• 제목/요약/키워드: start-up transformer

검색결과 8건 처리시간 0.017초

최소 컷셋법에 의한 화력발전소 기동전원의 신뢰도 예측에 관한 연구 (A Study on the Reliability Evaluation of Start-up Power Supply in Fossil Power Plant by Minimal Cut-Set Method)

  • 최규식
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권4호
    • /
    • pp.358-364
    • /
    • 1999
  • The auxiliary transformers or start-up/stand-by transformer(s) are installed against the start-up and shut-down of generator and emergency status in fossil power plant. The on-site power supply configuration using these transformers must be determined, considering configuration requirements, site characteristics, reliability and availability severely because it is remarkably important for safety and ecfonomy of plant. The auxiliary or start-up/stand-by power supply configuration has been determined considering only safety requirements and construction cost until now in Korea. This paper presents general theorems for the reliability estimation and proposes 2-unit based 4 alternatives for the start-up power supply stystem of 500㎿ standardized fossil power plant. The reliability and unavailability of equipment, system and configuration are determined using minimal cut-set methodology. The optimized plan of 4 alternatives is determined based on this ultimate reliability and unavailability.

  • PDF

FTA기법에 의한 원전기동전원의 이용율 예측에 관한 연구 (A Study on the Availability Prediction of Start-up Power Supply in Nuclear Power Plant by FTAMethod)

  • 최규식
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권5호
    • /
    • pp.517-523
    • /
    • 1999
  • The Start-up transformers or on-site stand-by transformers are installed for the start-up and shut-down of generator and emergency status in unclear power plant. The on-site power supply configuration using these transformers must be detemined by considering configuration requirements, site characteristics, reliability and availability severely because it is remarkably important for safety and benefit of plant. The start-up or stand-by power supply configuration has been determined considering only safety requirements and construction cost up to now in Korea. I study various reliability estimating methods for the prediction of availability, and estimate the unavailability for the start-up power supply system of two 1,000㎿ unclear power plants. I also detemine the reliability and unavailability and unavailavility of equipment, system and configuration using FTA method.

  • PDF

전자레인지용 LLC 공진형 인버터의 기동 제어 (Start-up Control of LLC Resonant Inverter for Microwave Oven Application)

  • 강계룡;김흥근;차헌녕
    • 전력전자학회논문지
    • /
    • 제22권5호
    • /
    • pp.463-468
    • /
    • 2017
  • One of the most critical part for magnetron driving in microwave oven is start-up control. For this, switching frequency of resonant inverter should be carefully controlled in order to supply sufficient power to the filament of the magnetron and to prevent rectifier diode from destruction caused by the excessive voltage across them. This paper proposes a novel start-up control strategy for LLC resonant inverter for microwave oven considering the non-oscillation mode time and the magnetron voltage during the start-up process. The validity of the proposed method is verified through the experiment with 1,200W microwave oven using LLC resonant inverter.

The Neural-Fuzzy Control of a Transformer Cooling System

  • Lee, Jong-Yong;Lee, Chul
    • International Journal of Advanced Culture Technology
    • /
    • 제4권2호
    • /
    • pp.47-56
    • /
    • 2016
  • In transformer cooling systems, oil temperature is controlled through the use of a blower and oil pump. For this paper, set-point algorithms, a reset algorithm and control algorithms of the cooling system were developed by neural networks and fuzzy logics. The oil inlet temperature was set by a $2{\times}2{\times}1$ neural network, and the oil temperature difference was set by a $2{\times}3{\times}1$ neural network. Inputs used for these neural networks were the transformer operating ratio and the air inlet temperature. The inlet set temperature was reset by a fuzzy logic based on the transformer operating ratio and the oil outlet temperature. A blower was used to control the inlet oil temperature while the oil pump was used to control the oil temperature difference by fuzzy logics. In order to analysis the performance of these algorithms, the initial start-up test and the step change test were performed by using the dynamic model of a transformer cooling system. Test results showed that algorithms developed for this study were effective in controlling the oil temperature of a transformer cooling system.

