• Title/Summary/Keyword: stapler

Search Result 71, Processing Time 0.021 seconds

Clinical Evaluation and Prevention of Complications of Esophagojejunal Anastomotic Site after Total Gastrectomy (위 전절제술 후 식도 공장 문합부 합병증에 관한 연구)

  • Park, Ki-Ho;Jung, Soon-Jai
    • Journal of Gastric Cancer
    • /
    • v.4 no.2
    • /
    • pp.121-125
    • /
    • 2004
  • Purpose: Esophagojejunal anastomotic complications after a total gastrectomy include leakage, stenosis, bleeding, and abscess formation. Especially, the mortality rate for esophagojejunal anastomotic leakage is $80\%$. Although these complications hare been reduced by the usage of the EEA stapler, they are still serious and depend on various factors: the surgeon's experience, the stage of disease, the extent of surgical intervention, the method of operation, and the patient. Some local factors, such as vascularization of the graft, traction on the anastomosis suture line, and local infections, have been implicated as contributing to these complications. Materials and Methods: During the period $1995\∼2003$, of the 850 gastrectomies for gastric carcinomas, 171 were intra-abdominal total gastrectomies. All of these 171 operations were performed by one surgeon using a routine D2 lymph-node dissection and a 25-mm EEA stapler on an antecolic end-to-side esophagojejunostomy. In the 77 cases a seromuscular reinforced suture at the esophagojejunostomy site was performed, and in 94 cases, a whole layer reinforced suture with absorbible materials was used. We evaluated the incidence of complications according to age, sex, stage of patients, and combined resection. Also, we compared the incidences of complications for seromuscular and whole layer reinforced sutures. Results: The complications are major leaks ($2.9\%$), minor leaks ($3.5\%$), stenosis, bleeding ($1.8\%$), and abscess formation formation ($1.8\%$). In the five cases of major leaks, there were four mortalities with operative methods. The other patients with stenosis, bleeding, and abscess formation were treated conservatively with success. The incidences of complications were not related with age, sex, stages, and combined resection. The incidences of complications for the whole layer reinforced suture group ($2.9\%$) were less than those for the seromuscular reinforced group ($8.8\%$, P=0.04). Conclusion: The most serious complication of esophagojejunal anastomosis is major leakage with an $80\%$ mortality. The other complications are stenosis, bleeding, and abscess formation, for which no mortalities occurred during this study. Whole layer suture of the esophagojejunal anastomotic site is an important method for preventing leakage.

  • PDF

Intracorporeal Anastomosis Using Linear Stapler in Laparoscopic Distal Gastrectomy: Comparison between Gastroduodenostomy and Gastrojejunostomy

  • Lee, Hak-Woo;Kim, Hyoung-Il;An, Ji-Yeong;Cheong, Jae-Ho;Lee, Kang-Young;Hyung, Woo-Jin;Noh, Sung-Hoon
    • Journal of Gastric Cancer
    • /
    • v.11 no.4
    • /
    • pp.212-218
    • /
    • 2011
  • Purpose: Intracorporeal anastomosis during laparoscopic gastrectomy is becoming increasingly prevalent. However, selection of the anastomosis method after laparoscopic distal gastrectomy is equivocal because of a lack of technical feasibility and safety. We compared intracorporeal gastroduodenostomy with gastrojejunostomy using linear staplers to evaluate the technical feasibility and safety of intracorporeal anastomoses as well as its' minimally invasiveness. Materials and Methods: Retrospective analyses of a prospectively collected database for gastric cancer revealed 47 gastric cancer patients who underwent laparoscopic distal gastrectomy with either intracorporeal gastroduodenostomy or gastrojejunostomy from March 2011 to June 2011. Perioperative outcomes such as operation time, postoperative complication, and hospital stay were compared according to the type of anastomosis. Postoperative inflammatory response was also compared between the two groups using white blood cell count and high sensitivity C-reactive protein. Results: Among the 47 patients, 26 patients received gastroduodenostomy, whereas 21 patients received gastrojejunostomy without open conversion or additional mini-laparotomy incision. There was no difference in mean operation time, blood loss, and length of postoperative hospital stays. There was no statistically significant difference in postoperative complication or mortality between two groups. However, significantly more staplers were used for gastroduodenostomy than for gastrojejunostomy (n=6) than for gastroduodenostomy and (n=5). Conclusions: Intracorporeal anastomosis during laparoscopic gastrectomy using linear stapler, either gastroduodenostomy or gastrojejunostomy, shows comparable and acceptable early postoperative outcomes and are safe and feasible. Therefore, surgeons may choose either anastomosis method as long as oncological safety is guaranteed.

