• 제목/요약/키워드: static structure

검색결과 2,002건 처리시간 0.028초

Multi-objective optimization of anisogride composite lattice plate for free vibration, mass, buckling load, and post-buckling

  • F. Rashidi;A. Farrokhabadi;M. Karamooz Mahdiabadi
    • Steel and Composite Structures
    • /
    • 제52권1호
    • /
    • pp.89-107
    • /
    • 2024
  • This article focuses on the static and dynamic analysis and optimization of an anisogrid lattice plate subjected to axial compressive load with simply supported boundary conditions. The lattice plate includes diagonal and transverse ribs and is modeled as an orthotropic plate with effective stiffness properties. The study employs the first-order shear deformation theory and the Ritz method with a Legendre approximation function. In the realm of optimization, the Non-dominated Sorting Genetic Algorithm-II is utilized as an evolutionary multi-objective algorithm to optimize. The research findings are validated through finite element analysis. Notably, this study addresses the less-explored areas of optimizing the geometric parameters of the plate by maximizing the buckling load and natural frequency while minimizing mass. Furthermore, this study attempts to fill the gap related to the analysis of the post-buckling behavior of lattice plates, which has been conspicuously overlooked in previous research. This has been accomplished by conducting nonlinear analyses and scrutinizing post-buckling diagrams of this type of lattice structure. The efficacy of the continuous methods for analyzing the natural frequency, buckling, and post-buckling of these lattice plates demonstrates that while a degree of accuracy is compromised, it provides a significant amount of computational efficiency.

호이스트 및 크레인에 적용 가능한 안전후크와 X-jog 제품 설계 및 제작 (Product Design and Manufacture on Safety Hook and X-jog for application in Hoist and Crane)

  • 나현호;김도정;최주석;오우준;박제웅;이천호
    • 해양환경안전학회지
    • /
    • 제21권1호
    • /
    • pp.91-96
    • /
    • 2015
  • 본 연구에서는 크레인 작업시 발생하는 재해발생 사례를 토대로 호이스트의 중량물 이탈 방지에 대한 연구를 수행하였으며, 안전고리의 결합으로 구성된 종래의 체결방식을 벗어나 구조물의 무게에 의한 자동 체결 및 결합 방식의 후크 및 특수목적을 가진 X-jog를 설계 및 제작하여 현장에 적용하고자 하였다. 주요 기구부의 3차원 상세설계와 구조해석을 통해 Safety Hook와 X-jog의 미소변형과 허용응력 이하의 구조안정성을 확인하였으며, 안전율은 일반적인 구조설계시 고려되는 안전율 1.2를 상회하는 평균 1.5를 나타냄을 확인하였다. 따라서, 본 연구에서의 Safety Hook와 X-jog는 구조물이 호이스트와 크레인에 부착되어 운용되어질시 구조적 안정성은 충분할 것으로 판단된다.

유체가 채워진 착저신 유연막 구조물에 의한 파랑제어 (Wave Control by Bottom-Mounted and Fluid-Filled Flexible Membrane Structure)

