• Title/Summary/Keyword: standard median

Search Result 460, Processing Time 0.031 seconds

Denoising Algorithm using Wavelet and Element Deviation-based Median Filter (웨이브렛과 원소 편차 기반의 중간값 필터를 이용한 잡음제거 알고리즘)

  • Bae, Sang-Bum;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.12
    • /
    • pp.2798-2804
    • /
    • 2010
  • The audio and image signal are corrupted by various noises in signal processing, many studies are being accomplished to restore those signals. In this paper, the algorithm is proposed to remove additive Gaussian noise and impulse noise at one dimension signal like an speech signal. The algorithm is composed to remove Gaussian noise after removing impulse noise. And the method using wavelet coefficient accumulation is used to remove the Gaussian noise, and the median filter based on element deviation is applied to remove the impulse noise. Also we compare existing methods using SNR(signal-to-noise ratio) as the standard of judgement of improvemental effect.

Reliability testing of InGaAs Waveguide Photodiodes for 40-Gbps Optical Receiver Applications (40-Gbps급 InGaAs 도파로형 포토다이오드의 신뢰성 실험)

  • Joo, Han-Sung;Ko, Young-Don;Yun, Il-Gu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.13-16
    • /
    • 2004
  • The reliability of 1.550m-wavelength InGaAs mesa waveguide photodiodes(WGPDs), which developed for 40-Gbps optical receiver applications, fabricated by metal organic chemical vapor deposition is investigated. Reliability is examined by both high-temperature storage tests and the accelerated life tests by monitoring dark current and breakdown voltage. The median device lifetime and the activation energy of the degradation mechanism are computed for WGPD test structures. From the accelerated life test results, the activation energy of the degradation mechanism and median lifetime of these devices in room temperature are extracted from the log-normal failure model by using average lifetime and the standard deviation of that lifetime in each test temperature. It is found that the WGPD structure yields devices with the median lifetime of much longer than $10^6$ h at practical use conditions. Consequently, this WGPD structure has sufficient characteristics for practical 40-Gbps optical receiver modules.

  • PDF

Interlace to Progressive Conversion Method Using the Pseudomedian Filters (Pseudomedian필터를 이용한 주사선 보간기법)

  • 권병헌;장광수;황병원
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.10
    • /
    • pp.1900-1909
    • /
    • 1994
  • Although the existing NTSC TV standard is highly sophisticated, it has some inherent problems. One of these problems is interlaced scanning, which yields a poor result in terms of the vertical picture resolution. In this paper, we have proposed the interlace to progressive conversion method using the pseudomedian filters. Since the proposed method is processed in the intra field is different from the conventional method using the median filter, it is implemented without using field memory and its performance is same or nearly the same as the corresponding performance of the median filtering method. The performance of the proposed method has been compared with that of conventional methods through computer simulation.

  • PDF

Empirical Fragility Curves for Bridge (교량의 경험적 손상도 곡선)

  • Lee, Jong-Heon;Kim, Woon-Hak;Choi, Jung-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.1
    • /
    • pp.255-262
    • /
    • 2002
  • This paper presents a statistical analysis of empirical fragility curves for bridge. The empirical fragility curves are developed utilizing bridge damage data obtained from the 1995 Hyogoken Nanbu(Kobe) earthquake. Two-parameter lognormal distribution functions are used to represent the fragility curves with the parameters estimated by the maximum likelihood method. This paper also presents methods of testing the goodness of fit of the fragility curves and estimating the confidence intervals of the two parameters(median and log-standard deviation) of the distribution. An analytical interpretation of randomness and uncertainty associated with the median is provided.

Emergency Repair Using Cervico-median Sternotomy for Cervicothoracic Penetrating Injury (경흉부 관통상에 대한 경부와 정중흉골절개술을 이용한 치험 1례)

  • Lee, Hyun Joo;Kim, Hyun Koo;Choi, Young Ho
    • Journal of Trauma and Injury
    • /
    • v.21 no.2
    • /
    • pp.136-139
    • /
    • 2008
  • A great variety of penetrating injuries is happening due to the increasing population and violence today. An optimal surgical approach is the key factor for successful repair of a complicated penetrating injury. A 23-year-old woman fell down the stairs from the second floor and received cervico-thoracic penetration injury due to a metalic bar. The metalic bar ruptured the right jugular vein and penetrated the left upper and lower lung. Under cervico-median sternotomy, neck vessels were repaired and the left thorax was successfully entered to repair the damaged lung through the mediastinal pleura. With this approach, the patient's position did not need to be changed during operation, while reduced the operation time compared to the conventional approach (cervical incision and standard thoracotomy).

A Study on the Suggestions for Standard Flow Conditions considering the Variation of Stream Flow and Water Quality for the Management of Total Maximum Daily Loads (하천 유량.수질변화 특성을 고려한 수질오염총량관리 기준유량 조건에 관한 연구)

  • Park, Jun Dae;Oh, Seung Young;Choi, Yun Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.3
    • /
    • pp.426-435
    • /
    • 2012
  • The variation of stream flow is the one of the most important factors which influence on that of water quality in the unit watershed. The target water quality goal is established and permissible load is allotted in the base of the standard flow condition along with its water quality for the management of Total Maximum Daily Loads (TMDLs). A standard flow selected could cause problems in the load allotment if it was not properly arranged. This study reviewed the acquisition of water quality data, the self-variation and the retainability in water quality on the specific flow conditions. This study also proposed the median and the adjusted average flow condition out of general flow conditions as alternative standard flow conditions. It is considered that the alternatives can make the water quality data easily acquired and the water quality representativeness more enhanced on the standard flow conditions.

