• Title/Summary/Keyword: state-building

Search Result 1,480, Processing Time 0.026 seconds

A Study on the Critical Safety Management Buildings and factors by Analyzing the Actual State of Building Safety Management (건축물 안전관리 실태분석을 통한 중점안전관리 대상 및 요소 설정에 관한 연구)

  • Kim, Eun-Hee
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.4
    • /
    • pp.37-44
    • /
    • 2019
  • According to the statistical surveys and studies, insufficient maintenance in the use of existing buildings caused fire and collapse accidents. In this respect, I analyzed the data managed by the current building maintenance and inspection system to find out the actual state of safety management and proposed two significant results. First, regarding the state of the buildings, the safety management status of the small-sized ones, where 20 years or more passed after construction, is the worst and a priority improvement plan is required. Second, there are eight deeply concerning factors for the fire incidents and collapse accidents of buildings. In the order of high risk, these factors are structural strength (seismic design), exterior wall finishing material, basement floor, interior finishing materials, other evacuation facilities, corridors stairs entrances, rooftop, fire partition. We need to have more special designs and management plans regarding high-risk factors as a system to prevent accidents in the building.

Moment-curvature hysteresis model of angle steel frame confined concrete columns

  • Rong, Chong;Tian, Wenkai;Shi, Qingxuan;Wang, Bin;Shah, Abid Ali
    • Structural Engineering and Mechanics
    • /
    • v.83 no.1
    • /
    • pp.19-29
    • /
    • 2022
  • The angle steel frame confined concrete columns (ASFCs) are an emerging form of hybrid columns, which comprise an inner angle steel frame and a concrete column. The inner angle steel frame can provide axial bearing capacity and well confining effect for composite columns. This paper presents the experimental and theoretical studies on the seismic behaviour of ASFCs. The experimental study of the 6 test specimens is presented, based on the previous study of the authors. The theoretical study includes two parts. One part establishes the section analysis model, and it uses to analyze section axial force-moment-curvature. Another part establishes the section moment-curvature hysteresis model. The test and analysis results show that the axial compression ratio and the assembling of steel slabs influence the local buckling of the angle steel. The three factors (axial compression ratio, content of angle steel and confining effect) have important effects on the seismic behaviour of ASFCs. And the theoretical model can provide reasonably accurate predictions and apply in section analysis of ASFCs.

A Study on the Prescriptions of American Codes for Straw Bale Structures and the Legislation Direction of Korean Straw Bale Code (미국 짚단벽구조 법규 분석 및 국내의 법제화 방향 연구)

  • Kim, Jeong-Gyu
    • KIEAE Journal
    • /
    • v.9 no.2
    • /
    • pp.91-98
    • /
    • 2009
  • The purpose of this study is analyzing the prescriptions of American codes for straw bale structures and proposing the legislation direction of Korean building code. The process of this study is as follows: (1) To set up the legislation direction of straw bale code of Korea, this study investigated the current state and features of straw bale houses in Korea, and looked into the worldwide status of straw bale codes and permitting. (2) To provide basic data for the legislation of Korean straw bale code or guideline, this study analyzed American codes for straw bale structures like the Tucson/Pima County Arizona Building Code Appendix Chapter 72 - Straw-Bale Structures, California State Guidelines for Straw-Bale Structures, New Mexico Standards for Non-load Bearing Baled Straw Construction, Oregon State Residential Code Appendix M - Straw-Bale Structures and so on. The analysis items are the scope of rule application, material specifications, requirements for straw bale walls/foundations and construction requirements. (3) On the base of analysis of American straw bale codes, this study proposed the legislation process and direction of Korean straw bale code and guideline.