  • 조일형;강창익
    • 한국해안해양공학회지
    • /
    • 제12권3호
    • /
    • pp.139-148
    • /
    • 2000
  • 본 연구에서는 유체가 채워진 착저식 유연막 구조물과 파와의 상호작용 문제를 유탄성 이론을 사용하여 살펴보았다. 먼저 동역학적 문제를 풀기에 앞서 유체로 채워진 유연막 내부에 일정한 압력이 작용하였을 때, 유연막의 형상과 막에 작용하는 초기장력을 정역학문제를 풀어 구한다. 동역학적 문제를 풀기 위하여 유체영역을 내부영역과 외부영역으로 나누어, 내부영역을 유연막을 경계로 영역 1과 영역 2로 다시 나눈다. 내부영역에서는 경계요소법을 사용하여 파동장을 풀고, 외부영역에서는 고유함수전개법을 사용하여 해를 구한다. 두 영역이 만나는 정합면에서 이미 구한 해를 정합시켜 완전한 해를 구한다. 유연막의 거동은 원주 좌표계를 사용하여 유도된 선형화된 막방정식을 사용하여 이때 외력은 영역 1과 영역 2의 압력차로 주어지므로 영역 1과 영역 2의 해는 막방정식을 통하여 연성된다. 유체가 채워진 착저식 유연막 방파제의 성능에 미치는 중요한 변수로는 유연막의 형상(폭, 높이)과 유연막 내부압력, 유체의 밀도이다. 설계변수들을 바꿔가면서 유연막에 의한 파랑제어 효과를 투과율을 통하여 살펴보았다. 또한 파의 입사각도에 따른 파랑제어 효과를 함께 고찰하였다. 수치계산결과는 Ohyama의 실험결과와 비교하였고 두 결과는 정량적인 값 차이가 나지만 정성적으로 일치하고 있음을 확인하였다. 적절히 설계된 유연막은 소형어항 보호용이나 레저용 방파제로 활용할 수 있는 가능성을 발견하였다.

  • PDF

반강접 접합부 배치에 따른 비가새 5층 철골골조구조물의 비탄성 정적해석 (Pushover Analysis of an Unbraced 5-Story Steel Framed Structure for Arrangement of Semi-Rigid Connection)

  • 강석봉;김신애
    • 한국강구조학회 논문집
    • /
    • 제22권4호
    • /
    • pp.325-334
    • /
    • 2010
  • 본 연구에서는 반강접 접합부 배치에 따른 구조물 거동특성을 파악하기 위하여 KBC2005 건축구조설계기준으로 비가새 5층 철골 구조물을 설계하여 모든 접합부를 완전 강접합부과 반강접 접합부로 이상화한 경우 그리고 반강접 접합부를 수직배치 및 수평배치한 경우에 대하여 푸쉬오버 구조해석을 실시하였다. 철골 보 및 기둥의 모멘트-곡률관계는 화이버모델을 이용하여 확인하였으며 반강접 접합부의 모멘트-회전각 관계는 3-매개변수 파워모델을 이용하여 나타내었다. KBC2005 등가정적횡하중을 받는 2차원 구조물에 대한 푸쉬오버 구조해석을 실시하여 지붕충변위, 밑면전단력, 접합부 요구연성도, 소성힌지 발생순서 그리고 초과강도계수, 연성계수, 반응수정계수와 같은 설계계수 등을 확인하였다. 반강접 접합부를 부분적으로 사용하면 모든 접합부에 반강접 접합부를 사용한 골조 보다 큰 강도 및 강성도를 확보 할 수 있었고 모든 접합부에 강접 접합부를 사용한 골조 보다 큰 연성능력을 확보할 수 있었다. 초과강도계수는 기준과 비슷하였지만 반응수정계수는 기준 보다 훨씬 큰 값을 보였다. TSD 접합부는 예제 구조물에서 경제성과 안전성을 확보할 수 있음을 확인할 수 있었다.

항공기 연료흐름분배기 장착 구조물 결함개선 연구 (Study on the Defect Improvement of Fuel Flow Proportioner Install Structure on Aircraft)