Intracorporeal Esophagojejunostomy Using a Circular or a Linear Stapler in Totally Laparoscopic Total Gastrectomy: a Propensity-Matched Analysis

  • Kang, So Hyun;Cho, Yo-Seok;Min, Sa-Hong;Park, Young Suk;Ahn, Sang-Hoon;Park, Do Joong;Kim, Hyung-Ho
    • Journal of Gastric Cancer
    • /
    • v.19 no.2
    • /
    • pp.193-201
    • /
    • 2019
  • Purpose: There is no consensus on the optimal method for intracorporeal esophagojejunostomy (EJ) in laparoscopic total gastrectomy (LTG). This study aims to compare 2 established methods of EJ anastomosis in LTG. Materials and Methods: A total of 314 patients diagnosed with gastric cancer that underwent LTG in the period from January 2013 to October 2016 were enrolled in the study. In 254 patients, the circular stapler with purse-string "Lap-Jack" method was used, and in the other 60 patients the linear stapling method was used for EJ anastomosis. After propensity score matching, 58 were matched 1:1, and retrospective data for patient characteristics, surgical outcome, and post-operative complications was reviewed. Results: The 2 groups showed no significant difference in age, body mass index, or other clinicopathological characteristics. After propensity score matching analysis, the linear group had shorter operating time than the circular group ($200.3{\pm}62.0$ vs. $244.0{\pm}65.5$, $P{\leq}0.001$). Early postoperative complications in the circular and linear groups occurred in 12 (20.7%) and 15 (25.9%, P=0.660) patients, respectively. EJ leakage occurred in 3 (5.2%) patients from each group, with 1 patient from each group needing intervention of Clavien-Dindo grade III or more. Late complications were observed in 3 (5.1%) patients from the linear group only, including 1 EJ anastomosis stricture, but there was no statistical significance. Conclusions: Both circular and linear stapling techniques are feasible and safe in performing intracorporeal EJ anastomosis during LTG. The linear group had shorter operative time, but there was no difference in anastomosis complications.

Feasibility and Potential of Reduced Port Surgery for Total Gastrectomy With Overlap Esophagojejunal Anastomosis Method

  • Ho Seok Seo;Sojung Kim;Kyo Young Song;Han Hong Lee
    • Journal of Gastric Cancer
    • /
    • v.23 no.3
    • /
    • pp.487-498
    • /
    • 2023
  • Purpose: Reduced port surgery (RPS) for gastric cancer has been frequently reported in distal gastrectomies but rarely in total gastrectomies. This study aimed to determine the feasibility of 3-port totally laparoscopic total gastrectomy (TLTG) with overlapping esophagojejunal (EJ) anastomosis. Materials and Methods: A total of 81 patients who underwent curative TLTG for gastric cancer (36 and 45 patients with 3-port and 5-port TLTG, respectively) were evaluated. All 3-port TLTG procedures were performed with the same method as 5-port TLTG, including EJ anastomosis with the intracorporeal overlap method using a linear stapler, except for the number of ports and assistants. Short-term outcomes, including the number of lymph nodes (LNs) harvested by station and postoperative complications, were analyzed retrospectively. Results: Clinical characteristics were not significantly different among the groups, except that the 3-port TLTG group was younger and had a lower rate of pulmonary comorbidity. There were no cases of open conversion or additional port placement. All operative details and the number of harvested LNs did not differ between the groups, but the rate of suprapancreatic LN harvest was higher in the 3-port TLTG group. No significant differences were observed in the overall complication rates between the 2 groups. Conclusions: Three-port TLTG with overlapping EJ anastomoses using a linear stapler is a feasible RPS procedure for total gastrectomy to treat gastric cancer.