고압 나트륨램프용 자려식 전자식 안정기의 신호 증폭형 게이트 구동회로 (Signal Amplifying Gate Driver of Self-Excited Electronic Ballast for High Pressure Sodium (HPS) Lamp)

  • 윤용식;조규형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.1304-1306
    • /
    • 1996
  • A regenerative signal amplifying gate driver of self-excited electronic ballast is presented. It can be used for high pressure sodium (HPS) lamp without auxiliary external ignitor. Since the HPS lamp requires very high ignition voltage at start up, the resonant frequency of the circuit must be increased to obtain high voltage oscillations in spite of relatively small resonant current. The presented gate driver amplifies the current of gate drive transformer and raises the gate-source voltage Quickly to turn on the MOSFET switches. Hence, the resonant frequency can be increased more than 100kHz. The HPS lamp used in the simulation and experiment has the rating of 400W input power at 220V input ac voltage source. The experiments show that the resonant frequency is above 150kHz at start up.

  • PDF

Primary Restorative Transmission Line Selection for Myanmar's Electric Power System

  • Kim, Yong-Hak;Song, In-Jun;Jang, Byung-Tae;An, Yong-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권2호
    • /
    • pp.191-196
    • /
    • 2010
  • Power system restoration following a massive or complete blackout starts with energizing the primary restorative transmission system. During this primary restoration process, unexpected overvoltage may happen due to nonlinear interaction between the unloaded transformer and the transmission system. In the case of the Myanmar electric power system, there are so many wide outage experiences, including complete blackout cases, caused by 230kV line faults and so on. Consequently, Myanmar's system operators have been well trained to deal with wide blackouts. Howver, system blackout restoration has been conducted by relying on the experience of only a few specialists. So, more scientific analysis is required to meet the requirements necessary to ensure fast and reliable system restoration. This paper presents analytical results on the primary restorative transmission system of Myanmar, focusing on the problems during the early restoration process. Methodologies are presented that handle load pick-up, terminal voltage and the reactive capability limitation of black-start generators to compensate the Ferranti effect. Static and dynamic simulation with the PSSolution and EMTDC programs respectively for the six cases are performed in order to select the primary restorative transmission lines.

제주계통에서 동기조상기 기동에 따른 전압안정도 영향 검토 (Analysis of Impact on Voltage Stability by Starting Synchronous Condenser in Jeju AC Network)

  • 최순호;이성두;김찬기
    • 전기학회논문지
    • /
    • 제64권1호
    • /
    • pp.23-28
    • /
    • 2015
  • Two old synchronous condensers in Jeju are being replaced by new machines to operate Jeju AC network with Haenam-Jeju HVDC system stably. Before new synchronous condensers operate on site, voltage stability analysis is conducted to verify stable operation of jeju AC network. Through impedance analysis of the synchronous machine, transformer and ac network, the equivalent circuit is constructed and the voltage drop during start-up is calculated. Then, PSS/E fault analysis is performed to acquire short-circuit capacity according to the generator operation scenarios. Voltage variation when starting synchronous condenser is simulated in PSCAD/EMTDC and satisfies the operating condition of jeju AC network and HVDC #1 system.

낮은 변압기 턴비를 갖는 고승압.대전력용 3상 ZVS DC-DC컨버터 (Three-Phase ZVS DC-DC Converter with Low Transformer Turn Ratio for High Step-up and High Power Applications)

  • 김준근;박찬수;최세완;박가우
    • 전력전자학회논문지
    • /
    • 제16권3호
    • /
    • pp.242-249
    • /
    • 2011
  • 제안하는 컨버터는 부스트 하프브리지-전압 더블러를 각각 병렬-직렬로 연결하여 출력전력 및 출력전압을 증대시키므로 고승압 대전력 응용에서 소자의 선정이 용이하다. 특히 고주파변압기 턴 비를 작게 할 수 있고 DC 오프셋이 제거되어 최적의 변압기 설계가 가능하며, 3개의 코아로 전력이 분배되어 Low Profile 및 열 분산에 유리하다. 제안하는 컨버터는 전 영역(0 ∼ 1)의 듀티 사용으로 스타트업 및 추가의 클램프회로가 필요 없으며 입력전압 변동이 큰 응용에 적합하다. 또한 넓은 듀티영역에서 스위치의 ZVS 턴온과 다이오드의 ZCS 턴온 턴오프가 성취되므로 고효율을 달성할 수 있다. 제안하는 컨버터를 5 kW급 시작품으로 검증하였다.