• 제목/요약/키워드: standardized test

검색결과 1,001건 처리시간 0.022초

스테인리스강 입계부식 (Intergranular Corrosion of Stainless Steel)

  • 김홍표;김동진
    • Corrosion Science and Technology
    • /
    • 제17권4호
    • /
    • pp.183-192
    • /
    • 2018
  • 스테인리스강은 오스테니틱 스테인리스강, 페리틱 스테인리스강과 마르텐시틱 스테인리스강으로 대별할 수 있으며, 이 고도의 안전성이 요구되는 산업계에서 스테인리스강의 입계부식, 응력부식균열과 핏팅과 같은 국부적 부식이 발생하면 대형사고로 귀결될 수 있다. 스테인리스강의 입계부식 기구와 대책 그리고 입계부식측정 방법에 대한 기술 소개를 하여 산업현장에서 흔히 접하는 스테인리스강 예민화에 대한 길잡이가 되도록 하고, 이 분야를 전문적으로 연구하려는 연구자에게 예민화 전반을 이해하는데 활용되도록 하였다.

한국어판 감성지능 측정도구의 신뢰도와 타당도 검증 (The Reliability and Validity of Korean Version of Wong and Law Emotional Intelligence Scale (K-WLEIS))

  • 정하림;최희정;박명숙
    • 대한간호학회지
    • /
    • 제50권4호
    • /
    • pp.611-620
    • /
    • 2020
  • Purpose: The aim of this study was to evaluate the reliability and validity of the Korean version of the Wong and Law Emotional Intelligence Scale (K-WLEIS). Methods: Data were collected from 360 nursing students using a self reported questionnaire. Exploratory and confirmatory factor analysis were used to test construct validity. Convergence validity was identified by correlation with communication competency. Item convergent and discriminant validity were also analyzed. Reliability was evaluated internal consistency and test-retest reliability. Results: The results of exploratory factor analysis showed that the eigen values ranged from 1.34 to 5.86 and 73.2% of the total explained variance. Confirmatory factor analysis showed adequate model fit indices (χ2/df 1.89, RMSEA .07, GFI .89, CFI .95, and TLI .93) and standardized factor loadings (.48 to .87). The average extracted variances (.71 to .79) and composite reliability (.80 to .87) validated convergence and discriminant validity of the items. Test-retest reliability of intra-class correlation coefficient was .90 and the Cronbach's alpha coefficient was .88. Conclusion: The K-WLEIS is an appropriate scale for measuring the emotional intelligence of Korean nursing students. Therefore, it is expected that the K-WLEIS will be used for nursing education programs to improve nursing students' emotional intelligence.

경년열화에 따른 송전용 폴리머 현수애자의 표면 및 트래킹 성능 (Surface and Tracking Properties of Polymer Suspension Insulator for Power Transmission with secular variation)

  • 조한구;이운용;한세원;한동회;허종철;최인혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.233-236
    • /
    • 2004
  • Recently, the polymer insulators that are used for high voltage applications have some advantages such as light weight, small size, vandalism resistance, hydrophobicity and easy making process. During outdoor service of polymer insulators, the surface of the insulating material is frequently subjected to moisture and contamination that lead to dry band arcing. Their tracking resistance, erosion resistance, end sealing and shed design are very important because dry band arcing causes degradation of polymer surface. The shape design of porcelain insulator is formalized but design standard for polymer insulator is no standardized up to now, much research is necessary in real condition. In this paper, the surface and tracking properties of polymer suspension insulator for power transmission is investigated with ICP-AES, SEM, EDX, tracking wheel test and flashover voltage test. The diagnosis of insulator sample in tracking test hass been analyzed by leakage current STRI Guide and thermal image.

