• 제목/요약/키워드: station

검색결과 14,035건 처리시간 0.066초

이상기온에 따른 2년생 인삼 신품종 및 계통간 조기발뇌 특성 비교 (Comparison of Early Budding Characteristics in New Varieties and Lines 2-Year-Old Ginseng(Panax ginseng C. A. Meyer) by Regional Unusual Temperature in Cheorwon)

  • 정햇님;허수정;김성일;조윤상;안문섭;김영창;김동휘;차선우;성봉재;한승호;김현호
    • 한국약용작물학회:학술대회논문집
    • /
    • 한국약용작물학회 2012년도 심포지엄 및 춘계학술발표회
    • /
    • pp.165-166
    • /
    • 2012
  • PDF

수동측정기에 의한 대기오염 자동측정망의 지역대표성 조사 및 보완방완에 대한 기초연구 (Evaluation and Complement of the Representativeness of Air Quality Monitoring Stations Using Passive Air Samplers)

  • 우정현;김선태;김정욱
    • 한국대기환경학회지
    • /
    • 제13권6호
    • /
    • pp.415-426
    • /
    • 1997
  • Some arguments have been about over the representativeness of government-run air quality monitoring stations among scholars and non-governmental organizations (NGOs). However, it is not a simple problem to move monitoring stations because of continuity of data and high cost. So it is necessary to complement the monitoring data if it do not represent the ambient air quality properly. The purpose of this study was to evaluate the representativeness of some monitoring stations using passive $NO_2$ samplers and to find a complementary method from linear regression. Two stations were chosen for the evaluation: Shinlim Station was one of the most controversial stations in Seoul and Banpo Station had the best reputation. Air qualities were surveyed at seven points around each monitoring station with consideration of land use and distance. The ratios of the average $NO_2$ levels of the areas to these at the monitoring stations were 1.59 for Shinlim Station and 1.03 for Banpo Station. The differences between the average $NO_2$ levels and those at the monitoring stations were 10.75 ppb for Shilim Station and 0.34 ppb for Banpo Station. The correlation coefficients between the two levels were 0.7668 for Shinlim and 0.7662 for Banpo. The average coefficients of determination $(R^2)$ were 0.61 for Shinlim and 0.61 for Banpo. The Shinlim Station could not represent the air quality of Shinlim-Dong good because it is located in a green area at an outskirt of Shinlim-Dong. But the Banpo Station located in a central residential area of Banpo-Dong showed a fair representativeness. However, air quality turned out to be different with land use such as residential area, green area or road: the air quality data from a monitoring station located at a certain land use should not be interpreted as representing the air quality at any sites around the station. Equations to predict the average $NO_2$ levels of each area from the data from the monitoring stations were presented based on linear regression.

  • PDF

대심도 지하정거장에서 수직구 위치에 따른 수치적 연구 (NUMERICAL STUDY WITH VENT SHAFT POSITION IN UNDERGROUND STATION)

  • 오현주;신대용;이상건;김동현;김찬중
    • 한국전산유체공학회지
    • /
    • 제17권1호
    • /
    • pp.36-43
    • /
    • 2012
  • When a high-speed train passes an underground station, large pressure waves are generated due to the piston effect. These pressure waves can cause the problems of vibration and noise as well as the ear discomfort of passengers at the underground station. This work numerically analyzed the pressure wave generation and propagation in an high-speed railway underground station, and the optimal location for vent shafts was studied to improve the passenger comfort by reducing the magnitude of the pressure wave and its rate of change. The evolution of pressure field in the underground station was calculated using a CFD(Computational Fluid Dynamics) software(Fluent), where the axis-symmetric two-dimensional model verified by Wu was used. And this study is applied to modelling of the underground station and the tunnel from Daegok station A-line of GTX(Great Train Express). From the result, we can have a conclusion that the role of vent shafts respectively were different according to the position in and out the underground station. Also Vent shaft in the underground station widely reduced pressure magnitude. And vent shaft out underground station reduced initial pressure peak value. Double vent shafts installed at tunnel toward station entrance and inside of the tunnel are the most efficient to reduce pressure. and pressure reduction increases according to the number of vent shaft.