  • 최형준;이진원;최재호;박성제
    • 한국산학기술학회논문지
    • /
    • 제21권4호
    • /
    • pp.558-567
    • /
    • 2020
  • 본 연구는 항공기 운용 중 발생하는 구조 결함의 원인을 분석하기 위해 연료흐름분배기 장착 구조물의 결함특성을 확인하고자 한다. 일반적으로 항공기 운용 중 발생하는 체계 진동과 구성품 단일 진동에 의해 구조 결함이 야기된다. 결함을 정의하고 설계 및 운용 분석으로 이어지는 과정을 통해 원인 규명 방법을 제시하고자 한다. 연료흐름분배기는 급격한 유량의 증가로 인한 압력의 변화로 발생되는 진동에 의해 지지구조의 결함이 발생되었다. 지지구조에 발생하는 하중 특성 및 파단면 분석을 통해 초기 균열이 반복하중으로 인해 피로균열이 발생하였다. 연료흐름분배기 지지구조 결함은 항공기 운용분석 결과 기종별 기동 및 비행시간은 균열과 직접적인 상관관계가 적고, 후기연소(A/B) 사용과 관련이 있다. 결함에 대한 개선을 위해 연료흐름분배기 하부 장착 Bracket의 균열 부위에 정적 및 수명해석을 통해 구조 보강형상을 확정하였다. 보강에 대한 분석 결과 구조 강도 최소 마진이 +0.15로 구조 건전성을 확인하였고, 구조 수명 분석결과 해당 부위에 응력이 15Ksi 이하로 작용하였으며 피로 수명이 7,700 Cycle 이상임을 확인하였다.

ANSYS를 이용한 화재 후 온도에 따른 합성보 성능에 관한 해석적 연구 (An Analytical Study on Composite Beam Performance with Post-Fire Temperature Using ANSYS Program)

  • 곽성신;최병정
    • 한국산학기술학회논문지
    • /
    • 제20권1호
    • /
    • pp.391-400
    • /
    • 2019
  • 화재발생 시 구조물의 부재는 온도상승에 의하여 본래의 강성을 잃게 되어 하중 지지력이 감소하게 된다. 구조 부재에 급격한 내력 상실은 구조물의 붕괴 및 인명 피해로 이어질 수 있다. 구조물의 화재 시간이 길어지게 되면 구조 부재에 대한 내력 상실은 더욱 증가하게 된다. 건축물의 붕괴를 방지하기 위하여 부재 손상 여부의 파악은 매우 중요한 과제이나 국내에서 부재의 잔존내력을 진단하고 평가하는 지침이 될 만한 자료는 미비한 실정이다. 따라서 본 연구는 구조 부재 중 합성구조인 합성보를 유한요소해석을 통하여 내화성능을 분석하고자 한다. 합성보 모델링은 한국전력기술의 협조를 받아 원자력 발전소 보조건물(Electrical Penetration Room, EPR)에 사용되는 도면을 바탕으로 수행하였다. 유한요소해석 프로그램인 ANSYS를 이용하여 정해석 단계의 열전달 해석과 구조해석을 수행하였다. 열전달 해석 결과로 얻어진 온도분포를 데이터로 확보하여 구조해석에 열전달해석 결과를 반영시켰다. 잔존성능을 분석하기 위하여 합성보의 온도분포와 열 영향을 받은 구조해석의 최대변위 결과를 도출하여 실험 결과 데이터와 구조해석 결과 데이터를 비교분석하였다.

Seismic behavior of K-type eccentrically braced frames with high strength steel based on PBSD method

  • Li, Shen;Wang, Chao-yu;Li, Xiao-lei;Jian, Zheng;Tian, Jian-bo
    • Earthquakes and Structures
    • /
    • 제15권6호
    • /
    • pp.667-685
    • /
    • 2018
  • In eccentrically braced steel frames (EBFs), the links are fuse members which enter inelastic phase before other structure members and dissipate the seismic energy. Based on the force-based seismic design method, damages and plastic deformations are limited to the links, and the main structure members are required tremendous sizes to ensure elastic with limited or no damage. Force-based seismic design method is very common and is found in most design codes, it is unable to determine the inelastic response of the structure and the damages of the members. Nowadays, methods of seismic design are emphasizing more on performance-based seismic design concept to have a more realistic assessment of the inelastic response of the structure. Links use ordinary steel Q345 (the nominal yielding strength $f_y{\geq}345MPa$) while other members use high strength steel (Q460 $f_y{\geq}460MPa$ or Q690 $f_y{\geq}690MPa$) in eccentrically braced frames with high strength steel combination (HSS-EBFs). The application of high strength steels brings out many advantages, including higher safety ensured by higher strength in elastic state, better economy which results from the smaller member size and structural weight as well as the corresponding welding work, and most importantly, the application of high strength steel in seismic fortification zone, which is helpful to popularize the extensive use of high strength steel. In order to comparison seismic behavior between HSS-EBFs and ordinary EBFs, on the basis of experimental study, four structures with 5, 10, 15 and 20 stories were designed by PBSD method for HSS-EBFs and ordinary EBFs. Nonlinear static and dynamic analysis is applied to all designs. The loading capacity, lateral stiffness, ductility and story drifts and failure mode under rare earthquake of the designs are compared. Analyses results indicated that HSS-EBFs have similar loading capacity with ordinary EBFs while the lateral stiffness and ductility of HSS-EBFs is lower than that of EBFs. HSS-EBFs and ordinary EBFs designed by PBSD method have the similar failure mode and story drift distribution under rare earthquake, the steel weight of HSS-EBFs is 10%-15% lower than ordinary EBFs resulting in good economic efficiency.