Verification of a tree canopy model and an example of its application in wind environment optimization

  • Yang, Yi;Xie, Zhuangning;Tse, Tim K.T.;Jin, Xinyang;Gu, Ming
    • Wind and Structures
    • /
    • v.15 no.5
    • /
    • pp.409-421
    • /
    • 2012
  • In this paper, the method of introducing additional source/sink terms in the turbulence and momentum transport equations was applied to appropriately model the effect of the tree canopy. At first, the new additional source term for the turbulence frequency ${\omega}$ equation in the SST k-${\omega}$ model was proposed through theoretical analogy. Then the new source/sink term model for the SST k-${\omega}$ model was numerically verified. At last, the proposed source term model was adopted in the wind environment optimal design of the twin high-rise buildings of CABR (China Academy of Building Research). Based on the numerical simulations, the technical measure to ameliorate the wind environment was proposed. Using the new inflow boundary conditions developed in the previous studies, it was concluded that the theoretically reasonable source term model of the SST k-${\omega}$ model was applicable for modeling the tree canopy flow and accurate numerical results are obtained.

A Study on the Legislation Types and Prescriptions of American Earth Building Codes (미국 흙건축 법규의 법제화 유형 및 규제내용 분석)

  • Kim, Jeong-Gyu
    • KIEAE Journal
    • /
    • v.8 no.3
    • /
    • pp.19-26
    • /
    • 2008
  • The purpose of this study is to analyze the legislation types and prescriptions of American earth building codes. The process of this study is as follows: (1) To understand the legislation background of American earth building codes, this study investigated the history and present state of earth building techniques which is used in USA. (2) To understand the legislation method and procedure of American earth building codes, this study investigated the legislation system of American building codes and the process of model building codes development and adoption. (3) To provide basic data for the legislation of Korean earth building codes or guidelines, this study analyzed American earth building codes about adobe, compressed earth block and rammed earth. The result of this study is as follows: (1) To meet need of a single coordinated set of national model building codes in the United States, the nation's three model code groups decided to form the International Code Council and the first edition of the International Building Code was published in 1997. In the International Building Code there are prescriptions on adobe construction. (2) There are three legislation types of earth building codes in USA. First is to use prescriptions of International Building Code on adobe construction. Second is that State governments establish and issue a separate document under its own title. The last is that local jurisdictions adopt International Building Code with amendments or additional rules. (3) On the base of analysis of American earth building codes, this study proposed the legislation process and direction of Korean earth building codes and guidelines.

SUSTAINABLE AND ENVIRONMENTALLY RESPONSIBLE DESIGN USING BIM: A CASE STUDY OF A RESIDENTIAL PROJECT

  • Hyunjoo Kim;Kwok K. Tam
    • International conference on construction engineering and project management
    • /
    • 2011.02a
    • /
    • pp.84-87
    • /
    • 2011
  • This paper describes the application of the three sustainable design elements for a residential project in the county of Los Angeles, USA. The first design element is the green building design in which a base model will be created using the Autodesk REVIT MEP program for the analysis by Building Information Modeling (BIM) for the energy analysis modeling process to determine the energy savings for each of the recommended design features. The second element is the Low Impact Development design for the site design using specialty material and structural devices for infiltration and recycling of storm water for reuse. The third element is the application of drought tolerant plant species in the site's landscaping design as a means to conserve water. The construction cost associated with the application of these three elements will be reviewed to determine the practicality and effectiveness of this sustainable design approach.

  • PDF

Health monitoring of multistoreyed shear building using parametric state space modeling

  • Medhi, Manab;Dutta, Anjan;Deb, S.K.
    • Smart Structures and Systems
    • /
    • v.4 no.1
    • /
    • pp.47-66
    • /
    • 2008
  • The present work utilizes system identification technique for health monitoring of shear building, wherein Parametric State Space modeling has been adopted. The method requires input excitation to the structure and also output acceleration responses of both undamaged and damaged structure obtained from numerically simulated model. Modal parameters like eigen frequencies and eigen vectors have been extracted from the State Space model after introducing appropriate transformation. Least square technique has been utilized for the evaluation of the stiffness matrix after having obtained the modal matrix for the entire structure. Highly accurate values of stiffness of the structure could be evaluated corresponding to both the undamaged as well as damaged state of a structure, while considering noise in the simulated output response analogous to real time scenario. The damaged floor could also be located very conveniently and accurately by this adopted strategy. This method of damage detection can be applied in case of output acceleration responses recorded by sensors from the actual structure. Further, in case of even limited availability of sensors along the height of a multi-storeyed building, the methodology could yield very accurate information related to structural stiffness.

