• 제목/요약/키워드: standard of facility

검색결과 930건 처리시간 0.027초

Quality Management (QM) Standard Issues in FM - Based on Guidance on quality in European FM Standard

  • Lee, So Young;Jang, Yon Hwa;Lee, Myoung Sik
    • Architectural research
    • /
    • 제18권1호
    • /
    • pp.21-29
    • /
    • 2016
  • Importance of FM has rapidly increased because of its growing business. However, due to lack of clarity and identity of FM in professional areas, standardization of FM became to be imperative in such a rapidly changing global business environment. Facility services are defined as the provision of support the primary activities of an organization, delivered by an internal or external provider. Majority of FM activities are services related to 'space and infrastructure' and 'people and organization' (CEN, 2011). The purpose of this study is to investigate definitions and characteristics of FM from both globally and domestic environment, by comparison with international or national standards, to identify quality management in FM and service characteristics of FM, to investigate the differences in service level elaboration in FM, and to suggest standard issues of quality management in FM service quality. This study examines contents of the European Standards in FM, Part 3 'Guidance on quality in Facility Management, especially for the process of QM standardized by CEN (2011) and explores undefined issues such as service level, measurement metrics according to service characteristics of FM. The European FM Standard guides the common process of QM in terms of requirements specification, service level elaboration, measurement metrics development although it does not specifically address various service levels, specific performance metrics and indicators.

노인요양시설 요양층의 기능별 면적구성과 상관요인에 관한 연구 (A Study on the Functional Area Composition and Correlation Factors of Elderly Care Floor in Nursing Home)

  • 윤소희;김석태
    • 한국실내디자인학회논문집
    • /
    • 제24권3호
    • /
    • pp.156-164
    • /
    • 2015
  • Nursing Homes do not have a defined standard in the space area nor does it have a detailed standard facility requirement by law. This can possibly lead to the deterioration of the facility and the system. This directly affects the medical treatment space area within the nursing home. The medical treatment area provides medical treatment to seniors and this is where the seniors get most of their daily services. Therefore, this is research is about the study of the space area of the medical center and the ratio trend of the space area for the medical treatment facility located in senior nursing homes. Ten facilities have been selected in this study to analyze the correlation factors between space area and its trends. The analysis performed includes the conditions relating to the area and what affects the center. We have followed up with a proposal for improvement of the facility and area configuration for the medical treatment facility. Based on the analysis, the following conclusion can be made: First, the senior welfare centers are mostly used as a residence purpose followed a temporary stay of residence facility for the seniors. Second, research indicates that the bigger the facility, nursing and public functions took a larger portion of the space area compared to other services within the senior welfare centers. Third, the study shows the management space area took up about 1%~6% of the entire medical center within the nursing home which is a narrow space area because of the integrated management. Fourth, analysis based on the trend in the time-series indicate after the adoption of the system, there is a continued decline in the space area of nursing, management and public areas. Lastly, since before and after 2008, the space area composition of the nursing facility shows a continuous decline in our study. We can safely conclude that the revised senior welfare act's construction plan has an effect in the facility and is effectively working to meet its requirement. Therefore, the revision of the law is required to reflect the social needs of the residents.

읍.면 지역 최저주거기준 방향 설정 및 기준안 제시 (Proposal of Minimum Housing Standard for Eup-Myun Area)

  • 윤희정
    • 농촌계획
    • /
    • 제17권2호
    • /
    • pp.13-21
    • /
    • 2011
  • The federal government has been implemented several housing policies attempting to improve living quality at Eup-Myun area(rural area), but those were mostly fund supports to reconstruct or repair houses. Existing minimum housing standard is focused on urban apartments and indoor space, but the houses of Eup-Myun area are scattered and are different from urban's house space. Therefore, this study focused on these area, and intended to propose suitable minimum housing standard for Eup-Myun area. Based on literature reviews about housing standard of England, U.S., Japan and South Korea, questionnaire survey was given to 50 experts divided into 2 groups, professors of architecture and researchers on rural environment. This study proposed the direction of new minimum housing standard of Eup-Myun area, it could be added to 2 household composition, be divided into 2 groups, agricultural and non-agricultural residents into facility guideline, be added to outdoor facilities, for example warehouse and open yard, and finally be inserted water quality into environment standard. The results of this study provide insightful strategies for rural housing standard.