다채널 저가 GNSS 측위 모듈기반 RTK 측량의 효용성 평가 (Evaluating of the Effectiveness of RTK Surveying Performance Based on Low-cost Multi-Channel GNSS Positioning Modules)

  • 김치훈;오성종;이용창
    • 지적과 국토정보
    • /
    • 제52권2호
    • /
    • pp.53-65
    • /
    • 2022
  • GNSS 위성측위시스템의 고도화에 따라 다채널 GNSS 수신기, 다 주파 외장안테나 및 모바일 앱(App)기반 공개형 측위해석 소프트웨어 등 사용자 부문에서도 정확성과 경제성을 반영한 하드웨어 및 운용 소프웨어의 모듈(Module)화가 구현되어 사용자의 목적에 따라 능동적 구성방식(DIY, Do it yourself)의 다채널 GNSS RTK 측위가 가능하다. 특히, Multi-GNSS 위성의 활용 인프라가 확대되고 다양한 모듈의 조합에 따른 활용·확대의 잠재성이 부각되면서 다채널 저가 GNSS 수신기 모듈의 활용에 대한 관심이 점차 높아지고 있다. 본 연구의 목적은 다양한 형태로 대중시장에 등장하고 있는 다채널 저가 GNSS 수신기를 검토하고 다채널 저가 GNSS 측위 모듈 기반 RTK 측량 시스템(이하, "다채널 GNSS RTK 모듈 측위 시스템")을 구성하여 행정안전부의 "주소정보시설 조사사업"의 활용 방안을 분석하고 활용 가능성을 평가하였다. 이를 위해 U-blox사의 F9P 칩셋, 안테나, GNSS 관측자료의 Ntrip 전송 및 RTK 측위용 해석 앱(App) 등 관련 모듈을 스마트폰을 매개로 조합, 저가형 "다채널 GNSS RTK 모듈 측위 시스템"을 구성하고 원형 궤적에 대한 동적측위 실시 및 주소정보시설을 대상으로 정적측위를 수행하였다. 실험대상지 내 고정점 5점을 대상으로 측지용 수신기 정적측량성과와 비교분석한 결과 평균 ± 1.2cm의 표준편차로 양호한 정적측량성과를 획득할 수 있었다. 또한, 드론영상 해석으로 구성한 정사영상 내 원형구조물의 외곽선에 대한 검사점과 저비용 RTK GNSS 수신기의 동적측량 궤적과 비교한 결과, 평균 ± 2.5cm의 표준편차로 매우 근접한 궤적 성과를 확인할 수 있었다. 특히, 주소정보시설에 적용한 결과, 고가의 상업용 측지형 수신기 대비 저렴한 비용으로 공간정보구축의 효용성을 검증할 수 있었으므로 지적분야에서 본 연구에서 구성한 "다채널 GNSS RTK 모듈 측위 시스템"의 다양한 활용성이 기대된다.

