• Title/Summary/Keyword: steel fiber-reinforced concrete

Search Result 1,083, Processing Time 0.027 seconds

Tensile Strain of Steel Fiber Reinforced Concrete under Fatigue Load (피로하중을 받는 강섬유보강콘크리트의 인장변형에 관한 연구)

  • 장동일;채원규;박철우;민인기
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1992.10a
    • /
    • pp.82-87
    • /
    • 1992
  • In this thesis, the fatigue tests were performed on a series of SFRC (steel fiber reinforced concrete)to investigate the flexural tensile behavior of SFRC varying with the steel fiber contents and the steel fiber aspect ratios. Beam specimens of 10$\times$10$\times$60cm are used. the specimen series are classified according to the steel fiber contents varying 0.5. 1.0, 1.5%, and to the steel fiber aspect ratios varying 60, 80, 100. The three point loading system was used in the fatigue tests. The minimum value of repeated loading was fixed at 10.0kgf and maximum value was 75% to static ultimate strength for periodically using concrete strain gages located at the lower end of the mid-span, and the stress-strain curves were drawn for each specimens, respectively. From the tests result, it was found that the larger steel fiber content and the smaller the steel fiber aspect ratio is , the tensile strain of SFRC under fatigue load proportionally increases. By the regression analysis on these results, the empirical formulae to predict the tensile strain of SFRC were suggested. In comparison of the tensile elastic modulus under fatigue load, it was also found that the larger steel fiber content and the smaller steel fiber aspect ratio is , the smaller decreasing rate of the stiffness of SFRC under fatigue load decreased.

  • PDF

Effectiveness of steel fibers in ultra-high-performance fiber-reinforced concrete construction

  • Dadmand, Behrooz;Pourbaba, Masoud;Sadaghian, Hamed;Mirmiran, Amir
    • Advances in concrete construction
    • /
    • v.10 no.3
    • /
    • pp.195-209
    • /
    • 2020
  • This study investigates the behavior of ultra-high-performance fiber-reinforced concrete (UHPFRC) with hybrid macro-micro steel and macro steel-polypropylene (PP) fibers. Compression, direct and indirect tension tests were carried out on cubic and cylindrical, dogbone and prismatic specimens, respectively. Three types of macro steel fibers, i.e., round crimped (RC), crimped (C), and hooked (H) were combined with micro steel (MS) and PP fibers in overall ratios of 2% by volume. Additionally, numerical analyses were performed to validate the test results. Parameters studied included, fracture energy, tensile strength, compressive strength, flexural strength, and residual strength. Tests showed that replacing PP fibers with MS significantly improves all parameters particularly flexural strength (17.38 MPa compared to 37.71 MPa). Additionally, the adopted numerical approach successfully captured the flexural load-deflection response of experimental beams. Lastly, the proposed regression model for the flexural load-deflection curve compared very well with experimental results, as evidenced by its coefficient of correlation (R2) of over 0.90.

An Experimental Study on the Load Carrying Capacity and Deformation Properties of Steel Fiber Reinforced Concrete Slab (강섬유보강 콘크리트 슬래브의 내력 및 변형특성에 관한 실험적 연구)

  • 박승범;조광연;신동기;장석호;김부일
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.327-332
    • /
    • 1997
  • This study is aimed to investigate the effect of load and deflection on steel fiber reinforced concrete slab. Slabs were made with Hooked and Straight types steel fiber and compared a change of steel fiber contents and fiber types. Test were carried out to evaluate he first crack load, maximum load and deflection of slab. At the result, the first crack load, maximum load and energy absorption capacity were increased remarkably as steel fiber contents wee increased. And we found that the deflection of slab at same load ere decreased as steel fiber contents were increased, too. As the aspect ration was increased, the first crack load, maximum load and energy absorption capacity were increased.

  • PDF

A experimental study on the long-term response of high-strength Steel-Fiber Reinforced Concrete (고강도 강섬유 보강 콘크리트의 장기거동 특성에 관한 실험적 연구)

  • Seo Jong-Myeong;Kim Jae-Ki;Lee Joo-Ha;Yoon Young-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.337-340
    • /
    • 2004
  • In recent days, the beneficial effects of using fiber reinforced concrete, especially Steel Fiber Reinforced Concrete, have been on the rise. However, few studies on long-term behavior of SFRC are executed in spite of great demand of SFRC. The fact that SFRC is far better than NRC in various properties such as tensile strength, ductility, flexural toughness has been certified by many researchers. And, those advantages can be also applied to decrease the structures deterioration induced by creep and shrinkage. Furthermore, even though it is fact that SFRC is generally used in joint members to distribute concentrated stresses by fibers, SFRC is treated as NRC in designing especially for long-term behavior of structures. So this paper is about a study on the long-term response of SFRC applied to HPC about 40MPa. Therefore, in this paper, the test results of eighteen high-strength concrete specimens and steel fiber-reinforced concrete specimens, with steel fiber content of $1\%$ by volume were presented. The test result shows that SFRC is advantageous rather than NRC in long-term response.

  • PDF

An efficient and novel strategy for control of cracking, creep and shrinkage effects in steel-concrete composite beams

  • Varshney, L.K.;Patel, K.A.;Chaudhary, Sandeep;Nagpal, A.K.
    • Structural Engineering and Mechanics
    • /
    • v.70 no.6
    • /
    • pp.751-763
    • /
    • 2019
  • Steel-concrete composition is widely used in the construction due to efficient utilization of materials. The service load behavior of composite structures is significantly affected by cracking, creep and shrinkage effects in concrete. In order to control these effects in concrete slab, an efficient and novel strategy has been proposed by use of fiber reinforced concrete near interior supports of a continuous beam. Numerical study is carried out for the control of cracking, creep and shrinkage effects in composite beams subjected to service load. A five span continuous composite beam has been analyzed for different lengths of fiber reinforced concrete near the interior supports. For this purpose, the hybrid analytical-numerical procedure, developed by the authors, for service load analysis of composite structures has been further improved and generalized to make it applicable for composite beams having spans with different material properties along the length. It is shown that by providing fiber reinforced concrete even in small length near the supports; there can be a significant reduction in cracking as well as in deflections. It is also observed that the benefits achieved by providing fiber reinforced concrete over entire span are not significantly more as compared to the use of fiber reinforced concrete in certain length of beam near the interior supports in continuous composite beams.

