• 제목/요약/키워드: standard testing method

검색결과 578건 처리시간 0.023초

결정형 산화규소의 표준시료 확보방안에 대한 연구 (A Study on Developing Reliable Standard Samples of Crystalline Silica)

  • 황은송;이은지;박해동
    • 한국산업보건학회지
    • /
    • 제34권3호
    • /
    • pp.247-253
    • /
    • 2024
  • Objectives: The purpose of this study is to establish a method for the production of standard samples of crystalline silica and to assess its feasibility for the future application in non-mandatory quality control. Methods: We dispersed crystalline silica in 2-propanol to prepare a 1 mg/mL dispersion solution. Between 50-200 uL of the dispersion solution was taken with a pipette, injected onto PVC filters, air-dried, and used as samples. The variation and homogeneity of the quartz concentrations were confirmed by FTIR analysis. Analytical proficiency testing was conducted across 30 voluntary participants. Results: The coefficient of variation was lower for samples prepared using supernatant (settled for 16 hours) compared to those made with dispersion solution. The contamination level after using the pipette tip one to five times was 8.13-9.89% of the solution's concentration. Homogeneity was confirmed within the concentration of 0.0223-0.0431 mg/mL, but it was not at the higher concentration of 0.0553 mg/mL. In the analytical proficiency testing, the coefficient of variation for each level ranged from 24.6% to 28.3%, with a compliance rate of 90.0% to 96.7%. Conclusions: This study was conducted to produce standard samples of crystalline silica. The homogeneity of the samples was confirmed at low concentrations. However, further investigations on the applicability of wider range of concentrations are needed.

동상민감성 판정 실내실험법 및 기준에 대한 고찰 (Review of Frost-susceptibility Testing Methods and Criteria)

  • 이장근;진현우;유병현
    • 한국지반공학회논문집
    • /
    • 제39권7호
    • /
    • pp.39-48
    • /
    • 2023
  • 동상으로 인한 구조물의 피해를 방지하고자 세계 100여개의 국가에서는 토양의 동상민감성을 판정하는 실내실험법에 대해 연구를 진행하였다. 미국과 일본은 알래스카와 홋카이도와 같은 동토지역을 포함하고 있어 동상에 대한 연구가 활발히 진행되었으며, 연구 결과와 현장 적용을 통해 동상민감성 판정 표준 실험법과 기준을 제시하고 있다. 그러나 실험 방법이 복잡하고 공학적인 해설이 부족하며, 결과 분석에 대한 논리가 모호한 부분이 여전히 존재하고 있다. 본 논문에서는 이러한 미국 ASTM(American Society for Testing and Materials)과 일본 JGS(Japanese Geotechnical Society)의 동상 실험법을 동상 실험에 미치는 온도조건, 시료크기, 동결방향, 배수조건 등을 고려하여 면밀히 비교 분석하고, 지금까지 연구결과를 종합하여 향후 국제적인 연구동향에 부합하는 국내 동상민감성 판정 실험법과 기준의 방향을 제시하고자 한다.

비정상면열원법을 이용한 지반물질의 열전달 특성 평가 (Thermal measurement of Geomaterials using Transient Plane Source)

  • 김영진;윤태섭
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회 2차
    • /
    • pp.45-52
    • /
    • 2010
  • Thermal properties of geomaterial are overlooked with other geomechanical properties. The transient line-source (TLS) method is one of the most used testing methods for measuring the thermal conductivity (K) and thermal diffusivity ($\alpha$) of materials. But more recently, Transient Plane-Source method was developed to measure these. It has several advantage of comparing with TSL method, but there has not been documented application in geomaterial. A Resistance Temperature Detector is used to construct sensor. For durability of Probe, Adopt a new technique that two probes are bonded in exact matching. For standard materials, such as glycerin, and ice the measured K and a values of these materials were generally within 2-5% from the standard values in the literature. This document present to evaluate the thermal properties of geomaterials and its application was tested for varying degree of saturation using the Transient Plane Source method. The result of this study suggests that it is an comparatively accurate method for simultaneously measuring thermal conductivity and thermal diffusivity and can identify the feasibility to geomaterial.