Anastomosis Site Stricture after Using Stapler Devices in a Total Gastrectomy (위전절제술에서 자동단단문합기 사용 후 문합부 협착에 대한 고찰)

  • Ku, Do-Hoon;Suh, Byoung-Jo;Han, Won-Sun;Yu, Hang-Jong;Kim, Jin-Pok
    • Journal of Gastric Cancer
    • /
    • v.4 no.4
    • /
    • pp.252-256
    • /
    • 2004
  • Purpose: Anastomosis site stricture is a common complication after a total gastrectomy. End-to-end anastomosis (EEA) stapler devices are preferred to a hand-sewn esophagojejunostomy these days. However, stapling devices have been reported not to reduce the incidence of esophagojejunostomy site stricture considerably. Materials and Methods: From Sep. 1998 to Dec. 2000, at Korea Gastic Cancer Center, Seoul Paik Hospital, Inje University, we experienced 228 total gastrectomies in which EEA stapling devices had been used. We investigated the correlation of the stricture with the size of the EEA stapling device, the type of esophagojejunal reconstruction, reflux esophagitis, and duration of stricture development. Results: Among the 228 cases, as far as the patient's age was concerned, the 7th decade was the most common 64 cases, followed by the 5th decades. The Male-to-female ratio was 2.3:1. A loop esophagojejunostomy was used in 223 cases, and the Roux-en-Y method was used in 5 cases. The 32 patients with anastomosis site stricture were patients with loop esophagojejunal anastomosis. Anastomosis site stricture occurred in $14\%$ (32/228) of the total gastrectomy cases, in$15.9\%$ (11/69) of the total gastrectomies involving stapler devices with a 25-mm diameter, and in $13.2\%$ (21/159) of the total gastrectomies involving staper devices with a 28-mm diameter. There was no correlation between the incidence of stricture and EEA- stapling device size (P>0.05). Reflux esophagitis occurred in 56 of the 228 cases, with 7 of those 56 cases ($12.5\%$) and 25 of the remaining 172 cases ($14.5\%$) having strictures. There was no considerable difference in the stricture incidence rate according to the presence of reflux esophagitis (P>0.05). The onset of stricture development, occurred within 6 months in 16 cases, including 4 cases of reflux esophagitis, between 7 and 18 months in 14 cases, including 3 cases of reflux eshophagitis, and after 19 months in 2 cases. Conclusion: An esophagojejunostomy site stricture after a total gastrectomy was not correlated with the esophagojejunal reconstruction type, the size of the stapling device, or the presence of reflux esophagitis. General anastomosis technical factors (e.g., adequate blood supply, tension-free manner, adequate hemostasis) may be more important to prevent anastomosis site stricture after an esophagojejunostomy during a total gastrectomy.

  • PDF

Surgical Treatment of Postoperative Leakage with Pedicled Omental Flap (유경성 대망이식편을 이용한 술후 식도천공 치험1례)

  • Im, Chang-Yeong;Kim, Yo-Han;Yu, Hoe-Seong
    • Journal of Chest Surgery
    • /
    • v.26 no.4
    • /
    • pp.325-328
    • /
    • 1993
  • The pedicled omental flap has been used for treatment of various kind of complications in thoraxcic surgery. Its property of promoting neovascularization , immunilogic properties that limiting the spread of infection, providing soft tissue coverage are very effective in treatment esophageal fistulas. Also, congenital broncho-esophageal fistula [ BEF ] is a rare disease entity which was reported about 100 cases around the world. We experienced 27 years old female patient with Braimbridge type I congenital BEF. We performed division of BEF using stapler and pericardial patch coverage of esophageal side with concomittent left lower lobectomy. This patient was complicated with postoperative esophageal leakage with empyema thoracis. We have successfully managed these problems with re-thoracotomy and re-closure of esophageal fistula using Right Gastroepiploic Artery based pedicled omental flap wrapping around the esophageal anastomosis site. It is felt that pedicled omental flap is a very effective method to manage esophageal complication such as postoperative esophageal leakage.

  • PDF

Department of Plastic Surgery, College of Medicine, The Catholic University of Korea (두피나 눈썹부의 반흔성형술 시 편리한 모발고정법)

  • Park, Jae Hee;Oh, Kap Sung
    • Archives of Plastic Surgery
    • /
    • v.32 no.5
    • /
    • pp.671-673
    • /
    • 2005
  • Difficulties with intraoperative fixation of hair or eyebrow sometimes occur because of displacement or dislodgment of hair during surgery. So we have found that the simple application of a small transparent adhesive disposable dressing, such as $Tegaderm^{(R)}$ or OpSite $Flexigrid^{(R)}$, can prevent this. One of the advantages of this technique, compared with stapler fixation of the hair, is that it does not cause local trauma. An OpSite $Flexigrid^{(R)}$ or $Tegaderm^{(R)}$ is placed such that it covers both the scar and operation site hair. The hair or eyebrow were easily, quickly, and firmly positioned even on the nonshaved scalp. The technique seems to have no drawbacks, and when the $Tegaderm^{(R)}$ or Opsite $Flexigrid^{(R)}$ is removed, patient experiences little discomfort. We have never seen an allergic or direct traumatic cutaneous response following the use of these materials.

