• Title/Summary/Keyword: steel pier

Search Result 154, Processing Time 0.022 seconds

Design of Pull Box Members on the Landing Pier Using Finite Element Analysis of a Steel Plate (강재 플레이트 유한요소해석을 이용한 잔교 상부의 풀 박스 부재의 선정)

  • Kim, Sungwon;Hong, Hyemin;Han, Taek Hee;Seo, Seung Nam
    • Journal of Coastal Disaster Prevention
    • /
    • v.4 no.3
    • /
    • pp.111-118
    • /
    • 2017
  • In this study, pull box members were designed by finite element analysis of a steel plate covering a pull box to secure its safety on the landing pier dedicated to the large research survey ship. It was assumed that the maximum load is due to the 250 tonf class crane used for unloading work when the working environment in the upper part of the landing pier was considered. The safety of the pull box was evaluated by the comparison between the yield strength of the steel plate and the result of stress analysis on the steel plate due to the crane load. It was found that the stress at the plate from the crane load exceeded the yield strength of the steel(205MPa) when the upper part of the pull box was protected by a $1950{\times}1950mm$ steel plate cover. In order to compensate for this, a concrete filled steel tube(CFT) column with a diameter of 150 mm and a steel thickness of 10 mm was reinforced at the center of the plate, and the finite element analysis was carried out. However, the maximum stress at the steel plate was higher than the yield strength of the steel in some load cases so that it was tried to find appropriate thickness of the steel plate and diameter of the CFT columns. Finally, the analysis results showed that the safety of the pull box was secured when the thickness of the steel plate and the diameter of the CFT column were increased to 30mm and 180mm, respectively.

Seismic-performance Experiments of Circular Shear Piers Considering Effects of Rebar Corrosion, Lap splice and Axial Load (철근부식, 겹침이음 및 축하중의 영향을 고려한 원형 전단 교각의 내진성능실험)

  • Lee, Soo-Hyung;Lee, Seung-Geon;Lee, Hyerin;Hong, Kee-Jeung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.143-153
    • /
    • 2021
  • The corroded pier that has corrosion of the tranverse steel, main steel and lapsplice directly affects the seismic performance. The corrosion of the tranvese and main steel directly reduce the shear strength and bendig strength. If steel corrosion occurs in lap splice, the flexural strength and flexibility of existing corroded pier that are not seismic design are significantly reduced. In addition, as the axial force acting on the pier increase the shear strength. Considering these effects. In this stuydy, we cosidered steel corrosion, lap splice and axial force, for a reasonable evaluation of seismic-performance. It is confirmed that flexular failure occurs at pies where shear failure is expected to occur due to corrosion of reinforcement. These failure modes and their reason are analyzed, and necessary considerations are presented for seismic reinforcement.

Optimal Design of Prefabricated Passenger Car-overpass Structures (승용차 전용 조립식 고가도로의 최적설계)

  • 조성배;김영우;신영석
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.10a
    • /
    • pp.163-170
    • /
    • 2004
  • The main objective of this research is to determine the optimal sections of infrastructure (the pier and foundation) for orthotropic steel decks which is a part of prefabricated passenger car overpasses. Since the bridge to be designed allows only passenger cars, design loads are determined according to this condition. The total volume of the infrastructure is formulated as the objective function and the design constraints are based on the 'Korean Bridge Design Code' and 'Design Manual of Steel Framed Pier'. The programs used in this research are MATLAB 6.5 and MIDAS CIVIL.

  • PDF

Field Test on Rigidities of Piers in High-speed Railway (고속전철 교각의 강성도 산정을 위한 현장실험)

  • 진원종;곽종원;김병석;박성용
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.745-750
    • /
    • 2000
  • The rigidity of pier is important in the analysis of rail on high speed railway bridges. This study is being performed because of followings. 1) Actual longitudinal stiffness of the structure including substructure should be considered in the calculation of longitudinal stresses in rails. 2) There are many uncertainties in piers and foundations for design. 3) Actual guideline for the design of piers is necessary. 4) Measurement on the rigidity of pier according to the types of pier, foundation and soil-condition is needed. Curve for rigidity will be obtained through this study and applied for actual design as the guideline. Stresses in rails can be estimates accurately. A pair of piers, which consists of pot-bearing for fixed support and pad-bearing for movable support, is loaded by steel frame through steel wire ropes. The responses which are intended to measure in the field test are displacements, forces and tilts on the top of piers.

  • PDF

A Study on the Seismic Evaluation of Steel Piers by Earthquake Response Characterisitcs (지진응답특성에 의한 강재교각의 내진성 평가에 관한 연구)

  • 권영록;손영호;최광규
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.4 no.3
    • /
    • pp.45-53
    • /
    • 2000
  • 강재 교각을 갖는 고가교량은 상부구조가 매우 큰 질량을 갖는 거대구조가 되고 규모가 큰 지진운동 하에서 대단히 큰 관성력을 받게 된다. 따라서 탄소성 동적응답 해석에 의해서 강재 교각의 지진거동을 파악하는 것이 필요하다 . 본 연구에서는, 탄소성 동적응답해석을 위한 합리적인 수치해석방법을 제시하고 이를 바탕으로 강재 교각에 대한 내진성 평가를 수행한다. 1995년 고베 지진 시 손상을 받은 강재 교각과 그 이후 재구축된 교각을 모델로 해서 국부좌굴 이전 소성화의 영향만을 고려한 강재 교각의 지진 거동을 파악한다. 입력지진파는 고베 지진시 관측된 Takatori 지진파이고 이를 가속도 진폭 조정하여 사용한다.