부산광역시 지하철 내의 대기오염도 분석 (Analysis of Ambient Air Quality Level in Subway Area in Busan Metropolitan City)

  • Lee, Hwa-Woon;Park, Jong-Kil;Jang, Nan-Sim;Lee, Hee-Ryung;Kim, Hee Man
    • 한국환경과학회지
    • /
    • 제12권2호
    • /
    • pp.207-215
    • /
    • 2003
  • The purpose of this study is to estimate the air quality of subway stations having underground platforms in Busan Metropolitan City, from September to November 2000, over seven times. The places of the investigation include Yonsan-dong station, Somyon station, Busan station, Nampo-dong station, and Dusil station. Samplings were conducted at three points in each station, i.e. gates, ticket gates, and platforms. CO, NO, $NO_2$, and $O_3$ were the main components of air for this analysis. In order to more fully understand station environments, we also measured an air temperature at each point. The results showed that the $O_3$ average concentration of Yonsan-dong station was higher than others with 38~51 ppb. The average concentration of NO was high at the ticket gate and platform at Somyon station (119 ppb, 122 ppb) and Nampo-dong station (102 ppb, 100 ppb). These results show that the air pollution of stations with underground shopping malls were higher than others. At Somyon station having a junction station, NO and $NO_2$ concentration levels of platform-2 (noncrowded) were higher than platform-1 (crowded). This is most likely due to the accumulation of air pollutants and inadequate ventilation systems. To find the relationship of the indoor (platform) and outdoor (gate), we analyzed the I/O ratio. The averages of CO and $O_3$ were both higher than one: 1.16 and 1.82, respectively. In the correlations between each material and the others, NO vs $NO_2$ was the highest with R=0.63. In the correlations between indoor and outdoor, $O_3$ was the highest with R=0.64.

도시철도 역사 위생시설의 유니버설 디자인 기준에 관한 연구 (A Study on Universal Design Guideline of the Urban Railway Station: Public Toilet)

  • 강병근;박광재;김상운;이주형;이주연
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제21권1호
    • /
    • pp.47-56
    • /
    • 2015
  • Purpose : As the number of the transportation poor has increased, the application of Universal Design on urban railway station has recently been focused. However, the current criteria used in domestic areas did not show the characteristic of facilities within urban railway station. Therefore, this study aims to explore the detailed criteria in applying ideas from Universal Design to sanitary facilities, especially toilets within railway station. Method : This study explores the criteria by evaluating findings from previous studies. First, the current situation of sanitary facilities in railway station is assessed. Then, the detailed criteria applicable to railway station toilets are concluded, by reviewing types of transportation poor and principles of Universal Design. Result : Findings from this study are as follows. First, the current criteria applied to railway station toilets lack ideas of Universal Design, so the better criteria applicable to sanitary facilities in railway station are necessary. Second, standard criteria used in domestic areas with newly additional criteria suggest that sanitary facilities should be established according to those criteria. Taken together, the better sanitary facilities should be provided to railway users through the application of Universal Design to railway station toilets. Implication : For the future users in railway station toilets, the additional research on types of diverse space and other sanitary facilities within railway station should have been continued.

부산광역시 지하철역 지하공간의 대기오염 특성 (Analysis of air pollution in subway area of Busan Metropolitan City)

  • 이화운;장난심;곽진;이희령;김희만
    • 한국환경과학회지
    • /
    • 제11권3호
    • /
    • pp.169-176
    • /
    • 2002
  • The purpose of this study is designed to estimate the air quality of subway stations that have the underground platforms in Pusan Metropolitan City, from September to November 2000, over seven times. The subjects include Yonsan-dong station, Somyon station, Pusan station, Nampo-dong station, and Tushil station. The samplings were conducted at three points of each station, i.e. gate, ticket gates, and platforms. The major materials for analysis were CO, NO, NO$_2$, and $O_3$. The experiment was conducted at 7:00 pm with KIMOTO HS-seven Handy sampler and Tedlar Bag of SKC INC(U.S.A). In order to more fully understand station environments, we also measured temperature at each point. The results showed that $O_3$ average concentration at Yonsan-dong station was higher than others with 38~51 ppb. The average concentration of NO was high at ticket gate and platform at Somyon station(119 ppb, 122 ppb), Nampo-dong station(102 ppb, 100 ppb). These results show that the air pollution of stations with underground shopping malls was higher than others. At Somyon station having a junction station, NO and NO$_2$ concentration level of platform-2(noncrowded) was higher than platform-1(crowded). This is most likely due to the accumulation of air pollutants and inadequate ventilation systems.