Left Atrium Rupture after Left Pneumonectiomy Using Autostapler -A Case Report- (자동봉합기를 이용한 전폐절제술후 발생한 좌심방 파열)

  • 배기만
    • Journal of Chest Surgery
    • /
    • v.27 no.5
    • /
    • pp.418-421
    • /
    • 1994
  • The usage of autosuture instruments and techniques in resection of bronchovascular structures gained increasing acceptance amongst surgeons in the recent years. The manipulation of these devices are simple, safe, and shortens operating time by avoiding numerous ties and sutures. We have been using autosuture instruments in most of pulmonary resections in Yongdong Severance hospital, and had a satisfactory results. However, we recently have experienced post-pneumonectomy rupture of left pulmonary vein on postoperative one day where the rupture site was in the border of left atrium and left pulmonary vein where the stapler was fired. The patient underwent emergency operation to control massive bleeding and successfully managed by left atrial suture.

  • PDF

Development of Intelligent Robot for Anastomosis of Intestine (대장 소장 원형문합수술을 위한 지능형 로봇개발)

  • Kwun Y.M.;Hong J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.139-143
    • /
    • 2005
  • As increasing gastrointestinal pathologies, general and thoracic surgeries using circular staplers have been dramatically increased. Because of convenience for surgical procedure, recently, various circular staplers for anastomosis have been used widely. Since the circular staplers conventional have used the displacement control method, however, the anastomosis could have various biomechanical conditions. To do that, biomechanical system of gastrointestinal soft tissue should be examined to control the anastomotic condition. In this study, a new intelligent robot used in circular anastomosis. The intelligent robot driven by a stepper motor and controlled by a digital signal processor.

  • PDF

Clinical Usefulness of a Totally Laparoscopic Gastrectomy (전(全)복강경하 위절제술의 임상적 유용성)

  • Kim, Jin-Jo;Kim, Sung-Keun;Jun, Kyong-Hwa;Kang, Han-Chul;Song, Kyo-Young;Chin, Hyung-Min;Kim, Wook;Jeon, Hae-Myung;Park, Cho-Hyun;Park, Seung-Man;Lim, Keun-Woo;Park, Woo-Bae;Kim, Seung-Nam
    • Journal of Gastric Cancer
    • /
    • v.7 no.3
    • /
    • pp.132-138
    • /
    • 2007
  • Purpose: In Korea, the number of laparoscopy-assisted distal gastrectomies for early gastric cancer patients has been on the increase. Although minimally invasive surgery is more beneficial, no reported case of a total laparoscopic gastrectomy has been reported because of difficulty with intracorporeal anastomosis. This study attempts, through our experience, to determine the safety and feasibility of a total laparoscopic gastrectomy with various types of intracorporeal anastomosis using laparoscopic linears stapler in treating early gastric carcinomas. Materials and Methods: We investigated the surgical results and clinicopatholgical characteristics of 81 patients that underwent a totally laparoscopic distal gastrectomy at our department between June 2004 and May 2007. The intracorporeal anastomoses were performed by using laparoscopic linear staplers. Results: The mean operative time was 287 minutes, the mean anastomotic time was 40 minutes, and the mean number of laparoscopic linear staplers used for an operation was 7.5. The mean time to the first flatus, the first food intake, and discharge from hospital was 2.9, 3.6, and 10.3 days respectively. There were 11 cases of postoperative complications, but no case of postoperative mortality or conversion to an open procedure. In 75 patients with an adenocarcinoma, the mean number of lymph nodes harvested was 38.1 and the stage distribution was as follows: stage I, 72 patients; stage II, 2 patients; stage IV, 1 patient. During the mean follow-up period of 14 months, 5 patients died of other causes and there were no cases of cancer recurrence. Conclusion: A total laparoscopic gastrectomy with intracorporeal anastomosis by using a laparoscopic linear stapler was found to be safe and feasible. We were able to obtain acceptable surgical outcomes in terms of minimal invasiveness.

  • PDF