  • PDF

철도차량용 냉방기 배관계의 진동저감 연구 (Vibration Reduction of Pipe Line in Air-conditioner for Railway Vehicle)

  • 유원희;정용호;구정서
    • 한국소음진동공학회논문집
    • /
    • 제22권10호
    • /
    • pp.925-931
    • /
    • 2012
  • The air-conditioner for railway vehicle should have vibration durability in order to operate normally in vehicle running situation. KS R 9144(vibration test methods for railway vehicle parts) is used to verify the vibration durability. The specifications of compressor, condenser and evaporator for air-conditioner in railway vehicle are standardized, but the shape and structure of pipe lines are not specified. Because the air-conditioner handler produces the pipe line arbitrarily, sometimes the pipe line is broken during the vibration durability test. In this research the cause identification and solution of pipe line breaking problem in during the vibration durability test were studied for air-conditioner of railway vehicle(diesel multiple unit). It was found that the natural frequency of pipe line is related to the pipe line breaking by experiment. A new pipe line shape was introduced by using FEA in order to avoid the resonance. The prototype new pipe line was applied to air-conditioner and the natural frequency was measured by experiment in order to verify the resonance avoidance. The vibration reduction of air-conditioner with new pipe line was reviewed by comparing to the air-conditioner with original one.

관계형데이터를 이용한 그래프 데이터베이스의 모델별 구조 분석과 쿼리 성능 비교 연구 (Structural Analysis and Performance Test of Graph Databases using Relational Data)

  • 배석민;김진형;유재민;양성열;정재진
    • 한국멀티미디어학회논문지
    • /
    • 제22권9호
    • /
    • pp.1036-1045
    • /
    • 2019
  • Relational databases have a notion of normalization, in which the model for storing data is standardized according to the organization's business processes or data operations. However, the graph database is relatively early in this standardization and has a high degree of freedom in modeling. Therefore various models can be created with the same data, depending on the database designers. The essences of the graph database are two aspects. First, the graph database allows accessing relationships between the objects semantically. Second, it makes relationships between entities as important as individual data. Thus increasing the degree of freedom in modeling and providing the modeling developers with a more creative system. This paper introduces different graph models with test data. It compares the query performances by the results of response speeds to the query executions per graph model to find out how the efficiency of each model can be maximized.

초등학교 과학영재학급 학생선발을 위한 과학 창의적 문제해결력 검사도구 개발 (Development of the Scientific Creative Problem Solving Test for the Selection of Gifted Science Students in Elementary School)

  • 최선영;강호감
    • 한국초등과학교육학회지:초등과학교육
    • /
    • 제25권1호
    • /
    • pp.27-38
    • /
    • 2006
  • The purpose of this study was to develop a test of a creative problem solving (CPS) for the selection of gifted science students in elementary school. For this, the methods and procedures of the selection of gifted science students was investigated through the internet homepages 23 gifted science education centers of universities and 16 city. province offices of education. The results of this study were as follows: Most of the gifted science students were selected through a multi-step examination process. They were selected on the basis of their records by recommendation of a principal or a classroom teacher in their school, by operation of standardized tests (ex. intelligence quotient score, achievements in science and mathematics, interest and attitude/aptitude for science as well as through other means), as well as through intensive observation of those gifted science students who are selected by interview and oral tests. The selection of gifted students was not evaluated through creativity testing; giftedness in city. province office of education. Testing of CPS was found to be especially lacking in these organizations. For the development of the test items of CPS in science, the five elements were extracted through the framework for the content analysis of the CPS: problem exploration, problem statement, solution thinking, experiment design, and assesment. In addition, suggestions were made regarding an appropriate scoring system for the test of the CPS. As the result of the developed test was applied to the 4th grade of the gifted and general student, we found that gifted students were superior to general students. In conclusion, it was that the CPS test developed in this study should be used to evaluate the CPS for the selection of gifted students.