진동기 얕은기초에 추가되는 동적 연직하중 산정을 위한 모형실험 방안 연구 (A Study on the Model Test for Estimating Dynamic Vertical Load Added to Shallow Foundation for Machine)

  • 하익수;유민택
    • 한국지반공학회논문집
    • /
    • 제36권11호
    • /
    • pp.157-165
    • /
    • 2020
  • 현재 국내외에서는 진동기계기초에 진동으로 발생하는 추가 연직 동하중을 산정하고 설계함에 있어서 명확하게 제시된 기준이나 이론이 정립되어 있지 않아 국내의 경우, 심각한 진동조건이 아님에도 불구하고 진동에 의한 추가 동하중을 정적하중의 최대 100%로 간주하는 극히 보수적인 설계가 이루어지고 있다. 본 연구의 목적은 연직 기계진동으로 인하여 정하중외에 추가적으로 발생하는 동적하중의 정량적 크기를 평가하기 위한 모형실험 방안을 제시하는 것이다. 실내 모형실험의 기초실험으로, 제한된 크기의 모형 토조 내에서 발생할 수 있는 진동 반사파의 영향을 분석 및 보완하였고, 제작한 모형 진동기계기초의 고유진동수를 산정하여 실험 시 공진영향을 최소화하였다. 제안된 기법을 적용한 본 모형실험을 수행하여, 중간 조밀도의 모래 기초지반에 놓인 기계진동 얕은 기초에 기계진동에 의해 발생하는 추가적인 동하중의 정량적 크기를 평가해 보았다. 모형실험결과로부터, 현재 국내외에서 제시하고 있는 설계기법의 적합성을 논의해 보았다.

한국형 공기주입 이중피복 플라스틱온실의 설계기술 개발 (Development of Design Technology of Korean Style Air-Inflated Double-Layer Plastic Greenhouse)

  • 이현우;심상연;남효석;남상운;김영식
    • 생물환경조절학회지
    • /
    • 제18권3호
    • /
    • pp.185-191
    • /
    • 2009
  • 본 연구는 우리나라의 기상환경에 적합한 한국형 공기주입 이중피복 플라스틱 온실을 설계하는데 필요한 기초자료를 제공하기 위하여 실험용 공기주입 이중피복 플라스틱 온실을 제작하여 작동실험을 실시하고 온실내부의 환경변화를 분석하였다. 온실의 피복재를 설치할 때 시공기술이 부족하여 밀폐도가 많이 떨어지는 것으로 나타났기 때문에 이중피복 공기충의 정압을 적절하게 유지하기 위해서는 높은 밀폐도를 유지할 수 있는 피복재 설치기술과 관련 자재의 개발이 요구되었다. 관행의 이중피복온실보다 공기주입 이중피복온실이 단열효과가 더 우수하였으며, 특히 아치형 지붕형태의 공기주입 이중피복온실이 복숭아 형태의 관행온실에 비해 $2^{\circ}C$ 정도 높아 보온효과가 상당히 우수한 것으로 나타났다. 시공성이 우수하고 밀폐도를 높일 수 있는 피복방식은 온실위에 피복재를 덮은 상태에서 여유길이를 두지 않고 자연스럽게 고정시키는 것이 가장 바람직하였다. 다른 조건들이 동일한 공기주입 이중피복 단동온실의 경우 복숭아형 지붕온실에 비해 아치형 지붕온실에서 광투과율이 더 높은 것으로 나타났다. 3연 동 온실의 경우에는 관행 이중피복온실에 비해 공기주입 이중피복온실이 광투과율이 더 높은 것으로 나타났으며, 이는 주로 골조율과 이중피복재간의 간격 때문인 것으로 판단되었고, 이에 대한 자세한 원인은 앞으로 추가적인 실험을 통해 검증할 예정이다. 결로의 발생현상을 가시적으로 비교한 결과 관행온실에서 더 많은 결로가 발생함을 확인할 수 있었다 그러나 정량적인 비교를 위해서는 장기간의 관측과 이론적인 분석이 필요할 것으로 판단되며, 향후 더 자세한 실험을 통해 규명할 예정이다.