  • PDF

Ultra-sensitive HBsAg IRMA 키트의 민감도 및 변이형 검출능 평가 (The Assessment of Ultrasensitive HBsAg kit's Sensitivity level and Performance in Detection of Mutant Forms)

  • 하동혁;민경선;노경운;김현주
    • 핵의학기술
    • /
    • 제15권1호
    • /
    • pp.121-125
    • /
    • 2011
  • 배경 : B형간염표면항원(HBsAg)은 B형간염의 진단에 있어 가장 중요한 혈청학적 지표 중 하나이다. HBsAg 검사에 대한임상검사실의 수요에 맞추어 자동화 장비 및 검사법이 계속 개발되어 왔다. 본 연구는 국내에 보급된 RIAKEY, BNIBT, RIAKEY Ultra Sensitive HBsAg, ROCHE 키트의 민감도 및 변이형 검출능과 CLIA법의 CENTAUR 장비와 RIAKEY Ultra Sensitive HBsAg의 상관계수를 알아보고자 하였다. 방법 : WHO $1^{st}$ International Standard 1985(80/549), WHO $2^{nd}$ International Standard 2003 (00/588) 표준물질 2개를 이용하여 농도별 0.08, 0.04, 0.02, 0.01, 0.005 IU/ml 까지 계단희석을 시행하였으며, Subtype ad 9종, Subtype ay 변이시료 1종을 이용하여 RIAKEY, BNIBT, RIAKEY Ultra Sensitive HBsAg, ROCHE 키트를 이용하여 시행하였다. 그리고, 아형 검출에 사용된 변이시료 10종에 대한 IRMA법의 RIAKEY Ultra Sensitive HBsAg와 CLIA법의 CENTAUR 장비를 이용한 상관계수를 비교하였다. 결과 : 표준물질의 농도별 측정 시 WHO 0.01 PANEL 에서 Index 1.0 이상의 결과 값을 얻었으며, 그 결과 민감도는 0.01 IU/ml로 측정되었다. RIAKEY Ultra sensitve HBsAg 키트가 민감도측면에서 우수함을 알 수 있었다. RIAKEY Ultra sensitve HBsAg IRMA 키트에서는 adw2 9종과 ayw1 1종의 변이형 형태에 따라 모두 Index 1.0 이상으로 혈청중의 HBsAg을 100% 측정할수 있었다. RIAKEY Ultra sensitive HBsAg와 CLIA의 결과가 Y=1.0075 X + 1.2434, $R^2$=0.9982으로 우수한 상관성을 보였다. 결론 : 4세대인 IRMA법의 Ultra Sensitive HBsAg 키트로 혈청중의 HBsAg과 여러 가지 아형을 신속하고 정확히 측정하여 질병을 진단 할 수 있을 것으로 여겨진다.

  • PDF

수질분야 총유기탄소 분석방법에 따른 장비별 특성 비교 (Comparison of Instrument Characteristics on the Total Organic Carbon Analysis Method in Water Samples)

  • 김혜성;황은태;이찬근;조영철
    • 환경영향평가
    • /
    • 제32권5호
    • /
    • pp.353-362
    • /
    • 2023
  • TOC는 수중에 있는 유기물질의 90% 이상을 측정할 수 있으며 신속하고 용이하게 측정할 수 있기 때문에 기존에 사용된 유기오염물질의 지표인 BOD와 COD를 대체하고 있다. 수질오염공정시험기준에 따라 TOC를 측정할 때, 시료의 총탄소 중 무기탄소 비율이 50% 이상일 경우 NPOC법으로 분석하고, 휘발성유기화합물이 수 mg/L 이상일 경우 가감(TC-IC)법으로 분석하도록 규정되어 있다. 이러한 분석조건의 제한성을 검증하기 위해 정제수에 총유기탄소와 무기성 탄소의 비율이 다르게 하여 시험용액에서 총유기 탄소 농도결과를 확인하였는데 가감법과 NPOC법에서 큰 차이가 나타나지 않았다. 휘발성유기화합물 표준 용액을 첨가한 시료를 측정한 결과, NPOC법으로 분석할 때에 퍼징으로 인해 유실되는 탄소량은 크지 않은 것으로 나타나 시료에 휘발성유기화합물이 존재 시 분석방법에 따른 차이는 크지 않은 것으로 판단된다. 수질오염공정시험기준과 환경측정기기의 형식승인·정도검사 등에 관한 고시의 기준에 의한 판정 결과가 달라지는 경우를 판단하기 위해 국내에서 널리 사용하고 있는 2종류의 총유기탄소분석기의 현장시료 농도값 차를 비교한 결과, 제조사에 따라 NPOC법과 가감법에서 0.02~0.83 mg/L 차이가 있었으며, 이에 따라 기기 선정시 주의가 필요할 것으로 판단되었다.