  • PDF

Determining Sincerity of Effort Based on Grip Strength Test in Three Wrist Positions

  • Bhuanantanondh, Petcharatana;Nanta, Pirun;Mekhora, Keerin
    • Safety and Health at Work
    • /
    • 제9권1호
    • /
    • pp.59-62
    • /
    • 2018
  • Background: Several grip strength tests are commonly used for detecting sincerity of effort. However, there is still no widely accepted standardized sincerity of effort test. Therefore, this study aimed to examine whether grip strength test in three wrist positions could distinguish between maximal and submaximal efforts. Methods: Twenty healthy individuals (10 men and 10 women) with a mean age of $26.7{\pm}3.92years$ participated in this study. All participants completed two test conditions (maximal and submaximal efforts) in three wrist positions (neutral, flexion, and extension) using both hands. Each participant exerted 100% effort in the maximal effort condition and 50% effort in the submaximal effort condition. The participants performed three repetitions of the grip strength test for each session. Results: The results showed that there is a significant main effect of the type of effort (p < 0.001), wrist position (p < 0.001), and hand (p = 0.028). There were also significant types of effort and wrist position interactions (p < 0.001) and effort and hand interactions (p < 0.028). The results also showed that grip strength was highest at the wrist in neutral position in both the maximal and the submaximal effort condition. Grip strength values of the three wrist positions in the maximal effort condition were noticeably greater than those in the submaximal effort condition. Conclusion: The findings of this study suggest that grip strength test in three wrist positions can differentiate a maximal effort from a submaximal effort. Thus, this test could potentially be used to detect sincerity of effort in clinical setting.

지역적 $x-^{2}$-테스트를 이용한 장면전환검출 기법 (Scene Change Detection Using Local $x-^{2}-Test$)

  • 김영례;이양원
    • 한국컴퓨터정보학회논문지
    • /
    • 제11권3호
    • /
    • pp.193-201
    • /
    • 2006
  • 본 논문에서는 급진적 장면전환부터 점진적 장면전환까지 모두 검출할 수 있는 방법을 제안한다. 이 방법은 지역적 $X^{2}$-테스트로서 기존의 컬러 히스토그램과 $X^{2}$-테스트를 결합한 방법이다. 본 논문을 위하여 기존의 히스토그램 기반 알고리즘과 비교하여 좋은 성능을 보여주는 $X^{2}$-테스트를 변형하였고. 컬러 값의 세분화 작업에 따른 검출효과를 높이기 위하여 명암도 등급에 따른 가중치를 적용한 지역적 $X^{2}$-테스트를 이용하였다. 이 방법은 복잡하고 다양한 시세계의 영상 변화를 가장 일반적이고 표준화된 방법으로 분석하고 분할하며 표현할 수 있는 방법이다. 기존의 $X^{2}$-테스트와 제안된 지역적 $X^{2}$-테스트 방법의 비교는 실험을 통해 입증되었다.

  • PDF

$^{18}F$-FDG를 이용한 전신 PET 검사에서 혈당 측정 검사지의 정확한 사용에 따른 혈당 수치의 차이 분석 (The Analysis of Blood Glucose Level Difference According to the Exact Use of Blood Glucose Measurement Test Strips in $^{18}F$-FDG Wholebody PET)

