• Title/Summary/Keyword: stator winding

Search Result 425, Processing Time 0.025 seconds

Magnetization Fault Diagnosis of Concentrated Winding BLDC Motors for Compressor (압축기용 집중권 BLDC 전동기의 착자 불량 진단)

  • Lee, Kwang-Woon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.3
    • /
    • pp.197-203
    • /
    • 2009
  • This paper presents a novel method to diagnose magnetization faults produced during magnetization process using stator coils of a brushless dc motor with concentrated windings. It is demonstrated that the stator coil magnetization faults can cause a drop of energy efficiency of the brushless dc motor through computer simulations using a magnetization fault model and efficiency test using compressors. The proposed method diagnoses the stator coil magnetization faults by using an inverter during the brushless dc motor driving test after the magnetization process is completed. An experimental study on the brushless dc motor for compressor shows that the stator coil magnetization faults can be detected with high sensitivity.

Primary Resistance Compensation of Linear Induction Motor Using Thermocouple (Thermocouple을 이용한 선형 유도전동기의 1차측 저항 보상)

  • Kim, Kyung-Min;Park, Seung-Chan
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.742-747
    • /
    • 2006
  • This paper describes online stator-resistance estimation of a linear induction motor(LIM) with cage-type secondary using direct thrust control(DTC), where the resistance value is derived from stator-winding temperature estimation using thermocouple. In this paper, corrected stator resistance has an error in actuality measurement resistance. So compensation coefficient $\kappa$ which is decided through comparison and verifying several times relation of calculated resistance and measured motor line-line resistance. The stator-winding temperature information can also be used for monitoring, protection, and fault-tolerant control of the machine. Also, this paper reports the LIM's responses of the flux measured by the proposed stator resistance compensation algorithm.

  • PDF

Evaluation of Insulation Diagnostic Test Reliability for Stator Winding of High Voltage Induction Motor (고압유도전동기 절연특성시험의 신뢰도 평가)

  • Lee, Kwang-Ho;Kim, Hyun-Il;Kwak, Hee-Jin;Oh, Bong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1838-1841
    • /
    • 2004
  • This test was performed to assess the correlation between insulation diagnostic tests and breakdown voltage strength of the stator winding of 6.6kV class induction motor in insulation deterioration condition which have been in service for 5 years after being installed in 1998. The insulation diagnostic tests include resistance, polarization index(P.I), dissipation factor(${\triangle}tan{\delta}$), maximum partial discharges(Qmax) and AC breakdown test. we evaluated the correlation between insulation diagnostic test and AC breakdown test for stator winding of high voltage induction motor.

  • PDF

Fault Diagnosis Method of Permanent Magnet Synchronous Motor for Electrical Vehicle

  • Yoo, Jin-Hyung;Jung, Tae-Uk
    • Journal of Magnetics
    • /
    • v.21 no.3
    • /
    • pp.413-420
    • /
    • 2016
  • The permanent magnet synchronous motor has high efficiency driving performance and high power density output characteristics compared with other motors. In addition, it has good regenerative operation characteristics during braking and deceleration driving condition. For this reason, permanent magnet synchronous motor is generally applied as a power train motor for electrical vehicle. In permanent magnet synchronous motor, the most probable causes of fault are demagnetization of rotor's permanent magnet and short of stator winding turn. Therefore, the demagnetization fault of permanent magnet and turn fault of stator winding should be detected quickly to reduce the risk of accident and to prevent the progress of breakdown of power train system. In this paper, the fault diagnosis method using high frequency low voltage injection was suggested to diagnose the demagnetization fault of rotor permanent magnet and the turn fault of stator winding. The proposed fault diagnosis method can be used to check the faults of permanent magnet synchronous motor during system check-up process at vehicle starting and idling stop mode. The feasibility and usefulness of the proposed method were verified by the finite element analysis.

Characteristics of RFCT for Partial Discharge Measurement in the Stator Winding of Rotating Machines (회전기 고정자 권선의 부분방전 측정용 RFCT 특성)

  • Kang, Dong-Sik;Yoon, Dae-Hee;Hwang, Don-Ha;Kim, Yong-Joo;Chang, Ki-Chan;Song, Sang-Ock
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1616-1618
    • /
    • 2001
  • In recent the on-line partial discharge (PD) measurement using sensors, such as EMC, SSC, RTD and RFCT, as an indicator of stator winding insulation condition has been developed. RFCT sensor was placed arounding a grounding lead of surge capacitor to detecting PD. Trend of PD magnitude/phase angle/pulse number over time are useful parameter to diagnosis aging state. We have developed Radio Frequency Current Transformer(RFCT) sensor which is suitable for PD diagnostic measurement in 6.6kV rotating machines. In this paper, we describe the characteristics of RFCT sensor, such as frequency and PD magnitude using 6.6 kV model stator winding in Lab.

