• Title/Summary/Keyword: steady state flow

Search Result 1,020, Processing Time 0.032 seconds

Study on Calibration Methods of Discharge Coefficient of Sonic Nozzles using Constant Volume Flow Meter

  • Jeong, Wan-Seop;Sin, Jin-Hyeon;Gang, Sang-Baek;Park, Gyeong-Am;Im, Jong-Yeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.17-17
    • /
    • 2010
  • This paper address technical issues in calibrating discharge coefficients of sonic nozzles used to measure the volume flow rate of low vacuum dry pumps. The first challenging issue comes from the technical limit that their calibration results available from the flow measurement standard laboratories do not fully cover the low vacuum measurement range although the use of sonic nozzles for precision measurement of gas flow has been well established in NMIs. The second is to make an ultra low flow sonic nozzlesufficient to measure the throughput range of 0.01 mbar-l/s. Those small-sized sonic nozzles do not only achieve the noble stability and repeatability of gas flow but also minimize effects of the fluctuation of down stream pressures for the measurement of the volume flow rate of vacuum pumps. These distinctive properties of sonic nozzles are exploited to measure the pumping speed of low vacuum dry pumps widely used in the vacuum-related academic and industrial sectors. Sonic nozzles have been standard devices for measurement of steady state gas flow, as recommended in ISO 9300. This paper introduces two small-sized sonic nozzles of diameter 0.03 mm and 0.2 mm precisely machined according to ISO 9300. The constant volume flow meter (CVFM) readily set up in the Vacuum center of KRISS was used to calibrate the discharge coefficients of the machined nozzles. The calibration results were shown to determine them within the 3% measurement uncertainty. Calibrated sonic nozzles were found to be applicable for precision measurement of steady state gas flow in the vacuum process. Both calibrated sonic nozzles are demonstrated to provide the precision measurement of the volume flow rate of the dry vacuum pump within one percent difference in reference to CVFM. Calibrated sonic nozzles are applied to a new 'in-situ and in-field' equipment designed to measure the volume flow rate of low vacuum dry pumps in the semiconductor and flat display processes.

  • PDF

Three Dimensional Unsteady Flow Characteristics inside the Catalytic Converter of 6 Cylinder Gasoline Engine (6기통 가솔린 엔진에 장착된 촉매변환기 내의 3차원 비정상 유동특성 해석)

  • 정수진;김우승
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.4
    • /
    • pp.108-120
    • /
    • 1998
  • A theoretical study of three-dimensional unsteady compressible non-reacting flow inside double flow of monolith catalytic converter system attached to 6-cylinder engine was performed for the achievement of performance improvement, reduction of light-off time, and longer service life by improving the flow distribution of pulsating exhaust gases. The differences between unsteady and steady-state flow were evaluated through the numerical computations. To obtains the boundary conditions to a numerical analysis, one dimensional non-steady gas dynamic calculation was also performed by using the method of characteristics in intake and exhaust system. Studies indicate that unsteady representation is necessary because pulsation of gas velocity may affect gas flow uniformity within the monolith. The simulation results also show that the level of flow maldistribution in the monolith heavily depends on curvature and angles of separation streamline of mixing pipe that homogenizes the exhaust gas from individual cylinders. It is also found that on dual flow converter systems, there is severe interactions of each pulsating exhaust gas flow and the length of mixing pipe and junction geometry influence greatly on the degree of flow distribution.

  • PDF

Continuation Power Flow Method for Power System including UPFC (UPFC를 포함한 전력시스템에서의 연속조류계산)

  • Lim, Jung-Uk;Moon, Seung-Ill
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1290-1292
    • /
    • 1999
  • In this paper. continuation power flow for Power system including UPFC has been performed. The decoupled model, by which power flow can be performed without any modification of conventional power flow program is used as steady-state model. A numerical example has been given to analyze the influence on the voltage stability by UPFC.