  • 박순기;이남기;남궁창경;정우영
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.100-103
    • /
    • 2010
  • $^{18}F$-FDG PET 검사는 포도당 대사를 이용하여 전신의 종양을 평가하는 검사로 전처치 과정에서 혈당 측정의 중요성이 매우 높다. 혈당 수치가 높은 상태에서 FDG를 투여하면 FDG와 혈중 포도당이 세포 내 흡수에 서로 경쟁하게 되고 종양으로의 FDG 섭취가 감소되어 정확한 검사가 되지 않을 가능성이 있다. 혈당 측정에 사용되는 혈당 측정 검사지는 경우에 따라 모세혈관혈 전용 측정 검사지와 모세혈관혈과 정맥혈을 모두 측정 가능한 범용 측정 검사지로 구분되어 있는데, 정확한 혈당 측정 검사지(스트립)의 사용에 따른 혈당 수치의 차이를 비교 분석 하였다. 연구 대상은 2010년 3월부터 4월까지 서울아산병원 핵의학과에서 $^{18}F$-FDG whole body PET 검사를 시행한 환자 중 46명(남자: 32명, 여자: 14명, 평균연령 $57.3{\pm}12.3$세) 을 연구의 대상으로 하였다. 실험기기는 Abbott사의 Optium Xceed혈당 측정기를 이용하였고, 모세혈관혈과 정맥혈을 모두 측정 가능한 범용 측정 검사지를 사용하여 동일 환자의 모세혈관혈과 정맥혈의 혈당 수치의 차이를 분석하였다. 또한, 모세혈관혈 전용 측정 검사지를 사용하여 동일 환자의 모세혈관혈과 정맥혈의 혈당 수치의 차이를 비교 분석하였다. 분석방법은 MINITAB 통계 프로그램을 이용하여 paired t-test 검정을 시행하였다. 모세혈관혈과 정맥혈을 모두 측정 가능한 범용 측정 검사지로 측정한 동일 환자의 모세혈관혈과 정맥혈의 혈당 수치는 각각$95.2{\pm}12.4$ mg/dL, $104.1{\pm}14.4$ mg/dL (t=8.0, p<0.001)로 통계적으로 유의한 차이가 있었다. 모세혈관혈 전용 측정 검사지로 측정한 동일 환자의 모세혈관혈과 정맥혈의 혈당 수치는 각각 $91.5{\pm}13.6$ mg/dL, $108.1{\pm}16.2$ mg/dL (t=9.2, p<0.001)로 통계적으로 유의한 차이가 있었다. 선행연구에 의하면 모세혈관혈과 정맥혈의 혈당 수치는 여러 가지 이유로 인해 차이가 있는 것으로 보고 되었고 본 연구의 결과도 유사한 차이를 확인하였다. $^{18}F$-FDG PET 검사 전에 혈당 수치를 측정할 때 모세혈관혈 전용 측정 검사지로 정맥혈의 혈당을 측정하는 것은 부정확한 혈당 수치를 측정할 수 있으므로 주의해야 할 것이다. 그러므로 적합한 측정 검사지와 규정된 측정절차를 이행하는 것이 측정 편차를 줄일 수 있어 PET 검사의 전처치를 보다 명확하게 확인할 수 있을 것이다. 또한, 혈당 측정 시에 혈액 채취 부위를 모세혈관 또는 정맥혈관 중에서 항상 동일한 부위에서 측정하는 등의 표준화 과정이 필요할 것이다.

  • PDF

CEA 키트들 간의 성능 평가에 대한 고찰 (A Study on Performance Evaluation of CEA kits)

  • 하동혁;신희정;유태민;노경운
    • 핵의학기술
    • /
    • 제22권1호
    • /
    • pp.76-79
    • /
    • 2018
  • Purpose Carcinoembryonic antigen (CEA) is cell-surface 180-200 kDa glycoprotein that is overexpressed in breast, stomach pancreas, lung, and colorectal cancers. CEA was first described in 1965 by Gold and Freedman and then serum CEA of colorectal cancer patients was first measured in 1969 by radioimmunoassay by Thomson. CEA is currently most widely used tumor marker in the clinic for management of colorectal cancer. Various CEA test kits have been developed and commercialized. CEA kits from different manufacturers might have different test results because of different reagents and protocol. The purpose of this study was to compare results of four commercial available CEA kits. Materials and Methods This study was designed to evaluate four commercially available CEA kits using serum samples acquired from 120 patients who visited our clinic. Test results were compared and analyzed according to the respective test methods. High concentration samples were diluted with saline and diluted solution. Results All of the four kits showed a significant correlation within the reference value. However, three of the four kits used for the dilution test using high concentration samples showed the hook effect. Conclusion Results of the present study showed that It is important to establish the standardized dilution standards for the high-concentration specimens to manage the error of the test result by the hook effect.