An Experimental Study on Properties of Steel Fiber Reinforced Fresh Concrete Using Waste concrete (폐콘크리트를 이용한 굳지 않은 강섬유 보강 콘크리트의 특성에 관한 실험적 연구)

  • 구봉근;김창운;박재성
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.245-248
    • /
    • 1999
  • In our standard specification, the specific provision of steel fiber pavement concrete didn't describe yet. The purpose of this study presents criteria of recycled aggregate steel fiber pavement concrete including standard crushed stone steel fiber pavement concrete. This study examined a lot of factors which influence consistency of SFRC(Steel Fibre Reinforced Concrete) including crush stone and recycled aggregate. According to this examination, this study decided optimum S/α and W which are essential to pavement concrete mix proportion. Come to the conclusion, this study is expected to effect economically in recycling of resources and bring to affirmative result in aspect of environment.

  • PDF

Steel Fibers Efficiency as Shear Reinforcement in Concrete Beams (섬유보강콘크리트 보의 전단거동에 미치는 강섬유의 효과)

  • 문제길;홍익표
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.2
    • /
    • pp.118-128
    • /
    • 1994
  • There have been conducted a lot of works on shear behavior of steel fiber reinforced concrete beams. Fiber reinforced concrete beams without shear reinforcement were tested to determine their cracking shear strengths and ultimate shear capacities. Results of tests on 14 reinforced concrete beams (including 11 containing steel fibers) are reported. Two parameters were varied in the study, namely, the volume fraction of fibers and shear span-to-depth ratio.The effects of fiber incorporation on failure modes, deflections, cracking shear strength, and ul~imate shear strength have been examined. Resistance to shear stresses have been found to be improved by the inclusion of fibers, The mode of failure changed from shear to flexure when the shear span-to-depth ratio exceeds 3.4. Based on these investigations, a method of computing the shear strength of steel fiber reinforced concrete beam is suggested. The comparisons between computed values and expenmentally observed values are shown to verify the proposed theoretical treatment and steel fibers efficiency.

A Study on the flexural Behavior of Ultra-Strength Steel Fiber Reinforced Concrete (초고강도 강섬유 보강 콘크리트의 휨특성에 관한 연구)

  • Ryu, Gum-Sung;Park, Jung-Jun;Kang, Su-Tea;Koh, Kyung-Taeg;Kim, Sung-Wook
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.333-336
    • /
    • 2005
  • This paper presents a comparative evaluation of eight different types of steel fibers used as reinforcing material in concrete beams. The fibers which used ultra-strength steel fiber reinforced concrete were fiber length of 30 to 60mm, aspect ratio of 43 to 86, W/B ratio 0.16 to 0.30, fiber types of both ends hooked and straight shape and fiber volume fraction of 1 to 5$\%$. As for the test results, it estimated the influence of fiber volume, length and aspect ratio on the mechanical properties of high toughness concrete, the mechanical properties improved according to increase fiber volume, to increase aspect ratio and to long fiber length. And the resonable fiber volume in high toughness concrete was analyzed 2$\%$ based on the results of mechanical properties.

  • PDF

Development Strength of Headed Reinforcing Bars for Steel Fiber Reinforced Concrete by Pullout Test

  • Kim, Seunghun;Paek, Sungchol;Lee, Changyong;Yuk, Hyunwoong;Lee, Yongtaeg
    • Architectural research
    • /
    • v.20 no.4
    • /
    • pp.129-135
    • /
    • 2018
  • In order to compare the development performance of headed reinforcing bar and straight reinforcing bar in tension for steel fiber reinforced concrete (SFRC), pullout test of specimens with reinforcing bar which was anchored on simple beam perpendicularly was conducted. The experimental variables were steel fiber volume ratio ($V_{Rsf}$), concrete compressive strength, and existence of head. As the result of test, splitting failure of concrete in the development direction of reinforcing bar in most specimens was observed. For development detail of headed reinforcing deformation bar, specimens with 1% $V_{Rsf}$ showed approximately 63%~119% increase in pullout strength compare to specimens with 0% $V_{Rsf}$. Test result shows that SFRC is more effective in increasing pullout strength for headed reinforcing bars than increasing pullout strength of straight bars.

Flexural-Shear Behavior of Steel Fiber Reinforced High Strength Concrete Beams (훅트강섬유보강 고강 콘크리트 보의 휨전단 거동)

  • 한형섭;박인철;김명성;김윤일
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.567-572
    • /
    • 1999
  • Experimental study was conducted to investigate the flexural-shear behavior of hooked steel fiber reinforced high strength concrete (SFRHC) beams. Twenty beams with shear span-depth ratio of 1.45 were tested, of which variables were the contents of steel fiber with aspect ratio of 60, tension reinforcement ratio and concrete compressive of 60MPa and 80MPa. Test results has shown that shear failure of the beams were changed into flexural-shear failure or flexural failure according to increasing steel fiber content, that SFRHC with slump of 15cm over and fiber volume ratio of 1.5% was possible in practice, and that proper volume ratio of steel fiber was 1.5%.

  • PDF