• 제목/요약/키워드: steel beam-columns

검색결과 307건 처리시간 0.019초

Behaviour of cold-formed steel concrete infilled RHS connections and frames

  • Angeline Prabhavathy, R.;Samuel Knight, G.M.
    • Steel and Composite Structures
    • /
    • 제6권1호
    • /
    • pp.71-85
    • /
    • 2006
  • This paper presents the results of a series of tests carried out on cold-formed steel rectangular hollow and concrete infilled beam to column connections and frames. A stub column was chosen such that overall buckling does not influence the connection behaviour. The beam chosen was a short-span cantilever with a concentrated load applied at the free end. The beam was connected to the columns along the strong and weak axes of columns and these connections were tested to failure. Twelve experiments were conducted on cold-formed steel direct welded tubular beam to column connections and twelve experiments on connections with concrete infilled column subjected to monotonic loading. In all the experiments conducted, the stiffness of the connection, the ductility characteristics and the moment rotation behaviour were studied. The dominant mode of failure in hollow section connections was chord face yielding and not weld failure. Provision of concrete infill increases the stiffness and the ultimate moment carrying capacity substantially, irrespective of the axis of loading of the column. Weld failure and bearing failure due to transverse compression occurred in connections with concrete infilled columns. Six single-bay two storied frames both with and without concrete infill, and columns loaded along the major and minor axes were tested to failure. Concentrated load was applied at the midspan of first floor beam. The change in behaviour of the frame due to provision of infill in the column and in the entire frame was compared with hollow frames. Failure of the weld at the junction of the beam occurred for frames with infilled columns. Design expressions are suggested for the yielding of the column face in hollow sections and bearing failure in infilled columns which closely predicted the experimental failure loads.

콘크리트 충전 각형강관 기둥부재의 한계축력 및 누적한계축력에 관한 연구 (Study on the Strength of Limit Axial Force and Accumulated Limit Axial Force of Concrete Filled Square Tube Columns)

  • 서성연;정진안;김성용
    • 한국강구조학회 논문집
    • /
    • 제17권5호통권78호
    • /
    • pp.605-615
    • /
    • 2005
  • 수평하중을 받는 콘크리트충전 각형강관 기둥의 축력과 변형능력의 관계를 조사하기 위하여 실험 및 해석적 연구를 수행하였다. 36개 기둥으로 구성된 실험 시리즈는 일정 축하중과 수평하중 하에서 반복실험을 실시하였다. 반복 수평하중을 받는 기둥이 저항할 수 있는 축하중을 보증내력 한계축력이라고 규정하였으며, 해석 모델은 수평하중을 받는 캔틸레버 기둥을 모델화하였다. 반복 횡하중을 받는 기둥의 축하중을 누적보증내력 한계축력이라고 정의하였다. 본 연구의 목적은 주어진 동일부재각에 부합하는 축력과 수평하중을 받는 콘크리트 충전강관 기둥의 보증내력 한계축력을 연구하기 위한 것이며, 두 번째는 콘크리트 충전강관 기둥의 누적보증내력 한계축력과 보증내력 한계축력의 비교가 본 연구의 목적이다.

An experimental study of connections between I-beams and concrete filled steel tubular columns

  • De Nardin, Silvana;El Debs, Ana Lucia H.C.
    • Steel and Composite Structures
    • /
    • 제4권4호
    • /
    • pp.303-315
    • /
    • 2004
  • Frame composed of concrete-filled steel tubular columns and I-shaped steel beam has been researched in order to development reasonable connection details. The present paper describes the results of an experimental program in four different connection details. The connection details considered include through-bolt between I-shaped steel beams and concrete-filled steel tubular columns and two details of welded connections. One of the welded connection details is stiffened by angles welded in the interior of the profile wall at the beam flange level. The specimens were tested in a cruciform loading arrangement with variable monotonic loading on the beams and constant compressive load on the column. For through-bolt details, the contribution of friction and bearing were investigated by embedding some of the bolts in the concrete. The results of the tests show that through-bolt connection details are very ductility and the bearing is not important to the behavior of these moment connections. The angles welded in the interior of the profile wall increase the strength and stiffness of the welded connection detail. In addition, the behavior curves of these connections are compared and some interesting conclusions are drawn. The results are summarized for the strength and stiffness of each connection.

