• 제목/요약/키워드: stator core

검색결과 201건 처리시간 0.036초

소형 전동기의 고정자 동특성 예측을 위한 코일 다발의 등가 동적 모형화 (Equivalent Dynamic Modeling of Coil Bundle for Prediction of Dynamic Properties of Stator in Small Motors)

  • 은희광;고홍석;김광준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.540-545
    • /
    • 2001
  • In case of small motors, coil bundle occupies a large portion of stator in view of mass and volume as well as dynamics. It is observed through modal test on the stator of an IPM BLDC (interior permanent magnet brushless direct current) motor that coil bundle wound on the stator core causes the first and second natural frequencies to decrease by about 20-30% compared with those of bare stator. Especially the third natural frequency is newly observed below 3 KHz, which is not observed on the bare stator. It is found that at the third mode the end-coil and the core vibrate out of phase in radial direction. In this paper, the stator is dynamically modeled in terms of the core and the coil bundle consisting of the end-coil and the slot coil based on the above observations for the prediction of dynamic properties. The core can easily be modeled using finite element method with its actual material properties and geometric shape. The concept of equivalent bending stiffness is used for modeling of the end-coil so that predictions may match with the measured natural frequencies for the end-coil cut out of the stator. Although the same concept can be applied to the slot coil, separation of the slot coil from the stator is impractical. Therefore, equivalent bending stiffness of the slot coil is determined through iterative comparisons with the measurements of natural frequencies of the stator with the slot coil in it.

  • PDF

영구자석형 모터의 프릭션 토크 저감을 위한 고정자 철심의 열처리 및 발생원 분석 (Heat Treatment of Stator Core in Permanent Magnet Type Motor for Reduction of Friction Torque and Analysis of Their Cause)

  • 하경호;임양수;권오열;김지현;김재관
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1752-1758
    • /
    • 2008
  • This paper deals with the reduction of friction torque in permanent magnet motors by using the heat treatment of stator core. The stator core is made of electrical steel sheared by the punching die. From the punching process, large mechanical stress acting on the edge of stator tooth induces significant plastic and elastic deformation and then cause the change of magnetization properties. Then, the mechanical and magnetic unbalance in the sheared region of stator tooth produced by material cutting has influence on the friction torque. This paper investigated the effect of the punching process on the magnetization process and the mechanical deformation, and then proposed the stress relief annealing method for the reduction of friction torque among one of motor characteristics.

Measurement of Stator Core Loss of an Induction Motor at Each Manufacturing Process

  • Jeong, Kwangyoung;Ren, Ziyan;Yoon, Heesung;Koh, Chang-Seop
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1309-1314
    • /
    • 2014
  • The measurement of stator core loss for an induction motor at each manufacturing process is carried out in this paper. Iron loss in the stator core of induction motor changes after each manufacturing process due to the mechanical stress, which can cause the deterioration of the magnetic performances. This paper proposes a new iron loss measuring system of the stator core in an induction motor, which can be applied to the case when the distribution of magnetic flux density is not uniform along the magnetic flux path. In the system, the iron loss is calculated based on the induced voltage of the B-search coil and exciting current.

전자기력에 의한 발전기 고정자 코어의 진동 해석 (Vibration Analysis of a Generator-Stator Core Under Electromagnetic Excitation)

  • 김철홍;주영호;박종포
    • 소음진동
    • /
    • 제9권4호
    • /
    • pp.747-753
    • /
    • 1999
  • This paper presents results of vibration analysis of a generator-stator core for 500 MW fossil power plant. A finite element analysis using a commercial S/W is performed to estimate alternating electromagnetic forces, mainly of 120 Hz in 60 Hz machines, acting on the core, and then to calculate forced response of the core. Results are compared with design requirements.

  • PDF

Comparison of Transverse Flux Rotary Machines with Different Stator Core Topologies

  • Lee, Jiyoung;Chung, Shiuk;Koo, Daehyun;Han, Choongkyu
    • Journal of Magnetics
    • /
    • 제19권2호
    • /
    • pp.146-150
    • /
    • 2014
  • The objective of this paper is to provide a comparison between two transverse flux rotary machines (TFRM) with different topologies of stator cores. Depending on how to make stator core with laminated steel sheets, the one topology is 'perpendicular stacking core' and the other is 'separated core'. Both of the two cores have been designed considering 3-dimensional (3-D) magnetic flux path with the same output power conditions, but the core losses are quite different and it causes different magnetic and thermal characteristics. For comparison of these two topologies of stator cores, therefore, core losses have been calculated and used as a heat source in no-load conditions, and the thermal stress has been also calculated. 3-D finite element method has been used for the magnetic field, thermal, and stress analysis to consider the 3-D flux path of the TFRM. After comparing the analysis results of the two topologies, experimental results are also presented and discussed.