건축물에 시설되는 수변전설비 내진설계 및 검사 방법에 관한 연구 (The inspection and seismic design method of electrical facility instated in the building)

  • 김기현;이상익;강민희;배석명
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.332-335
    • /
    • 2009
  • Incase of not considered seismic design at transformer vault which is made of many informant electrical facility, facility is damaged, electrical fire breaks out and second damage is able to break out at generating earthquake. But seismic design yet is not applied to at transformer vault in the country. Regard to seismic design method of electrical facility installed in the building internal, we present the seismic design of electrical facility using "Building construction design standard" in internal and "Manual of seismic design and construction for Building Electrical facility" in japan. This paper will be used detail seismic design of pipe and facility. reliability inspection plan for seismic design and construction of electrical facility

  • PDF

수위계 표준교정장치 최적 설계 (Optimal Design for Standard Calibration Facility of Water-Level Gauges)

  • 신강욱;홍성택;이동근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 D
    • /
    • pp.2492-2494
    • /
    • 2005
  • This study designed on the standard calibration facility for calibration about radar type, ultra-sonic type and floating type. We reviewed calibration facilities, analysis any problems, and proposed optimal plan which uses EDM and electrical level meter.

  • PDF

노인주거 복지시설 안전사고 실태조사에 의한 시설기준 제안에 관한 연구 (A Study on Proposal of Facility Standard by Research of Safety Accidents at Elderly Housing Welfare Facility)

  • 유종옥;박재승
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제17권2호
    • /
    • pp.7-16
    • /
    • 2011
  • The death toll of the elderly by accidents in 2007 takes 6.5% of total death toll. The lost income from this is estimated to be 17 trillion and 511 billion won. According to CISS of Korea Consumer Protection Board, the number of safety related accidents of the elderly at home in 2006 was 486 cases in 2006 and has gradually increased every year. This thesis created 115 guidelines at 14 spaces as facility evaluation index evaluating the aging friendliness of the facility and safety related accidents generated at elderly resident welfare facility, examined influence variables of safety related accidents with 191 elderly including demographic variable, physical skill variable, social psychological variable and facility environmental variables, and then verified relevance between safety accidents and each influence variable. As a result, it was verified through ANOVA test of SAS Package Program and $x^2$- test that facility environmental variable would be closely related to the accident. In this regard, this study newly proposes the facility standards of aging friendly facility by supplementing them with contents and guidelines of facility evaluation table as ways to reduce safety related facility of the elderly.

서귀포 크루즈터미널 CIQ시설 규모산정에 관한 연구 (A Study on the Size Computation of Seogwipo Cruise Terminal CIQ Facilities)

  • 박정근
    • 한국농촌건축학회논문집
    • /
    • 제17권3호
    • /
    • pp.27-36
    • /
    • 2015
  • This research studies the adequate size standard of Seogwipo cruise terminal CIQ facility that is scheduled to be built around Gangjeong harbor area in Seogwipo-city. In order to respond to the highly increasing number of passenger cruise ships compared to Seogwipo cruise terminal design in 2010, the adequate size standard of Seogwipo cruise terminal CIQ facility was examined for passenger service level grade. Based on size computation elements such as the number of passengers of cruise ships with the largest size of port entry, ship landing rate, passenger processing ratio, and surge factor, the CIQ facility size for each service level grade was reviewed. As a result, the area of 2,971m2 (A grade), 2,409 m2 (B grade), and 2,088 m2 (C grade) were computed. This showed that the area of B grade was about 82% and C grade 70% compared to the area of A grade. The CIQ facility size computed for each service level grade in this research was analyzed that its area needed to be increased by 322% at least and 458% at most, compared to the CIQ facility area of 649m2 of the existing design (2010). In order to respond to the increasing number of cruise passengers, provide high-level passenger service, and improve the international image of Jeju, Seogwipo cruise terminal should secure the size that is equal to or higher than the B grade of service level.