  • PDF

A Study on the Effects of Intake Port Geometry on In-Cylinder Swirl Flow Field in a Small D.I. Diesel Engine (직접분사식 소형 디젤엔진의 실린더내 스월 유동장에 미치는 흡기포트의 형상에 관한 연구)

  • Lee, Ki-Hyung;Han, Yong-Taek;Jeong, Hae-Young;Leem, Young-Chul
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.6
    • /
    • pp.38-45
    • /
    • 2004
  • This paper studies the effects of intake port configuration on the swirl that is key parameter in the flow field of direct injection diesel engines. In-cylinder flow characteristics is known to have significant effects on fuel air mixing, combustion and emissions. To investigate the swirl flow generated by various intake ports, steady state flow tests were conducted to evaluate the swirl. Helical port geometry, SCV shape and bypass were selected as the design parameters to increase the swirl flow and parametric study was performed to choose the optimal port shape that would generate a high swirl ratio efficiently. The results revealed that a key factor in generating a high swirl ratio was to suitably control the direction of the intake air flow passing through the valve seat. For these purposes, we changed the distance of helical and tangential port as well as installed bypass near the valve seat and the effects of intake port geometry on in-cylinder flow field were visualized by a laser sheet visualization method. From the experimental results, we found that the swirl ratio and mass flow rate had a trade off relation. In addition, the result indicates that the bypass is a effective method to increase the swirl ratio without sacrificing mass flow rate.

The Energy Flow and Mineral Cycles in a Zoysia japonica and a Miseanthus sinensis Ecosystem on Mt. Kwanak 5. The Cycles of Potassium (관악산의 잔디와 억새 생태계에 있어서 에너지의 흐름과 무기물의 순환 5.칼륨의 순환)

  • 장남기;김정석;심규철;강경미
    • Asian Journal of Turfgrass Science
    • /
    • v.9 no.4
    • /
    • pp.285-292
    • /
    • 1995
  • To elucidate the mineral cycles of potassium in a dynamic grassland ecosystem in a steady state condition, this investigation was cunducted along the northwest side on Mt. Kwanak. The exper-imental results may he summarized on communities of Z. japonica and M. sinensis as follows. As compared with some pronerties of the surface soils among two semi-natural grasslands, the levels of exchangeahle potassium were high in M. sinensis and low in Z. japonica. Contents of potassium for the litters of Z. japonica and M. sinensis were 1.69% and 2.51%, re-spectively. The annual production of potassium was 1.32 g /m$m^2$ in the Z. japonica grassland and 3. 08 g /m$m^2$in the M. sinensis grassland. For a case of steady production and release, the ratio of annual min- eral production to the amount accumulated on top of the mineral soil in a steady state provides estimates of the release constant k. The models of the release, accumulation and annual cycle of potassium in a grassland ecosystem are determined by the equation (1) to (3), respectively (Table 3). Since it requires a period of about each 0.693 /r, 3 /r and 5 /r years for the release and accumu-lation of 50, 95 and 99% of its steady-state level, the estimates for potassium in a dynamic grass-land ecosystem of Mt. Kwanak were 1.5, 6.6 and 11.0 years in the Z. japonica grassland, and were 2.7, 11.9 and 19.8 years in the M. sinensis grassland. The amounts of annual cycles for potassium in a grassland ecosystem under the steady-state conditions were 1.32 g /m$^2$ in the Z. japonica grassland and 3.08 g /$m^2$ in the M. sinensis grassland. Key words : ZQvsia japonica Ahscanthus sinensis, Mt. Kwanak, Potassium cycles.

  • PDF

High Temperature Plastic Deformation Behaviors of the Bulk Metallic Glass Zr-Ti-Cu-Ni-Be Alloy (벌크 비정질 Zr-Ti-Cu-Ni-Be 합금의 고온 소성 변형 특성)

  • Lee K. S.;Ha T. K.;Ahn S. H.;Chang Y. W.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2001.10a
    • /
    • pp.272-276
    • /
    • 2001
  • Multicomponent $Zr_{41.2}Ti_{13.8}Cu_{12.5}Ni_{10}Be_{22.5}$ bulk matallic glass alloy shows good bulk glass forming ability due to its high resistance to crystallization in the undercooled liquid state.1) In this study, DSC and X-ray diffractometry have been performed to confirm the amorphous structure of the master $Zr_{41.2}Ti_{13.8}Cu_{12.5}Ni_{10}Be_{22.5}$ alloy. To investigate the mechanical properties and deformation behaviors of the bulk metallic $Zr_{41.2}Ti_{13.8}Cu_{12.5}Ni_{10}Be_{22.5}$ alloy, a series of compression tests has been carried out at the temperatures ranging from $351^{\circ}C$ to $461^{\circ}C$ and at the various initial strain rates from $2{\times}10^{-4}s^{-1}\;to\;2{\times}10^{-2}s^{-1}$. There are two types of nominal stress-strain curves. The one shows linear stress-strain relationship meaning fracture at maximum stress, the other shows plastic deformation including steady-state flow. Also DSC analysis for the compressed specimens has been performed to investigate the change of thermal stability and crystallization behavior for the various test conditions.