EL-CID를 이용한 발전기 고정자 철심의 건전성 평가 (Healthy Assessment of Generator Stator Cores using EL-CID (ELectromagnetic Core Imperfection Detector))

  • 김병래;김희동
    • 전기학회논문지
    • /
    • 제58권2호
    • /
    • pp.356-362
    • /
    • 2009
  • The ELectromagnetic Core Imperfection Detector (EL-CID) test was performed on a small generator in the laboratory and a gas turbine generator in the field to assess the fault condition of generator stator core. Artificial defects with six different sizes were introduced in the small generator. The scan results on six defects show a very large increase in the magnitude of fault current compared to that obtained with a healthy core. After the stator core heats up, a thermal imaging camera was used to detect hot spot on the inner surface of the core for comparison. Several faults were found during inspection of the gas turbine generator with the EL-CID. It has been shown that the existence of a fault can be determined by monitoring the magnitude of fault current.

High-Speed BLDC Motor Design for Suction Fan and Impact on the Loss caused by Core Welding

  • Hong, Hyun-Seok;Kim, In-Gun;Lee, Ho-Joon;Go, Sung-Chul;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.126-133
    • /
    • 2017
  • This paper deals with the effects of welding, which is done to fix the stator stack, on a motor in case of fabricating a prototype motor that is manufactured in a small quantity. In the case of a small motor, the stator is designed and fabricated with the segmented core as a way to raise the fill factor of winding wire to the utmost within a limited size. In case of fabrication by welding both inside and outside of the stator in order to fix the segmented-core stator, the effects of stack are ignored, and the eddy current loss occurs. This paper performed the no-load test on an IPM-type BLDC motor for driving the suction fan of a vacuum cleaner, which was manufactured by using a segmented-core stator. As a result of the test, it was found that input power more than expected was supplied. To analyze the effects of welding by using the finite element analysis method and verify them experimentally, a stator was re-manufactured by bonding, and input power supplied during the no-load test was compared.

사각 고정자 철심을 가지는 삼상 유도전동기의 고정자 철심 절단 각에 따른 전류 특성 연구 (The Study on Current Characteristic according to Core Cutting Degree in Three-Phase Induction Motor with Rectangular Stator Core)

  • 임종빈;김승주;김광수;이형우;김솔;이주
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1649-1654
    • /
    • 2009
  • Induction motors widely use in industry because structure is simple and hard and cost is generally cheap and they are easy to control. In recently, because of saving steel, ventilation and benefit of frame fixing, rectangular core type induction motors use in industry more and more. This paper presents current characteristic according to stator core cutting degree in three-phase induction motor (IM) with rectangular stator core. According to stator cutting degree, magnetic saturation and paths of flux are changed. Because of these situations, phase currents are unbalance and are produced harmonic components and they cause decrease of efficiency. We analyze each $10^{\circ}$ from $0^{\circ}$ to $30^{\circ}$ using 2-D finite element analysis (FEA). Optimal stator cutting core degree selection supplies stable currents and efficiency improvement. In this paper, loss separation test was executed by IEEE Std. 112-98 Method B and we compare with the result of loss separation by Simulation using FEM and by Experiment.

  • PDF

자기등가회로 기법을 사용한 2상 E-core SRM의 해석에 관한 연구 (Analysis of Two-phase E-core Switched Reluctance Machines Using Magnetic Equivalent Circuit Technique)

  • 이치우
    • 전기학회논문지
    • /
    • 제59권11호
    • /
    • pp.1986-1989
    • /
    • 2010
  • The modification of magnetic structures for an E-core switched reluctance machine (SRM) comprising two segmented stator cores or a monolithic stator core is presented for ease of assembly, good manufacturability, mechanical robustness, and electromagnetic performance improvement. The E-core stator has four small poles with phase windings and two or four large poles (hereafter referred to as common poles), in between. The common poles are shared by both phases for positive torque generation during the entire operation. The E-core SRMs are compared to a conventional two-phase SRM. The comparison includes cost savings, torque, copper and core losses, and efficiency in order to validate the distinct features of the E-core SRMs. Magnetic equivalent circuit (MEC) technique is employed for proving the benefits of the E-core common-pole structure.

전동/발전기 코어에 의한 초전도 플라이휠 에너지 저장장치의 회전손실 특성 평가 (Rotational loss assessment of flywheel energy storage system by Motor/Generator core)

  • 이정필;한영희;정세용;한상철;정년호;성태현
    • 전기학회논문지
    • /
    • 제56권10호
    • /
    • pp.1775-1781
    • /
    • 2007
  • In this paper, the rotational loss of the superconductor flywheel energy storage system (SFES) by motor/generator stator core was assessed. To do this, the vertical axial type SFES with journal type superconductor bearing was manufactured. To quantitatively assess the rotational loss by the stator core, the rotational losses by superconductor bearing and the degree of a vacuum were measured. In case of variation of the inner radius and outer radius of the stator core, the rotational losses were measured. From the experimental results, It is confirmed that the rotational loss can be reduced by means of the optimal stator core design.