  • PDF

Evaluation of Insulation Diagnostic Test Reliability for Stator Winding of High Voltage Induction Motor (고압유도전동기 절연특성시험의 신뢰도 평가)

  • Lee, Kwang-Ho;Kim, Hyun-Il;Kwak, Hee-Jin;Oh, Bong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2004.11d
    • /
    • pp.46-49
    • /
    • 2004
  • This test was performed to assess the correlation between insulation diagnostic tests and breakdown voltage strength of the stator winding of 6.6kV class induction motor in insulation deterioration condition which have been in service for 5 years after being installed in 1998. The insulation diagnostic tests include resistance, polarization index(P.I), dissipation factor(${\Delta}tan{\delta}$). maximum partial discharges(Qmax) and AC breakdown test. we evaluated the correlation between insulation diagnostic test and AC breakdown test for stator winding of high voltage induction motor.

  • PDF

Analysis of winding currents for three phase induction motor connected to single phase supply (단상 전원에 접속된 3상 유도전동기의 권선전류 분석)

  • Kim, Do-Jin;Kang, Sang-Soo;Kang, Nam-Ho;Jwa, Chong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.824-825
    • /
    • 2008
  • This paper analyzes the stator winding currents of a three phase induction motor which is connected to the single phase supply. Two stator configurations, Steinmetz connection and modified Steinmetz connection, are respectively employed. In each case, the phase converter reactance at starting is determined using the condition of minimum voltage unbalance factor. By using this reactance, the stator winding currents of each connection are computed and compared with the results of three phase balanced operation.

  • PDF

Off-Line PD Diagnosis for Stator Winding of Rotating Machines Using a UWB Sensor

  • Lwin, Kyaw-Soe;Park, Noh-Joon;Kim, Hee-Dong;Ju, Young-Ho;Park, Dae-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.263-270
    • /
    • 2008
  • We studied partial discharge detection by sensing electromagnetic waves emitted from the partial discharge source in an HV Rotating Machine using a UWB sensor. In this study, we design a new type of compact low frequency UWB sensor based on micro-strip technology. We also perform many experiments of offline and dismantled testing compared with the existing HFCT on stator winding of the HV generator. We mention the detailed design of a new compact UWB sensor along with the time domain PRPD pattern and frequency domain results of partial discharge in the stator winding of a 6.6kV rotating machine by offline testing performed in a laboratory.

Assessment of Insulation Condition between Diagnosis and Impregnation for Hydro-Generator (수력발전기의 절연보강 전${\cdot}$후 절연상태 비교평가)

  • Byun il-hwan;Lee Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1124-1126
    • /
    • 2004
  • The measurements were performed to assess the insulation deterioration condition of the stator winding of Dae-Cheong hydro-generator ${\sharp}2$ which had been in service after being constructed 1980. After repair of the stator winding insulation. we conducted insulation diagnostic tests which include resistance, polarization index(P. I). AC current, dissipation factor($Tan{\delta}$) and partial discharges ($Q_{max}$). The results of diagnostic tests were compared to the previous records. On the basis of these test results. this paper tried to present the importance of insulation repair for the generator stator winding.

  • PDF

Assessment of Insulation Condition between Diagnosis and Impregnation for Hydro-Generator (대용량 수차발전기의 절연진단과 절연보수 상관관계 평가)

  • Oh, Bong-Keun;Jung, Jin-Dal;Lee, Kwang-Ho;Kim, Hyun-Il;Kwak, Hee-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.39-41
    • /
    • 2004
  • The measurements were performed to assess the insulation deterioration condition of the stator winding of Dae-Cheong hydro-generator #2 which had been in service after being constructed 1980. After repair of the stator winding insulation, we conducted insulation diagnostic tests which include resistance, polarization index(P.I), AC current, dissipation factor($Tan\delta$) and partial discharges ($Q_{max}$). The results of diagnostic tests were compared to the previous records. On the basis of these test results, this paper tried to present the importance of insulation repair for the generator stator winding.

  • PDF