Direction Information Concerned Algorithm for Removing Gaussian Noise in Images

  • Gao, Yinyu;Kim, Nam-Ho
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.6
    • /
    • pp.758-762
    • /
    • 2011
  • In this paper an efficient algorithm is proposed to remove additive white Gaussian noise(AWGN) with edge preservation. A function is used to separate the filtering mask to two sets according to the direction information. Then, we calculate the mean and standard deviation of the pixels in each set. In order to preserve the details, we also compare standard deviations between the two sets to find out smaller one. Corrupted pixel is replaced by the mean of the filtering window's median value and the smaller set's mean value that the rate of change is faster than the other one. Experiment results show that the proposed algorithm outperforms with significant improvement in image quality than the conventional algorithms. The proposed method removes the Gaussian noise very effectively.

Power Load Density Analysis considering Structure and Characteristics of Subway Stations (지하철 역사의 구조 및 특성을 고려한 동력부하밀도 분석)

  • Jung, Hyun-Ki;Cha, Kwang-Seok
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.912-920
    • /
    • 2006
  • The purpose of this study is to present the design standard for load density in subway station. From the data of electric equipment capacity and electric power consumption for 43 subway stations, current levels of the load density and excess capacity factor were surveyed and analyzed, In addition mean value, standard deviation, maximum value, median value and correlation coefficient were evaluated through excel program. Also it was carried out the regression analysis. The estimation method of load density and design criterion were studied. As a result, load density in this thesis have been proposed : 51.3 $[VA/m^2]$ on the general power load can be a standard value for subway station.

  • PDF

Effect of Heavy Metals on Embryonic Development in the Mussel, Mytilus galloprovincialis

  • Sung, Chan-Gyoung;Kim, Gi-Beum;Lee, Chang-Hoon
    • The Korean Journal of Malacology
    • /
    • v.22 no.2
    • /
    • pp.167-173
    • /
    • 2006
  • The embryos of marine bivalves have been commonly used in bioassays for quality assessments of marine environments. Although several standard protocols for the developmental bioassay of bivalves have been proposed, only a few trials for application of these protocols in environmental assessments or for the development of a new protocol with Korean species have been conducted. As such, there is a strong need to establish standard bioassay protocols with bivalves commonly found in Korean waters. To determine the sensitivity of Mytilus galloprovincialis to establish a standard bioassay, their fertilized eggs were exposed to six metals (Ag, Cd, Cr, Cu, Ni, and Zn). The order of biological impact was Ag > Cu > Ni > Zn > Cr > Cd and their lowest observed effective concentration were 5, 16.4, 25.4, 142, 187 and 1,500${\mu}g/l$, respectively. The proportion of normal larvae appeared to decrease linearly with the logarithm of each toxicant concentration within the tested range. The average values of median effective concentrations $(EC_{50})$ from the triplicate experiments for Ag, Cd, Cr, Cu, Ni, and Zn were 6.8, 1,797, 786, 16.6, 68.1, and 139.2${\mu}g/l$, respectively. There was a more than 100-fold difference in $EC_{50}$ values of Cu and Cd. The value of $EC_{50}$ or median lethal concentration of Cu was within the range observed for other bivalve developmental bioassays. The overall sensitivity of M. galloprovincialis in the present developmental bioassay was also similar to that of other marine organisms commonly used in aquatic bioassays (e.g. sea urchins, oysters). Hence, the bioassay using the embryo of M. galloprovincialis is considered to be a useful tool to monitor and evaluate the quality of marine aquatic environments.

  • PDF

Survival Outcomes after Whole Brain Radiation Therapy and/or Stereotactic Radiosurgery for Cancer Patients with Metastatic Brain Tumors in Korea: A Systematic Review

  • Hyun, Min Kyung;Hwang, Jin Seub;Kim, Jin Hee;Choi, Ji Eun;Jung, Sung Young;Bae, Jong-Myon
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.12
    • /
    • pp.7401-7407
    • /
    • 2013
  • Aim: To compare survival outcomes after whole brain radiation therapy (WBRT), stereotactic radiosurgery (SRS), and WBRT plus SRS combination therapy in Korea, by performing a quantitative systematic review. Materials and Methods: We searched 10 electronic databases for reports on Korean patients treated with WBRT or SRS for brain metastases published prior to July 2010. Independent reviewers screened all articles and extracted the data. When a Kaplan-Meier survival curve was available, median survival time and standard errors were calculated. Summary estimates for the outcomes in each study were calculated using the inverse variance random-effects method. Results: Among a total of 2,761 studies, 20 studies with Korean patients (n=1,053) were identified. A combination of 12 studies (n=566) with WBRT outcomes showed a median survival time of 6.0 months (95%CI: 5.9-6.2), an overall survival rate of 5.6% (95%CI: 1-24), and a 6-month survival rate of 46.5% (95%CI: 37.2-56.1). For nine studies (n=412) on SRS, the median survival was 7.9 months (95%CI: 5.1-10.8), and the 6-month survival rate was 63.1% (95%CI: 49.8-74.8). In six studies (n=75) using WBRT plus SRS, the median survival was 10.7 months (95%CI: 4.7-16.6), and the overall and 6-month survival rates were 16.8% (95%CI: 6.2-38.2) and 85.7% (95%CI: 28.3-96.9), respectively. Conclusions: WBRT plus SRS showed better 1-year survival outcome than of WBRT alone for Korean patients with metastatic brain tumors. However, the results of this analysis have to be interpreted cautiously, because the risk factors of patients were not adjusted in the included studies.