  • PDF

Applicability Evaluation of the Characteristics Equation for a Coefficient of Permeability of Unsaturated Soils (불포화토의 투수계수 방정식의 적용성 평가)

  • Lyu, Tae-Jin;Song, Chang-Seob;Lim, Seong-Yoon
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.393-398
    • /
    • 2005
  • In order to treat flow problems for an unsaturated soils, it is required the mediation of the coefficient of permeability with variation of suction. The coefficient of permeability for soils can be determined by the direct or indirect methods. The direct methods of permeability can be performed either in the laboratory or in the field. The indirect methods can be predicted from the soil-water characteristics curve. Laboratory test methods to measure the coefficient of permeability can be categorized into two types, steady-state and unsteady-state. In this study, the coefficient of permeability for unsaturated soils was determined by the modified apparatus for steady state-method(Klute, 1972) and was predicted from the equations of Brooks and Corey(1964) and Van Genuchten(1980). Experimental results were compared with predicted coefficient of permeability and verified applicability of the two equations.

  • PDF

Effects of Strain Rate and Temperature on the Hot Strength for Single Phase Cu-Zn Alloy (단상조직을 갖는 Cu-Zn합금의 고온강도에 미치는 변형속도와 온도의 영향)

  • 권용환;유연철
    • Transactions of Materials Processing
    • /
    • v.4 no.2
    • /
    • pp.159-168
    • /
    • 1995
  • The torsion tests in the range of $550~800^{\circ}C$, $5.0{\times}10^{-3}~5.0{\times}10^0/sec$ were performed to study the effects of strain rate$(\.{\varepsilon})$ and temperature(T) on the hot strength of Cu-Zn alloy. High temperature flow stresses of this alloy increased with increasing $\.{\varepsilon}$ and/or decreasing T, and than the more grain refinement could be obtained. The flow curves exhibited a peak followed by a steady steady state regime as a result of dynamic recrystallization. The hot strength dependence of $\.{\varepsilon}$ and T was described by a hyperbolic sine law, $\.{\varepsilon}=A(sinh0.017{\sigma})^4.81$exp(-216KJ/mol). Hot strength could be reduced at the arbitary condition, $\.{\varepsilon}$ and T, by constitutive parameter Z(Zenner-Hollomon parameter), $Z=A(sinh{\alpha}{\sigma})^n=\.{\varepsilon}$exp(Q/RT).

  • PDF

Prediction of Supersonic Jet Impingement on Flat Plate and Its Application (초음속 충돌제트에 대한 수치적 연구와 응용)

  • Lee K. S.;Hong S. K.;Park S. O.;Bae Y. S.
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.225-228
    • /
    • 2002
  • Supersonic jet impingement on a flat plate has been investigated to show the flow physics for different jet heights and to demonstrate the adequacy of the characteristics-based flux-difference Wavier-Stokes code Current study also compares the steady-state solutions obtained with variable CFL number for different grid spacing with the time-accurate unsteady solutions using the inner iterations, displaying a good agreement between the two sets of numerical solutions. The unsteady nature of wall fluctuations due to bouncing of the plate shock is also uncovered for high pressure ratios. The methodology is then applied to a complex vertical launcher system where the jet plume hits the bottom wail, deflects into the plenum and eventually exits through the vertical uptake. Flow structures within vertical launcher system are captured and solutions are partially verified against the flight test data. Present jet impingement study thus shows the usefulness of CFD in designing a complex structure and predicting flow behavior within such a system.

  • PDF

현장공기분사공정법(IAS)을 이용한 공기 영향반경과 흐름 양상 연구

  • 이준호;박갑성
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.213-217
    • /
    • 2004
  • Laboratory scale study for an area of influence and flowing aspect of groundwater saturated zone was conducted for three sediment grains. On the AMG(Average Modal diameter Grains) 0.34, 1.38, 3.89mm diameter samples, the affected area of the aquifer were 15.2, 37.0, 30.0%/m2 each. Air flow for AMG 0.34mm diameter grain size provides indication of pattern of channelized air flow in saturated zone and expansion state in above saturated zone. For AMG of 1.38, 3.89mm diameter grains, air flow are pervasive air flow, forming a symmetrical cone of influence around the injection point. And also AMG 1.38, 3.89mm diameter samples show onset of collapse and approach to steady state in above saturated zone, respectively. In this study, optimal sites for in situ air sparging, may be grain diameters between about AMC 1.5~2.5mm diameter.

  • PDF