Behavior of stiffened and unstiffened CFT under concentric loading, An experimental study

  • Deifalla, Ahmed F.;Fattouh, Fattouh M.;Fawzy, Mona M.;Hussein, Ibrahim S.
    • Steel and Composite Structures
    • /
    • 제33권6호
    • /
    • pp.793-803
    • /
    • 2019
  • Concrete-filled steel tubular (CFST) beam-columns are widely used owing to their good performance. They have high strength, ductility, large energy absorption capacity and low costs. Externally stiffened CFST beam-columns are not used widely due to insufficient design equations that consider all parameters affecting their behavior. Therefore, effect of various parameters (global, local slenderness ratio and adding hoop stiffeners) on the behavior of CFST columns is studied. An experimental study that includes twenty seven specimens is conducted to determine the effect of those parameters. Load capacities, vertical deflections, vertical strains and horizontal strains are all recorded for every specimen. Ratio between outer diameter (D) of pipes and thickness (t) is chosen to avoid local buckling according to different limits set by codes for the maximum D/t ratio. The study includes two loading methods on composite sections: steel only and steel with concrete. The case of loading on steel only, occurs in the connection zone, while the other load case occurs in steel beam connecting externally with the steel column wall. Two failure mechanisms of CFST columns are observed: yielding and global buckling. At early loading stages, steel wall in composite specimens dilated more than concrete so no full bond was achieved which weakened strength and stiffness of specimens. Adding stiffeners to the specimens increases the ultimate load by up to 25% due to redistribution of stresses between stiffener and steel column wall. Finally, design equations previously prepared are verified and found to be only applicable for medium and long columns.

기둥과 보-기둥 구조물의 비탄성 좌굴거동 (Inelastic Buckling Behavior of Column and Beam-Column)

  • 이동식;오순택
    • 한국강구조학회 논문집
    • /
    • 제16권2호통권69호
    • /
    • pp.215-224
    • /
    • 2004
  • 에너지법을 이용하여 보-기둥 및 기둥의 비탄성 좌굴거동을 해석하였다. 미국에서 생산되는 I 형강에 적용되는 단순형 잔류응력 모델을 우리나라에서 생산되는 I 형강에 적용하였다. 먼저, 집중 압축 축하중과 균등 휨을 동시에 받는 I 형강에 대하여 비탄성 횡-비틀림 좌굴거동을 알아보고 보-기둥에서의 잔류응력의 영향을 해석하였다. 또한 기둥의 경우에 대하여 해석하였으며 얻어진 결과를 강구조편람에 의한 설계 시의 값과 비교하였다. 결론적으로 강구조편람에 의한 설계는 과설계가 됨을 알 수 있었다.

The EC3 approach to the design of columns, beams and beam-columns

  • Nethercot, D.A.;Gardner, L.
    • Steel and Composite Structures
    • /
    • 제5권2_3호
    • /
    • pp.127-140
    • /
    • 2005
  • Procedures given in Eurocode 3 Part 1.1 (EN 1993-1-1) for design of the main types of structural member under given systems of loading are presented and described. Whereas some of these e.g. the procedure for axially loaded columns, are little changed from the early concept that appeared more than 25 years ago in the European Recommendations and have subsequently been adopted in many other steel codes of the world, others such as the interaction formulae for beam-columns are new, with aspects of the provisions still under development. For each type of member the basis of the procedure is described and some comparative comments made.