  • PDF

Strength degradation of reinforced concrete piers wrapped with steel plates under local corrosion

  • Gao, Shengbin;Ni, Jie;Zhang, Daxu;Ge, Hanbin
    • Steel and Composite Structures
    • /
    • v.24 no.6
    • /
    • pp.753-765
    • /
    • 2017
  • This paper aims to investigate the strength degradation of reinforced concrete piers wrapped with steel plates which corrode at the pier base by employing a three dimensional elasto-plastic finite element formulation. The prediction accuracy of the employed finite element analysis method is firstly verified by comparing the analytical results with test results. Then, a series of parametric studies is carried out to investigate the effects of steel plate's corrosion position along width direction, corrosion depth along plate thickness, corrosion range along width direction, and steel plate-concrete bonding degradation on the strength of the piers. It is observed that the strength degradation of the piers is closely related to steel plate's corrosion position, corrosion depth and corrosion range in the case of local corrosion on the webs. In contrast, when the base of flanges corrodes, the strength degradation of the piers is only related to steel plate's corrosion depth and corrosion range, and the influence of corrosion position on the strength degradation is very gentle. Furthermore, the strength of the piers decreases with the degradation of steel plate-concrete bonding behavior. Finally, the maximum strength of the piers obtained from numerical analysis corresponding to different bonding behavior is compared with theoretical results within an accepted error.

Load-carrying capacity degradation of reinforced concrete piers due to corrosion of wrapped steel plates

  • Gao, Shengbin;Ikai, Toyoki;Ni, Jie;Ge, Hanbin
    • Steel and Composite Structures
    • /
    • v.20 no.1
    • /
    • pp.91-106
    • /
    • 2016
  • Two-dimensional elastoplastic finite element formulation is employed to investigate the load- carrying capacity degradation of reinforced concrete piers wrapped with steel plates due to occurrence of corrosion at the pier base. By comparing with experimental results, the employed finite element analysis method is verified to be accurate. After that, a series of parametric studies are conducted to investigate the effect of corrosion ratio and corrosion mode of steel plates located near the base of in-service pier P2 on load-carrying capacity of the piers. It is observed that the load-carrying capacity of the piers decreases with the increase in corrosion ratio of steel plates. There exists an obvious linear relationship between the load-carrying capacity and the corrosion ratio in the case of even corrosion mode. The degradation of load-carrying capacity resulted from the web's uneven corrosion mode is more serious than that under even corrosion mode, and the former case is more liable to occur than the latter case in actual engineering application. Finally, the failure modes of the piers under different corrosion state are discussed. It is found that the principal tensile strain of concrete and yield range of steel plates are distributed within a wide range in the case of slight corrosion, and they are concentrated on the column base when complete corrosion occurs. The findings obtained from the present study can provide a useful reference for the maintenance and strengthening of the in-service piers.

Experimental Evaluation for Seismic Performance of RC Bridge Piers with FRP Confinement (FRP 횡보강근을 이용한 RC 교각의 내진성능 평가 실험)

  • 정영수;박진영;박창규;서진원
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.377-384
    • /
    • 2003
  • Recently, there are much concerns about new and innovative transverse materials which could be used instead of conventional transverse steel in reinforced concrete bridge piers. FRP materials could be substituted for conventional transverse steel because of their sufficient strength, light weight, easy fabrication, and useful applicability to any shapes of pier sections, such as rectangular or circular sections. The objective of this research is to evaluate the seismic performance of reinforced concrete bridge pier specimens with FRP transverse reinforcement by means of the Quasi-Static test. In the first task, test columns were made using FRP rope, but these specimens appeared to fail at low displacement ductility levels due to insufficient confinement of strand extension itself. Therefore, the second task was to evaluate the seismic performance of test specimens transversely confined with FRP band. Although FRP banded specimens showed lower seismic performance than the specimen with spiral reinforcing steel, it satisfied with the response modification factor, 3, required for the single column of Korea bridge roadway design code. It was concluded that FRP band could be efficiently substituted for conventional reinforcing steel.

  • PDF

A Study of Pier-Segment Joint for Fabricated Internally Confined Hollow CFT Pier (조립식 내부 구속 중공 CFT 교각을 위한 교각세그먼트 접합부 연구)

  • Won, Deok-Hee;Han, Taek-Hee;Lee, Dong-Jun;Kang, Young-Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.2
    • /
    • pp.161-171
    • /
    • 2010
  • Bridges have undergone distinctive development in accordance of the introduction of new materials and structural types. The importance on rapid construction technology is currently attracting more and more attention worldwidely as well as domestically because its effectiveness in reducing the overall construction cost. While a wide ranges of previous researches on rapid construction of super structures are available, the studies on substructures are quite limited. The development of the precast segmental internally confined hollow CFT piers are briefly introduced herein and design formulas are presented for pier segment joints, Also, a extensive parametric studies are carried out for the effect of the constitutive elements of the joints. Finally, the design formulas are verified throughout a series of extensive finite element analyses.

Seismic Risk Analysis of Steel Pile Type Pier (잔교식 안벽구조물의 확률론적 지진위험도해석)

  • Kim, Dong-Hyawn;Cho, Hong-Yeon;Kim, Doo-Kie;Cho, Byung-Il
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.3
    • /
    • pp.237-243
    • /
    • 2007
  • Probabilistic seismic risk analysis was performed. Exceeding probabilities of combined stress and maximum horizontal displacement of steel piled pier due to surface ground motion which was transferred from base rock motion was expressed as seismic fragility curves. Occurrence probability of peak ground motion was calculated by using the seismic hazard map on design code for harbor and fishery structures of Korea. Finally seismic risk of pier structure was found by combining the fragility and the hazard and those were presented through numerical analysis.