상수도관내 중금속 용출에 대한 수소이온농도의 영향 평가 연구 (Influences of pH on Heavy Metal Leaching in Water Supply Pipelines)

  • 이정원;노유래;박준홍
    • 대한토목학회논문집
    • /
    • 제37권1호
    • /
    • pp.73-82
    • /
    • 2017
  • 우리나라 상수도 기반시설 설비에 관련된 기존의 인증평가는 경제적 측면과 내구성 등 물리적 측면에 초점을 맞추어 사용되어 왔다. 그러나 경제수준이 상승하면서 상수도에 대한 위생, 보건, 안전성, 삶의 질에 대한 국민의식이 향상됨에 따라 상수도 서비스의 위생보건학적 품질향상이 요구되고 있다. 지난 5년간 국내 497개 정수장의 수질분석 자료를 고찰한 결과 pH는 5.8~8.5의 범위로 나타났다. 하지만, 현재 우리나라 수도용 자재 및 제품의 위생안전기준 공정시험방법(위생안전시험법)은 pH 7.0에서만 평가하고 있어, 실제 상수도 pH 조건에서 관내 중금속용출에 대한 기초정보가 부족하다. 이러한 배경으로 본 연구에서는 국내에서 대표적으로 사용되는 관에 대하여 pH변화가 중금속용출에 미치는 영향을 실험적으로 분석연구하였다. 본 연구 결과, pH가 낮아질수록 일부 금속의 용출정도가 증가하는 것을 확인하였다. 특히 pH 5.8일 경우, 구리재질의 관에서 Cu가 보정계수(Normalization Factor) 적용 후에도 위생안전기준을 상회하였다. 스테인레스 재질의 관에서는 Cr, Cu가, 구리재질의 이음관에서는 Cd, Pb, Cu, Zn이, 아연재질의 이음관에서는 Zn이 기준치를 각각 상회하였으나 보정계수를 적용하면 기준치를 만족하였다. 본 연구의 결과로 현행 위생안전시험법에서 pH조건을 7.0 이외의 낮은 pH 조건을 포함하는 개정의 필요성이 제안되었다. 추후 상수도관으로 사용되는 다른 종류의 관에 대한 추가 연구의 필요성도 제시되었다. 본 연구는 차후 우리나라 위생안전기준의 개정연구에 필요한 기초자료 제시에 기여를 하였다.

Modified electrical conductivity test method for evaluation concrete permeability

  • Pilvar, Amirreza;Ramezanianpour, Ali Akbar;Rajaie, Hosein
    • Computers and Concrete
    • /
    • 제16권6호
    • /
    • pp.865-880
    • /
    • 2015
  • Standard test method for bulk electrical conductivity (ASTM C1760) provides a rapid indication of the concrete's resistance to the penetration of chloride ions by diffusion. In this paper a new approach for assessing the bulk electrical conductivity of saturated specimens of hardened concrete is presented. The test involves saturating concrete specimens with a 5 M NaCl solution before measuring the conductivity of the samples. By saturating specimens with a highly conductive solution, they showed virtually the same pore solution conductivity. Different concrete samples yield different conductivity primarily due to differences in their pore structure. The feasibility of the method has been demonstrated by testing different concrete mixtures consisting ordinary and blended cement of silica fume (SF) and calcined perlite powder (CPP). Two standard test methods of RCPT (ASTM C1202) and Bulk Conductivity (ASTM C1760) were also applied to all of the samples. The results show that for concretes containing SF and CPP, the proposed method is less sensitive towards the variations in the pore solution conductivity in comparison with RCPT and Bulk Conductivity tests. It seems that this method is suitable for the assessment of the performance and durability of different concretes containing supplementary cementitious materials.