Experimental and analytical investigation of composite columns made of high strength steel and high strength concrete

  • Lai, Binglin;Liew, J.Y. Richard;Xiong, Mingxiang
    • Steel and Composite Structures
    • /
    • 제33권1호
    • /
    • pp.67-79
    • /
    • 2019
  • Composite columns made of high strength materials have been used in high-rise construction owing to its excellent structural performance resulting in smaller cross-sectional sizes. However, due to the limited understanding of its structural response, current design codes do not allow the use of high strength materials beyond a certain strength limit. This paper reports additional test data, analytical and numerical studies leading to a new design method to predict the ultimate resistance of composite columns made of high strength steel and high strength concrete. Based on previous study on high strength concrete filled steel tubular members and ongoing work on high strength concrete encased steel columns, this paper provides new findings and presents the feasibility of using high strength steel and high strength concrete for general double symmetric composite columns. A nonlinear finite element model has been developed to capture the composite beam-column behavior. The Eurocode 4 approach of designing composite columns is examined by comparing the test data with results obtained from code's predictions and finite element analysis, from which the validities of the concrete confinement effect and plastic design method are discussed. Eurocode 4 method is found to overestimate the resistance of concrete encased composite columns when ultra-high strength steel is used. Finally, a strain compatibility method is proposed as a modification of existing Eurocode 4 method to give reasonable prediction of the ultimate strength of concrete encased beam-columns with steel strength up to 900 MPa and concrete strength up to 100 MPa.

고강도 H형강 부재의 좌굴내력과 설계식에의 적용에 관한 연구 (The Bucking Strength and the Application of design of Design Formula of High Strength H-Shaped Section Steel Members)

  • 김진경;김희동;이명재
    • 한국강구조학회 논문집
    • /
    • 제13권2호
    • /
    • pp.123-131
    • /
    • 2001
  • 본 연구의 목적은 고강도 H형강 기둥재(beam-column)의 폭두께비에 관한 기준을 조사하고 좌굴내력을 평가하여, 강구조 한계상태설계기준과 허용응력설계기준(안)과 비교함으로써, 고강도강을 사용한 기둥부재 설계시 적용된 기준식의 타당성을 검토하기 위한 것이다. 실험에 사용된 고강도강은 SM520TMC, SM570Q 등을 사용하였고, 강재의 기계적 성질과 단주의 응력-변형도 관계를 파악하기 위하여 인장시험 및 단주압축시험을 실시하였다. 또한 고강도강 기둥재의 좌굴내력을 산정하기 위하여 수치해석을 수행하였다. 수치해석에 사용된 축력-모멘트-곡률 관계는 단주압축실험에서 구해진 응력-변형도 관계를 사용하였다

  • PDF

SRC 기둥에 대한 정적실험 (Static Tests on SRC Columns)

  • 정인근;민진;심창수;정영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.97-100
    • /
    • 2004
  • Steel encased composite columns are widely used due to their excellent structural performance in terms of stiffness, strength, and ductility. However, experimental studies were usually for the columns having higher steel ratio $(3-4\%)$. There are two different design concepts for SRC columns. ACI-318 specifies the design strength of the column using the same concept of reinforced concrete columns. AISC-LRFD specifies the P-M diagram using the concept of steel column. In this paper, SRC columns have the steel ratio of $0.53\%\;and\;1.06\%$. From the test results, ACI-318 specifications showed better evaluation of SRC columns having low steel ratio. H beam and steel tube partially filled with concrete were embedded in concrete. Flexural tests showed considerably high ductility.

  • PDF

A parametric investigation on the hysteretic behaviour of CFT column to steel beam connections

  • Esfandyary, R.;Razzaghi, M.S.;Eslami, A.
    • Structural Engineering and Mechanics
    • /
    • 제55권1호
    • /
    • pp.205-228
    • /
    • 2015
  • The results of a numerical investigation pertaining to the hysteretic behaviour of concrete filled steel tubular (CFT) column to I-beam connections are discussed in detail. Following the verification of the numerical results against the available experimental tests, the nonlinear finite element (FE) analysis was implemented to evaluate the effects of different parameters including the column axial load, beam lateral support, shape and arrangement of stiffeners, stiffness of T-stiffeners, and the number of shear stiffeners. Pursuing this objective, an external CFT column to beam connection, tested previously, was selected as the case-study. The lateral forces on the structure were simulated, albeit approximately, using an incremental cyclic loading reversal applied at the beam tip. The results were compared in terms of hysteretic load-displacement curves, stress distributions in connection, strength, rotation, and energy dissipation capacity. It was shown that external T-stiffeners combined with internal shear stiffeners play an important role in the hysteretic performance of CFT columns to I-beam connections.