Development of Cartography and State-building in France from the Sixteenth Century to the Eighteenth Century (프랑스 지도학의 발달과 국가 형성 - 16세기에서 18세기까지 -)

  • Jung, In-Chul
    • Journal of the Korean Geographical Society
    • /
    • v.41 no.5 s.116
    • /
    • pp.545-560
    • /
    • 2006
  • The purpose of this study is to investigate the relationship between the development of French state and the development of cartography from the sixteenth century to the seventeenth century. For this, firstly, the development of military maps as a means for the defense and expansion of territory was examined. Secondly, the development of overseas maps as an aid for colonial expansion was considered. Thirdly, the development of national maps as a representation of the state was examined. Fourthly, the development of atlas mapping as a means for establishing national consciousness was considered. And finally, the role of maps in state building was discussed.

Dynamic Characterization of Sub-Scaled Building-Model Using Novel Optical Fiber Accelerometer System

  • Kim, Dae-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.6
    • /
    • pp.601-608
    • /
    • 2011
  • This paper presents the damage assessment of a building structure by using a novel optical fiber accelerometer system. Especially, a sub-scaled building model is designed and manufactured to check up the feasibility of the optical fiber accelerometer for structural health monitoring. The novel accelerometer exploits the moir$\acute{e}$ fringe optical phenomenon and two pairs of optical fibers to measure the displacement with a high accuracy, and furthermore a pendulum to convert the displacement into acceleration. A prototype of optical fiber accelerometer system has been successfully developed that consists of a sensor head, a control unit and a signal processing unit. The building model is also designed as a 4-story building with a rectangular shape of $200{\times}300$ mm of edges. Each floor is connected to the next ones by 6 steel columns which are threaded rods. Basically, a random vibration test of the building model is done with a shaker and all of acceleration data is successfully measured at the assigned points by the optical fiber accelerometer. The experiments are repeated in the undamaged state and the damaged state. The comparison of dynamic parameters including the natural frequencies and the eigenvectors is successfully carried out. Finally, the optical fiber accelerometer is proven to be prospective to evaluate dynamic characteristics of a building structure for the damage assessment.

On the domain size for the steady-state CFD modelling of a tall building

  • Revuz, J.;Hargreaves, D.M.;Owen, J.S.
    • Wind and Structures
    • /
    • v.15 no.4
    • /
    • pp.313-329
    • /
    • 2012
  • There have existed for a number of years good practice guidelines for the use of Computational Fluid Dynamics (CFD) in the field of wind engineering. As part of those guidelines, details are given for the size of flow domain that should be used around a building of height, H. For low-rise buildings, the domain sizes produced by following the guidelines are reasonable and produce results that are largely free from blockage effects. However, when high-rise or tall buildings are considered, the domain size based solely on the building height produces very large domains. A large domain, in most cases, leads to a large cell count, with many of the cells in the grid being used up in regions far from the building/wake region. This paper challenges this domain size guidance by looking at the effects of changing the domain size around a tall building. The RNG ${\kappa}-{\varepsilon}$ turbulence model is used in a series of steady-state solutions where the only parameter varied is the domain size, with the mesh resolution in the building/wake region left unchanged. Comparisons between the velocity fields in the near-field of the building and pressure coefficients on the building are used to inform the assessment. The findings of the work for this case suggest that a domain of approximately 10% the volume of that suggested by the existing guidelines could be used with a loss in accuracy of less than 10%.