other words, brittle crack propagates straightly along the welded line and make abrupt fracture in the thick plate which causes low $K_{ca}$. In this study, the other factors, especially welding heat input, to cause low crack arrest toughness was investigated for thick steel plate welds. EH grade steel plates were used in this study and 50 to 80 thick plates were tested to confirm thickness sensitivity. Electro gas welding (EGW) and flux cored arc welding (FCAW) were adopted to prepare the welded joints. Temperature gradient ESSO test was performed to measure $K_{ca}$ values with the variation of welding variables. As a result of this study, regardless of plate thickness, welding heat input to cause welding residual stress around crack path is a key factor to control the brittle crack propagation in welded joints.

  • PDF

Impact response of a novel flat steel-concrete-corrugated steel panel

  • Lu, Jingyi;Wang, Yonghui;Zhai, Ximei;Zhou, Hongyuan
    • Steel and Composite Structures
    • /
    • v.42 no.2
    • /
    • pp.277-288
    • /
    • 2022
  • A novel flat steel plate-concrete-corrugated steel plate (FS-C-CS) sandwich panel was proposed for resisting impact load. The failure mode, impact force and displacement response of the FS-C-CS panel under impact loading were studied via drop-weight impact tests. The combined global flexure and local indentation deformation mode of the FS-C-CS panel was observed, and three stages of impact process were identified. Moreover, the effects of corrugated plate height and steel plate thickness on the impact responses of the FS-C-CS panels were quantitatively analysed, and the impact resistant performance of the FS-C-CS panel was found to be generally improved on increasing corrugated plate height and thickness in terms of smaller deformation as well as larger impact force and post-peak mean force. The Finite Element (FE) model of the FS-C-CS panel under impact loading was established to predict its dynamic response and further reveal its failure mode and impact energy dissipation mechanism. The numerical results indicated that the concrete core and corrugated steel plate dissipated the majority of impact energy. In addition, employing end plates and high strength bolts as shear connectors could prevent the slip between steel plates and concrete core and assure the full composite action of the FS-C-CS panel.

Application of a new extended layerwise approach to thermal buckling load optimization of laminated composite plates

  • Topal, Umut
    • Steel and Composite Structures
    • /
    • v.14 no.3
    • /
    • pp.283-293
    • /
    • 2013
  • This paper deals with the applicability of a new extended layerwise optimization method for thermal buckling load optimization of laminated composite plates. The design objective is the maximization of the critical thermal buckling of the laminated plates. The fibre orientations in the layers are considered as design variables. The first order shear deformation theory (FSDT) is used for the finite element solution of the laminates. Finally, the numerical analysis is carried out to show the applicability of extended layerwise optimization algorithm of laminated plates for different parameters such as plate aspect ratios and boundary conditions.

Behavior of reinforced concrete plates under impact loading: different support conditions and sizes

  • Husem, Metin;Cosgun, Suleyman I.
    • Computers and Concrete
    • /
    • v.18 no.3
    • /
    • pp.389-404
    • /
    • 2016
  • In this study, effects of impact loads on reinforced concrete (RC) plates are examined analytically. During examination of RC plates, they were exposed to impact loading with two different support conditions in three different sizes. RC plates in different support conditions were analyzed with Concrete Damage Plasticity Model (CDP) and reinforcing steel was modeled with Classical Metal Plasticity Model (CMP) by ABAQUS finite element software. After the analysis it is found that impact loads, displacements, energy absorption capacities and damage patterns are changed due to support conditions and plate sizes. Results that are obtained from RC plate experiments in literature under impact loads are found to be similar with the results of numerical analysis with CDP material models.

Dynamic analysis of functionally graded nanocomposite plates reinforced by wavy carbon nanotube

  • Moradi-Dastjerdi, Rasool;Momeni-Khabisi, Hamed
    • Steel and Composite Structures
    • /
    • v.22 no.2
    • /
    • pp.277-299
    • /
    • 2016
  • In this paper, free vibration, forced vibration, resonance and stress wave propagation behavior in nanocomposite plates reinforced by wavy carbon nanotube (CNT) are studied by a mesh-free method based on first order shear deformation theory (FSDT). The plates are resting on Winkler-Pasternak elastic foundation and subjected to periodic or impact loading. The distributions of CNTs are considered functionally graded (FG) or uniform along the thickness and their mechanical properties are estimated by an extended rule of mixture. In the mesh-free analysis, moving least squares (MLS) shape functions are used for approximation of displacement field in the weak form of motion equation and the transformation method is used for imposition of essential boundary conditions. Effects of CNT distribution, volume fraction, aspect ratio and waviness, and also effects of elastic foundation coefficients, plate thickness and time depended loading are examined on the vibrational and stresses wave propagation responses of the nanocomposite plates reinforced by wavy CNT.