Characterizing the ac-dc-ac Degradation of Aircraft and Vehicle Organic Coatings using Embedded Electrodes

  • Bierwagen, Gordon P.;Allahar, Kerry N.;Su, Quan;Victoria, Johnston-Gelling
    • Corrosion Science and Technology
    • /
    • 제6권5호
    • /
    • pp.261-268
    • /
    • 2007
  • Embedded sensors were used as an in-situcorrosion-sensing device for aircraft and vehicular structures protected by organic coatings. Results are presented changes associated with a standard Airforce aircraft coating and a standard Army vehicle coating were monitored by embedded sensors. These coatings consisted of a polyurethane topcoat and an epoxy primer, however are formulated to provide different characteristics. The ac-dc-ac testing method was used to accelerate the degradation of these coatings while being immersed in a NaCl medium. Electrochemical impedance spectroscopy and electrochemical noise measurement experiments were used to monitor the induced changes. A comparison of the results between coatings subjected to the ac-dc-ac exposure and coatings subjected to only constant immersion in the NaCl medium is presented. The results were used to demonstrate the effectiveness of the ac-dc-ac method at accelerating the degradation of an organic coating without observably changing the normal mechanism of degradation. The data highlights the different features of the coating systems and tracks them while the coating is being degraded. The aircraft coating was characterized by a high-resistant topcoat that can mask corrosion/primer degradation at the primer/substrate interface whereas the vehicle coating was characterized by a low-resistant topcoat with an effective corrosion inhibiting primer. Details of the ac-dc-ac degradation were evaluated by using an equivalent circuit to help interpret the electrochemical impedance data.

수산나프로닐 캡슐 및 염산트라마돌 캡슐의 용출시험에 관한 연구 (Development of the Dissolution Tests for Nafronyl Oxalate Capsules and Tramadol Hydrochloride Capsules)

  • 황정분;문현주;고서연;장기욱;이규하;손경희;김인규;조대현
    • 약학회지
    • /
    • 제55권5호
    • /
    • pp.411-418
    • /
    • 2011
  • The dissolution test method and an analytical procedure by HPLC were developed and validated for nafronyl oxalate capsules and tramadol hydrochloride capsules. These drugs were not yet characterized by the dissolution specifications in the Korean Pharmaceutical Codex. So, with each reference and test drugs, we did the preliminary and standard experiments based on the Korean Pharmacopeia Guideline of dissolution testing for solid oral dosage forms. The dissolution test for nafronyl oxalate capsules was carried out under sink conditions as follows: dissolution medium phosphate buffer pH 6.8, paddle rotation speed 100 rpm and vessel volume 900 ml. More than 80% of its label amount was released within 30 min in this method. Also the dissolution test for tramadol hydrochloride capsules was carried out under sink conditions as follows: dissolution medium water, paddle rotation speed 50 rpm and vessel volume 900 ml. More than 90% of its label amount was released within 15 min in this method. The dissolution samples were analyzed with a validated HPLC analytical procedure. The analytical methodology showed acceptable values in terms of specificity, linearity, precision and accuracy. The dissolution test methods described above were adequate for the purpose and may be proposed as a pharmacopeial standard to assess the performance of nafronyl oxalate capsules and tramadol hydrochloride capsules. Furthermore, the outcomes of this study were expected to help create an environment where safe and high quality drugs would be distributed on the domestic market making contributions to advancing public health.

무창 기공형 태양열 공기 난방 모듈 성능 모니터링 연구 (Performance Monitoring Study of Unglazed Transpired Solar Air Heating Module)

  • 강은철;현명택;이의준
    • 한국태양에너지학회 논문집
    • /
    • 제22권1호
    • /
    • pp.67-72
    • /
    • 2002
  • Solar Air Systems (SAS) have unique advantages for space heating and tempering ventilation air. Air, unlike water, needs no protection against freezing nor are leaks damaging to the building structure or its contents. In contrast to glazed collector, unglazed steel solar collector may have higher efficiencies over glazed flat collector due to the absence of the glass. Therefore, the monitoring of SAS is so important to evaluate actual performance of SAS for right applications. This study is to provide a testing method with a movable test cell developed in KIER to evaluate the thermal performance of SAS based on international standard method ASHRAE 93-86, "Method of Testing to Determine the Thermal Performance of Solar Collectors". The monitoring tool used advanced technique LabVIEW 6i with portable notebook computer. Sample results have been obtained to access the performance of a reference and a target SAS module. The process and tool introduced here could be used to provide a performance verification data for future implementation study applications.