폐교 활용을 위한 대구지역 폐교의 배치유형 분석에 관한 기초 연구 - 교육과정 변화를 중심으로 - (Basic Study on the Arrangement Type Analysis of Closed School Facility According in Daegu Area -Focused on the Curriculum Changes-)

  • 김재영;이종국
    • 교육녹색환경연구
    • /
    • 제12권2호
    • /
    • pp.11-18
    • /
    • 2013
  • Since the Standard Design Guide in 1962 and "School Facility Facility Standard Regulation" established in 1969, the elementary school facility in Korea has been amended and complemented. The modern pilot school was started in 1991 and every elementary school facility has been designed based on the modern elementary school from 1994. At present, 8 out of 28 closed schools occurred in the downtown area in Daegu. One of them is located in rent and 7 are used by themselves. The rest 20 schools are located in Dalsung-gun and most of them have old buildings of straight plane shapes built in 1940s. The purpose of this basic study is to pursue the changing process of closed schools based on policy changes of curriculum and to seek the qualitative change when using closed schools. In addition, it is to prepare the using measures when the school close is occurred in the downtown area in the future by classifying and analyzing plane types according to their types.

1916년 <조선총독부건축표준>의 제정 배경과 계획적 적용 (The Context of Enactment and the Application to the Design of in 1916)

  • 주상훈
    • 건축역사연구
    • /
    • 제28권6호
    • /
    • pp.67-76
    • /
    • 2019
  • The purpose of this study is to identify the context of enactment and the application to the design of in 1916. The characteristics of the composition are as follows; First, One-third are general rules of common application, Second, regulations related to cold resistance are set up separately, last, each of the 21 articles was equally divided for schools, hospitals and prisons. The standard reflect the times of the mid-1910s. The Trend of using of the Western Building System in the 1910s, The need for building construction against cold weather, and Actual conditions of renovation, extension and new plans by facility. Furthermore, the fact that various regulations concerning standard design were enacted and used in various Japanese institutions around the 1910s may have influenced the establishment of the standard. Meanwhile, after checking the status of the reflection of the standard on the planning drawings of the government facilities around 1916, it was also found that the plan was carried out in compliance with the provisions of the standard, and that the items already applied before the enactment had been organized into architectural standards.

BF 인증을 위한 경사로 설치기준 개선에 대한 연구 (A Study on Improvement of Ramp Installation Standard for BF Certification)

  • 신동홍
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제26권2호
    • /
    • pp.31-38
    • /
    • 2020
  • Purpose: The ramp is an important facility for the barrier free access and vertical circulation of users of various buildings, including users of walker, wheelchair users, stroller users, and baggage carriers. The installation standards for ramps in Korea have various problems during construction and BF certification. It is necessary to improve the criteria for ensuring practical mobility and safety. Method: Korean standard, International Standard(ISO 21542, 2011), German Standard(DIN 18040-1, 2010), Austrian Standard(OENORM B 1600, 2017), Swiss Standard(Norm SIA 500, 2009), Canadian Standard(Building Standards Guide, 2017), American Standard(ADA Standards, 2010) were investigated and analyzed. A comprehensive improvement of the ramp installation standards is proposed. Results: The ramp is a necessary facility for the barrier free access and vertical circulation of the disabled. It shall be installed with comprehensive consideration of the appropriate slope of the ramp, the distance of the continuous slope, the handle and upstand for pedestrian safety. In order to improve convenience, setting the proper slope and limiting the length of the slope are very important, and improvements are required to the levels presented by international and foreign standards. The unclear standards of Korean law and BF certification standards should be clearly improved so as not to be misinterpreted in construction and Barrier Free Certification. Implication: International and foreign standards should be reviewed to ensure practical mobility and safety. And comprehensive improvement measures should be presented through continuous research.